995 resultados para Distance inter-canines (Inter-canine distance)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims To investigate the relationship between unilateral PIC and specific dentofacial parameters. Materials and methods A sample of 216 subjects, with 108 subjects in the retrospective and prospective samples respectively. Dental parameters: The following dental parameters were assessed: Inter-canine and intermolar width; palatal depth and palatal area; anterior Bolton tooth-size discrepancy (TSD); maxillary arch shape and ratio and maxillary central and lateral incisor shape and ratio. Facial parameters: Three-dimensional (3D) images were taken for subjects in the prospective sample only, and were used to assess the following facial parameters: Face shape; face ratio and 3D distances and angles. Results Dental parameters: Inter-canine width was significantly smaller in the test group compared to the control group in the retrospective (p= 0.0002) and prospective (p= 0.0018) samples respectively. Anterior Bolton TSD was significantly higher in the prospective test group compared to controls (p= 0.0070). Arch ratio was significantly smaller in the test group than the control group for the retrospective sample (p= 0.0029), whereas no significant difference was recorded in the prospective sample (p= 0.1017). Arch shape distribution was significantly different in the retrospective sample (p= 0.009). Tooth shape distribution was significantly different for the maxillary right central incisor in the retrospective sample (p= 0.030). Tooth ratio showed no significant difference for both samples. Facial parameters: Basal width was significantly smaller in the test compared to the control group (p= 0.0001). No significant difference was found in all other 3D distances and angles measured. Conclusion Inter-canine width was significantly smaller in unilateral PIC subjects compared to controls. Anterior Bolton TSD was significantly higher in prospective unilateral PIC compared to controls. Maxillary arch ratio was significantly smaller in retrospective subjects. Square/tapered tooth shape was significantly more common in the retrospective group. Basal width was significantly smaller in subjects with unilateral PIC than controls.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: avaliar as diferenças produzidas nas dimensões e forma de arco pelos tratamentos com aparelho expansor fixo tipo Hyrax e aparelho expansor removível tipo Placa de Hawley com parafuso expansor palatino centralizado. MATERIAL E MÉTODOS: foram selecionados modelos de estudo iniciais e finais de 31 crianças portadoras de mordida cruzada posterior, de ambos os gêneros, de origem étnica diversa e na fase da dentadura mista, tratadas nos cursos de Graduação e Pós-Graduação em Ortodontia do Departamento de Clínica Infantil da Faculdade de Odontologia de Araraquara - UNESP. Destas crianças, 15 foram tratadas com uso do aparelho expansor fixo tipo Hyrax e as demais 16 crianças foram tratados com expansão rápida da maxila efetuada com o aparelho expansor fixo. Foram realizadas medidas das distâncias intercaninos e intermolares, da inclinação do processo alveolar e inclinação dentária nas imagens escaneadas do arco superior e do contorno do palato, obtido com auxílio de um template ajustável e do programa de análises Radiocef Studio. RESULTADOS E CONCLUSÕES: os resultados indicam uma mudança significante nas distâncias intercaninos e intermolares em ambos os grupos e uma inclinação dentária e do processo alveolar para vestibular significante no grupo tratado com o aparelho expansor fixo. A expansão conseguida pelo aparelho expansor fixo foi aproximadamente o dobro da promovida pelo aparelho expansor removível.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effect of the relationship between particle size (d), inter-particle distance (x(i)), and metal loading (y) of carbon supported fuel cell Pt or PtRu catalysts on their catalytic activity, based on the optimum d (2.5-3 nm) and x(i)/d (>5) values, was evaluated. It was found that for y < 30 wt%, the optimum values of both d and x(i)/d can be always obtained. For y >= 30 wt%, instead, the positive effect of a thinner catalyst layer of the fuel cell electrode than that using catalysts with y < 30 wt% is concomitant to a decrease of the effective catalyst surface area due to an increase of d and/or a decrease of x(i)/d compared to their optimum values, with in turns gives rise to a decrease in the catalytic activity. The effect of the x(i)/d ratio has been successfully verified by experimental results on ethanol oxidation on PtRu/C catalysts with same particle size and same degree of alloying but different metal loading. Tests in direct ethanol fuel cells showed that, compared to 20 wt% PtRu/C, the negative effect of the lower x(i)/d on the catalytic activity of 30 and 40 wt% PtRu/C catalysts was superior to the positive effect of the thinner catalyst layer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Today more than ever, generating and managing knowledge is an essential source of competitive advantage for every organization, and particularly for Multinational corporations (MNC). However, despite the undisputed agreement about the importance of creating and managing knowledge, there are still a large number of corporations that act unethically or illegally. Clearly, there is a lack of attention in gaining more knowledge about the management of ethical knowledge in organizations. This paper refers to value-based knowledge, as the process of recognise and manage those values that stand at the heart of decision-making and action in organizations. In order to support MNCs in implementing value-based knowledge process, the managerial ethical profile (MEP) has been presented as a valuable tool to facilitate knowledge management process at both the intra-organizational network level and at the inter-organizational network level.