900 resultados para EPITHERMAL NEUTRON-SPECTRUM


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Zr-Au set for monitoring the thermal and epithermal neutron fluence rate and the epithermal spectrum parameter a is not always practicable for routine application of INAA in well-thermalized facilities. An alternative set consisting of Cr, Au and Mo provides values for the thermal neutron fluence rate, f and alpha that are not significantly different from those found via the Zr-Au method and the Cd-covered Zr-method. The IRMM standard SMELS-II was analyzed using the (Au-Cr-Mo) monitor and a good agreement was obtained. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We measured the K-41 thermal neutron absorption and resonance integral cross sections after the irradiation of KNO3 samples near the core of the IEA-R1 IPEN pool-type research reactor. Bare and cadmium-covered targets were irradiated in pairs with Au-Al alloy flux-monitors. The residual activities were measured by gamma-ray spectroscopy with a HPGe detector, with special care to avoid the K-42 decay beta(-) emission effects on the spectra. The gamma-ray self-absorption was corrected with the help of MCNP simulations. We applied the Westcott formalism in the average neutron flux determination and calculated the depression coefficients for thermal and epithermal neutrons due to the sample thickness with analytical approximations. We obtained 1.57(4) and 1.02(4) b, for thermal and resonance integral cross sections, respectively, with correlation coefficient equal to 0.39.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ground state thermal neutron cross section and the resonance integral for the (165)Ho(n, gamma)(166)Ho reaction in thermal and 1/E regions, respectively, of a thermal reactor neutron spectrum have been measured experimentally by activation technique. The reaction product, (166)Ho in the ground state, is gaining considerable importance as a therapeutic radionuclide and precisely measured data of the reaction are of significance from the fundamental point of view as well as for application. In this work, the spectrographically pure holmium oxide (Ho(2)O(3)) powder samples were irradiated with and without cadmium covers at the IEA-RI reactor (IPEN, Sao Paulo), Brazil. The deviation of the neutron spectrum shape from 1/E law was measured by co-irradiating Co, Zn, Zr and Au activation detectors with thermal and epithermal neutrons followed by regression and iterative procedures. The magnitudes of the discrepancies that can occur in measurements made with the ideal 1/E law considerations in the epithermal range were studied. The measured thermal neutron cross section at the Maxwellian averaged thermal energy of 0.0253 eV is 59.0 +/- 2.1 b and for the resonance integral 657 +/- 36b. The results are measured with good precision and indicated a consistency trend to resolve the discrepant status of the literature data. The results are compared with the values in main libraries such as ENDF/B-VII, JEF-2.2 and JENDL-3.2, and with other measurements in the literature.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this work is to provide a precise and accurate measurement of the 238U(n,gamma) reaction cross-section. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behaviour of the reactor core. In particular, fast neutron reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region inconsistencies between the existing measurements are present up to 15%, and the most recent evaluations disagree each other. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross-section of 238U should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were scheduled within the ANDES project within the 7th Framework Project of the European Commission. The results of one of the 238U(n,gamma) measurement performed at the n_TOF CERN facility are presented in this work, carried out with a detection system constituted of two liquid scintillators. The very accurate cross section from this work is compared with the results obtained from the other measurement performed at the n_TOF facility, which exploit a different and complementary detection technique. The excellent agreement between the two data-sets points out that they can contribute to the reduction of the cross section uncertainty down to the required 1-3%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Neutron capture effects in meteorites and lunar surface samples have been successfully used in the past to study exposure histories and shielding conditions. In recent years, however, it turned out that neutron capture effects produce a nuisance for some of the short-lived radionuclide systems. The most prominent example is the 182Hf-182W system in iron meteorites, for which neutron capture effects lower the 182W/184W ratio, thereby producing too old apparent ages. Here, we present a thorough study of neutron capture effects in iron meteorites, ordinary chondrites, and carbonaceous chondrites, whereas the focus is on iron meteorites. We study in detail the effects responsible for neutron production, neutron transport, and neutron slowing down and find that neutron capture in all studied meteorite types is not, as usually expected, exclusively via thermal neutrons. In contrast, most of the neutron capture in iron meteorites is in the epithermal energy range and there is a significant contribution from epithermal neutron capture even in stony meteorites. Using sophisticated particle spectra and evaluated cross section data files for