902 resultados para EQUASS Assurance
Resumo:
Purpose – The paper examines from a practitioner’s perspective the European Quality in Social Services (EQUASS) Assurance standard, a certification programme for European social service organisations to implement a sector-specific Quality Management System. In particular, it analyses the adoption motives, the internalisation of the standard, the impacts, the satisfaction and the renew intentions. Design/methodology/approach – This study uses a cross-sectional, questionnaire-based survey methodology. From the 381 organisations emailed, 196 responses coming from eight different European countries were considered valid (51.4%). Data from closed-ended questions were analysed using simple descriptive statistical techniques. Content analysis was employed to analyse practitioner’s comments to open-ended questions. Findings – It shows that social service providers typically implement the certification for internal reasons, and internalise EQUASS principles and practices in daily usage. EQUASS Assurance produces benefits mainly at the operational and customer levels, whereas its main pitfalls include increased workload and bureaucracy. The majority of respondents (85.2%) are very satisfied or satisfied with the certification, suggesting that it meets their expectations. Certification renewal intentions are also high but some respondents report that the final decision depends on several factors. The insights gained through the qualitative data are also described. Practical implications – It can be helpful to managers, consultants and Local License Holders working (or planning to work) with this standard. It can inform the work of the EQUASS Technical Working Group in the forthcoming revision of the standard. Originality/value – This is the largest survey conducted so far about EQUASS Assurance in terms of number of respondents, participating countries and topics covered.
Resumo:
Institutional research can be defined as "the activity in which the research effort of an academic institution is directed at the solution of its own problems and to the enhancement of its own performance" (Woodward, 1993, p. 113). This paper describes and reflects on an attempt at the University of Queensland to address the need for course quality appraisal for improvement. The strategy, Continuous Curriculum Review (CCR) is simply an attempt to trial and promote regular comprehensive data collection for developing 'snapshot' views of whole curricula so that decisions about what to change and what to change first can be made in an empirically defensible and timely manner. The strategy and reporting protocols that were developed are described, and the costs and benefits of engaging in this kind of data gathering exercise for quality assurance and quality enhancement purposes are discussed.
Resumo:
O presente estudo tem por finalidade analisar o Centro de Reabilitação Profissional de Gaia (CRPG), enquanto associação que exerce a sua missão tendo por base a responsabilidade social. O CRPG foi a primeira associação em Portugal a apresentar a preocupação de demonstrar a qualidade das práticas que exerce, através da Certificação da Excelência dos Serviços Sociais. Esta certificação é efetuada segundo o sistema European Quality in Social Services (EQUASS), o qual permite o reconhecimento, garantia e certificação da qualidade às organizações que atuam no âmbito dos serviços sociais, tais como a reabilitação, a formação profissional, a assistência e cuidados às pessoas em situação de fragilidade social. Salienta-se a este propósito o cariz voluntário para a aquisição deste tipo de certificação, o que comprova, além de outras preocupações, como a garantia da qualidade dos serviços prestado, a conduta socialmente responsável do CRPG.
Resumo:
Objectives - Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. Methods - Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified were reviewed and a selection was compared for type of guidance (clinical/technical), technology and proposed QA methodologies focusing on dose and image quality (IQ) performance assessment. Results - Fourteen protocols (targeted at conventional and digital mammography) were reviewed. All included recommendations for testing acquisition, processing and display systems associated with mammographic equipment. All guidance reviewed highlighted the importance of dose assessment and testing the Automatic Exposure Control (AEC) system. Recommended tests for assessment of IQ showed variations in the proposed methodologies. Recommended testing focused on assessment of low-contrast detection, spatial resolution and noise. QC of image display is recommended following the American Association of Physicists in Medicine guidelines. Conclusions - The existing QA guidance for mammography is derived from key documents (American College of Radiology and European Union guidelines) and proposes similar tests despite the variations in detail and methodologies. Studies reported on QA data should provide detail on experimental technique to allow robust data comparison. Countries aiming to implement a mammography/QA program may select/prioritise the tests depending on available technology and resources.