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The paper provides an assessment of the performance of commercial Real Time Kinematic (RTK) systems over longer than recommended inter-station distances. The experiments were set up to test and analyse solutions from the i-MAX, MAX and VRS systems being operated with three triangle shaped network cells, each having an average inter-station distance of 69km, 118km and 166km. The performance characteristics appraised included initialization success rate, initialization time, RTK position accuracy and availability, ambiguity resolution risk and RTK integrity risk in order to provide a wider perspective of the performance of the testing systems. ----- ----- The results showed that the performances of all network RTK solutions assessed were affected by the increase in the inter-station distances to similar degrees. The MAX solution achieved the highest initialization success rate of 96.6% on average, albeit with a longer initialisation time. Two VRS approaches achieved lower initialization success rate of 80% over the large triangle. In terms of RTK positioning accuracy after successful initialisation, the results indicated a good agreement between the actual error growth in both horizontal and vertical components and the accuracy specified in the RMS and part per million (ppm) values by the manufacturers. ----- ----- Additionally, the VRS approaches performed better than the MAX and i-MAX when being tested under the standard triangle network with a mean inter-station distance of 69km. However as the inter-station distance increases, the network RTK software may fail to generate VRS correction and then may turn to operate in the nearest single-base RTK (or RAW) mode. The position uncertainty reached beyond 2 meters occasionally, showing that the RTK rover software was using an incorrect ambiguity fixed solution to estimate the rover position rather than automatically dropping back to using an ambiguity float solution. Results identified that the risk of incorrectly resolving ambiguities reached 18%, 20%, 13% and 25% for i-MAX, MAX, Leica VRS and Trimble VRS respectively when operating over the large triangle network. Additionally, the Coordinate Quality indicator values given by the Leica GX1230 GG rover receiver tended to be over-optimistic and not functioning well with the identification of incorrectly fixed integer ambiguity solutions. In summary, this independent assessment has identified some problems and failures that can occur in all of the systems tested, especially when being pushed beyond the recommended limits. While such failures are expected, they can offer useful insights into where users should be wary and how manufacturers might improve their products. The results also demonstrate that integrity monitoring of RTK solutions is indeed necessary for precision applications, thus deserving serious attention from researchers and system providers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes an innovative instance similarity based evaluation metric that reduces the search map for clustering to be performed. An aggregate global score is calculated for each instance using the novel idea of Fibonacci series. The use of Fibonacci numbers is able to separate the instances effectively and, in hence, the intra-cluster similarity is increased and the inter-cluster similarity is decreased during clustering. The proposed FIBCLUS algorithm is able to handle datasets with numerical, categorical and a mix of both types of attributes. Results obtained with FIBCLUS are compared with the results of existing algorithms such as k-means, x-means expected maximization and hierarchical algorithms that are widely used to cluster numeric, categorical and mix data types. Empirical analysis shows that FIBCLUS is able to produce better clustering solutions in terms of entropy, purity and F-score in comparison to the above described existing algorithms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In spite of significant research in the development of efficient algorithms for three carrier ambiguity resolution, full performance potential of the additional frequency signals cannot be demonstrated effectively without actual triple frequency data. In addition, all the proposed algorithms showed their difficulties in reliable resolution of the medium-lane and narrow-lane ambiguities in different long-range scenarios. In this contribution, we will investigate the effects of various distance-dependent biases, identifying the tropospheric delay to be the key limitation for long-range three carrier ambiguity resolution. In order to achieve reliable ambiguity resolution in regional networks with the inter-station distances of hundreds of kilometers, a new geometry-free and ionosphere-free model is proposed to fix the integer ambiguities of the medium-lane or narrow-lane observables over just several minutes without distance constraint. Finally, the semi-simulation method is introduced to generate the third frequency signals from dual-frequency GPS data and experimentally demonstrate the research findings of this paper.