890 resultados para Diagnostic techniques and procedures
Resumo:
Environmental decay in porous masonry materials, such as brick and mortar, is a widespread problem concerning both new and historic masonry structures. The decay mechanisms are quite complex dependng upon several interconnected parameters and from the interaction with the specific micro-climate. Materials undergo aesthetical and substantial changes in character but while many studies have been carried out, the mechanical aspect has been largely understudied while it bears true importance from the structural viewpoint. A quantitative assessment of the masonry material degradation and how it affects the load-bearing capacity of masonry structures appears missing. The research work carried out, limiting the attention to brick masonry addresses this issue through an experimental laboratory approach via different integrated testing procedures, both non-destructive and mechanical, together with monitoring methods. Attention was focused on transport of moisture and salts and on the damaging effects caused by the crystallization of two different salts, sodium chloride and sodium sulphate. Many series of masonry specimens, very different in size and purposes were used to track the damage process since its beginning and to monitor its evolution over a number of years Athe same time suitable testing techniques, non-destructive, mini-invasive, analytical, of monitoring, were validated for these purposes. The specimens were exposed to different aggressive agents (in terms of type of salt, of brine concentration, of artificial vs. open-air natural ageing, …), tested by different means (qualitative vs. quantitative, non destructive vs. mechanical testing, punctual vs. wide areas, …), and had different size (1-, 2-, 3-header thick walls, full-scale walls vs. small size specimens, brick columns and triplets vs. small walls, masonry specimens vs. single units of brick and mortar prisms, …). Different advanced testing methods and novel monitoring techniques were applied in an integrated holistic approach, for quantitative assessment of masonry health state.
Resumo:
Among the fugues of the WTC II, there are some fugal techniques and procedures that were not explored in the first book. Here, the ‘fugal techniques’ include parallel entries (as used in the fugues in D-sharp minor, G minor and B-flat minor) and double counterpoint at the tenth or twelfth as well as fifteenth (as used in the fugues in G minor and B major). The ‘fugal procedures’, on the other hand, refer to meticulously planned multi-exposition architecture (as seen in the fugues in F-sharp minor exploiting two subsidiary subjects, and B-flat minor exploiting inversion and stretto) and a form in which the appearance of the subsidiary subject is gradually predicted in the fugal discourse (viz. C-sharp minor, G-sharp minor and B major). All these new ideas helped Bach to write more dramatic, more profound fugues for WTC II. The paper will consider how Bach came to acquire the new techniques and to use them in such ways, and what motivated him to adopt these new compositional approaches. Do they offer any clues for our better understanding of why Bach compiled the WTC II?
Resumo:
Mode of access: Internet.
Resumo:
The satellite ERS-1 was launched in July 1991 in a period of high solar activity. Sparse laser tracking and the failure of the experimental microwave system (PRARE) compounded the orbital errors which resulted from mismodelling of atmospheric density and hence surface forces. Three attempts are presented here to try and refine the coarse laser orbits of ERS-1, made prior to the availability of the full altimetric dataset. The results of the first attempt indicate that by geometrically modelling the satellite shape some improvement in orbital precision may be made for any satellite; especially one where no area tables already exist. The second and third refinement attempts are based on the introduction of data from some second satellite; in these examples SPOT-2 and TOPEX/Poseidon are employed. With SPOT-2 the method makes use of the orbital similarities to produce along-track corrections for the more fully tracked SPOT-2. Transferring these corrections to ERS-1 produces improvements in the precise orbits thus determined. With TOPEX/Poseidon the greater altitude results in a more precise orbit (gravity field and atmospheric errors are of less importance). Thus, by computing height differences at crossover points of the TOPEX/Poseidon and ERS-1 ground tracks the poorer orbit of ERS-1 may be improved by the addition of derived radial corrections. In the positive light of all three results several potential modification are suggested and some further avenues of investigation indicated.
Resumo:
OBJECTIVE: The diagnosis of Alzheimer's disease (AD) remains difficult. Lack of diagnostic certainty or possible distress related to a positive result from diagnostic testing could limit the application of new testing technologies. The objective of this paper is to quantify respondents' preferences for obtaining AD diagnostic tests and to estimate the perceived value of AD test information. METHODS: Discrete-choice experiment and contingent-valuation questions were administered to respondents in Germany and the United Kingdom. Choice data were analyzed by using random-parameters logit. A probit model characterized respondents who were not willing to take a test. RESULTS: Most respondents indicated a positive value for AD diagnostic test information. Respondents who indicated an interest in testing preferred brain imaging without the use of radioactive markers. German respondents had relatively lower money-equivalent values for test features compared with respondents in the United Kingdom. CONCLUSIONS: Respondents preferred less invasive diagnostic procedures and tests with higher accuracy and expressed a willingness to pay up to €700 to receive a less invasive test with the highest accuracy.
