978 resultados para Expanded flap
Resumo:
INTRODUCTION: Tissue expanders have been of great value in plastic surgery. Tissue expansion was developed for a specific indication; however, within a very short time, the concept of tissue expansion found wide applicability. From 1990 to 1999, 315 expanders in 164 patients were utilized. A retrospective analysis of complications and prognostic factors for complications were done. METHODS: The indications for tissue expansion were burns (50%), trauma (32%), and sequelae of previous surgery (8.8%). The expanders were inserted most frequently in the scalp, trunk and neck. RESULTS: There were 22.2% of complications and the most common were expander exposure (50%), infection (24%) and bad function of the expander (12.8%). The present study revealed an increased rate of minor complications in the group of 0 to 10 years of age and an increased rate of major complications for face and neck expansions compared to trunk expansion. There were no increased complication rates for the other age and anatomic site groups, previous expansion, concomitant expansion and type of expander used. CONCLUSIONS: The outcomes from tissue expansion procedures done in our hospital are similar to those reported in the literature. Tissue expansion is a good and safe technique.
Resumo:
Objectives/Hypothesis: Blood supply to the Hadad-Bassagasteguy pedicled nasoseptal flap may be interrupted by surgery of the pterygopalatine fossa, posterior septectomy, or large sphenoidotomies. This would preclude its use for reconstruction of skull base defects after expanded endonasal approaches (EEA). We present a novel method to ascertain the patency of the nasoseptal artery after prior surgery, and consequently the availability of the nasoseptal flap, using acoustic Doppler sonography. Study Design: Retrospective clinical review. Methods: Four patients who underwent EEAs were evaluated intraoperatively with acoustic Doppler sonography. The mucosa that covers the inferior aspect of the rostrum of the sphenoid sinus was scanned with the tip of the probe. Reflection of sound waves representing intravascular blood flow was assessed. Results: In three patients, the artery was identified in at least one side. One remaining patient showed no acoustic signal suggesting loss of the nasoseptal artery bilaterally, therefore necessitating the use of a fat graft for the reconstruction. Conclusions: Acoustic Doppler sonography seems to be a feasible and effective way to ascertain the availability of the nasoseptal artery. It is a relatively inexpensive and simple technique that can be performed by any endoscopic surgeon.
Resumo:
Objective: The purpose of this study was to evaluate the effect of 830-nm laser in blocking the action of nicotine on the viability of skin flap. Background data: The authors have analyzed the deleterious effect of cigarette smoke or nicotine on the skin flap alone with evidence of increased skin necrosis in the flap. Materials and methods: Twenty-four Wistar-albino rats were divided into three groups of eight animals each: Group 1 (control), subjected to a surgical technique to obtain a flap for cranial base, laser irradiation simulation, and a subcutaneous injection of saline; Group 2, similar to Group 1, with subcutaneous injection of nicotine (2mg/kg/day) for a period of 1 week before and 1 week after surgery; and Group 3, similar to Group 2, with skin flaps subjected to a lambda 830-nm laser irradiation. The laser parameters used were: power 30 mW, beam area 0.07cm(2), irradiance 429 mW/cm(2), irradiation time 84 sec, total energy 2.52J, and energy density 36J/cm(2). The laser was used immediately after surgery and for 4 consecutive days, in one point at 2.5 cm of the flap cranial base. The areas of necrosis were examined by two macroscopic analyses: paper template and Mini-Mop (R). The pervious blood vessels were also counted. Results: The results were statistically analyzed by ANOVA and post-test contrast orthogonal method (multiple comparisons), showing that the laser decreased the area of necrosis in flaps subjected to nicotine, and consequently, increased the number of blood vessels (p < 0.05). Conclusions: The laser proved to be an effective way to decrease the area of necrosis in rats subjected to nicotine, making them similar to the control group.
Resumo:
Objective: The aim of this study was to assess the effects of 830 and 670 nm laser on malondialdehyde (MDA) concentration in random skin-flap survival. Background Data: Low-level laser therapy (LLLT) has been reported to be successful in stimulating the formation of new blood vessels and activating superoxide-dismutase delivery, thus helping the inhibition of free-radical action and consequently reducing necrosis. Materials and Methods: Thirty Wistar rats were used and divided into three groups, with 10 rats in each one. A random skin flap was raised on the dorsum of each animal. Group 1 was the control group; group 2 received 830 nm laser radiation; and group 3 was submitted to 670 nm laser radiation. The animals underwent laser therapy with 36 J/cm(2) energy density immediately after surgery and on the 4 days subsequent to surgery. The application site of the laser radiation was 1 point, 2.5 cm from the flap's cranial base. The percentage of the skin-flap necrosis area was calculated 7 days postoperative using the paper-template method, and a skin sample was collected immediately after as a way of determining the MDA concentration. Results: Statistically significant differences were found between the necrosis percentages, with higher values seen in group 1 compared with groups 2 and 3. Groups 2 and 3 did not present statistically significant differences (p > 0.05). Group 3 had a lower concentration of MDA values compared to the control group (p < 0.05). Conclusion: LLLT was effective in increasing the random skin-flap viability in rats, and the 670 nm laser was efficient in reducing the MDA concentration.
