957 resultados para Desvios de setup
Resumo:
Mestrado em Radioterapia
Resumo:
Mestrado em Radioterapia
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
This paper addresses the capacitated lot sizing problem (CLSP) with a single stage composed of multiple plants, items and periods with setup carry-over among the periods. The CLSP is well studied and many heuristics have been proposed to solve it. Nevertheless, few researches explored the multi-plant capacitated lot sizing problem (MPCLSP), which means that few solution methods were proposed to solve it. Furthermore, to our knowledge, no study of the MPCLSP with setup carry-over was found in the literature. This paper presents a mathematical model and a GRASP (Greedy Randomized Adaptive Search Procedure) with path relinking to the MPCLSP with setup carry-over. This solution method is an extension and adaptation of a previously adopted methodology without the setup carry-over. Computational tests showed that the improvement of the setup carry-over is significant in terms of the solution value with a low increase in computational time.
Resumo:
A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4', 4 ''-methylidynetris (N, N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO(-) in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 mu g of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L(-1) ClO(-), a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L(-1) ClO(-), a detection limit of 6.0 mu g L(-1) ClO(-), a sampling throughput of 84 determinations per hour, and a waste generation of 432 mu L per determination.
Resumo:
Sistema desenvolvido e aplicado durante a Opera????o Tormenta para identificar suspeitos de fraudar as provas objetivas de concursos p??blicos. O Sistema de Prospec????o e An??lise de Desvios em Exames (Spade-PRO) serviu de base para auditar os concursos p??blicos realizados pela Pol??cia Federal nos anos de 2001, 2004 e 2009. Em raz??o da efetividade do sistema, a sua utiliza????o foi estendida para os concursos p??blicos realizados pelas seguintes institui????es: Ag??ncia Nacional de Avia????o Civil (Anac), Ag??ncia Brasileira de Intelig??ncia (Abin), Tribunal de Justi??a do Estado de S??o Paulo (TJSP) e para o Exame da Ordem dos Advogados do Brasil (OAB). Os dados obtidos, utilizados nas a????es criminais que apuraram a responsabilidade pelas fraudes, foram fundamentais para evitar o ingresso ilegal de pessoas no servi??o p??blico. O sistema ser?? utilizado pela Pol??cia Federal para auditar os pr??ximos concursos do ??rg??o e est?? dispon??vel para ser aplicado por qualquer institui????o que solicite a realiza????o da auditoria em seus processos seletivos
Resumo:
Barreiras para a precisão em radioterapia: delimitação de volumes, erros de posicionamento, movimento dos órgãos. Revolução imagiológica na monitorização do tratamento: radiografia, EPID, CONE-BEAM CT. Objectivo do estudo: quantificar desvios de posicionamento em doentes com patologias de cabeça e pescoço e próstata nos tratamentos de Radioterapia.
Resumo:
Introdução – Numa era em que os tratamentos de Radioterapia Externa (RTE) exigem cada vez mais precisão, a utilização de imagem médica permitirá medir, quantificar e avaliar o impacto do erro provocado pela execução do tratamento ou pelos movimentos dos órgãos. Objetivo – Analisar os dados existentes na literatura acerca de desvios de posicionamento (DP) em patologias de cabeça e pescoço (CP) e próstata, medidos com Cone Beam Computed Tomography (CBCT) ou Electronic Portal Image Device (EPID). Metodologia – Para esta revisão da literatura foram pesquisados artigos recorrendo às bases de dados MEDLINE/PubMed e b-on. Foram incluídos artigos que reportassem DP em patologias CP e próstata medidos através de CBCT e EPID. Seguidamente foram aplicados critérios de validação, que permitiram a seleção dos estudos. Resultados – Após a análise de 35 artigos foram incluídos 13 estudos e validados 9 estudos. Para tumores CP, a média (μ) dos DP encontra-se entre 0,0 e 1,2mm, com um desvio padrão (σ) máximo de 1,3mm. Para patologias de próstata observa-se μDP compreendido entre 0,0 e 7,1mm, com σ máximo de 7,5mm. Discussão/Conclusão – Os DP em patologias CP são atribuídos, maioritariamente, aos efeitos secundários da RTE, como mucosite e dor, que afetam a deglutição e conduzem ao emagrecimento, contribuindo para a instabilidade da posição do doente durante o tratamento, aumentando as incertezas de posicionamento. Os movimentos da próstata devem-se principalmente às variações de preenchimento vesical, retal e gás intestinal. O desconhecimento dos DP afeta negativamente a precisão da RTE. É importante detetá-los e quantificá-los para calcular margens adequadas e a magnitude dos erros, aumentando a precisão da administração de RTE, incluindo o aumento da segurança do doente. - ABSTRACT - Background and Purpose – In an era where precision is an increasing necessity in external radiotherapy (RT), modern medical imaging techniques provide means for measuring, quantifying and evaluating the impact of treatment execution and movement error. The aim of this paper is to review the current literature on the