993 resultados para ED Primer II


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. Materials and Methods: The null hypothesis is that the fatigue resistance varies with the luting strategy. Forty blocks of In-Ceram Alumina were prepared, and one surface of each block was abraded with 110-μm aluminum oxide particles. Then, the blocks were luted to flat dentin surfaces of 40 human third molars, using 4 different luting strategies (luting system [LS]/ceramic surface conditioning [CSC]) (n=10): (G1) [LS] RelyX-Unicem/[CSC] airborne abrasion with 110-μm Al2O3 particles; (G2) [LS] One-Step + Duo-Link (bis-GMA-based resin)/[CSC] etching with 4% hydrofluoric acid + silane agent; (G3) [LS] ED-Primer + Panavia F (MDP-based resin)/[CSC] Al2O 3; (G4) [LS] Scotchbond1+RelyX-ARC (bis-GMA-based resin)/[CSC] chairside tribochemical silica coating (air abrasion with 30-μm SiO x particles + silane). After 24 h of water storage at 37°C, the specimens were subjected to 106 fatigue cycles in shear with a sinusoidal load (0 to 21 N, 8 Hz frequency, 37°C water). A fatigue survivor score was given, considering the number of the fatigue cycles until fracture. The failure modes of failed specimens were observed in a SEM. Results: G3 (score = 5.9, 1 failure) and G4 (score = 6, no failures) were statistically similar (p = 0.33) and had significantly higher fatigue resistance than G1 (score = 3.9, 5 failures) and G2 (score = 3.7, 6 failures) (p < 0.03). SEM analysis of fractured specimens of G1 and G2 showed that almost all the failures were between ceramic and cement. Conclusion: The MDP-based resin cement + sandblasting with Al2O3 particles (G3) and bis-GMA-based resin cement + tribochemical silica coating (G4), both using the respective dentin bonding systems, were the best luting protocols for the alumina ceramic. The null hypothesis was confirmed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the bond strength to dentin of two recent resin-ceramic materials for computer-aided design/computer-aided manufacturing (CAD/CAM) after 24 hours and after six months storage. Methods and Materials: Ninety cylinders were milled out of Lava Ultimate (3M ESPE) and 90 cylinders out of VITA ENAMIC (VITA Zahnfabrik) (dimension of cylinders: ∅=3.6 mm, h=2 mm). All Lava Ultimate cylinders were sandblasted (aluminium oxide, grain size: 27 μm) and cleaned with ethanol, whereas all VITA ENAMIC cylinders were acid-etched (5% hydrofluoric acid) and cleaned with water-spray. According to the three groups of cements used, the cylinders (n=30/resin-ceramic material) were further pretreated with 1) Scotchbond Universal for RelyX Ultimate (3M ESPE), 2) CLEARFIL Ceramic Primer for PANAVIA F2.0 (Kuraray), or 3) no further pretreatment for Ketac Cem Plus (3M ESPE). The cylinders were then bonded to ground human dentin specimens with 1) Scotchbond Universal and RelyX Ultimate (light-cured), 2) ED PRIMER II and PANAVIA F2.0 (light-cured), or 3) no adhesive system; Ketac Cem Plus (self-cured). Shear bond strength (SBS) was measured after 24 hours for 15 specimens/group and after six months (37°C, 100% humidity) for the other 15 specimens/group. SBS-values were statistically analysed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests (α=0.05). Results: SBS of the two resin-ceramic materials and the three cements after 24 hours and after six months storage are shown in Figure 1. The statistical analysis showed that the duration of storage had a significant effect on SBS of Lava Ultimate for all three cements but had no significant effect on SBS of VITA ENAMIC. For Lava Ultimate SBS-values were (MPa; medians after 24 hours/six months): 13.5/22.5 (p=0.04) for RelyX Ultimate, 11.4/5.8 (p=0.0006) for PANAVIA F2.0, and 0.34/0.09 (p=0.04) for Ketac Cem Plus (Fig. 1). For VITA ENAMIC SBS-values were (MPa; medians after 24 hours/six months): 16.0/21.2 (p=0.10) for RelyX Ultimate, 11.4/14.4 (p=0.06) for PANAVIA F2.0, and 0.43/0.41 (p=0.32) for Ketac Cem Plus (Fig. 1). After 24 hours, there was no significant difference in SBS between Lava Ultimate and VITA ENAMIC for all three cements (p≥0.37). After six months, there was no significant difference in SBS between Lava Ultimate and VITA ENAMIC for RelyX Ultimate and Ketac Cem Plus (p≥0.07) whereas for PANAVIA F2.0, SBS was