10 resultados para ELECTROCHEMILUMINESCENCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of electrochemiluminescence (ECL) involves photophysical and electrochemical aspects. Excited states are populated by an electrical stimulus. The most important applications are in the diagnostic field where a number of different biologically-relevant molecules (e.g. proteins and nucleic acids) can be recognized and quantified with a sensitivity and specificity previously not reachable. As a matter of fact the electrochemistry, differently to the classic techniques as fluorescence and chemiluminescence, allows to control the excited state generation spatially and temporally. The two research visits into A. J. Bard electrochemistry laboratories were priceless. Dr. Bard has been one of ECL pioneers, the first to introduce the technique and the one who discovered in 1972 the surprising emission of Ru(bpy)3 2+. I consider necessary to thank by now my supervisors Massimo and Francesco for their help and for giving me the great opportunity to know this unique science man that made me feel enthusiastic. I will never be grateful enough… Considering that the experimental techniques of ECL did not changed significantly in these last years the most convenient research direction has been the developing of materials with new or improved properties. In Chapter I the basics concepts and mechanisms of ECL are introduced so that the successive experiments can be easily understood. In the final paragraph the scopes of the thesis are briefly described. In Chapter II by starting from ECL experimental apparatus of Dr. Bard’s laboratories the design, assembly and preliminary tests of the new Bologna instrument are carefully described. The instrument assembly required to work hard but resulted in the introduction of the new technique in our labs by allowing the continuation of the ECL studies began in Texas. In Chapter III are described the results of electrochemical and ECL studies performed on new synthesized Ru(II) complexes containing tetrazolate based ligands. ECL emission has been investigated in solution and in solid thin films. The effect of the chemical protonation of the tetrazolate ring on ECL emission has been also investigated evidencing the possibility of a catalytic effect (generation of molecular hydrogen) of one of the complexes in organic media. Finally, after a series of preliminary studies on ECL emission in acqueous buffers, the direct interaction with calf thymus DNA of some complexes has been tested by ECL and photoluminescence (PL) titration. In Chapter IV different Ir(III) complexes have been characterized electrochemically and photophysically (ECL and PL). Some complexes were already well-known in literature for their high quantum efficiency whereas the remaining were new synthesized compounds containing tetrazolate based ligands analogous to those investigated in Chapt. III. During the tests on a halogenated complex was unexpectedly evidenced the possibility to follow the kinetics of an electro-induced chemical reaction by using ECL signal. In the last chapter (V) the possibility to use mono-use silicon chips electrodes as ECL analitycal devices is under investigation. The chapter begins by describing the chip structure and materials then a signal reproducibility study and geometry optimization is carried on by using two different complexes. In the following paragraphs is reported in detail the synthesis of an ECL label based on Ru(bpy)3 2+ and the chip functionalization by using a lipoic acid SAM and the same label. After some preliminary characterizations (mass spectroscopy TOF) has been demonstrated that by mean of a simple and fast ECL measurement it’s possible to confirm the presence of the coupling product SAM-label into the chip with a very high sensitivity. No signal was detected from the same system by using photoluminescence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomarkers are biological indicators of human health conditions. Their ultra-sensitive quantification is of paramount importance in clinical monitoring and early disease diagnosis. Biosensors are simple and easy-to-use analytical devices and, in their world, electrochemiluminescence (ECL) is one of the most promising analytical techniques that needs an ever-increasing sensitivity for improving its clinical effectiveness. Scope of this project was the investigation of the ECL generation mechanisms for enhancing the ECL intensity also through the identification of suitable nanostructures. The combination of nanotechnologies, microscopy and ECL has proved to be a very successful strategy to improve the analytical efficiency of ECL in one of its most promising bioanalytical approaches, the bead-based immunoassay. Nanosystems, such as [Ru(bpy)3]2+-dye-doped nanoparticles (DDSNPs) and Bodipy Carbon Nanodots, have been used to improve the sensitivity of ECL techniques thanks to their advantageous and tuneable properties, reaching a signal increase of 750% in DDSNPs-bead-based immunoassay system. In this thesis, an investigation of size and distance effects on the ECL mechanisms was carried out through the innovative combination of ECL microscopy and electrochemical mapping of radicals. It allowed the discovery of an unexpected and highly efficient mechanistic path for ECL generation at small distances from the electrode surface. It was exploited and enhanced through the addition of a branched amine DPIBA to the usual coreactant TPrA solution for enhancing the ECL efficiency until a maximum of 128%. Finally, a beads-based immunoassay and an immunosensor specific for cardiac Troponin I were built exploiting previous results and carbon nanotubes features. They created a conductive layer around beads enhancing the signal by 70% and activating an ECL mechanism unobserved before in such systems. In conclusion, the combination of ECL microscopy and nanotechnology and the deep understanding of the mechanisms responsible for the ECL emission led to a great enhancement in the signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomarkers are biological