242 resultados para ENTRAINMENT
Resumo:
Rectangular dropshafts, commonly used in sewers and storm water systems, are characterised by significant flow aeration. New detailed air-water flow measurements were conducted in a near-full-scale dropshaft at large discharges. In the shaft pool and outflow channel, the results demonstrated the complexity of different competitive air entrainment mechanisms. Bubble size measurements showed a broad range of entrained bubble sizes. Analysis of streamwise distributions of bubbles suggested further some clustering process in the bubbly flow although, in the outflow channel, bubble chords were in average smaller than in the shaft pool. A robust hydrophone was tested to measure bubble acoustic spectra and to assess its field application potential. The acoustic results characterised accurately the order of magnitude of entrained bubble sizes, but the transformation from acoustic frequencies to bubble radii did not predict correctly the probability distribution functions of bubble sizes.
Resumo:
A hydraulic jump is characterized by strong energy dissipation and mixing, large-scale turbulence, air entrainment, waves and spray. Despite recent pertinent studies, the interaction between air bubbles diffusion and momentum transfer is not completely understood. The objective of this paper is to present experimental results from new measurements performed in rectangular horizontal flume with partially-developed inflow conditions. The vertical distributions of void fraction and air bubbles count rate were recorded for inflow Froude number Fr1 in the range from 5.2 to 14.3. Rapid detrainment process was observed near the jump toe, whereas the structure of the air diffusion layer was clearly observed over longer distances. These new data were compared with previous data generally collected at lower Froude numbers. The comparison demonstrated that, at a fixed distance from the jump toe, the maximum void fraction Cmax increases with the increasing Fr1. The vertical locations of the maximum void fraction and bubble count rate were consistent with previous studies. Finally, an empirical correlation between the upper boundary of the air diffusion layer and the distance from the impingement point was provided.
Resumo:
A hydraulic jump is characterised by strong energy dissipation and air entrainment. In the present study, new air-water flow measurements were performed in hydraulic jumps with partially-developed flow conditions in relatively large-size facilities with phase-detection probes. The experiments were conducted with identical Froude numbers, but a range of Reynolds numbers and relative channel widths. The results showed drastic scale effects at small Reynolds numbers in terms of void fraction and bubble count rate distributions. The void fraction distributions implied comparatively greater detrainment at low Reynolds numbers leading to a lesser overall aeration of the jump roller, while dimensionless bubble count rates were drastically lower especially in the mixing layer. The experimental results suggested also that the relative channel width had little effect on the air-water flow properties for identical inflow Froude and Reynolds numbers.
Resumo:
In an open channel, the transition from super- to sub-critical flow is a flow singularity (the hydraulic jump) characterised by a sharp rise in free-surface elevation, strong turbulence and air entrainment in the roller. A key feature of the hydraulic jump flow is the strong free-surface aeration and air-water flow turbulence. In the present study, similar experiments were conducted with identical inflow Froude numbers Fr1 using a geometric scaling ratio of 2:1. The results of the Froude-similar experiments showed some drastic scale effects in the smaller hydraulic jumps in terms of void fraction, bubble count rate and bubble chord time distributions. Void fraction distributions implied comparatively greater detrainment at low Reynolds numbers yielding some lesser aeration of the jump roller. The dimensionless bubble count rates were significantly lower in the smaller channel, especially in the mixing layer. The bubble chord time distributions were quantitatively close in both channels, and they were not scaled according to a Froude similitude. Simply the hydraulic jump remains a fascinating two-phase flow motion that is still poorly understood.
Resumo:
The nonlinear response of a chaotic system to a chaotic variation in a system parameter is investigated experimentally. Clear experimental evidence of frequency entrainment of the chaotic oscillations is observed. We show that analogous to the frequency locking between coupled periodic oscillations, this effect is generic for coupled chaotic systems.
Effect of frother type and concentration on the water recovery and entrainment recovery relationship
Resumo:
A study was undertaken to determine the effects of five industrial frothers on the relationship between entrainment recovery and water recovery. The experiments were conducted using a Batequip rectangular 60-L steel flotation cell that was run in parallel with the first cell in a copper/silver prefloat rougher circuit. The concentration of the frothers ranged from 2.5 to 8.4 g/t. The experiments were repeated at three different froth depths. A power function was found to fit this relationship with no discontinuity in the relationship caused by the changes in frother type and concentration and froth depth.
Resumo:
The influence of near-bed sorting processes on heavy mineral content in suspension is discussed. Sediment concentrations above a rippled bed of mixed quartz and heavy mineral sand were measured under regular nonbreaking waves in the laboratory. Using the traditional gradient diffusion process, settling velocity would be expected to strongly affect sediment distribution. This was not observed during present trials. In fact, the vertical gradients of time-averaged suspension concentrations were found to be similar for the light and heavy minerals, despite their different settling velocities. This behavior implies a convective rather than diffusive distribution mechanism. Between the nonmoving bed and the lowest suspension sampling point, fight and heavy mineral concentration differs by two orders of magnitude. This discrimination against the heavy minerals in the pickup process is due largely to selective entrainment at the ripple face. Bed-form dynamics and the nature of quartz suspension profiles are found to be little affected by the trialed proportion of overall heavy minerals in the bed (3.8-22.1%).