significantly lower for Lava Ultimate than for VITA ENAMIC (p<0.0001). Conclusion: SBS of Lava Ultimate was more affected by six months storage and by the cement used than was VITA ENAMIC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research presents Ludwig II of Baviera (1845-1886) as a historical figure and the vision of his reign theItalian director Luchino Visconti showed in his movies. This research states in an analytic and scrupulousway the relations between the historical figure, its filmic representation and the director himself. In addition,through an exhaustive research, this paper shows the aesthetics generated by directors like Visconti who reacheda remarkable peak in history of European film. Finally, this paper goes through the making of this film,which went from a transitional film within the Visconti oeuvre to one of his most troublesome and health-riskingprojects causing afterwards Visconti´s death.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Este libro es una guía para que los estudiantes del programa de Medicina, y de otros campos de las ciencias, se acerquen adecuadamente a un tema tan importante pero complejo como lo es el metabolismo celular. De acuerdo a la metodología de aprendizaje activo que maneja la Unidad de Bioquímica de la Universidad del Rosario, se continúa enunciando premisas que contienen los conceptos a estudiar y ofreciendo una serie de preguntas que el estudiante debe tomar como guía para buscar con autonomía y responsabilidad la información pertinente que le permita comprender esos conceptos. En esta segunda edición, y dentro del ordenamiento lógico de los temas que le permite al estudiante ir ubicando correctamente los procesos metabólicos en el contexto celular, se introducen las “complementaciones” o prácticas experimentales. Estas prácticas están diseñadas para que el estudiante complemente, como su nombre lo indica, los conceptos teóricos en estudio; para lograrlo se ha tenido especial cuidado en evitar la introducción de prácticas clínicas aisladas que, sin dejar de ser importantes, pertenecen a otro contexto y que aquí sólo nos alejarían del verdadero objetivo específico que debe cumplir en este caso una sesión experimental de observación y análisis para verificar teorías. Como un aporte significativo del grupo docente y de los estudiantes en formación como docentes jóvenes, se introducen también los afianzamientos tutoriales o sesiones de encuentro extra clase entre profesores y estudiantes, o entre estudiantes (de niveles superiores con niveles inferiores). En esos encuentros, se presentan una serie de situaciones problémicas, cuyo análisis y solución conjunta constituyen para el estudiante una alternativa para complementar y/o practicar lo aprendido.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

El trasplante de órganos y/o tejidos es considerado como una opción terapéutica viable para el tratamiento tanto de enfermedades crónicas o en estadios terminales, como de afectaciones no vitales, pero que generen una disminución en la calidad de vida percibida por el paciente. Este procedimiento, de carácter multidimensional, está compuesto por 3 actores principales: el donante, el órgano/tejido, y el receptor. Si bien un porcentaje significativo de investigaciones y planes de intervención han girado en torno a la dimensión biológica del trasplante, y a la promoción de la donación; el interés por la experiencia psicosocial y la calidad de vida de los receptores en este proceso ha aumentado durante la última década. En relación con esto, la presente monografía se plantea como objetivo general la exploración de la experiencia y los significados construidos por los pacientes trasplantados, a través de una revisión sistemática de la literatura sobre esta temática. Para ello, se plantearon unos objetivos específicos derivados del general, se seleccionaron términos o palabras claves por cada uno de estos, y se realizó una búsqueda en 5 bases de datos para revistas indexadas: Ebsco Host (Academic Search; y Psychology and Behavioral Sciences Collection); Proquest; Pubmed; y Science Direct. A partir de los resultados, se establece que si bien la vivencia de los receptores ha comenzado a ser investigada, aún es necesaria una mayor exploración sobre la experiencia de estos pacientes; exploración que carecería de objetivo si no se hiciera a través de las narrativas o testimonios de los mismos receptores

