23 resultados para Endoprosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study is to evaluate the use of cement spacers impregnated with antibiotics for the treatment of infections in the nonconventional endoprostheses of the knee. Methodology: We have treated seven patients since 2004 (of which six were submitted to surgery in our service and one patient had been submitted to a primary tumor surgery in another removal service) with deep infection in knee tumor prosthesis. All patients were submitted to endoprosthesis removal and reconstructed with antibiotic cement spacer All patients were monitored both clinically and by lab tests as for monitoring the evolution, being considered able for reviews after 6 (six) months without infections signs. Results: We have noted a small predominance of infectious processes on the prosthesis inserted on proximal tibia as compared with distal femur (57.1% x 42.9%). The mean follow-up time of patients was 68.2 months. During the follow up, one patient died as a result of the root disease. Six patients out of seven were regarded as cured and one persisted with infection signs and symptoms. Conclusion: The results obtained up to date have motivated us to continue using this method of treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed 37 patients who underwent segmental wide resection of bone tumors and reconstruction with a modular titanium endoprosthesis at the Orthopaedic Oncology Group, between 1992 and 1998. Twelve patients were male and 25 were female, with a mean age of 30 years (9 - 81). The mean follow-up was 14 months (2 - 48). The diagnoses were: osteosarcoma (14 cases), metastatic carcinoma (10), Ewing's sarcoma (4), giant cell tumor (4), malignant fibrous histiocytoma (3), chondrosarcoma (1), and aneurysmal bone cyst (1). Eleven articulated total knee, 8 partial proximal femur with bipolar acetabulum, 8 partial proximal humerus, 3 total femur, 2 partial proximal tibia, 2 diaphyseal femur, 2 diaphyseal humerus, and 1 total proximal femur with cementless acetabulum endoprosthesis implant procedures were done. The complications related to the procedure included: infection (5 cases), dislocation (3), module loosening (1), and ulnar nerve paresthesia (1). We used the following criteria for the clinical evaluation: presence of pain, range of motion, reconstruction stability, surgical and oncologic complications, and patient acceptance. The results were good in 56.8% of the cases, regular in 32.4% and poor in 10.8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new digital computer mock circulatory system has been developed in order to replicate the physiologic and pathophysiologic characteristics of the human cardiovascular system. The computer performs the acquisition of pressure, flow, and temperature in an open loop system. A computer program has been developed in Labview programing environment to evaluate all these physical parameters. The acquisition system was composed of pressure, flow, and temperature sensors and also signal conditioning modules. In this study, some results of flow, cardiac frequencies, pressures, and temperature were evaluated according to physiologic ventricular states. The results were compared with literature data. In further works, performance investigations will be conducted on a ventricular assist device and endoprosthesis. Also, this device should allow for evaluation of several kinds of vascular diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyze in an experimental animal model the effect of 4 different levels of stents-graft oversizing on non-atherosclerotic aortas such as those found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N, and D: 46 N). However, 2 aortas ruptured during the tests (groups C and D). The second test was performed in 3 aortic segments. Maximum shear strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. Strain, which reflects the elastic properties of the aortic wall, was very similar in all 4 groups, but a great difference was found when compared with the control group (p<0.0001). Conclusion: The study showed an important subacute change in the biomechanical properties of the aortic wall after implantation of an oversized endoprosthesis. This weakness of the aortic wall was confirmed by 2 ruptures during the detachment test. These results partially explain the interaction of stent-grafts with non-atherosclerotic thoracic aortas and may serve as a basis for further studies and the development of specific material to be used in vascular trauma and young patients. J Endovasc Ther. 2011; 18: 576-584

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Curative resection of pancreatic and biliary malignancies is rare. Most tumors are inoperable at presentation, and palliation of jaundice often is the goal. Biliary decompression can be achieved by surgical diversion or endoscopic biliary stents. This study aimed to compare clinical outcomes between surgical bypass and endoscopic uncovered nitinol stents in the palliation of patients with malignant distal common bile duct obstruction. Methods A multicenter, retrospective, cohort study investigated 86 patients with inoperable malignant distal common bile duct strictures at tertiary referral centers in Medellin, Colombia. These patients had undergone surgery (group 1) or placement of an uncovered 30-Fr self-expandable nitinol stent produced locally in Medellin, Colombia (group 2). The main outcome measurements included cumulative biliary patency, hospital stay, and patient survival. Results The study enrolled 86 patients (mean age, 66 years; range, 43-78 years) including 40 patients in group 1 and 46 patients in group 2. Both groups were similar in terms of age, gender, liver metastasis, and diagnosis. Technical success was achieved for 38 patients in group 