quantification of setup deviations (SD) in patients with head and neck (H&N) or prostate tumors, using Cone Beam Computed Tomography (CBCT) or Electronic Portal Image Device (EPID). Methods – According to the study protocol, MEDLINE/PubMed and b-on databases were searched for trials, which were analyzed using selection criteria based on the quality of the articles. Results – After assessment of 35 papers, 13 studies were included in this analysis and nine were authenticated (6 for prostate and 3 for H&N tumors). The SD in the treatment of H&N cancer patients is in the interval of 0.1 to 1.2mm, whereas in prostate cancer this interval is 0.0 to 7.1mm. Discussion – The reproducibility of patient positioning is the biggest barrier for higher precision in RT, which is affected by geometrical uncertainty, positioning errors and inter or intra-fraction organ movement. There are random and systematic errors associated to patient positioning, introduced since the treatment planning phase or through physiological organ movement. Conclusion – The H&N SD are mostly assigned to the Radiotherapy adverse effects, like mucositis and pain, which affect swallowing and decrease secretions, contributing for the instability of patient positioning during RT treatment and increasing positioning uncertainties. Prostate motion is mainly related to the variation in bladder and rectal filling. Ignoring SD affects negatively the accuracy of RT. Therefore, detection and quantification of SD is crucial in order to calculate appropriate margins, the magnitude of error and to improve accuracy in RTE and patient safety.
Resumo:
Mestrado em Radioterapia
Resumo:
Mestrado em Radioterapia
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação apresentada para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ciência Política e Relações Internacionais – Área de Especialização em Ciência Política.
Resumo:
As deformidades axiais dos membros inferiores constituem um dos principais motivos de consulta na área de Ortopedia Infantil. Esta situação deve-se, por um lado, ao facto de haver uma grande percentagem de crianças (cerca de 20%) que apresentam uma deformidade fisiológica durante o desenvolvimento e, por outro, à «tradição» existente, segundo a qual estes desvios necessitam de um tratamento, usualmente por calçado ortopédico. Torna-se, por isso, imperioso destrinçar o fisiológico do patológico, diferenciar as diferentes etiologias e corrigi-las precocemente medicamente e, ainda, determinar quando uma deformidade é passível de correcção espontânea ou quando exige uma terapêutica cirúrgica.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica
Resumo:
Polyhydroxyalkanoates (PHAs) are biosynthetic polyesters, biodegradable and biocompatible making them of great interest for industrial purposes. The use of low value substrates with mixed microbial communities (MMC) is a strategy currently used to decrease the elevated PHA production costs. PHA production process requires an important step for selection and enrichment of PHA-storing microorganisms which is usually carried out in a Sequencing Batch Reactor (SBR). The aim of this study was to optimize the PHA accumulating culture selection stage using a 2-stage Continuous Stirrer Tank Reactor (CSTR) system. The system was composed by two separate feast and famine bioreactors operated continuously, mimicking the feast and famine phases in a SBR system. Acetate was used as carbon source and biomass seed was highly enriched in Plasticicumulans acidivorans obtained from activated sludge. The system was operated under two different sets of conditions (setup 1 and 2), maintaining a system total retention time of 12 hours and an OLR of 2.25 Cmmol/L.h-1. An average PHB-content of 3.3 % wt was obtained in setup 1 and 4.8% wt in setup 2. Several other experiments were performed in order to better understand the continuous system behaviour, using biomass from the continuous system. With the fed-batch experiment a maximum of 8.1% PHB was stored and the maximum substrate uptake and specific growth rates obtained in the growth experiment (1.15 Cmol Cmol-1.h-1 and 0.53 Cmol Cmol-1.h-1) were close to the ones from continuous system (1.12 Cmol Cmol-1.h-1 and 0.59 Cmol Cmol-1.h-1). The microbial community was characterized trough microscopic visualization, Denaturing Gradient Gel Electrophoresis (DGGE) analysis and Fluorescent in situ hybridization (FISH). The last studied performed mimicked the continuous system by building up a SBR system with all the same operational conditions while adding an extra acetate dosage during the 12 h cycle, simulating the substrate passing from the feast to the famine reactors under continuous operation. It was shown that possibly the continuous system was not able to efficiently select for PHB storing organisms under the operational conditions imposed, although the selected culture was capable of consuming the substrate and grow fast. This main conclusion might have resulted from two major factors affecting the system performance: the ammonium concentration in the Feast reactor and the amount of substrate leaching from the Feast to the Famine reactor.