368 resultados para Eletrodos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the recent progress in the development of polymeric membranes for ion-selective electrodes. The importance of knowing the mechanism of potential development in membranes for ion-selective electrodes to reach lower detection limits and improve selectivity are discussed. Recent advances and future trends of research on ion-selective electrodes are also reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potentiality of the use of ultrasound radiation in association with a boron-doped diamond electrode was evaluated on the voltammetric determination of the pesticide carbaryl. Improvements in the sensitivity, limit of detection and reproducibility of the measurements were observed due to both, the enhancement of mass transport and the cleaning of the electrode surface provided by ultrasound. Satisfactory recovery levels for carbaryl in pure water (96-98%) and pineapple juice (89-92%) for quiescent and sonovoltammetric methodologies were obtained. These methodologies can be alternative tools for the analyses of pesticides in fruit samples, mainly the insonated condition that improve the analytical performance and dispense intermediary cleanings of the electrode surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present review paper describes the main features of nickel hydroxide modified electrodes covering its structural and electrochemical behavior and the newest advances promoted by nanostructured architectures. Important aspects such as synthetic procedures and characterization techniques such as X-Ray diffraction, Raman and Infrared spectroscopy, Electronic Microscopy and many others are detailed herein. The most important aspect concerning nickel hydroxide is related to its great versatility covering different fields in electrochemical-based devices such as batteries, electrocatalytic systems and electrochromic electrodes, the fundamental issues of these devices are also commented. Finally, some of the newest advances achieved in each field by the incorporation of nanomaterials will be shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ossificação da cóclea, decorrente principalmente de meningite, impede a inserção completa do implante coclear convencional. Os implantes com 2 feixes de eletrodos mais curtos do que o convencional foram desenvolvidos especialmente para cócleas ossificadas. Porém, durante essa cirurgia há um grande risco de lesão da artéria carótida interna (ACI). Portanto, a medida da profundidade das cocleostomias para inserir os dois feixes de eletrodos aumentaria a segurança desse procedimento. OBJETIVOS: 1) Obter as distâncias entre as cocleostomias e a ACI em ossos temporais de cadáver; 2) Confeccionar instrumento que possa ser usado na cirurgia de implante coclear com 2 feixes de eletrodos. FORMA DE ESTUDO: Experimental prospectivo. MATERIAL E MÉTODO: Em 21 ossos de cadáveres foi realizada: 1) mastoidectomia cavidade aberta; 2) cocleostomias nos giros basal e médio da cóclea; 3) identificação da ACI; 4) medida da distância entre as cocleostomias e a artéria. RESULTADOS: A medida média ± desvio padrão obtida para o túnel superior foi 8,2 ± 1,1mm e para o túnel inferior foi 8,1± 1,3mm. A menor distância encontrada foi 6,5mm para o túnel superior e 6,0mm para o túnel inferior. CONCLUSÃO: Apesar dos parâmetros calculados concluímos que a melhor medida para ser considerada na confecção do instrumento cirúrgico serão as mínimas medidas obtidas em cada um dos giros cocleares, pois é a maneira mais segura para evitar a lesão da ACI, que pode ser fatal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemically modified electrodes (CMEs) have been subject of considerable attention since its inception about 23 years ago. CMEs result of a deliberate immobilization of a modifier agent onto the electrode surface obtained through chemical reactions, chemisorption, composite formation or polymer coating. This immobilization seeks transfer the physicochemical properties of the modifier to the electrode surface and thus to dictate and control the behavior of the electrode/solution interface. In recent years the interest in CMEs has increased particularly to enhance the sensitivity and/or the selectivity of electroanalytical techniques. In general higher sensitivity and/or selectivity may be achieved by exploiting one or more of the following phenomena: electrocatalysis, preconcentration and interferents exclusion. This paper deals with the application of CMEs in electroanalysis, including a brief presentation of the more general procedures that have been employed for the modification of electrode surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of the kinetics of electrocatalytic reactions on well oriented single crystal surfaces have demonstrated the influence of surface structure on the rate and mechanisms of many electrochemical processes. The preparation and characterization of these surfaces is the first step in this type of studies. In this paper, a methodology employed in order to ensure the quality and cleanliness of single crystals and their utilization as rotating electrodes is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the construction and performance of homemade electrodes for voltammetric purpose using cheap materials, like pipette tips and asbestos fiber. A good cost-to-benefit relation makes this devices specially designed for student use, expecting to improve the broadcasting of electroanalytical methods in Brazilian schools.