Resumo:
Incomplete reporting has been identified as a major source of avoidable waste in biomedical research.
Essential information is often not provided in study reports, impeding the identification, critical
appraisal, and replication of studies. To improve the quality of reporting of diagnostic accuracy
studies, the Standards for Reporting Diagnostic Accuracy (STARD) statement was developed. Here
we present STARD 2015, an updated list of 30 essential items that should be included in every
report of a diagnostic accuracy study. This update incorporates recent evidence about sources of
bias and variability in diagnostic accuracy and is intended to facilitate the use of STARD. As such,
STARD 2015 may help to improve completeness and transparency in reporting of diagnostic accuracy
studies.
Resumo:
BACKGROUND: Outcome assessment can support the therapeutic process by providing a way to track symptoms and functionality over time, providing insights to clinicians and patients, as well as offering a common language to discuss patient behavior/functioning. OBJECTIVES: In this article, we examine the patient-based outcome assessment (PBOA) instruments that have been used to determine outcomes in acupuncture clinical research and highlight measures that are feasible, practical, economical, reliable, valid, and responsive to clinical change. The aims of this review were to assess and identify the commonly available PBOA measures, describe a framework for identifying appropriate sets of measures, and address the challenges associated with these measures and acupuncture. Instruments were evaluated in terms of feasibility, practicality, economy, reliability, validity, and responsiveness to clinical change. METHODS: This study was a systematic review. A total of 582 abstracts were reviewed using PubMed (from inception through April 2009). RESULTS: A total of 582 citations were identified. After screening of title/abstract, 212 articles were excluded. From the remaining 370 citations, 258 manuscripts identified explicit PBOA; 112 abstracts did not include any PBOA. The five most common PBOA instruments identified were the Visual Analog Scale, Symptom Diary, Numerical Pain Rating Scales, SF-36, and depression scales such as the Beck Depression Inventory. CONCLUSIONS: The way a questionnaire or scale is administered can have an effect on the outcome. Also, developing and validating outcome measures can be costly and difficult. Therefore, reviewing the literature on existing measures before creating or modifying PBOA instruments can significantly reduce the burden of developing a new measure.
Resumo:
RESUMO - A monitorização individual dos trabalhadores (dosimetria individual) é obrigatória (Decreto Regulamentar n.o 9/90, de 19 de Abril) para os profissionais de saúde que desempenham funções com risco de exposição à radiação X, quando classificados como categoria A. Apesar disso, a exposição a radiações ionizantes é frequentemente pouco, ou mesmo nada, valorizada pelos profissionais de saúde. O presente estudo, realizado no contexto de intervenções cirúrgicas de ortopedia, teve por objectivos: • avaliar a dose de radiação em diferentes zonas durante as cirurgias ortopédicas; • estimar a dose de exposição a radiações ionizantes dos profissionais de saúde, em função das suas posições, predominantemente adoptadas durante o acto cirúrgico; • sensibilizar os profissionais de saúde para a utilização correcta da dosimetria individual e para a adopção das medidas de protecção radiológica. A avaliação do risco foi efectuada através de: 1) medições preliminares com recurso a um fantoma colocado a 50 cm e a 100 cm do eixo central do feixe de radiação e em direcções de 45°, 90° e 135°; 2) medições durante uma cirurgia ortopédica em «localizações » correspondentes às gónadas, ao cristalino e às mãos dos profissionais de saúde intervenientes na cirurgia (ortopedistas, enfermeiros instrumentistas); 3) medições ao nível do topo da mesa (posição do anestesista) e ao nível do comando do equipamento emissor de raios X (técnico de radiologia); 4) determinação do tempo de utilização dos raios X durante as cirurgias ortopédicas; 5) cálculo da estimativa do número anual de cirurgias ortopédicas realizadas, com base nos registos existentes. Assumindo a não utilização de aventais plúmbeos os valores máximos medidos foram de 2,5 mSv/h (ao nível das gónadas), de 0,6 mSv/h ao nível do cristalino e de 1 mSv/ h ao nível das mãos dos ortopedistas e dos enfermeiros instrumentistas (que se situavam próximo do feixe de raios X, a 50 cm do feixe de radiação). A estimativa de exposição anual (dose equivalente) para os profissionais que operam junto ao feixe de radiação X foi de: • Ortopedistas — 20,63 a 68,75 mSv (gónadas), 4,95 a 16,50 mSv (cristalino) e 8,25 a 27,50 mSv (mãos); • Enfermeiros instrumentistas — 130,63 a 151,25 mSv (gónadas), 31,35 a 36,30 mSv (cristalino) e 52,25 a Os profissionais que ocupam posições mais afastadas do feixe (por exemplo: anestesistas) terão doses de radiação mais reduzidas, embora estas possam ainda ser importantes ao nível das gónadas na zona do topo da mesa (anestesista). Conclui-se que a exposição profissional em blocos operatórios pode implicar, em cirurgia ortopédica, a sujeição a níveis de exposição consideráveis, o que permite classificar estes profissionais de categoria A, justificando a utilização obrigatória (e correcta de acordo com as recomendações) da dosimetria individual e a adopção de medidas de protecção radiológica, tantas vezes negligenciadas.
