999 resultados para Direct violet 51


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Microbiologia Aplicada) - IBRC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present work was to observe microbial decolorization and biodegradation of the Direct Violet 51 azo dye by Candida albicans isolated from industrial effluents and study the metabolites formed after degradation. C. albicans was used in the removal of the dye in order to further biosorption and biodegradation at different pH values in aqueous solutions. A comparative study of biodegradation analysis was carried out using UV-vis and FTIR spectroscopy, which revealed significant changes in peak positions when compared to the dye spectrum. Theses changes in dye structure appeared after 72 h at pH 2.50; after 240 h at pH 4.50; and after 280 h at pH 6.50, indicating the different by-products formed during the biodegradation process. Hence, the yeast C. albicans was able to remove the color substance, demonstrating a potential enzymatic capacity to modify the chemical structure of pigments found in industrial effluents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o grande crescimento da população e consequentemente o aumento significativo do consumo de produtos de origem industrial, quantidades enormes de efluentes são geradas, e muitas vezes descartadas de forma imprópria. Esses resíduos industriais comumente são eliminados em mananciais hídricos, afetando lençóis freáticos, córregos, rios e oceanos. Uma das maiores evidências da poluição da água é a alteração de sua cor original. Despejo de efluentes têxteis, por exemplo, alem de alterar drasticamente a cor dos mananciais, geram produtos e subprodutos tóxicos, nocivos tanto para a flora como para a fauna aquática. Essas substâncias possuem alta persistência em meio aquático devido a sua natureza química, conferindo a estes efluentes um lento processo de biodegradação e podendo ter efeito bioacumulativo na cadeia alimentar. Assim veem sendo desenvolvidas diversas maneiras de se controlar a quantidade e a qualidade de efluentes industriais, dentre eles os de corantes têxteis. As técnicas mais utilizadas são a cloração, filtração, tratamentos floculantes e adsorção por Carvão Ativados. Porem, muitas vezes esses processos possuem desvantagens, como, por exemplo, o alto custo e alterações drásticas no pH. Assim tratamentos alternativos, como o uso de Moringa oleifera, veem sendo muito estudados. Este trabalho visou avaliar o potencial do uso das sementes de Moringa oleifera como adsorvente na remoção de corantes têxteis em meio aquoso. Para isso foi analisado a remoção do corante Direct Violet 51, utilizando pó das sementes. Foram realizados testes com diferentes tempos de contato nos valores de pH 2,5, 4,5 e 6,5. Posteriormente novos testes foram realizados, utilizando o sobrenadante e a biomassa das sementes, ambos na forma livre e imobilizada em alginato de calcio, bem como reutilização destes. Através da analise das amostras, notou-se que o processo de coagulação/floculação sobressaiu-se em...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o grande crescimento da população e consequentemente o aumento significativo do consumo de produtos de origem industrial, quantidades enormes de efluentes são geradas, e muitas vezes descartadas de forma imprópria. Esses resíduos industriais comumente são eliminados em mananciais hídricos, afetando lençóis freáticos, córregos, rios e oceanos. Uma das maiores evidências da poluição da água é a alteração de sua cor original. Despejo de efluentes têxteis, por exemplo, alem de alterar drasticamente a cor dos mananciais, geram produtos e subprodutos tóxicos, nocivos tanto para a flora como para a fauna aquática. Essas substâncias possuem alta persistência em meio aquático devido a sua natureza química, conferindo a estes efluentes um lento processo de biodegradação e podendo ter efeito bioacumulativo na cadeia alimentar. Assim veem sendo desenvolvidas diversas maneiras de se controlar a quantidade e a qualidade de efluentes industriais, dentre eles os de corantes têxteis. As técnicas mais utilizadas são a cloração, filtração, tratamentos floculantes e adsorção por Carvão Ativados. Porem, muitas vezes esses processos possuem desvantagens, como, por exemplo, o alto custo e alterações drásticas no pH. Assim tratamentos alternativos, como o uso de Moringa oleifera, veem sendo muito estudados. Este trabalho visou avaliar o potencial do uso das sementes de Moringa oleifera como adsorvente na remoção de corantes têxteis em meio aquoso. Para isso foi analisado a remoção do corante Direct Violet 51, utilizando pó das sementes. Foram realizados testes com diferentes tempos de contato nos valores de pH 2,5, 4,5 e 6,5. Posteriormente novos testes foram realizados, utilizando o sobrenadante e a biomassa das sementes, ambos na forma livre e imobilizada em alginato de calcio, bem como reutilização destes. Através da analise das amostras, notou-se que o processo de coagulação/floculação sobressaiu-se em...