Resumo:
We report on the onset of fluid entrainment when a contact line is forced to advance over a dry solid of arbitrary wettability. We show that entrainment occurs at a critical advancing speed beyond which the balance between capillary, viscous, and contact-line forces sustaining the shape of the interface is no longer satisfied. Wetting couples to the hydrodynamics by setting both the morphology of the interface at small scales and the viscous friction of the front. We find that the critical deformation that the interface can sustain is controlled by the friction at the contact line and the viscosity contrast between the displacing and displaced fluids, leading to a rich variety of wetting-entrainment regimes. We discuss the potential use of our theory to measure contact-line forces using atomic force microscopy and to study entrainment under microfluidic conditions exploiting colloid-polymer fluids of ultralow surface tension.
Resumo:
To permit the tracking of turbulent flow structures in an Eulerian frame from single-point measurements, we make use of a generalization of conventional two-dimensional quadrant analysis to three-dimensional octants. We characterize flow structures using the sequences of these octants and show how significance may be attached to particular sequences using statistical mull models. We analyze an example experiment and show how a particular dominant flow structure can be identified from the conditional probability of octant sequences. The frequency of this structure corresponds to the dominant peak in the velocity spectra and exerts a high proportion of the total shear stress. We link this structure explicitly to the propensity for sediment entrainment and show that greater insight into sediment entrainment can be obtained by disaggregating those octants that occur within the identified macroturbulence structure from those that do not. Hence, this work goes beyond critiques of Reynolds stress approaches to bed load entrainment that highlight the importance of outward interactions, to identifying and prioritizing the quadrants/octants that define particular flow structures. Key Points <list list-type=''bulleted'' id=''jgrf20196-list-0001''> <list-item id=''jgrf20196-li-0001''>A new method for analysing single point velocity data is presented <list-item id=''jgrf20196-li-0002''>Flow structures are identified by a sequence of flow states (termed octants) <list-item id=''jgrf20196-li-0003''>The identified structure exerts high stresses and causes bed-load entrainment
Resumo:
Thèse de doctorat réalisé en cotutelle avec l'Université catholique de Louvain, Belgique (Faculté de médecine, Institut de Neuroscience)
An evaluation of boundary-layer depth, inversion and entrainment parameters by large-eddy simulation
Resumo:
The behaviour of stationary, non-passive plumes can be simulated in a reasonably simple and accurate way by integral models. One of the key requirements of these models, but also one of their less well-founded aspects, is the entrainment assumption, which parameterizes turbulent mixing between the plume and the environment. The entrainment assumption developed by Schatzmann and adjusted to a set of experimental results requires four constants and an ad hoc hypothesis to eliminate undesirable terms. With this assumption, Schatzmann’s model exhibits numerical instability for certain cases of plumes with small velocity excesses, due to very fast radius growth. The purpose of this paper is to present an alternative entrainment assumption based on a first-order turbulence closure, which only requires two adjustable constants and seems to solve this problem. The asymptotic behaviour of the new formulation is studied and compared to previous ones. The validation tests presented by Schatzmann are repeated and it is found that the new formulation not only eliminates numerical instability but also predicts more plausible growth rates for jets in co-flowing streams.
Resumo:
We demonstrate that summer precipitation biases in the South Asian monsoon domain are sensitive to increasing the convective parametrisation’s entrainment and detrainment rates in the Met Office Unified Model. We explore this sensitivity to improve our understanding of the biases and inform efforts to improve convective parametrisation. We perform novel targeted experiments in which we increase the entrainment and detrainment rates in regions of especially large precipitation bias. We use these experiments to determine whether the sensitivity at a given location is a consequence of the local change to convection or is a remote response to the change elsewhere. We find that a local change leads to different mean-state responses in comparable regions. When the entrainment and detrainment rates are increased globally, feedbacks between regions usually strengthen the local responses. We choose two regions of tropical ascent that show different mean-state responses, the western equatorial Indian Ocean and western north Pacific, and analyse them as case studies to determine the mechanisms leading to the different responses. Our results indicate that several aspects of a region’s mean-state, including moisture content, sea surface temperature and circulation, play a role in local feedbacks that determine the response to increased entrainment and detrainment.
Resumo:
The aim of this work was to investigate the effect of the in vitro circadian-like exposure to melatonin [in the presence or absence of insulin (Ins)] on the metabolism and clock gene expression in adipocytes. To simulate the cyclic characteristics of the daily melatonin profile, isolated rat adipocytes were exposed in a circadian-like pattern to melatonin added to the incubating medium for 12 hr (mimicking the night), followed by an equal period without melatonin (mimicking the day) combined or not with Ins. This intermittent incubation was interrupted when four and a half 24-hr cycles were fulfilled. At the end, either during the induced night (melatonin present) or the induced day (melatonin absent), the rates of lipolysis and D-[U-(14)C]-glucose incorporation into lipids were estimated, in addition to the determination of lipogenic [glucose-6-phosphate dehydrogenase and fatty acid synthase (FAS)] and lipolytic (hormone sensitive lipase) enzymes and clock gene (Bmal-1b, Clock, Per-1 and Cry-1) mRNA expression. The leptin release was also measured. During the induced night, the following effects were observed: an increase in the mRNA expression of Clock, Per-1 and FAS; a rise in lipogenic response and leptin secretion; and a decrease in the lipolytic activity. The intermittent exposure of adipocytes to melatonin temporally and rhythmically synchronized their metabolic and hormonal function in a circadian fashion, mimicking what is observed in vivo in animals during the daily light-dark cycle. Therefore, this work helps to clarify the physiological relevance of the circadian pattern of melatonin secretion and its interactions with Ins, contributing to a better understanding of the adipocyte biology.