neutron capture reactions we calculate the neutron capture effects for Sm, Gd, Cd, Pd, Pt, and Os isotopes, which all can serve as neutron-dose proxies, either in stony or in iron meteorites. In addition, we model neutron capture effects in W and Ag isotopes. For W isotopes, the GCR-induced shifts perfectly correlate with Os and Pt isotope shifts, which therefore can be used as neutron-dose proxies and permit a reliable correction. We also found that GCR-induced effects for the 107Pd-107Ag system can be significant and need to be corrected, a result that is in contrast to earlier studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work is aimed to present the main differences of nuclear data uncertainties among three different nuclear data libraries: EAF-2007, EAF-2010 and SCALE-6.0, under different neutron spectra: LWR, ADS and DEMO (fusion). To take into account the neutron spectrum, the uncertainty data are collapsed to onegroup. That is a simple way to see the differences among libraries for one application. Also, the neutron spectrum effect on different applications can be observed. These comparisons are presented only for (n,fission), (n,gamma) and (n,p) reactions, for the main transuranic isotopes (234,235,236,238U, 237Np, 238,239,240,241Pu, 241,242m,243Am, 242,243,244,245,246,247,248Cm, 249Bk, 249,250,251,252Cf). But also general comparisons among libraries are presented taking into account all included isotopes. In other works, target accuracies are presented for nuclear data uncertainties; here, these targets are compared with uncertainties on the above libraries. The main results of these comparisons are that EAF-2010 has reduced their uncertainties for many isotopes from EAF-2007 for (n,gamma) and (n,fission) but not for (n,p); SCALE-6.0 gives lower uncertainties for (n,fission) reactions for ADS and PWR applications, but gives higher uncertainties for (n,p) reactions in all applications. For the (n,gamma) reaction, the amount of isotopes which have higher uncertainties is quite similar to the amount of isotopes which have lower uncertainties when SCALE-6.0 and EAF-2010 are compared. When the effect of neutron spectra is analysed, the ADS neutron spectrum obtained the highest uncertainties for (n,gamma) and (n,fission) reactions of all libraries.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Monte Carlo calculations were carried out to characterize the neutron field produced by the calibration neutron sources of the Neutron Standards Laboratory at the Research Center for Energy, Environment and Technology (CIEMAT) in Spain. For 241AmBe and 252Cf neutron sources, the neutron spectra, the ambient dose equivalent rates and the total neutron fluence rates were estimated. In the calibration hall, there are several items that modify the neutron field. To evaluate their effects different cases were used, from point-like source in vacuum up to the full model. Additionally, using the full model, the neutron spectra were estimated to different distances along the bench; with these spectra, the total neutron fluence and the ambient dose equivalent rates were calculated. The hall walls induce the largest changes in the neutron spectra and the respective integral quantities. The free-field neutron spectrum is modified due the room return effect.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An epithermal neutron imager based on detecting alpha particles created via boron neutron capture mechanism is discussed. The diagnostic mainly consists of a mm thick Boron Nitride (BN) sheet (as an alpha converter) in contact with a non-borated cellulose nitride film (LR115 type-II) detector. While the BN absorbs the neutrons in the thermal and epithermal ranges, the fast neutrons register insignificantly on the detector due to their low neutron capture and recoil cross-sections. The use of solid-state nuclear track detectors (SSNTD), unlike image plates, micro-channel plates and scintillators, provide safeguard from the x-rays, gamma-rays and electrons. The diagnostic was tested on a proof-of-principle basis, in front of a laser driven source of moderated neutrons, which suggests the potential of using this diagnostic (BN+SSNTD) for dosimetry and imaging applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the Bonner spheres spectrometer neutron spectrum is obtained through an unfolding procedure. Monte Carlo methods, Regularization, Parametrization, Least-squares, and Maximum Entropy are some of the techniques utilized for unfolding. In the last decade methods based on Artificial Intelligence Technology have been used. Approaches based on Genetic Algorithms and Artificial Neural Networks have been developed in order to overcome the drawbacks of previous techniques. Nevertheless the advantages of Artificial Neural Networks still it has some drawbacks mainly in the design process of the network, vg the optimum selection of the architectural and learning ANN parameters. In recent years the use of hybrid technologies, combining Artificial Neural Networks and Genetic Algorithms, has been utilized to. In this work, several ANN topologies were trained and tested using Artificial Neural Networks and Genetically Evolved Artificial Neural Networks in the aim to unfold neutron spectra using the count rates of a Bonner sphere spectrometer. Here, a comparative study of both procedures has been carried out.