956 resultados para Coronal Leakage
Resumo:
Purpose: To evaluate the effects of coronal leakage on concentration of hydrogen ions (pH) and calcium release of several calcium hydroxide pastes, over different periods of time. Material and Methods: Fifty extracted human mandibular central incisors (n=10) were instrumented up to the F2 instrument and assigned to the following intracanal dressing: G1- Calen, G2- Calen with 0.4% chlorhexidine (CHX), G3- Calcium hydroxide with camphorated paramonochlorophenol (CPMC) and glycerin, G4- Calen, but temporary filling material maintained during all test (positive control) and G5- Root canal without intracanal dressing (negative control). All groups were immersed in distilled water for 7 days. In sequence, the temporary filling materials were removed, except in controls groups. All specimens were individually mounted on a specific device and only its root again immersed in distilled water. Concentration of hydrogen ions and calcium release by calcium hydroxide pastes in distilled water were evaluated in 24h, 7, 14 and 28 days. The results were submitted to ANOVA test (p = 0.05). After 28 days, root canals from experimental groups were examined in SEM. Results: G1, G2, G3 and G4 presented similar pH values and calcium release and did not differ from each other (p>0.05), up to 7 days. After this time G1, G2 and G3 presented values lower values than G4 (p<0.05). In SEM analysis, calcium hydroxide residues were observed in all experimental groups. Conclusions: After 7 days, coronal leakage decreased the concentration of hydrogen ions and calcium ion release provided by all calcium hydroxide pastes.
Resumo:
The purpose of this study was to evaluate in vivo the response of the periradicular tissues after endodontic treatment and root filling with Epiphany/Resilon (Penntron Clinical Technologies, LLC, Wallingford, CT) or gutta percha and new Sealapex (SybronEndo, Glendora, CA) in dogs' teeth with or without coronal restoration. Teeth without coronal restorations were used to assess the influence of continuous exposure to the oral environment on the periradicular tissues. Sixty root canals with vital pulps in three dogs were instrumented and obturated in a single session and randomly assigned to one of four groups as follows. group 1: root canal filling with Epiphany/Resilon with coronal restoration, group 2: root canal filling with Sealapex sealer and gutta percha with restoration, group 3: root canal filling with Epiphany/Resilon without restoration, and group 4: root canal filling with Sealapex sealer and gutta percha without coronal restoration. After 90 days, the animals were euthanized, and the maxillas and mandibles were removed and submitted for histologic processing. Longitudinal sections were obtained and stained with hematoxylin and eosin, Mallory's trichrome, and Brown and Brenn stains and examined under light microscopy. There were significant differences found between the four groups (p < 0.05). The results showed that roots canals filled with Epiphany/Resilon, with coronal restoration, had significantly less periradicular inflammation than roots canals filled with gutta percha and Sealapex, with coronal restoration (p = 0.021). No significant difference was observed in the intensity of inflammation between roots canals filled with Epiphany/ Resilon with no restoration and roots filled with gutta percha and Sealapex with restoration (p = 0.269). Roots canals filled with gutta percha and Sealapex sealer without coronal restoration showed the greatest degree of periradicular inflammation.
Resumo:
Foi propósito deste estudo analisar a influência da infiltração marginal coronária no comportamento dos tecidos periapicais de dentes de cães após obturação de canal e preparo para pino. Quarenta canais de dentes de cães foram instrumentados e obturados pela técnica da condensação lateral com cones de guta percha e os cimentos Roth e Sealer 26. Após preparo para pino, o remanescente da obturação foi protegido ou não com um plug do cimento temporário Lumicon. Após exposição ao meio oral por 90 dias, os animais foram sacrificados e as peças preparadas para análise histomorfológica. A técnica de Brown e Brenn mostrou 70% de casos com infiltração de microrganismos para o cimento Roth e 20% com o Sealer 26. Quando um plug de Lumicon foi empregado ocorreu 30% de casos de infiltração de microrganismos com o cimento Roth e 0,0% com o cimento Sealer 26. Reação inflamatória crônica foi mais freqüentemente observada com o cimento Roth do que com o Sealer 26. Foi concluído que o plug de Lumicon é eficiente no controle da infiltração coronária (p=0.05) e que o Sealer 26 foi mais biocompatível e selou melhor os canais radiculares do que o cimento Roth (p=0.01).
Resumo:
The purpose of this study was to evaluate the influence of coronal leakage on the healing of dogs' periapical tissues after root canal filling, post space preparation and protection or not with a temporary sealer plug. Forty root canals of dogs' teeth were instrumented and filled by the lateral condensation technique with gutta-percha points and Endomethasone or CRCS sealers. After post space preparation, the remaining filling material was protected or not with a plug of temporary Coltosol sealer and exposed to the oral environment for 90 days. Thereafter, the animals were sacrificed and the specimens were removed and prepared for histomorphological and histobacteriological analysis. The findings revealed 35% of microbial leakage in the groups without plugs and 15% of leakage in the groups with plugs. Statistical analysis showed that the use of a Coltosol plug improved significantly the histomorphological results regardless of the type of root canal sealer (p=0.05) and that CRCS and Endomethasone sealers showed similar results (p>0.05).