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aims to test a new conceptual model based on the relationship between quality management (QM), environmental management maturity (EMM), adoption of external practices of green supply chain management (GSCM) (green purchasing and collaboration with customers) and green performance (GP) with data from 95 Brazilian firms with ISO 14001. To our knowledge, such links and relationships are not simultaneously identified and tested in the literature. The results indicate the validation of all of the research hypotheses. This paper highlights that an improvement in green performance will require attention to quality management, environmental management maturity, and green supply chain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Given the polarity dependent effects of transcranial direct current stimulation (tDCS) in facilitating or inhibiting neuronal processing, and tDCS effects on pitch perception, we tested the effects of tDCS on temporal aspects of auditory processing. We aimed to change baseline activity of the auditory cortex using tDCS as to modulate temporal aspects of auditory processing in healthy subjects without hearing impairment. Eleven subjects received 2mA bilateral anodal, cathodal and sham tDCS over auditory cortex in a randomized and counterbalanced order. Subjects were evaluated by the Random Gap Detection Test (RGDT), a test measuring temporal processing abilities in the auditory domain, before and during the stimulation. Statistical analysis revealed a significant interaction effect of time vs. tDCS condition for 4000 Hz and for clicks. Post-hoc tests showed significant differences according to stimulation polarity on RGDT performance: anodal improved 22.5% and cathodal decreased 54.5% subjects' performance, as compared to baseline. For clicks, anodal also increased performance in 29.4% when compared to baseline. tDCS presented polarity-dependent effects on the activity of the auditory cortex, which results in a positive or negative impact in a temporal resolution task performance. These results encourage further studies exploring tDCS in central auditory processing disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>Thirty-five lymph node samples were taken from animals with macroscopic lesions consistent with Mycobacterium bovis infection. The animals were identified by postmortem examination in an abattoir in the northwestern region of state of Parana, Brazil. Twenty-two of the animals had previously been found to be tuberculin skin test positive. Tissue samples were decontaminated by Petroff`s method and processed for acid-fast bacilli staining, culture in Stonebrink and Lowenstein-Jensen media and DNA extraction. Lymph node DNA samples were amplified by PCR in the absence and presence (inhibitor controls) of DNA extracted from M. bovis culture. Mycobacterium bovis was identified in 14 (42.4%) lymph node samples by both PCR and by culture. The frequency of PCR-positive results (54.5%) was similar to that of culture-positive results (51.5%, P > 0.05). The percentage of PCR-positive lymph nodes increased from 39.4% (13/33) to 54.5% (18/33) when samples that were initially PCR-negative were reanalysed using 2.5 mu l DNA (two samples) and 1 : 2 diluted DNA (three samples). PCR sensitivity was affected by inhibitors and by the amount of DNA in the clinical samples. Our results indicate that direct detection of M. bovis in lymph nodes by PCR may be a fast and useful tool for bovine tuberculosis epidemic management in the region.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As stated by the New Institutional Economics theory, transaction costs play a relevant role in economics and, according to the extent of such costs, agents make investment decisions. Actually, transaction costs may represent a disincentive to entrepreneurship. This work aims to verify whether transaction costs are related to investment rate and foreign direct investment rate (FDI) in different business environments. The results suggest that foreign investors do not have precise information about other countries as domestic investors do; as it is observed, only the relation between transaction costs and investment rate is significant. Furthermore, there is evidence that the business environments of BRIC countries are less developed when compared to business environments of other countries in the study