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Chromatographic and electroanalytical methods were developed to detect and quantify Sudan II (SD-II) dye in fuel ethanol samples. Sudan II is reduced at +0.50 V vs. Ag/AgCl on a glassy carbon electrode using Britton-Robinson buffer (pH 4.0) and N,N-dimethylformamide (70:30, v/v) + sodium dioctyl sulfosuccinate surfactant as supporting electrolyte, due to the azo group. This is the basis for its determination by square-wave voltammetry (SWV). Using the optimized conditions, it is possible to get a linear calibration curve from 3.00×10-6 to 1.80×10-5 mol L-1 (r = 0.998) with limits of detection (LOD) and quantification (LOQ) of 2.05×10-6 and 6.76×10-6 mol L-1, respectively. In addition, the hydroxyl substituent in the SD-II dye is also oxidized at +0.85 V vs. Ag/AgCl, which was conveniently used for its determination by high-performance liquid chromatography coupled to electrochemical detection (HPLC-ED). Under the optimized condition, the SD-II dye was eluted and separated using a reversed-phase column (cyanopropyl, CN) using isocratic elution with the mobile phase containing acetonitrile and aqueous lithium chloride (5.00×10-4 mol L-1) at 70:30 (v/v) and a flow rate of 1.2 mL min-1. Linear calibration curves were obtained from 3.00×10-7 to 2.00×10-6 mol L-1 (r = 0.999) with LOD and LOQ of 3.10×10-8 and 1.05×10-7 mol L-1, respectively. Both methods were simple, fast and suitable to detect and quantify the dye in fuel ethanol samples at recovery values between 83.0 to 102% (SWV) and 88.0 to 112% (HPLC-ED) with satisfactory precision and accuracy.

Relevância:

90.00% 90.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Statement of problem. There are no established clinical procedures for bonding zirconia to tooth structure using resin cements. Purpose. The purpose of this study was to evaluate the influence of metal primers, resin cements, and aging on bonding to zirconia. Material and methods. Zirconia was treated with commercial primers developed for bonding to metal alloys (Metaltite, Metal Primer II, Alloy Primer or Totalbond). Non-primed specimens were considered as controls. One-hundred disk-shaped specimens (19 x 4 mm) were cemented to composite resin substrates using Panavia or RelyX Unicem (n=5). Microtensile bond strength specimens were tested after 48 hours and 5 months (150 days), and failure modes were classified as type 1 (between ceramic/cement), 2 (between composite resin/cement) or 3 (mixed). Data were analyzed by 3-way ANOVA and Multiple Comparison Tukey test (alpha=.05). Results. The interactions primer/luting system (P=.016) and luting system/storage time (P=.004) were statistically significant. The use of Alloy Primer significantly improved the bond strength of RelyX Unicem (P<.001), while for Panavia, none of the primers increased the bond strength compared to the control group. At 48 hours, Panavia had statistically higher bond strength (P=.004) than Unicem (13.9 +/- 4.4MPa and 10.2 +/- 6.6MPa, respectively). However, both luting systems presented decreasing, statistically similar; values after aging (Panavia: 3.6 +/- 2.2MPa; Unicem: 6.1 +/- 5.3MPa). At 48 hours, Alloy Primer/Unicem had the lowest incidence of type 1 failure (8%). After aging, all the groups showed a predominance of type 1 failures. Conclusions. The use of Alloy Primer improved bond strength between RelyX Unicem and zirconia. Though the initial values obtained with Panavia were significantly higher than RelyX Unicem, after aging, both luting agents presented statistically similar performances. (J Prosthet Dent 2011;105:296-303)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Des modèles de dysfonction érectile (DE) ont été développés et étudiés chez le rat. Cependant, peu de choses sont connues dans certains modèles présentant des facteurs de risque de la DE, en l’occurrence le rat soumis à une diète riche en glucose, le rat avec une restriction de croissance intra-utérine (RCIU) et le rat avec l’infusion continue de l’angiotensine (Ang) II en ce qui concerne l’évaluation de la fonction érectile in vivo. C’est ainsi que nous nous sommes