indicators of human health conditions. Their ultra-sensitive quantification is of cardinal importance in clinical monitoring and early disease diagnosis. Biosensors are some worldwide simple and easy-to-use analytical devices as a matter of fact, biosensors using electrochemiluminescence (ECL) are one of the most promising biosensors that needs an ever-increasing sensitivity for improving its clinical effectiveness. The principal aspiration of this project is the investigation of the ECL generation mechanisms for enhancing the ECL intensity and the development of an ultrasensitive sensor, the use of metal-oxide materials (Mox) and the substitution of metal-free dyes. Novel dyes such as BODIPY, TADF are used to improve the sensitivity of ECL techniques thanks to their advantageous and tunable properties, enhancing the signal and also the ECL efficiency. Additionally, the use of Mox could be beneficial for the investigation of two different ECL mechanisms, which occur simultaneously. In this thesis, the investigation of size and distance effects on electrochemical (EC) mechanisms was carried out through the innovative combination of a standard detection system using different size of micromagnetic beads (MBs). That allowed the discovery of an unexpected and highly efficient mechanistic path for electrochemical generation at small distances from the electrode’s surface. The smallest MBs (0.1μm) demostrate an enhancement of electrochemical signal than the bigger one (2.8μm) until 4 times of magnitude. Finally, a novel ultrasensitive sensor, based on the coreactant-luminophores mechanism, was developed for the determination of whole viral genome specific for cardiac HBV and COVID-19 virus. In conclusion, the ECL and the use of EC techniques (such as amperometry), improved the understanding of mechanisms responsible for the ECL/EC signal led to a great enhancement in the signal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paper has become increasingly recognized as a very interesting substrate for the construction of microfluidic devices, with potential application in a variety of areas, including health diagnosis, environmental monitoring, immunoassays and food safety. The aim of this review is to present a short history of analytical systems constructed from paper, summarize the main advantages and disadvantages of fabrication techniques, exploit alternative methods of detection such as colorimetric, electrochemical, photoelectrochemical, chemiluminescence and electrochemiluminescence, as well as to take a closer look at the novel achievements in the field of bioanalysis published during the last 2 years. Finally, the future trends for production of such devices are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Constrictive pericarditis (CP) and restrictive cardiomyopathy share many similarities in both their clinical and hemodynamic characteristics and N-terminal prohormone brain natriuretic peptide (NT-proBNP) is a sensitive marker of cardiac diastolic dysfunction. The objectives of the present study were to determine whether serum NT-proBNP was high in patients with endomyocardial fibrosis (EMF) and CP, and to investigate how this relates to diastolic dysfunction. Thirty-three patients were divided into two groups: CP (16 patients) and EMF (17 patients). The control group consisted of 30 healthy individuals. Patients were evaluated by bidimensional echocardiography, with restriction syndrome evaluated by pulsed Doppler of the mitral flow and serum NT-proBNP measured by immunoassay and detected by electrochemiluminescence. Spearman correlation coefficient was used to analyze the association between log NT-proBNP and echocardiographic parameters. Log NT-proBNP was significantly higher (P < 0.05) in CP patients (log mean: 2.67 pg/mL; 95%CI: 2.43-2.92 log pg/mL) and in EMF patients (log mean: 2.91 pg/mL; 95%CI: 2.70-3.12 log pg/mL) compared with the control group (log mean: 1.45; 95%CI: 1.32-1.60 log pg/mL). There were no statistical differences between EMF and CP patients (P = 0.689) in terms of NT-proBNP. The NT-proBNP log tended to correlate with peak velocity of the E wave (r = 0.439; P = 0.060, but not with A wave (r = -0.399; P = 0.112). Serum NT-proBNP concentration can be used as a marker to detect the presence of diastolic dysfunction in patients with restrictive syndrome; however, serum NT-proBNP levels cannot be used to differentiate restrictive cardiomyopathy from CP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two homometallic complexes containing two and three ruthenium polypyridyl units linked by amino acid lysine (Lys) and the related dipeptide (LysLys) were synthesized and their electrochemical, spectroscopic, and electrochemiluminescence (ECL) properties were investigated. The electrochemical and photophysical data indicate that the two metal complexes largely retain the electronic properties of the reference compound for the separate ruthenium moieties in the two bridged complexes, [4-carboxypropyl-4'-methyl-2,2'-bipyridine]bis(2,2'-bipyridine)ruthenium(II) complex. The ECL studies, performed in aqueous media in the presence of tri-n-propylamine as co-reactant, show that the ECL intensity increases by 30% for the dinuclear and trinuclear complexes compared to the reference. Heterogeneous ECL immunoassay studies, performed on larger dendritic complexes containing up to eight ruthenium units, demonstrate that limitations due to the slow diffusion can easily be overcome by means of nanoparticle technology. In this case, the ECL signal is proportional to the number of ruthenium units. Multimetallic systems with several ruthenium centers may, however, undergo nonspecific bonding,to streptavidin-coated particles or to antibodies, thereby increasing the background ECL intensity and lowering the sensitivity of the immunoassay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intense inflammatory response and an anti-angiogenic state have been implicated in the pathogenesis of preeclampsia. Here, we investigated this hypothesis evaluating the serum concentrations of CXCL10/IP-10, sFlt-1, and