999 resultados para Distance protection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the development and implementation of an artificial neural network based algorithm for transmission lines distance protection. This algorithm was developed to be used in any transmission line regardless of its configuration or voltage level. The described ANN-based algorithm does not need any topology adaptation or ANN parameters adjustment when applied to different electrical systems. This feature makes this solution unique since all ANN-based solutions presented until now were developed for particular transmission lines, which means that those solutions cannot be implemented in commercial relays. (c) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an interactive simulation environment for distance protection, developed with ATP and foreign models based on ANSI C. Files in COMTRADE format are possible to generate after ATP simulation. These files can be used to calibrate real relays. Also, the performance of relay algorithms with real oscillography events is possible to assess by using the ATP option for POSTPROCESS PLOT FILE (PPF). The main purpose of the work is to develop a tool to allow the analysis of diverse fault cases and to perform coordination studies, as well as, to allow the analysis of the relay's performance in the face of a real event. © 2011 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This letter presents an extension of an existing ground distance relay algorithm to include phase distance relays. The algorithm uses a fault resistance estimation process in the phase domain, improving efficiency in the distance protection process. The results show that the algorithm is suitable for online applications, and that it has an independent performance from the fault resistance magnitude, the fault location, and the line asymmetry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O tema do sistema de automação da protecção diferencial de linha e comparação direccional é merecedor de uma nova abordagem devido às recentes inovações tecnológicas ocorridas desde o aparecimento dos relés digitais e à consequente comunicação entre os sistemas de protecção, em particular na comunicação entre protecções diferenciais de linha. A protecção diferencial de linha apresenta claras vantagens face às protecções actualmente utilizadas para a protecção de linhas de transmissão e distribuição, tais como, Protecção de Máximo Intensidade de Fase, Máximo Intensidade Homopolar Direccionale Protecção de Distância. Contudo, existem alguns problemas associados a este tipo de protecções, nomeadamente na comunicação entre relés. Para automação e comunicação de protecções diferenciais de linhas de transmissão, no caso da ocorrência de defeitos na zona protegida pelo sistema de protecção diferencial foi empregue um método inovador para este tipo de sistema. Uma vez que a eficácia da actuação das protecções diferenciais depende do rigor das variáveis que são necessárias enviar entre protecções que se encontram localizadas em subestações distintas, recorreu-se à utilização de um automatismo para comunicação entre relés suportado pelo desenvolvimento de novos algoritmos para detectar quase instantaneamente um defeito em qualquer zona de protecção de uma linha de transmissão. Estes algoritmos são baseados na Transformada de Park, pelo que, é introduzido um novo conceito neste tipo de protecções. Através destes algoritmos é possível atenuar os problemas associados à protecção diferencial de linha. No sentido de verificar a aplicabilidade destes algoritmos à protecção diferencial de linha são apresentados diversos casos de estudo. Através dos resultados obtidos também foi possível verificar as vantagens associadas à utilização dos algoritmos propostos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work proposes a new technique for phasor estimation applied in microprocessor numerical relays for distance protection of transmission lines, based on the recursive least squares method and called least squares modified random walking. The phasor estimation methods have compromised their performance, mainly due to the DC exponential decaying component present in fault currents. In order to reduce the influence of the DC component, a Morphological Filter (FM) was added to the method of least squares and previously applied to the process of phasor estimation. The presented method is implemented in MATLABr and its performance is compared to one-cycle Fourier technique and conventional phasor estimation, which was also based on least squares algorithm. The methods based on least squares technique used for comparison with the proposed method were: forgetting factor recursive, covariance resetting and random walking. The techniques performance analysis were carried out by means of signals synthetic and signals provided of simulations on the Alternative Transient Program (ATP). When compared to other phasor estimation methods, the proposed method showed satisfactory results, when it comes to the estimation speed, the steady state oscillation and the overshoot. Then, the presented method performance was analyzed by means of variations in the fault parameters (resistance, distance, angle of incidence and type of fault). Through this study, the results did not showed significant variations in method performance. Besides, the apparent impedance trajectory and estimated distance of the fault were analysed, and the presented method showed better results in comparison to one-cycle Fourier algorithm