Resumo:
The S phase, known as expanded austenite, is formed on the surfaces of austenitic stainless steels that are nitrided under low temperature plasma. A similar phase was observed for nitrided ferritic stainless steels and was designed as expanded ferrite or ferritic S phase. The authors treated samples of austenitic AISI 304L and AISI 316L and ferritic AISI 409 stainless steels by plasma nitriding at different temperatures and then studied the structural, morphological, chemical and corrosion characteristics of the modified layers by X-ray diffraction, scanning electron microscopy/energy dispersive spectroscopy and electrochemical tests. For both austenitic AISI 304L and AISI 316L stainless steels, the results showed that a hard S phase layer was formed on the surfaces, promoting an anodic polarisation curve displacement to higher current density values that depend on the plasma nitriding temperature. A layer having a high amount of nitrogen was formed on the ferritic AISI 409 stainless steel. X-ray diffraction measurements indicated high strain states for the modified layers formed on the three stainless steels, being more pronounced for the ferritic S phase.
Resumo:
This study evaluated hydrogen production in an anaerobic fluidized bed reactor (AFBR) fed with glucose-based synthetic wastewater. Particles of expanded clay (2.8-3.35 mm) were used as a support material for biomass immobilization. The reactor was operated with hydraulic retention times (HRT) ranging from 8 to 1 h. The hydrogen yield production increased from 1.41 to 2.49 mol H(2) Mol(-1) glucose as HRT decreased from 8 to 2 h. However, when HRT was 1 h, there was a slight decrease to 2.41 mol H(2) Mol(-1) glucose. The biogas produced was composed of H(2) and CO(2), and the H(2) content increased from 8% to 35% as HRT decreased. The major soluble metabolites during H(2) fermentation were acetic acid (HAc) and butyric acid (HBu), accounting for 36.1-53.3% and 37.7-44.9% of total soluble metabolites, respectively. Overall, the results demonstrate the potential of using expanded clay as support material for hydrogen production in AFBRs. (c) 2008 International Association for Hydrogen Energy. Published by Elsevier Ltd. All rights reserved.
Resumo:
The initiation of graft vs. host disease (GVHD) after stem cell transplantation is dependent on direct antigen presentation by host antigen presenting cells (APC) while the effect of indirect antigen presentation by donor APC is unknown. We have studied the role of indirect antigen presentation in allogenic responses by adding populations of cytokine-expanded donor APC to haematopoietic grafts that would otherwise induce lethal GVHD. Progenipoietin-1 (a synthetic G-CSF/Flt-3 L molecule) and G-CSF expanded myeloid DC, plasmacytoid DC and a novel granulocyte-monocyte precursor population (GM) that differentiate into class IIpos, CD80/CD86pos, CD40neg APC during GVHD. Whereas addition of plasmacytoid and myeloid donor DC augmented GVHD, GM cells induced transplant tolerance via MHC class II restricted generation of IL-10-secreting regulatory T cells. Thus a population of cytokine expanded granulocyte-monocyte precursors function as regulatory antigen presenting cells, suggesting that G-CSF derivatives may have application in disorders characterised by a loss of self-tolerance.
Resumo:
Background: Surgical resection in locally advanced breast cancer produces large defects that may not be suitable for primary closure. Immediate reconstruction is controversial and presents a complicated scenario for breast surgeons and plastic surgeons. Methods: In this study, a different design was planned for the latissimus dorsi musculocutaneous flap with primary closure in V-Y for the correction of major lesions in the anterior chest wall. Twenty-five patients underwent immediate locally advanced breast cancer reconstruction with a V-Y latissimus dorsi musculocutaneous flap. This flap was raised from adjacent tissue located on the lateral and posterior thoracic region and presented a triangular shape whose base was the lateral aspect of the mastectomy wound. The technique was indicated in patients with large thoracic wounds. Results: Mean follow-up time was 16 months. Closure was obtained in the donor and recipient sites without the use of skin grafts or other more major procedures. Complications occurred in nine patients (36 percent), including dorsal wound dehiscence in five patients and seroma in three. All cases except one were treated by a conservative approach with a good result. No total flap loss was reported. All patients achieved a satisfactory thoracic reconstruction and adequate wound care. Conclusions: The V-Y latissimus dorsi musculocutaneous flap is a reliable technique for immediate locally advanced breast cancer reconstruction. The technique is advantageous because the V-Y design allows primary closure of the chest wound and donor defect. Success depends on patient selection, coordinated planning with the breast cancer surgeon, and careful intraoperative management. (Plast. Reconstr. Surg. 127: 2186, 2011.)