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present review will briefly summarize the interplay between coagulation and inflammation, highlighting possible effects of direct inhibition of factor Xa and thrombin beyond anticoagulation. Additionally, the rationale for the use of the new direct oral anticoagulants (DOACs) for indications such as cancer-associated venous thromboembolism (CAT), mechanical heart valves, thrombotic anti-phospholipid syndrome (APS), and heparin-induced thrombocytopenia (HIT) will be explored. Published data on patients with cancer or mechanical heart valves treated with DOAC will be discussed, as well as planned studies in APS and HIT. Although at the present time published evidence is insufficient for recommending DOAC in the above-mentioned indications, there are good arguments in favor of clinical trials investigating their efficacy in these contexts. Direct inhibition of factor Xa or thrombin may reveal interesting effects beyond anticoagulation as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the first evaluation of a novel molecular assay, the Speed-oligo Direct Mycobacterium tuberculosis (SO-DMT) assay, which is based on PCR combined with a dipstick for the detection of mycobacteria and the specific identification of M. tuberculosis complex (MTC) in respiratory specimens. A blind evaluation was carried out in two stages: first, under experimental conditions on convenience samples comprising 20 negative specimens, 44 smear- and culture-positive respiratory specimens, and 11 sputa inoculated with various mycobacterium-related organisms; and second, in the routine workflow of 566 fresh respiratory specimens (4.9% acid-fast bacillus [AFB] smear positives, 7.6% MTC positives, and 1.8% nontuberculous mycobacteria [NTM] culture positives) from two Mycobacterium laboratories. SO-DMT assay showed no reactivity in any of the mycobacterium-free specimens or in those with mycobacterium-related organisms. Compared to culture, the sensitivity in the selected smear-positive specimens was 0.91 (0.92 for MTC and 0.90 for NTM), and there was no molecular detection of NTM in a tuberculosis case or vice versa. With respect to culture and clinical data, the sensitivity, specificity, and positive and negative predictive values for the SO-DMT system in routine specimens were 0.76 (0.93 in smear positives [1.0 for MTC and 0.5 for NTM] and 0.56 in smear negatives [0.68 for MTC and 0.16 for NTM]), 0.99, 0.85 (1.00 in smear positives and 0.68 in smear negatives), and 0.97, respectively. Molecular misidentification of NTM cases occurred when testing 2 gastric aspirates from two children with clinically but not microbiologically confirmed lung tuberculosis. The SO-DMT assay appears to be a fast and easy alternative for detecting mycobacteria and differentiating MTC from NTM in smear-positive respiratory specimens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of InxAl1-xAs samples (0.51≪x≪0.55)coherently grown on InP was studied in order to measure the band-gap energy of the lattice matched composition. As the substrate is opaque to the relevant photon energies, a method is developed to calculate the optical absorption coefficient from the photoluminescence excitation spectra. The effect of strain on the band-gap energy has been taken into account. For x=0.532, at 14 K we have obtained Eg0=1549±6 meV

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare specificity and sensitivity of different biological markers that can be used in a forensic field to identify potentially dangerous drivers because of their alcohol habits. Methods: We studied 280 Swiss drivers after driving while under the alcohol influence. 33 were excluded for not having CDT N results, 247 were included (218 men (88%) and 29 women (12%). Mean age was 42,4 (SD:12, min: 20 max: 76). The evaluation of the alcohol consumption concerned the month before the CDT test and was considered as such after the interview: Heavy drinkers (>3 drinks per day): 60 (32.7%), < 3 drinks per day and moderate: 127 (51.4%) 114 (46.5%), abstinent: 60 (24.3%) 51 (21%). Alcohol intake was monitored by structured interviews, self-reported drinking habits and the C-Audit questionnaire as well as information provided by their family and general practitioner. Consumption was quantified in terms of standard drinks, which contain approximately 10 grams of pure alcohol (Ref. WHO). Results: comparison between moderate (less or equal to 3 drinks per day) and excessive drinkers (more than 3 drinks) Marker ROC area 95% CI cut-off sensitivity specificity CDT TIA 0.852 0.786-0917 2.6* 0.93 LR+1.43 0.35 LR-0.192 CDT N latex 0.875 0.821-0.930 2.5* 0.66 LR+ 6.93 0.90 LR- 0.369 Asialo+disialo-tf 0.881 0.826-0.936 1.2* 0.78 LR+4.07 0.80 LR-0.268 1.7° 0.66 LR+8.9 0.93 LR-0.360 GGT 0.659 0.580-0.737 85* 0.37 LR+2.14 0.83 LR-0.764 * cut-off point suggested by the manufacturer ° cut-off point suggested by our laboratory Conclusion: With the cut-off point established by the manufacturer, CDT TIA performed poorly in term of specificity. N latex CDT and CZE CDT were better, especially if a 1.7 cut-off is used with CZE