1000 resultados para Estabilidade de suspensões
Resumo:
In this work, aqueous suspensions of aluminas with different particle sizes were evaluated. The effect of pH on the electrosteric stabilization using PMAA-NH4 (ammonium polymethacrylate) as deflocculant was studied. The amount of deflocculant was optimized and rheologic properties were determined at four different pH values. Sedimentation was also evaluated. For suspensions with pH 4, an electrostatic mechanism of stabilization was observed, probably due to a flat adsorption of PMMA- on the alumina surface, leading to a small efficiency in relation to steric stabilization. For a suspension with pH 12, the steric mechanism of stabilization prevails. Suspensions with pH 7 and 9 present a higher flocculation degree. In relation to particle size, A-1000 samples present a smaller particle size, leading to a smaller interparticle distance (IPS), making stabilization more difficult.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Revestimentos compósitos com incorporação de SiC (com tamanho médio 600nm e 30nm) à matriz metálica de Ni-P foram elaborados por eletrodeposição a partir de uma solução de sais de níquel, contendo um precursor fosforoso H3PO3, na qual as partículas foram colocadas em suspensão. A partir de medidas de viscosidade e velocidade de sedimentação foi evidenciado que o tamanho das partículas de SiC é uma característica importante que influencia na estabilidade das suspensões. Além disso, a presença de aditivos orgânicos, como SDS ou CTAHS, modifica as características das suspensões podendo ter, de acordo com o tamanho das partículas, um efeito sobre a taxa de incorporação da mesma no depósito durante o crescimento da matriz. Observou-se que acima de uma certa concentração de partículas em suspensão, a taxa de incorporação avaliada em função da fração em volume atinge um patamar, quando, no entanto, a mesma continua a aumentar se avaliada pelo número de partículas incorporadas. Para as suspensões com elevada concentração de partículas, o processo de incorporação torna-se seletivo, e as partículas de menor tamanho são preferencialmente incorporadas. Medidas de microdureza, análise térmica e ensaios eletroquímicos (voltametria cíclica e impedância eletroquímica) foram realizados com o objetivo de investigar o efeito da quantidade e do tamanho das partículas de SiC incorporadas, sobre o comportamento térmico, a microdureza, e a resistência à corrosão dos revestimentos compósitos Ni-P-SiC com teor em fósforo igual a 17 %at.
Resumo:
Compounded medicines have been reported by the ANVISA due to decreased of the therapeutic response or toxicity of these formulations. The aim of this work was to investigate the physicochemical quality control among naproxen sodium oral suspensions 25 mg/mL obtained from six compounding pharmacies (A, B, C, D, E and F) and the manufactured suspension (R). In the quality control test, the tests of pH, content, homogeneity, volume and physical and organoleptic characteristics were performed according to the Brazilian Pharmacopoeia. The analytical method for determination of naproxen in suspensions was validate. This method showed excellent precision, accuracy, linearity and specificity. In the content test the suspensions B, C and E showed lower value and the F suspension showed a high value of the content. The products C and E were disapproved in the description of the physical and organoleptic characteristics test. In the pH test, three suspensions were outside specifications (C, E and F). Only the products R, A and D showed satisfactory results in these tests and therefore they were approved for relative bioavailability test. The R, A and D suspensions were orally administered to Wistar rats and the blood samples were taken at time intervals of 10, 20, 40, 60 min, 3, 4, 6, 24 and 48 h. The plasma samples were immediately stored at 80 ºC until analysis of HPLC. The bioanalytical method validation showed specificity, linearity (R2 0.9987), precision, accuracy, good recovery and stability. The chromatographic conditions were: flow rate of 1.2 mL.min-1 with a mobile phase of acetonitrile : sodium phosphate buffer pH 4.0 (50:50, v/v) at 280 nm, using a C18 column. The confidence interval of 90% for the Cmax and AUCt ratio was within the range of 80 - 125% proposed by the FDA. Only one suspension, obtained from the compounding pharmacy D, was considered bioequivalent to the rate of absorption under the conditions proposed by this study. Thus, the results indicate the need for strict supervision from the relevant authorities to ensure the patient safety and the quality of compounded drugs by pharmacies
Resumo:
The present study describes the stability and rheological behavior of suspensions of poly (N-isopropylacrylamide) (PNIPAM), poly (N-isopropylacrylamide)-chitosan (PNIPAMCS), and poly (N-isopropylacrylamide)-chitosan-poly (acrylic acid) (PNIPAM-CS-PAA) crosslinked particles sensitive to pH and temperature. These dual-sensitive materials were simply obtained by one-pot method, via free-radical precipitation copolymerization with potassium persulfate, using N,N -methylenebisacrylamide (MBA) as a crosslinking agent. Incorporation of the precursor materials into the chemical networks was confirmed by elementary analysis and infrared spectroscopy. The influence of external stimuli such as pH and temperature, or both, on particle behavior was investigated through rheological measurements, visual stability tests and analytical centrifugation. The PNIPAM-CS particles showed higher stability in acid and neutral media, whereas PNIPAM-CS-PAA particles were more stable in neutral and alkaline media, both below and above the LCST of poly (Nisopropylacrylamide) (stability data). This is due to different interparticle interactions, as well as those between the particles and the medium (also evidenced by rheological data), which were also influenced by the pH and temperature of the medium. Based on the results obtained, we found that the introduction of pH-sensitive polymers to crosslinked poly (Nisopropylacrylamide) particles not only produced dual-sensitive materials, but allowed particle stability to be adjusted, making phase separation faster or slower, depending on the desired application. Thus, it is possible to adapt the material to different media
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Vitamin C stability and concentration was evaluated in isotonic beverages and B group vitamins (B1, B2, B3, B5 and B6) in power beverages. The amount of vitamins was found to be above of that declared on the labels, even after the shelf life had been exceeded. A small decrease in the amount of B group vitamins was observed during the shelf life of the products. In the case of vitamin C this decrease was slightly higher. The present research shows the need of increased quality control and inspection.
Resumo:
The chemical industries worldwide are passing through a very particular moment of re-adaptation due to the implementation of an European regulation called, Registration, Evaluation, Authorization and Restriction of Chemicals (REACH). In Brazil, the Brazilian Chemical Industry needs urgently a specific guide of chemical products stability. The main purpose of this work is to present a proposal of a guide of stability for chemical products based on the reference guides of the International Conference on Harmonization (ICH). Thus, this work proposes an innovation in terms of methodology which will be useful for shelf life definition purpose for chemical industry products.
Resumo:
Companies worldwide are reviewing their working process to avoid waste, become aligned with environmental management standards and to fulfill specifications defined for national and international regulations. In this context, it is important that Brazilian Chemical companies have a specific stability guide for their products. The main purpose of this work is to present a stability guide for chemical products based on the existing guides of the Pharmaceutical and Cosmetics segments. Furthermore, this work proposes to offer an additional period of shelf life for chemical products, provided they meet certain prerequisites.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
OBJETIVO: este estudo teve como objetivo avaliar a influência da largura do septo inter-radicular no local de inserção de mini-implantes autoperfurantes sobre o grau de estabilidade desses dispositivos de ancoragem. MÉTODOS: a amostra consistiu de 40 mini-implantes inseridos entre as raízes do primeiro molar e segundo pré-molar superiores de 21 pacientes, com o intuito de fornecer ancoragem para retração anterior. A largura do septo no local de inserção (LSI) foi mensurada nas radiografias pós-cirúrgicas e, sob esse aspecto, os mini-implantes foram divididos em dois grupos: grupo 1 (áreas críticas, LSI<3mm) e grupo 2 (áreas não críticas, LSI>3mm). A estabilidade dos mini-implantes foi avaliada mensalmente pela quantificação do grau de mobilidade e a partir dessa variável foi calculada a proporção de sucesso. Avaliou-se também: a quantidade de placa, altura de inserção, grau de sensibilidade e período de observação. RESULTADOS: os resultados obtidos demonstraram que não houve diferença estatisticamente significativa para o grau de mobilidade e proporção de sucesso entre os mini-implantes inseridos em septos de largura mesiodistal crítica e não crítica. A proporção de sucesso total encontrada foi de 90% e nenhuma variável demonstrou estar relacionada ao insucesso dos mini-implantes. No entanto, observou-se maior sensibilidade nos pacientes cujos mini-implantes apresentavam mobilidade, e que a falha desses dispositivos de ancoragem ocorria logo após sua inserção. CONCLUSÃO: a largura do septo inter-radicular no local de inserção não interferiu na estabilidade dos mini-implantes autoperfurantes avaliados neste estudo.