Resumo:
After massive weight loss, one of the stigmas that afflict women is the remaining deformity of the breasts which become flaccid and ptotic, with an absent or flat upper pole. The authors propose the use of a well-established mammaplasty technique to fill the upper pole, reshape the breast cone, and correct ptosis with nipple-areola complex (NAC) repositioning. A total of 16 patients were analyzed; all underwent gastroplasty between 18 and 24 months prior to mammaplasty. The mean age was 41.6 years (range = 26-62) and the mean BMI previous to the mammaplasty was 29.2 kg/m(2) (range = 24.9-38.9). The technique included a dermo-lipo glandular flap pedicled on the inframammary fold (IMF) together with a superior flap containing the NAC. All patients who underwent surgery were satisfied with the outcomes since a more aesthetic breast shape was achieved, with projection of the upper pole and correction of ptosis. Adverse events included dehiscence at the junction point of the flaps in the inframammary fold, which resolved with secondary-intention wound healing in three patients; partial necrosis of the areola in one patient; epidermolysis in one of the NACs in one patient; and infection in one of the breasts in one patient, which resolved with proper antibiotic therapy. When compared to the current mammaplasty techniques performed in formerly obese patients, this is a good surgical option because it uses tissues adjacent to the breast itself and does not require silicone prosthesis for breast augmentation. The patients reported increased self-esteem and improvement in their quality of life.
Resumo:
BACKGROUND & AIMS: There is controversy over whether coagulation status predicts bleeding caused by ulceration after esophageal varices band ligation (EVL). METHODS: EVL was performed for primary (n = 45) or secondary (n = 105) prophylaxis in 150 patients with cirrhosis (Child A, n = 74, 49%; Child B, n = 42, 28%; Child C, n = 34, 23%). International normalized ratio (INR) and platelet counts were assessed in all. In 92 patients, levels of factor V, fibrinogen, D-dimer, protein C and protein S, von Willebrand factor, and thromboelastography (TEG) were assessed. Platelet count < 50 x 10(3)/mm(3) and INR > 1.5 were considered high-risk cutoff for bleeding. Conversely, platelet count >= 50 x 10(3)/mm(3) with INR <= 1.5 were safe cutoffs. RESULTS: Overall, 11 patients (7.3%) had post-EVL ulcer bleeding. Bleeding occurred in S patients with Child A/B (4.3%) and 6 patients with Child C (17%) (P = .0174 for Child A/B versus Child C). Eight patients with bleeding were among the 110 below the cutoff for INR and platelet count, whereas only 3 of the patients with bleeding were among the 40 patients with purported high-risk values (P = 1.0). Among the 92 patients with expanded coagulation tests, bleeding occurred in S. There was no difference in any of the coagulation parameters, including overall TEG patterns, between patients who did and did nor bleed. CONCLUSIONS: Post-EVL ulcer bleeding was associated with Child C status but not with conventional or expanded coagulation indices in cirrhotic patients without renal failure or infection undergoing elective EVL. These results call into question the common use of prophylactic procoagulants in the elective setting.
Resumo:
Background: Several studies have already reported the utilization of fibrin glue in microvascular anastomoses to minimize the number of sutures and to decrease the operative time. Despite the good results obtained in most of these experiments, its clinical application has not launched. The aim of this study was to clarify the controversies around the safeness of fibrin glue application in microvascular anastomoses, and also to demonstrate the potential benefits of fibrin glue application in a realistic free flap model. Methods: Twenty-seven rabbits were used in this study The experimental model consisted of a free groin flap transfer to the anterior cervical region. The flap`s circulation was restored by means of an end-to-side anastomosis between the femoral and carotid arteries, and an end-to-end anastomosis between the femoral and external jugular veins. The animals were divided into two groups (n = 10) according to the anastomosis technique: Group I (conventional suture) and group 11 (fibrin glue). Results: The number of sutures required to complete the arterial and venous anastomoses was reduced in 39 and 37% in group 11, respectively. Despite this reduction, the anastomoses maintained adequate patency rates and mechanical strength. Both arterial and venous anastomoses benefited from fibrin glue application, which made them easier and faster to perform. The flaps` ischemic time and the total operative time were also significantly shortened. Conclusions: In this study, the application of fibrin glue in microvascular anastomoses was safe and reliable. The risk-benefit ratio of fibrin glue application in microvascular anastomoses is favorable for its use. (c) 2008 Wiley-Liss, Inc.