Resumo:
The oxidative behaviour of fluoxetine was studied at a glassy carbon electrode in various buffer systems and at different pH using cyclic, differential pulse and square wave voltammetry. A new square wave voltammetric method suitable for the quality control of fluoxetine in commercial formulations has been developed using a borate pH 9 buffer solution as supporting electrolyte. Under optimized conditions, a linear response was obtained in the range 10 to 16 μM with a detection limit of 1.0 μM. Validation parameters such as sensitivity, precision and accuracy were evaluated. The proposed method was successfully applied to the determination of fluoxetine in pharmaceutical formulations. The results were statistically compared with those obtained by the reference high-performance liquid chromatographic method. No significant differences were found between the methods.
Resumo:
The present Working Project aims at studying the topic of assurance mapping in a specific organizational context of a Portuguese retail company. For this purpose, an assurance map framework was designed to support the decision making process of stakeholders, through the delivery of comfort concerning risks, operations and control. In the end, the framework was successfully implemented for the process sourcing of goods in two business units of the company. Although, further implementation of the framework proved not to be feasible during the project’s timespan, it is expected to occur in the near future.
Resumo:
Objective: We aimed to critically evaluate the importance of quality control (QC) and quality assurance (QA) strategies in the routine work of uterine cervix cytology. Study Design: We revised all the main principles of QC and QA that are already being implemented worldwide and then discussed the positive aspects and limitations of these as well as proposing alternatives when pertinent. Results: A literature review was introduced after highlighting the main historical revisions, and then a critical evaluation of the principal innovations in screening programmes was conducted, with recommendations being postulated. Conclusions: Based on the analysed data, QC and QA are two essential arms that support the quality of a screening programme.
Resumo:
INTRODUCTION: EORTC trial 22991 was designed to evaluate the addition of concomitant and adjuvant short-term hormonal treatments to curative radiotherapy in terms of disease-free survival for patients with intermediate risk localized prostate cancer. In order to assess the compliance to the 3D conformal radiotherapy protocol guidelines, all participating centres were requested to participate in a dummy run procedure. An individual case review was performed for the largest recruiting centres as well. MATERIALS AND METHODS: CT-data of an eligible prostate cancer patient were sent to 30 centres including a description of the clinical case. The investigator was requested to delineate the volumes of interest and to perform treatment planning according to the protocol. Thereafter, the investigators of the 12 most actively recruiting centres were requested to provide data on five randomly selected patients for an individual case review. RESULTS: Volume delineation varied significantly between investigators. Dose constraints for organs at risk (rectum, bladder, hips) were difficult to meet. In the individual case review, no major protocol deviations were observed, but a number of dose reporting problems were documented for centres using IMRT. CONCLUSIONS: Overall, results of this quality assurance program were satisfactory. The efficacy of the combination of a dummy run procedure with an individual case review is confirmed in this study, as none of the evaluated patient files harboured a major protocol deviation. Quality assurance remains a very important tool in radiotherapy to increase the reliability of the trial results. Special attention should be given when designing quality assurance programs for more complex irradiation techniques.
Resumo:
Le projet "prestations de l'assurance-maladie sociale" est l'un des projets partiels élaborés par l'Office fédéral des assurances sociales (OFAS) dans le cadre de l'analyse des effets de la LAMal. Deux approches complémentaires sont adoptées pour répondre à la question du caractère suffisant du "catalogue" suisse des prestations à charge de l'assurance-maladie sociale: d'une part, la comparaison des "catalogues" des prestations remboursées en Suisse et à l'étranger et, d'autre part, l'examen de la couverture par le "catalogue" des prestations de problèmes de santé utilisés comme traceurs. [Table des matières] 1.1. Contexte. 1.2. Définition et limites du mandat. 1.3. Le "catalogue" des prestations : composition actuelle, participation d'autres assurances sociales et des pouvoirs publics. 1.4. Approches méthodologiques : comparaison internationale, étude de conditions-traceurs. 2. Analyse par comparaison internationale. 2.1. Recherche de documentation et collaborations. 2.2. Résultats : Suisse, France, Allemagne, Israël, Pays-Bas, Luxembourg, comparaison internationale des prestations générales, par catégorie, et des prestations spéciales. 3. Analyse par conditions traceurs. 3.1. Stratégie de la recherche documentaire. 3.2. Critères de choix des documents. 3.3. Variations méthodologiques et particularités. 3.4. Résultats : Accident vasculaire cérébral (ischémique), fracture de hanche, obésité, leucémie aigüe (LA), grossesse normale et nouveau-né en bonne santé. 3.5. Discussion.
Resumo:
The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.
Resumo:
A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography quality.