1 (95%) and 43 patients in group 2 (93%). Functional biliary decompression was obtained in for 35 of the surgical patients (88%) and 42 of the stented patients (91%). Group 2 had lower rates for procedure-related mortality (2 vs. 7.5%; p = 0.01), a lower frequency of early complications (8.7 vs. 45%; p = 0.02), and a shorter hospital stay (median, 6 vs. 12 days; p = 0.01). Recurrent jaundice occurred for three patients in group 1 (7.5%) and eight patients in group 2 (17.3%) (p = 0.198). Late gastric outlet obstruction occurred for 12.5% of the patients in group 1 and 13% of the patients in group 2 (p = 0.73). Despite the early benefits of stenting, no significant difference in the median overall survival between the two groups was found (group 1, 163 days; group 2, 178 days; p = 0.11). The limitations of this study included the small number of patients and the retrospective design. Conclusions Endoscopic stenting and surgery are effective palliation. The former is associated with fewer early complications and the latter with fewer late complications. Patients who do not qualify for curative resection may be better managed by stent placement. Surgery should be reserved for patients more likely to survive longer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An aneurysm is a localized blood-filled dilatation of an artery whose consequences can be deadly. One of its current treatments is endovascular aneurysm repair, a minimally invasive procedure in which an endoprosthesis, called a stent-graft, is placed transluminally to prevent wall rupture. Early stent-grafts were custom designed for the patient through the assembling of off-the-shelf components by the operating surgeon. However, nowadays, stent-grafts have become a commercial product. The existing endoprostheses differ in several aspects, such as shape design and materials, but they have in common a metallic scaffold with a polymeric covering membrane. This article aims to gather relevant information for those who wish to understand the principles of stent-grafts and even to develop new devices. Hence, a stent-graft classification based on different characteristics is presented and the desired features for an ideal device are pointed out. Additionally, the materials currently in use to fabricate this type of endoprosthesis are reviewed and new materials are suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Apresentam-se seis casos de síndrome da veia cava superior causado por neoplasia do pulmão e que foram tratados por endopróteses colocadas por via percutânea. Descreve-se a técnica e avaliam-se os resultados. Num caso ocorreu trombose aguda da endoprótese que foi tratada por uroquinase. Não se registaram outras complicações. Um doente faleceu 1 mês depois por progressão da doença. Os restantes mantinham-se sem queixas de síndrome da veia cava superior durante mais do que 6 meses. Conclui-se que a colocação de endopróteses é uma técnica pouco invasiva, eficaz e com melhoria imediata no síndrome da veia cava superior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors report two cases in which stent grafts were used to treat visceral artery aneurysms. Case number 1 was a 42-year old woman with a history of renal colic who was found to have a right renal artery aneurysm. Two 6-mm x 20-mm Wallgraft endoprosthesis (Boston Scientific, Watertown, Mass) were placed across the aneurysm neck. Case number 2 was a 72 year-old woman with a past medical history significant for hepatic angioma and hypothyroidism. She was found to have a superior mesenteric artery aneurysm that was treated with a 6-mm x 17-mm Jostent stent graft (Jomed, GmbH, Ra). In both cases the aneurysm was completely excluded and distal end-organ flow preserved. Stent graft placement is a safe and effective treatment for visceral artery aneurysms. If this approach proves durable and reproducible, it can become the method of choice for the management of visceral artery aneurysms in selected patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Long-term follow-up after endovascular aneurysm repair (EVAR) is very scarce, and doubt remains regarding the durability of these procedures. We designed a retrospective cohort study to assess long-term clinical outcome and morphologic changes in patients with abdominal aortic aneurysms (AAAs) treated by EVAR using the Excluder endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz). METHODS: From 2000 to 2007, 179 patients underwent EVAR in a tertiary institution. Clinical data were retrieved from a prospective database. All patients treated with the Excluder endoprosthesis were included. Computed tomography angiography (CTA) scans were retrospectively analyzed preoperatively, at 30 days, and at the last follow-up using dedicated tridimensional reconstruction software. For patients with complications, all remaining CTAs were also analyzed. The primary end point was clinical success. Secondary end points were freedom from reintervention, sac growth, types I and III endoleak, migration, conversion to open repair, and AAA-related death or rupture. Neck dilatation, renal function, and overall survival were also analyzed. RESULTS: Included were 144 patients (88.2% men; mean age, 71.6 years). Aneurysms were ruptured in 4.9%. American Society of Anesthesiologists classification was III/IV in 61.8%. No patients were lost during a median follow-up of 5.0 years (interquartile range, 3.1-6.4; maximum, 11.2 years). Two patients died of medical complications ≤ 30 days after EVAR. The estimated primary clinical success rates at 5 and 10 years were 63.5% and 41.1%, and secondary clinical success rates were 78.3% and 58.3%, respectively. Sac growth was observed in 37 of 142 patients (26.1%). Cox regression showed type I endoleak during follow-up (hazard ratio, 3.74; P = .008), original design model (hazard ratio, 3.85; P = .001), and preoperative neck diameter (1.27 per mm increase, P = .006) were determinants of sac growth. Secondary interventions were required in 32 patients (22.5%). The estimated 10-year rate of AAA-related death or rupture was 2.1%. Overall life expectancy after AAA repair was 6.8 years. CONCLUSIONS: EVAR using the Excluder endoprosthesis provides a safe and lasting treatment for AAA, despite the need for maintained surveillance and secondary interventions. At up to 11 years, the risk of AAA-related death or postimplantation rupture is remarkably low. The incidences of postimplantation sac growth and secondary intervention were greatly reduced after the introduction of the low-permeability design in 2004.