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose This study evaluated the impact of patient set-up errors on the probability of pulmonary and cardiac complications in the irradiation of left-sided breast cancer. Methods and Materials Using the CMS XiO Version 4.6 (CMS Inc., St Louis, MO) radiotherapy planning system's NTCP algorithm and the Lyman -Kutcher-Burman (LKB) model, we calculated the DVH indices for the ipsilateral lung and heart and the resultant normal tissue complication probabilities (NTCP) for radiation-induced pneumonitis and excess cardiac mortality in 12 left-sided breast cancer patients. Results Isocenter shifts in the posterior direction had the greatest effect on the lung V20, heart V25, mean and maximum doses to the lung and the heart. Dose volume histograms (DVH) results show that the ipsilateral lung V20 tolerance was exceeded in 58% of the patients after 1cm posterior shifts. Similarly, the heart V25 tolerance was exceeded after 1cm antero-posterior and left-right isocentric shifts in 70% of the patients. The baseline NTCPs for radiation-induced pneumonitis ranged from 0.73% - 3.4% with a mean value of 1.7%. The maximum reported NTCP for radiation-induced pneumonitis was 5.8% (mean 2.6%) after 1cm posterior isocentric shift. The NTCP for excess cardiac mortality were 0 % in 100% of the patients (n=12) before and after setup error simulations. Conclusions Set-up errors in left sided breast cancer patients have a statistically significant impact on the Lung NTCPs and DVH indices. However, with a central lung distance of 3cm or less (CLD <3cm), and a maximum heart distance of 1.5cm or less (MHD<1.5cm), the treatment plans could tolerate set-up errors of up to 1cm without any change in the NTCP to the heart.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper details a workshop aimed at exploring opportunities for experience design through wearable art and design concepts. Specifically it explores the structure of the workshop with respect to facilitating learning through technology in the development of experiential wearable art and design. A case study titled Cloud Workshop: Wearables and Wellbeing; Enriching connections between citizens in the Asia-Pacific region was initiated through a cooperative partnership between Hong Kong Baptist University (HKBU), Queensland University of Technology (QUT) and Griffith University (GU). Digital technologies facilitated collaboration through an inter-disciplinary, inter-national and inter- cultural approach (Facer & Sandford, 2010) between Australia and Hong Kong. Students cooperated throughout a two-week period to develop innovative wearable concepts blending art, design and technology. An unpacking of the approach, pedagogical underpinning and final outcomes revealed distinct educational benefits as well as certain learning and technological challenges of the program. Qualitative feedback uncovered additional successes with respect to student engagement and enthusiasm, while uncovering shortcomings in the delivery and management of information and difficulties with cultural interactions. Potential future versions of the program aim to take advantage of the positives and overcome the limitations of the current pedagogical approach. It is hoped the case study will become a catalyst for future workshops that blur the boundaries of art, design and technology to uncover further benefits and potentials for new outcomes in experience design.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Artemia is a small crustacean that adapted to live in brine water and has been seen in different brine water sources in Iran. Considering the importance of genetic studies manifest inter population differences in species, to estimate genetic structure, detect difference at molecular level and separate different Artemia populations of Iran, also study of phylogenic relationships among them, samples of Artemia were collected from nine region: Urmia lake in West Azerbaijan, Shoor and Inche-Borun lakes in Golestan, Hoze-Soltan and Namak lakes in Qom, Maharloo and Bakhteghan lakes in Fars, Nough pool in Kerman and Mighan pool in Markazi and DNA extracted by phenol-chloroform method. Primers designed on a ribosomal fragment (16s rRNA) of mt DNA sequence and PCR was done. Digestion of the 1566 bp segment PCR product by 10 restriction endonuclease (Alu I, EcoR I, Eco47 I, Hae III, Hind III, Hinf I, Mbo I, Msp I, Rsa I, TaqI) showed 25 different haplotypes: 9 in Urmia, 4 in Shoor and Inche- Borun, 1 in Namak and Hoze-Soltan, 3 in Mighan, 1 in Bakhtegan Maharlo, 3 in Maharloo and 4 in Nough. Measurement of haplotype and nucleotide diversity intra population and nucleotide diversity and divergence inter populations and evolutionary distance between haplotypes showed a high diversity in mitochondrial genome of Artemia in studied regions whose results are similar to those explained for highly geographic expansion organism. In addition, results showed considerable heterogeneity between different populations and there are enough evidences in haplotypic level for separation of studied samples and division of Iranian Artemia to seven populations including Urmia, Shoor and Inche-Borun, Hoze-Soltan and Namak, Maharloo, Bakhteghan, Nough and Mighan. Phylogenetic analysis of the 16S rRNA data set resulted strict consensus and neighbor joining distance trees, demonstrated that all samples were monophyletic and parthenogenetic form derivation from bisexual populations and genetically high resemblance to those of A. urmiana. Study of 270 specimens from different region showed the genus Artemia in Iran clustered into three clades including: 1- Shoor, Inche-Burun, Hoze-Soltan, Namak, Bakhtegan and Maharloo 2- Nough and Mighan 3- Urmia. Totally, obtained results indicated to ability of used techniques for study of inter species diversity, population structure, reveal of phylogenic relationship and dividing of different populations of Artemia in Iran.