proposés cette étude. La fonction érectile a été mesurée par la stimulation électrique du nerf caverneux à des cohortes de rats mâles Sprague-Dawley de différents âges comme suit: 1) des rats jeunes de 12 semaines d’âge, adultes reproducteurs à la retraite d’environ 30 semaines d’âge et des rats de 27 et 29 semaines soumis à une diète riche en glucose par l’eau de breuvage (10%) à court (1 semaine), moyen (6 semaines) et long (12 ou 13 semaines) termes; 2) des rats jeunes âgés de 12 semaines recevant une infusion soit de l’Ang II (200ng/kg/min) soit de la saline par mini-pompes osmotiques sous-cutanées pendant 1 et 2 semaines; et 3) des rats adultes âgés de 36 semaines avec une RCIU. La fonction érectile a été représentée par des courbes de variations de pression intracaverneuse (PIC) et d’aire sous la courbe (ASC) normalisées avec la pression artérielle moyenne (PAM) en réponse à la stimulation nerveuse à différents volts. À la fin des expériences, les animaux ont été sacrifiés, le sang recueilli pour le dosage de la glycémie et de l’insulinémie; le pénis, l’aorte thoracique et le cœur prélevés à des fins d’analyses protéique et histologique. La diète riche en glucose à court terme a eu un effet néfaste sur la fonction érectile chez le jeune rat mais bénéfique chez le rat adulte reproducteur; de même que pour les études à long terme, la diète riche en glucose a amélioré ou renversé la DE associée au vieillissement. Les rats avec RCIU ont exhibé une baisse très significative de la fonction érectile. Ces détériorations ou améliorations de la fonction érectile avec le glucose ou dans la RCIU ont été principalement associées à des modifications de l’expression de l’Akt, en plus d’une augmentation de l’insuline sérique dans les groupes avec le glucose. L’Ang II a entraîné une baisse de la fonction érectile, statistiquement très significative après 1 semaine et maintenue après 2 semaines de traitement, sans causer des changements morphologiques au cœur et à l’aorte thoracique. En conclusion : l’atteinte du système érectile se fait précocement dans les complications cardiovasculaires liées à l’activation du SRA, l’implication de l’Akt dans la modulation de la fonction érectile dépend de type de vieillissement et de la diète, le RCIU est un facteur de risque pour la DE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Es un estudio de derecho comparado sobre el principio de autonomía territorial en Bolivia y Colombia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La utilización del modelo de regresión lineal en los procesos relacionados con el análisis de datos demanda el conocimiento objetivo e instrumentación de la relación funcional de variables, el coeficiente de determinación y de correlación y la prueba de hipótesis como pilares fundamentales para verificar e interpretar su significancia estadística en el intervalo de confianza determinado. La presentación específica de los temas relacionados con el modelo de regresión lineal, el análisis de regresión, el uso de la ecuación de regresión como instrumento para estimar y predecir y la consideración del análisis de residuales ha sido realizada tomando como referente el estudio de problemas reales definidos en los entornos de la economía, la administración y la salud, utilizando como plataforma de apoyo la hoja de cálculo Excel®. Se consideran en este módulo didáctico, los elementos teóricos correspondientes al análisis de regresión lineal, como técnica estadística empleada para estudiar la relación entre variables determinísticas o aleatorias que resultan de algún tipo de investigación, en la cual se analiza el comportamiento de dos variables, una dependiente y otra independiente. Se muestra mediante la gráfica de dispersión el posible comportamiento de las variables: lineal directa, inversa, no lineal directa o no lineal inversa, con el fin de desarrollar en el lector las competencias interpretativas y propositivas requeridas para dimensionar integralmente la importancia de la estadística inferencial en la vida del profesional en ciencias económicas, administrativas y de la salud.