Resumo:
Objective: This is a clinical study of our experience using pedicle perforator flaps to cover skin defects in the middle and distal segment of the leg. Design: Prospective study. Setting: University hospital. Patients/Intervention: Twenty-four patients underwent treatment of a skin defect in the middle or distal segment of the leg by means of pedicled flaps based on perforating arteries. The perforating arteries were located before the operation by means of echo-Doppler examination. The flaps were planned in propeller fashion (21 cases) and as advancement (three cases). Main Outcome Measurements: The results were evaluated according the origin of perforator flap, size of the flap, and donor area and viability of the flap. The success rate of the echo-Doppler to identify the location of perforator vessel was also evaluated. Results: In nine cases, the perforating vessels originated from the fibular artery, in 10 the posterior tibial artery, and in five the anterior tibial artery. The mean size of the flaps was 5 cm in width by 12 cm in length. The success rate using an echo-Doppler was 87%. The flaps were fully viable in 20 cases and partially viable in four cases. Conclusion: On the basis of these results, it is concluded that perforating flaps are a good choice of treatment for skin losses, especially in the distal segment of the leg, and could be an alternative option for the use of free microsurgical flaps.
Resumo:
Heterodigital pedicle flaps have 2 possible patters of vascularization: anterograde flow (Littler) or reverse flow (Adani). The Adani`s flap uses the Y-V pedicle lengthening principle. The flap is raised from the adjacent uninjured finger based on the digital artery. The common digital artery is ligated and a long pedicle is formed from the 2 converging digital arteries to supply a reverse flow flap. Four patients with severe fingertips injuries were submitted to surgical treatment with the Adani`s flap. All flaps integrated and provided skin coverage. The Adani`s flap has a long vascular pedicle that allows a wide arch of transposition. An easier vascular dissection in a site distant from the trauma which evolves a higher diameter digital artery and proximal interphalangeal arterial system promotes a high survival rate and good functional results. Adani`s flap is a reliable technique for severe fingertip injuries.
Resumo:
Objective: Clinical evaluation of the stomatognathic system is indispensable for the diagnosis of orofacial myofunctional disorders. In order to obtain a more precise diagnosis, the protocol of orofacial myofunctional evaluation with scores (OMES protocol) (Int. J. Pediatr. Otorhinolaryngol. 72 (2008) 367-375) was expanded in terms of number of items and scale amplitude. The proposal of this study is to describe the expanded OMES protocol (OMES-E) for the evaluation of children. Validity of the protocol, reliability of the examiners and agreement between them were analyzed, as also were the sensitivity, specificity and predictive values of the instrument. Methods: The sample consisted of videorecorded images of 50 children, 25 boys (mean age = 8.4 years, SD = 1.8) and 25 girls (mean age = 8.2 years, SD = 1.7) selected at random from 200 samples. Three speech therapists prepared for orofacial myofunctional evaluation participated as examiners (E). The OMES and OMES-E protocols were used for evaluation on different days. E1 evaluated all images, E2 analyzed children with recordings from 1 to 25 and E3 analyzed children with recordings from 26 to 50. The validity of OMES-E was analyzed by comparing the instrument to the OMES protocol using the Pearson correlation test complemented with the split-half reliability test (p < 0.05). The linear weighted Kappa coefficient of agreement (Kw`), the sensitivity, specificity and predictive values and the prevalence of OMD were calculated. Results: There was a statistically significant correlation between the OMES and OMES-E protocols (0.79 > r < 0.94, p < 0.01) and a significant test-retest correlation with the OMES-E (0.75 > r < 0.86, p < 0.01), with a reliability range of 0.86-0.93. The correlation and reliability coefficients between examiners were: E1 x E2 (r = 0.74, 0.84), E1 x E3 (r = 0.70, 0.83) (p < 0.01). Kw` coefficients with moderate and good strength predominated. The OMES-E protocol presented mean sensitivity = 0.91, specificity = 0.77, positive predictive value = 0.87 and negative predictive value = 0.85. The mean prevalence of OMD was 0.58. Conclusion: The OMES-E protocol is valid and reliable for orofacial myofunctional evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objective: To test the viability of a tracheal autotransplant, with an original technique using a prefabricated flap from a complete tracheal neovascularized segment (CTNVS) of the sternohyoid muscle anastomosed by a microsurgical technique. Study Design: An experimental study using dogs as an animal model. Methods: Ten mongrel dogs weighing 23 to 40 kg were divided into two groups: group I (control), five animals submitted to autotransplant of the CTNVS without a microsurgical vascular anastomosis; and group II, five dogs submitted to autotransplant of the CTNVS with a microsurgical vascular anastomosis. Results: All group I dogs developed respiratory insufficiency and died because of necrosis and stenosis of the autotransplanted CTNVS, whereas all group II dogs completed a minimum period of 90 days of observation without any clinical changes. Macro- and microscopic analysis revealed intact tracheal structures. Conclusions: The present clinical and morphological findings demonstrate that the CTNVS autotransplant is viable, when a microsurgical vascular anastomosis is used.