PlGF in women with early-onset preeclampsia. CXCL10/IP-10 was measured by Cytometric Bead Array. sFlt-1 and PlGF were measured by automated electrochemiluminescence immunoassay. The median serum concentration of CXCL10/IP-10 was 109.5 pg/mL in preeclamptic women, as compared with 52.28 pg/mL in the controls (P = 0.0028). The mean serum level of sFlt-1 was 13,636 pg/mL in preeclamptic women, as compared with 2020 pg/mL in the controls (P < 0.0001). PlGF levels were significantly lower in women with preeclampsia. © 2011 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present PhD project was focused on the development of new tools and methods for luminescence-based techniques. In particular, the ultimate goal was to present substantial improvements to the currently available technologies for both research and diagnostic in the fields of biology, proteomics and genomics. Different aspects and problems were investigated, requiring different strategies and approaches. The whole work was thus divided into separate chapters, each based on the study of one specific aspect of luminescence: Chemiluminescence, Fluorescence and Electrochemiluminescence. CHAPTER 1, Chemiluminescence The work on luminol-enhancer solution lead to a new luminol solution formulation with 1 order of magnitude lower detection limit for HRP. This technology was patented with Cyanagen brand and is now sold worldwide for Western Blot and ELISA applications. CHAPTER 2, Fluorescescence The work on dyed-doped silica nanoparticles is marking a new milestone in the development of nanotechnologies for biological applications. While the project is still in progress, preliminary studies on model structures are leading to very promising results. The improved brightness of these nano-sized objects, their simple synthesis and handling, their low toxicity will soon turn them, we strongly believe, into a new generation of fluorescent labels for many applications. CHAPTER 3, Electrochemiluminescence The work on electrochemiluminescence produced interesting results that can potentially turn into great improvements from an analytical point of view. Ru(bpy)3 derivatives were employed both for on-chip microarray (Chapter 3.1) and for microscopic imaging applications (Chapter 3.2). The development of these new techniques is still under investigation, but the obtained results confirm the possibility to achieve the final goal. Furthermore the development of new ECL-active species (Chapter 3.3, 3.4, 3.5) and their use in these applications can significantly improve overall performances, thus helping to spread ECL as powerful analytical tool for routinary techniques. To conclude, the results obtained are of strong value to largely increase the sensitivity of luminescence techniques, thus fulfilling the expectation we had at the beginning of this research work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cross sectional study investigated the association of tobacco smoke, vitamin D status, anthropometric parameters, and kidney function in Turkish immigrants with type 2 diabetes (T2D) living in the Netherlands. Study sample included a total of 110 participants aged 30 years and older (males= 46; females= 64). Serum cotinine, a biomarker for smoke exposure, was measured with a solid-phase competitive chemiluminescent immunoassay. Serum 25-hydroxyvitamin D [25(OH)D] was determined by electrochemiluminescence immunoassay (ECLIA). Measures of obesity including: body weight, body mass index (BMI), waist circumference (WC), and hip circumference (HC) were measured. Waist-to-hip ratio (WHR) and waist-to-height ratio (WHtR) were calculated. Urine albumin was measured by immunoturbidimetric assay. Urine creatinine was determined using the Jaffe method. All statistical analyses were performed using SPSS, version 19.0 (SPSS Inc., Chicago, IL, USA). Independent samples t-test, chi-squared tests, multiple linear regression and logistic regression analysis were used. Cotinine levels were positively associated with cholesterol to HDL ratio and atherosclerosis-index. Serum 25(OH)D levels were negatively associated with diastolic blood pressure. Gender-specific associations between anthropometric measures and high sensitivity C-reactive protein (hs-CRP) levels were observed. Hs-CRP was positively associated with WC and WHR in males and WHtR in females. Microalbuminuria (MAU), as determined by albumin-to-creatinine ratio, was present in 21% of the Turkish immigrants with T2D. Participants with hypertension were 6.58 times more likely (adjusted odds ratio) to have positive MAU as compared to normotensive participants. Our findings indicate that serum cotinine, 25(OH)D, hs-CRP, and MAU may be assessed as a standard of care for T2D management in the Turkish immigrant population. Further research should be conducted following cohorts to determine the effects of these biomarkers on CVD morbidity and mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Noise is constant presence in measurements. Its origin is related to the microscopic properties of matter. Since the seminal work of Brown in 1828, the study of stochastic processes has gained an increasing interest with the development of new mathematical and analytical tools. In the last decades, the central role that noise plays in chemical and physiological processes has become recognized. The dual role of noise as nuisance/resource pushes towards the development of new decomposition techniques that divide a signal into its deterministic and stochastic components. In this thesis I show how methods based on Singular Spectrum Analysis have the right properties to fulfil the previously mentioned requirement. During my work I applied SSA to different signals of interest in chemistry: I developed a novel iterative procedure for the denoising of powder X-ray diffractograms; I “denoised” bi-dimensional images from experiments of electrochemiluminescence imaging of micro-beads obtaining new insight on ECL mechanism. I also used Principal Component Analysis to investigate the relationship between brain electrophysiological signals and voice emission.