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La utilización del modelo de regresión lineal en los procesos relacionados con el análisis de datos demanda el conocimiento objetivo e instrumentación de la relación funcional de variables, el coeficiente de determinación y de correlación y la prueba de hipótesis como pilares fundamentales para verificar e interpretar su significancia estadística en el intervalo de confianza determinado. La presentación específica de los temas relacionados con el modelo de regresión lineal, el análisis de regresión, el uso de la ecuación de regresión como instrumento para estimar y predecir y la consideración del análisis de residuales ha sido realizada tomando como referente el estudio de problemas reales definidos en los entornos de la economía, la administración y la salud, utilizando como plataforma de apoyo la hoja de cálculo Excel®.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Los precios de transferencia ocupan el interés de los Estados en el mundo actual al constituir uno de los retos fundamentales del Derecho Internacional Tributario. En el seno de la Organización para la Cooperación y el Desarrollo Económicos (OCDE), creada en 1961, se discutieron y desarrollaron diversas propuestas para regular el fenómeno. Estas, se materializaron en Modelos de Convenios Tributarios e instrumentos de soft law, que hoy en día constituyen los principios internacionalmente aceptados en la materia. Las Guías de la OCDE sobre precios de transferencia para empresas multinacionales y administraciones tributarias son el cuerpo normativo de soft law que se erigen, en el Ordenamiento Internacional, como el norte de las legislaciones a nivel interno para efectos de regulación de dicha temática. Su adopción por parte de los países miembros y no miembros de la OCDE se enfrenta a problemas teóricos derivados del quebrantamiento del decantado principio de reserva de ley tributaria y el respeto por la seguridad jurídica, razón por la cual su incorporación ha variado de Estado a Estado. El presente trabajo recoge la experiencia en varios países europeos y latinoamericanos y pretende proponer una fórmula de adopción en Colombia, coherente con los principios constitucionales tributarios y con virtualidad de superar las críticas realizadas por la doctrina a la aplicación directa de las Guías.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose:This study evaluated the microtensile bond strength of two resin cements to dentin either with their corresponding self-etching adhesives or employing the three-step etch-and-rinse technique. The null hypothesis was that the etch-and-rinse adhesive system would generate higher bond strengths than the self-etching adhesives.Materials and Methods:Thirty-two human molars were randomly divided into four groups (N = 32, n = 8/per group): G1) ED Primer self-etching adhesive + Panavia F; G2) All-Bond 2 etch-and-rinse adhesive + Panavia F; G3) Multilink primer A/B self-etching adhesive + Multilink resin cement; G4) All-Bond 2 + Multilink. After cementation of composite resin blocks (5 x 5 x 4 mm), the specimens were stored in water (37 degrees C, 24 hours), and sectioned to obtain beams (+/- 1 mm2 of adhesive area) to be submitted to microtensile test. The data were analyzed using 2-way analysis of variance and Tukey's test (alpha = 0.05).Results:Although the cement type did not significantly affect the results (p = 0.35), a significant effect of the adhesive system (p = 0.0001) was found on the bond strength results. Interaction terms were not significant (p = 0.88751). The etch-and-rinse adhesive provided significantly higher bond strength values (MPa) with both resin cements (G2: 34.4 +/- 10.6; G4: 33.0 +/- 8.9) compared to the self-etching adhesive systems (G1: 19.8 +/- 6.6; G3: 17.8 +/- 7.2) (p < 0.0001). Pretest failures were more frequent in the groups where self-etching systems were used.Conclusion:Although the cement type did not affect the results, there was a significant effect of changing the bonding strategy. The use of the three-step etch-and-rinse adhesive resulted in significantly higher bond strength for both resin cements on dentin.CLINICAL SIGNIFICANCEDual polymerized resin cements tested could deliver higher bond strength to dentin in combination with etch-and-rinse adhesive systems as opposed to their use in combination with self-etching adhesives.(J Esthet Restor Dent 22:262-269, 2010).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)