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Intensive image surveillance after endovascular aneurysm repair is generally recommended due to continued risk of complications. However, patients at lower risk may not benefit from this strategy. We evaluated the predictive value of the first postoperative computed tomography angiography (CTA) characteristics for aneurysm-related adverse events as a means of patient selection for risk-adapted surveillance. METHODS: All patients treated with the Low-Permeability Excluder Endoprosthesis (W. L. Gore & Assoc, Flagstaff, Ariz) at a tertiary institution from 2004 to 2011 were included. First postoperative CTAs were analyzed for the presence of endoleaks, endograft kinking, distance from the lowermost renal artery to the start of the endograft, and for proximal and distal sealing length using center lumen line reconstructions. The primary end point was freedom from aneurysm-related adverse events. Multivariable Cox regression was used to test postoperative CTA characteristics as independent risk factors, which were subsequently used as selection criteria for low-risk and high-risk groups. Estimates for freedom from adverse events were obtained using Kaplan-Meier survival curves. RESULTS: Included were 131 patients. The median follow-up was 4.1 years (interquartile range, 2.1-6.1). During this period, 30 patients (23%) sustained aneurysm-related adverse events. Seal length <10 mm and presence of endoleak were significant risk factors for this end point. Patients were subsequently categorized as low-risk (proximal and distal seal length ≥10 mm and no endoleak, n = 62) or high-risk (seal length <10 mm or presence of endoleak, or both; n = 69). During follow-up, four low-risk patients (3%) and 26 high-risk patients (19%) sustained events (P < .001). Four secondary interventions were required in three low-risk patients, and 31 secondary interventions in 23 high-risk patients. Sac growth was observed in two low-risk patients and in 15 high-risk patients. The 5-year estimates for freedom from aneurysm-related adverse events were 98% for the low-risk group and 52% for the high-risk group. For each diagnosis, 81.7 image examinations were necessary in the low-risk group and 8.2 in the high-risk group. CONCLUSIONS: Our results suggest that the first postoperative CTA provides important information for risk stratification after endovascular aneurysm repair when the Excluder endoprosthesis is used. In patients with adequate seal and no endoleaks, the risk of aneurysm-related adverse events was significantly reduced, resulting in a large number of unnecessary image examinations. Adjusting the imaging protocol beyond 30 days and up to 5 years, based on individual patients' risk, may result in a more efficient and rational postoperative surveillance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The usual treatment of blunt aortic injury (BAI) is prompt surgery. Frequently severe injuries to the brain or lungs exclude further surgical treatment. The purpose of this study is to assess the feasibility of placing endovascular stent-grafts. METHODS: From 1992 through 1999, in our primary and referral trauma center, 26 acute BAI, 21 males and 5 females, mean age 40.2+/-16.3 yrs were diagnosed. The last 4 patients underwent prospectively endovascular repair with Talent endograft. Endoprosthesis parameters were measured on three-dimensional spiral CT reconstruction. While waiting for devices, blood pressure was aggressively lowered and aortic lesions were monitored by transesophageal echography. RESULTS: Stent-graft deployment was successful in all 4 patients. There were no complications of endoleak, stent migration, paraplegia or death. Angiographic exclusion was complete in all 4 patients. CT scans at a mean follow-up of 11+/-5 months showed complete healing of the aortic wall in all patients. CONCLUSIONS: For stable acute BAI, endovascular stent-graft repair is feasible and safe, and is an effective therapeutic alternative to open surgery. Because of the normal proximal and distal wall in aortic injuries, endoluminal treatment might be the therapy of choice in the near future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hybrid treatment of aortic aneurysms is indicated in patients having the ostia of supra aortic or visceral branches taken in to the aneurysm. Indeed, these lesions are not eligible for classic endovascular treatment because the existing endoprostheses cannot provide perfusion of the side branches without inducing major endoleaks. The surgical technique consists of 2 steps: firstly, a by-pass between normal aorta and the major aortic branches involved in the aneurysm is performed to guarantee the perfusion of the organs such as brain, bowel, and after endoprosthesis deployment. Secondly, the endoprosthesis is deployed using the classical technique to isolate the aneurysm. The hybrid approach provides safe and reliable treatment of complex aortic aneurysms with mortality and morbidity rate far below the classical open surgery.