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The uncertainties on the isotopic composition throughout the burnup due to the nuclear data uncertainties are analysed. The different sources of uncertainties: decay data, fission yield and cross sections; are propagated individually, and their effect assessed. Two applications are studied: EFIT (an ADS-like reactor) and ESFR (Sodium Fast Reactor). The impact of the uncertainties on cross sections provided by the EAF-2010, SCALE6.1 and COMMARA-2.0 libraries are compared. These Uncertainty Quantification (UQ) studies have been carried out with a Monte Carlo sampling approach implemented in the depletion/activation code ACAB. Such implementation has been improved to overcome depletion/activation problems with variations of the neutron spectrum.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology. In this thesis, a measurement of the proton recoil spectrum with the spectrometer aSPECT is described. From this spectrum the antineutrino-electron angular correlation coefficient a can be derived. In our first beam time at the FRM II in Munich, background instabilities prevented us from presenting a new value for a. In the latest beam time at the ILL in Grenoble, the background has been reduced sufficiently. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The aim of the latest beam time was a new value for a with an error well below the present literature value of 4%. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, too high to determine a meaningful result. This thesis focused on the investigation of different systematic effects. With the knowledge of the systematics gained in this thesis, we are able to improve aSPECT to perform a 1% measurement of a in a further beam time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The relatively large number of nearby radio-quiet and thermally emitting isolated neutron stars (INSs) discovered in the ROSAT All-Sky Survey, dubbed the ""Magnificent Seven"", suggests that they belong to a formerly neglected major component of the overall INS population. So far, attempts to discover similar INSs beyond the solar vicinity failed to confirm any reliable candidate. The good positional accuracy and soft X-ray sensitivity of the EPIC cameras onboard the XMM-Newton satellite allow us to efficiently search for new thermally emitting INSs. We used the 2XMMp catalogue to select sources with no catalogued candidate counterparts and with X-ray spectra similar to those of the Magnificent Seven, but seen at greater distances and thus undergoing higher interstellar absorptions. Identifications in more than 170 astronomical catalogues and visual screening allowed us to select fewer than 30 good INS candidates. In order to rule out alternative identifications, we obtained deep ESO-VLT and SOAR optical imaging for the X-ray brightest candidates. We report here on the optical follow-up results of our search and discuss the possible nature of 8 of our candidates. A high X-ray-to-optical flux ratio together with a stable flux and soft X-ray spectrum make the brightest source of our sample, 2XMM J104608.7-594306, a newly discovered thermally emitting INS. The X-ray source 2XMM J010642.3+005032 has no evident optical counterpart and should be further investigated. The remaining X-ray sources are most probably identified with cataclysmic variables and active galactic nuclei, as inferred from the colours and flux ratios of their likely optical counterparts. Beyond the finding of new thermally emitting INSs, our study aims at constraining the space density of this Galactic population at great distances and at determining whether their apparently high density is a local anomaly or not.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the last decade, X-ray observations have revealed the existence of several classes of isolated neutron stars (INSs) which are radio-quiet or exhibit radio emission with properties much at variance with those of ordinary radio pulsars. The identification of new sources is crucial in order to understand the relations among the different classes and to compare observational constraints with theoretical expectations. A recent analysis of the 2XMMp catalogue provided fewer than 30 new thermally emitting INS candidates. Among these, the source 2XMM J104608.7-594306 appears particularly interesting because of the softness of its X-ray spectrum, kT = 117 +/- 14 eV and N(H) = (3.5 +/- 1.1) x 10(21) cm(-2) (3 sigma), and of the present upper limits in the optical, m(B) greater than or similar to 26, m(V) greater than or similar to 25.5 and m(R) greater than or similar to 25 (98.76% confidence level), which imply a logarithmic X-ray-to-optical flux ratio log(F(X)/F(V)) greater than or similar to 3.1, corrected for absorption. We present the X-ray and optical properties of 2XMM J104608.7-594306 and discuss its nature in the light of two possible scenarios invoked to explain the X-ray thermal emission from INSs: the release of residual heat in a cooling neutron star, as in the seven radio-quiet ROSAT-discovered INSs, and accretion from the interstellar medium. We find that the present observational picture of 2XMM J104608.7-594306 is consistent with a distant cooling INS with properties in agreement with the most up-to-date expectations of population synthesis models: it is fainter, hotter and more absorbed than the seven ROSAT sources and possibly located in the Carina Nebula, a region likely to harbour unidentified cooling neutron stars. The accretion scenario, although not entirely ruled out by observations, would require a very slow (similar to 10 km s(-1)) INS accreting at the Bondi-Hoyle rate.