Resumo:
INTRODUCTION: In orthodontics, determining the facial type is a key element in the prescription of a correct diagnosis. In the early days of our specialty, observation and measurement of craniofacial structures were done directly on the face, in photographs or plaster casts. With the development of radiographic methods, cephalometric analysis replaced the direct facial analysis. Seeking to validate the analysis of facial soft tissues, this work compares two different methods used to determining the facial types, the anthropometric and the cephalometric methods. METHODS: The sample consisted of sixty-four Brazilian individuals, adults, Caucasian, of both genders, who agreed to participate in this research. All individuals had lateral cephalograms and facial frontal photographs. The facial types were determined by the Vert Index (cephalometric) and the Facial Index (photographs). RESULTS: The agreement analysis (Kappa), made for both types of analysis, found an agreement of 76.5%. CONCLUSIONS: We concluded that the Facial Index can be used as an adjunct to orthodontic diagnosis, or as an alternative method for pre-selection of a sample, avoiding that research subjects have to undergo unnecessary tests.
Resumo:
The impact of plasma technologies is growing both in the academic and in the industrial fields. Nowadays, a great interest is focused in plasma applications in aeronautics and astronautics domains. Plasma actuators based on the Magneto-Hydro-Dynamic (MHD) and Electro- Hydro-Dynamic (EHD) interactions are potentially able to suitably modify the fluid-dynamics characteristics around a flying body without utilizing moving parts. This could lead to the control of an aircraft with negligible response time, more reliability and improvements of the performance. In order to study the aforementioned interactions, a series of experiments and a wide number of diagnostic techniques have been utilized. The EHD interaction, realized by means of a Dielectric Barrier Discharge (DBD) actuator, and its impact on the boundary layer have been evaluated by means of two different experiments. In the first one a three phase multi-electrode flat panel actuator is used. Different external flow velocities (from 1 to 20m/s) and different values of the supplied voltage and frequency have been considered. Moreover a change of the phase sequence has been done to verify the influence of the electric field existing between successive phases. Measurements of the induced speed had shown the effect of the supply voltage and the frequency, and the phase order in the momentum transfer phenomenon. Gains in velocity, inside the boundary layer, of about 5m/s have been obtained. Spectroscopic measurements allowed to determine the rotational and the vibrational temperature of the plasma which lie in the range of 320 ÷ 440°K and of 3000 ÷ 3900°K respectively. A deviation from thermodynamic equilibrium had been found. The second EHD experiment is realized on a single electrode pair DBD actuator driven by nano-pulses superimposed to a DC or an AC bias. This new supply system separates the plasma formation mechanism from the acceleration action on the fluid, leading to an higher degree of the control of the process. Both the voltage and the frequency of the nano-pulses and the amplitude and the waveform of the bias have been varied during the experiment. Plasma jets and vortex behavior had been observed by means of fast Schlieren imaging. This allowed a deeper understanding of the EHD interaction process. A velocity increase in the boundary layer of about 2m/s had been measured. Thrust measurements have been performed by means of a scales and compared with experimental data reported in the literature. For similar voltage amplitudes thrust larger than those of the literature, had been observed. Surface charge measurements led to realize a modified DBD actuator able to obtain similar performances when compared with that of other experiments. However in this case a DC bias replacing the AC bias had been used. MHD interaction experiments had been carried out in a hypersonic wind tunnel in argon with a flow of Mach 6. Before the MHD experiments a thermal, fluid-dynamic and plasma characterization of the hypersonic argon plasma flow have been done. The electron temperature and the electron number density had been determined by means of emission spectroscopy and microwave absorption measurements. A deviation from thermodynamic equilibrium had been observed. The electron number density showed to be frozen at the stagnation region condition in the expansion through the nozzle. MHD experiments have been performed using two axial symmetric test bodies. Similar magnetic configurations were used. Permanent magnets inserted into the test body allowed to generate inside the plasma azimuthal currents around the conical shape of the body. These Faraday currents are responsible of the MHD body force which acts against the flow. The MHD interaction process has been observed by means of fast imaging, pressure and electrical measurements. Images showed bright rings due to the Faraday currents heating and exciting the plasma particles. Pressure measurements showed increases of the pressure in the regions where the MHD interaction is large. The pressure is 10 to 15% larger than when the MHD interaction process is silent. Finally by means of electrostatic probes mounted flush on the test body lateral surface Hall fields of about 500V/m had been measured. These results have been used for the validation of a numerical MHD code.