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A review dealing with the use of screen-printing technology to manufacture disposable electrodes is presented, covering in details virtually all the publications in the area up to early 1997 and including 206 references. The elements and different strategies on constructing modified electrodes are highlighted. Commercial and Home-made ink recipes are discussed. Microelectrode arrays, built by the combination of photostructuring and screen-printing technologies to the mass production of advanced disposable sensors, are also discussed. Future research trends are predicted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple flow cell for potentiometric detection is described. It was assembled by making use of two perspex pieces fixed together by means of four screws, and allow the connection of plane membrane conventional electrodes to flow system. Details about its construction are presented. The device performance was evaluated by making use of a cyanide ion-selective electrode. The relative standard deviation was about 0.5% with a detection limit of 8.0 x 10-6 mol CN- dm-3. Under experimental conditions, the linear range was 10-5 to10-2 mol dm-3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first studies about DNA electrochemistry appeared at the end of the fifties. The voltammetric techniques became important tool for the DNA conformational analysis, producing evidences about DNA double helix polimorphism. The new techniques based on electrodes modification with nucleic acid enlarged the use of the electrochemical methods on the DNA research. DNA electrochemical biosensors are able to detect specific sequences of DNA bases, becoming important alternative for the diagnosis of disease, as well as in the carcinogenic species determination. Besides, the use of DNA biosensors in the mechanism study of biological drug actions can be useful for drug design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potentiometric amalgam electrodes of lead, cadmium, and zinc are proposed to study the complexation properties of commercial and river sediment humic acids. The copper complexation properties of both humic acids were studied in parallel using the solid membrane copper ion-selective electrode (Cu-ISE). The complexing capacity and the averaged conditional stability constants were determined at pH 6.00 ± 0.05 in medium of 2x10-2 mol L-1 sodium nitrate, using the Scatchard method. The lead and cadmium amalgam electrodes presented a Nernstian behavior from 1x10-5 to 1x10-3 moles L-1 of total metal concentration, permitting to perform the complexation studies using humic acid concentrations around of 20 to 30 mg L-1, that avoids colloidal aggregation. The zinc amalgam electrode showed a subnernstian linear response in the same range of metal concentrations. The Scatchard graphs for both humic acids suggested two classes of binding sites for lead and copper and one class of binding site for zinc and cadmium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design of a simple apparatus that periodically switches off both working and auxiliary electrodes short-circuiting them for a couple of seconds. Depolarization takes place and the initial current is re-established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is designed to divulge some tests found in books, articles and international technical standards, by means of which it is possible to evaluate the performance of reference electrode widely used in potentiometric and voltammetric methods. The reference potential (Eref), junction resistance (Rj), the ability of keeping up the potential when current is flowing (polarizability), and of generating junction potentials (Ej) are applied to some commercial electrodes. The results obtained are amply discussed and some corrective procedures are suggested when the electrode fails.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study of the kinetics of oxygen evolution in alkaline conditions from ceramic films of Mn2O3 supported on stainless steel was carried out. This study has been done through the determination of transfer coefficients, Tafel slopes and exchange currents using potentiodynamic and quasi-potentiostatic measurements. The activation energy was determined as a function of the overpotential and, additionally, the electrode active surface was estimated. The results are consistent with data already published for other electrodes, implying that the methods used in this work were reliable and precise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perfluoro and sulfonated ion-exchange polymers are recognized as a very useful material for various mechanistic studies and applications in electrochemistry. These polymers are characterized by high equivalent weights and by a low number of ion-exchange sites interposed between long organic chains. The solubility enables a preparation of stable polyelectrolyte films on the electrode surface. Examples of the determination of trace metals and organic componds in real environmental samples are presented.