Resumo:
OBJETIVO: com o propósito de avaliar a influência da extração de dois pré-molares superiores na estabilidade oclusal do tratamento da má oclusão de Classe II completa, foi realizada uma comparação com o protocolo de tratamento sem extrações. MÉTODOS: selecionou-se, a partir das documentações do arquivo da Disciplina de Ortodontia da Faculdade de Odontologia de Bauru, uma amostra composta pelas documentações de 59 pacientes com má oclusão de Classe II completa. Em seguida, dividiu-se essa amostra em dois grupos, apresentando as seguintes características: Grupo 1, constituído por 29 pacientes, tratados sem extrações; e Grupo 2, composto por 30 pacientes, tratados com extrações de dois pré-molares superiores. Os modelos ao início do tratamento, ao final do tratamento e em um período mínimo de 2,4 anos após o tratamento foram medidos e avaliados por meio dos índices oclusais IPT e PAR. As condições oclusais ao final do tratamento e no estágio pós-tratamento, o percentual de recidiva e as alterações oclusais pós-tratamento foram comparados por meio do teste t. RESULTADOS: os resultados demonstraram que os protocolos de tratamento sem extração e com extrações de dois pré-molares superiores não apresentaram, em nenhuma das variáveis avaliadas, diferenças estatisticamente significativas em relação à estabilidade oclusal do tratamento da má oclusão de Classe II completa. CONCLUSÃO: a extração de dois pré-molares superiores no tratamento da má oclusão de Classe II completa não influenciou a estabilidade dos resultados oclusais alcançados ao final da correção ortodôntica. Portanto, terminar o tratamento com uma relação molar em Classe II ou em Classe I proporciona estabilidade semelhante.
Resumo:
OBJETIVO: avaliar as possíveis alterações e a estabilidade dentária e esquelética no sentido transversal, bem como as possíveis alterações verticais da face (AFAI), produzidas pela Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC). MÉTODOS: a amostra selecionada para este estudo retrospectivo foi composta por 60 telerradiografias em norma frontal, de 15 pacientes, sendo 6 do gênero masculino e 9 do gênero feminino, com média de idades de 23 anos e 3 meses. O disjuntor Hyrax foi instalado e o procedimento cirúrgico adotado envolveu a separação da sutura palatina mediana e não-abordagem da sutura pterigomaxilar. A ativação foi realizada do terceiro dias após a cirurgia até o término da expansão, determinada por critérios clínicos. Todos os pacientes foram radiografados nas fases pré-expansão (T1); pós-expansão imediata (T2); 3 meses pós-expansão, com o próprio disjuntor como contenção (T3); e 6 meses pós-expansão, com a placa removível de acrílico como contenção (T4). Medidas lineares foram obtidas a partir dos traçados cefalométricos gerados por um programa computadorizado (Radiocef Studio 2) e analisadas estatisticamente pelos testes de variância (ANOVA) e Tukey ao nível de 5% de significância. RESULTADOS E CONCLUSÕES: concluiu-se que a ERMAC produziu aumentos estatisticamente significativos da cavidade nasal, da largura maxilar e da distância intermolares superiores, de T1 para T2, os quais se mantiveram em T3 e T4. A largura facial e as distâncias intermolares inferiores não apresentaram alterações após a ERMAC. Avaliando o comportamento vertical da face, notou-se um aumento da AFAI nas fases T1 para T2, que diminuiu após a contenção de 3 meses (T3) e permaneceu estável em T4, embora aumentada se comparada com T1.