Resumo:
Agricultural crops can be damaged by funguses, insects, worms and other organisms that cause diseases and decrease the yield of production. The effect of these damaging agents can be reduced using pesticides. Among them, triazole compounds are effective substances against fungus; for example, Oidium. Nevertheless, it has been detected that the residues of these fungicides in foods as well as in derivate products can affect the health of the consumers. Therefore, the European Union has established several regulations fixing the maximum residue of pesticide levels in a wide range of foods trying to assure the consumer safety. Hence, it is very important to develop adequate methods to determine these pesticide compounds. In most cases, gas or liquid chromatographic (GC, LC) separations are used in the analysis of the samples. But firstly, it is necessary to use proper sample treatments in order to preconcentrate and isolate the target analytes. To reach this aim, microextraction techniques are very effective tools; because allow to do both preconcentration and extraction of the analytes in one simple step that considerably reduces the source of errors. With these objectives, two remarkable techniques have been widely used during the last years: solid phase microextraction (SPME) and liquid phase microextraction (LPME) with its different options. Both techniques that avoid the use or reduce the amount of toxic solvents are convenient coupled to chromatographic equipments providing good quantitative results in a wide number of matrices and compounds. In this work simple and reliable methods have been developed using SPME and ultrasound assisted emulsification microextraction (USAEME) coupled to GC or LC for triazole fungicides determination. The proposed methods allow confidently determine triazole concentrations of μg L‐1 order in different fruit samples. Chemometric tools have been used to accomplish successful determinations. Firstly, in the selection and optimization of the variables involved in the microextraction processes; and secondly, to overcome the problems related to the overlapping peaks. Different fractional factorial designs have been used for the screening of the experimental variables; and central composite designs have been carried out to get the best experimental conditions. Trying to solve the overlapping peak problems multivariate calibration methods have been used. Parallel Factor Analysis 2 (PARAFAC2), Multivariate Curve Resolution (MCR) and Parallel Factor Analysis with Linear Dependencies (PARALIND) have been proposed, the adequate algorithms have been used according to data characteristics, and the results have been compared. Because its occurrence in Basque Country and its relevance in the production of cider and txakoli regional wines the grape and apple samples were selected. These crops are often treated with triazole compounds trying to solve the problems caused by the funguses. The peel and pulp from grape and apple, their juices and some commercial products such as musts, juice and cider have been analysed showing the adequacy of the developed methods for the triazole determination in this kind of fruit samples.
Resumo:
In order to better understand the stratified combustion, the propagation of flame through stratified mixture field in laminar and turbulent flow conditions has been studied by using combined PIV/PLIF techniques. A great emphasis was placed on developing methods to improve the accuracy of local measurements of flame propagation. In particular, a new PIV approach has been developed to measure the local fresh gas velocity near preheat zone of flame front. To improve the resolution of measurement, the shape of interrogation window has been continuously modified based on the local flame topology and gas expansion effect. Statistical analysis of conditioned local measurements by the local equivalence ratio of flames allows the characterization of the properties of flame propagation subjected to the mixture stratification in laminar and turbulent flows, especially the highlight of the memory effect.
Resumo:
This paper demonstrates the application of laser Doppler velocimetry (LDV) and particle image velocimetry (PIV) techniques to a particle-laden reacting flow of pulverized coal. A laboratory-scale open-type annular burner is utilized to generate velocity profiles of coal particles and micrometric alumina particles. Pair-wise two-component LDV measurements and high-speed stereo PIV measurements provide three-dimensional velocity components of the flow field. A detailed comparison of velocities for alumina and coal particle seeding revealed differences attributed to the wide size distribution of coal particles. In addition, the non-spherical shape and high flame luminosity associated with coal particle combustion introduces noise to the Mie scatter images. The comparison of mean and RMS velocities measured by LDV and PIV techniques showed that PIV measurements are affected by the wide size distribution of coal particles, whereas LDV measurements become biased toward the velocity of small particles, as signals from large particles are rejected. This small-particle bias is also reflected in the spectral characteristics for both techniques, which are in good agreement within the range of frequencies accessible. PIV measurements showed an expected lack of response of large coal particles to the turbulence fluctuations. The overall good agreement between LDV and PIV measurements demonstrates the applicability of the high-speed PIV technique to a particle-laden, high luminosity coal flame while highlighting some of its limitations. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.