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The location of ground faults in railway electric lines in 2 × 5 kV railway power supply systems is a difficult task. In both 1 × 25 kV and transmission power systems it is common practice to use distance protection relays to clear ground faults and localize their positions. However, in the particular case of this 2 × 25 kV system, due to the widespread use of autotransformers, the relation between the distance and the impedance seen by the distance protection relays is not linear and therefore the location is not accurate enough. This paper presents a simple and economical method to identify the subsection between autotransformers and the conductor (catenary or feeder) where the ground fault is happening. This method is based on the comparison of the angle between the current and the voltage of the positive terminal in each autotransformer. Consequently, after the identification of the subsection and the conductor with the ground defect, only the subsection where the ground fault is present will be quickly removed from service, with the minimum effect on rail traffic. This method has been validated through computer simulations and laboratory tests with positive results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. Chrysophtharta bimaculata is a native chrysomelid species that can cause chronic defoliation of plantation and regrowth Eucalyptus forests in Tasmania, Australia. Knowledge of the dispersion pattern of C. bimaculata was needed in order to assess the efficiency of an integrated pest management (IPM) programme currently used for its control. 2. Using data from yellow flight traps, local populations of C. bimaculata adults were monitored over a season at spatial scales relevant to commercial forestry: within a 50-ha operational management unit (a forestry 'coupe') and between coupes. In addition, oviposition was monitored over a season at a subset of the between-coupe sites. 3. Dispersion indices (Taylor's Power Law and Iwao's Mean Crowding regression method) demonstrated that C. bimaculata adults were spatially aggregated within and between coupes, although the number of egg-batches laid at the between-coupe scale was uniform. Spatial autocorrelation analysis showed that trap-catches at the within-coupe level were similar (positively autocorrelated) to a radius distance of approximately 110 m, and then dissimilar (negatively autocorrelated) at approximately 250 m. At the between-coupe scale, no repeatable spatial autocorrelation patterns were observed. 4. For any individual site, rapid changes in beetle density were observed to be associated with loosely aggregated flights of beetles into and out of that site. Peak adult catches (> the weekly mean plus standard deviation trap-catch) for a site occurred for a period of 2.0 +/- 0.22 weeks at a time (n = 37), with normally only one or two peaks per site per season. Peak oviposition events for a site occurred on average 1.4 +/- 0.11 times per season and lasted 1.5 +/- 0.12 weeks. 5. Analysis of an extensive data set (n = 417) demonstrated that adult abundance at a site was positively correlated with egg density, but negatively correlated with tree damage (caused by conspecifics) and the presence of conspecific larvae. There was no relationship between adult abundance and a visual estimate of the amount of young foliage on trees. 6. Adults of C. bimaculata are show n to occur in relatively small, mobile aggregations. This means that pest surveys must be both regular (less than 2 weeks apart) and intensive (with sampling points no more than 150 m apart) if beetle populations are to be monitored with confidence. Further refinement of the current IPM strategy must recognize the problems posed by this temporal and spatial patchiness, particularly with regard to the use of biological insecticides, such as Bacillus thuringiensis, for which only a very short operational window exists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with the protection of wind energy systems against the indirect effects of lightning. As wind energy is gaining increasing importance throughout the world, lightning damages involving wind energy systems have come to be regarded with more attention. Nevertheless, there are still very few studies in Portugal regarding lightning protection of wind energy systems using models of the Electro-Magnetic Transients Program (EMTP). Hence, a new case study is presented in this paper, based on a wind turbine with an interconnecting transformer, considering that lightning strikes the soil near the tower at a distance such that galvanic coupling occurs through the grounding electrode. Computer simulations obtained by using EMTP-RV are presented and conclusions are duly drawn. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Attorney General’s Consumer Protection Division receives hundreds of calls and consumer complaints every year. Follow these tips to avoid unexpected expense and disappointments. This record is about: Hang up on long distance slamming!

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes different possibilities of protection and control system improvement of primary distribution substation. The status of condition and main problems of power networks from reliability point of view in Russia are described. This work studies technologies used today in Russia for protection of distribution networks with their disadvantages. Majority of medium voltage networks (6-35 kV) has isolated network point. There is still no any protection available on the market which allows to estimate distance to fault in case of earth fault. The thesis analyses methods of earth fault distance calculation. On the basis of computer simulation the influence of various factors on calculation accuracy is studied. The practical implementation of the method presupposes usage of digital relay. Application of digital relay is accompanied by numerous opportunities which are described in this work. Also advantages of system implemented on the basis of IEC 61850 standard are examined. Finally, suitability of modern digital relays from GOST standard point of view is analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"Mémoire présenté à la Faculté des études supérieures en vue de l'obtention du grade de LL.M. en droit option droit des technologies de l'information"

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cet article délivre un bref aperçu de la nouvelle législation européenne et allemande relative au commerce électronique et à la protection des consommateurs. Il décrit le développement du commerce électronique, de la législation et de la jurisprudence au cours des dernières années. Une distinction est établie entre les niveaux européen et allemand. La nouvelle Directive sur le commerce électronique a été adoptée le 8 juin 2000 et doit être transposée dans la loi nationale avant le 17 janvier 2002. Elle sera décrite et succinctement analysée avant d’aborder la nouvelle loi allemande portant sur les contrats à distance qui vient d’être adoptée par le Parlement allemand pour transposer la Directive sur les contrats à distance de 1997. Le cadre juridique existant avant l’entrée en vigueur de la nouvelle loi sur les contrats à distance sera également exposée en tenant compte de la protection des consommateurs. Alors que l’Union européenne vient de créer une nouvelle Directive sur le commerce électronique, les États membres sont encore occupés à transformer celle de 1997 en loi nationale. En comparant la législation européenne et allemande, nous soulignerons donc le point faible de la législation européenne : le temps nécessaire pour établir un cadre juridique efficace et fonctionnel peut facilement atteindre plusieurs années. L’article s’achèvera sur une courte présentation du « powershopping » ou « community shopping », en passe de devenir un nouveau modèle pour le consommateur européen, qui a fait l’objet de décisions restrictives ces derniers temps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les glycosides sont reconnus pour leur potentiel pharmaceutique tels que les antibiotiques, les agents anticancéreux et antiviraux. Ils sont impliqués dans plusieurs processus biologiques entre autres la reconnaissance cellulaire, l’inflammation, la réponse immunitaire, la croissance, le transport cellulaire, l’adhésion cellulaire et les groupes sanguin. Notre groupe excelle dans la glycosidation stéréocontrôlée avec un minimum de protection suivant le concept d’activation à distance d’aglycones hétérocycliques anomériques. La présence d’une quantité sous stoechiométrique d’acide de Lewis, les (2-pyridyl)-β-D-glycosides déprotégés sont d’excellents donneurs permettant de haute sélectivité pour l’anomère- α-D de glycosides simples et complexes. Inversement, (2-pyridyl)-α-D-glycosides donnent les β-D-glycosides avec de bonne sélectivité. Des exemples de formation stéréocontrôlée de glycosides sont présentés dans cette thèse avec des accepteurs tels que les phénols, les stéroïdes, les terpènes et les acides hydroxyaminés. Cette méthodologie de glycosidation a été appliquée sur support solide.