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Introdução: A Endodontia é a especialidade da Medicina Dentária responsável pelo estudo e tratamento da câmara pulpar, de todo o sistema de canais radiculares e dos tecidos periapicais, bem como das doenças que os afetam. O selamento da porção coronária dos dentes alvo de tratamento endodôntico apresenta-se como um critério determinante no sucesso ou insucesso do tratamento. São vários os fatores que podem proporcionar um correto selamento coronário evitando assim a microinfiltração de microorganismos no sistema de canais radiculares. Entre estes fatores destacam-se o tratamento pré-endodôntico, a correta e eficaz instrumentação e desinfeção dos canais radiculares, a aplicação de materiais de selamento imediato, o número de sessões em que é concluído o tratamento e ainda a restauração provisória e definitiva do dente tratado endodonticamente. Objetivos: A elaboração deste trabalho de revisão teve como principais objetivos aprofundar o conhecimento sobre o selamento coronário tendo em conta as consequências deste processo no prognóstico de dentes alvo de tratamento endodôntico, bem como, os meios a utilizar pelo clínico para prevenir a microinfiltração através da porção coronária e os materiais mais indicados para que o selamento seja alcançado. Materiais e Métodos: Foi realizada uma pesquisa bibliográfica de artigos científicos disponíveis nas bases de dados eletrónicas MEDLINE/Pubmed, Science Direct, Scielo e B-on. As palavras-chave utilizadas nesta pesquisa foram: Coronal Seal, Coronal Microleakage, Coronal Leakage, Temporary Restauration, Temporary Filling Materials, Restauration in Endodontics, Post and Core Restauration, Restorative Materials. Esta pesquisa foi realizada entre Março de 2016 e Maio do mesmo ano e dela resultou a seleção de 132 artigos publicados entre 1985 e 2016, primeiramente pela leitura do titulo e do abstract. Após a leitura completa dos artigos excluíram-se 94 por não se terem considerado relevantes para a elaboração desta revisão bibliográfica, obtendo-se um total de 38 artigos utilizados. Foi também realizada uma pesquisa bibliográfica na biblioteca da Universidade Fernando Pessoa, na secção dedicada à Endodontia, da qual resultou a seleção dos manuais que se encontram descritos pormenorizadamente na bibliografia. Conclusão: O Médico Dentista deve estar sensibilizado para as implicações que o selamento coronário tem para o sucesso do tratamento endodôntico, uma vez que este pode afetar o resultado de todo o tratamento.
Resumo:
This study aimed to evaluate, ex vivo, the nanoleakage in dentinal tubules, the linear infiltration of silver nitrate in the dentin wall/root-end filling material interface, and the presence of gaps in this interface in root-end cavities filled with 4 filling materials. Forty-eight disto-buccal root canals of maxillary molars were instrumented and filled. Retrograde cavities were prepared with ultrasonic points (apical 2 mm). The samples were divided into 2 control groups (n = 4) and 4 experimental groups (n = 10): Group I white mineral trioxide aggregate (MTA); Group II Super EBA; Group III Portland cement; and Group IV Sealer 26. After 1 week, the specimens were subjected to silver nitrate and prepared for SEM (backscattered electrons). In the apical-apical segment, an area with significantly higher leakage was observed for Super EBA, followed by Portland cement, MTA, and Sealer 26 (P = 0.0054). In the medium and cervical segments, all materials showed the same leakage behavior (P = 0.1815 and P = 0.1723, respectively). The linear infiltration at the dentin wall/root-end filling material interface was higher with Super EBA than the other groups. No differences in the percentage of gaps along the 3 mm of dentin wall/root-end filling material interface between the 4 materials were evident (P > 0.05). Nanoleakage occurred mainly in the apical segment of the samples, and Super EBA showed the highest values. The area and linear leakage were lower in the middle and coronal segments, regardless of the root-end filling material. No material perfectly sealed the root-end cavities, which allowed for the leakage occurrence. Microsc. Res. Tech. 75:796800, 2012. (C) 2011 Wiley Periodicals, Inc.
Resumo:
Introdução: O adequado selamento do sistema de canais radiculatres (SCR) obtido através da obturação, evita a infiltração de micro-organismos entre as paredes do canal radicular e o material obturador, reduzindo a possibilidade de insucesso do tratamento endodôntico (TE). A falta de selamento coronal, o atraso da colocação da restauração permanente, a fratura da restauração coronal, assim como uma espessura inadequada da restauração provisória, inferior a 4mm, podem, entre outros factores, ser predisponentes para a recontaminação do SCR obturado. Sendo o selamento da entrada do SCR uma importante etapa do TE, neste estudo pretendeu-se avaliar diferentes materiais para tal procedimento, avaliando qual o material que proporciona menor infiltração. Materiais e métodos: Neste estudo foram utilizados 70 dentes humanos monocanalares, que foram divididos aleatoriamente em 6 grupos. Grupo I (15 dentes) foram selados com ionómero de vidro modificado por resina (Ionoseal - VOCO®), Grupo II (15 dentes) foram selados com ionómero de vidro modicifado por resina (GC Fuji II LC- GA America®), Grupo III (15 dentes) foram selados por um compósito fluído (GrandioSO Heavy Flow - VOCO®), Grupo IV (15 dentes) foram selados por um compósito nanohíbrido (GrandioSO - VOCO®). O Grupo V (5 dentes) e o Grupo VI (5 dentes) foram usados como controlo negativo e positivo, respectivamente. Os dentes foram submetidos a termociclagem de 500 ciclos, de 60 segundos de duração cada um, com variações de temperatura de 5°C - 55°C. Em seguida, foram imersos em corante azul de metileno a 2% para avaliação da infiltração dos materiais. Resultados: Em geral, Ionoseal® demonstrou maior infiltração de corante que os outros materiais, e quando comparado com os demais grupos a diferença foi significativa. Porem entre os grupos 1, 2 e 3 não houve diferença estatística significante. Conclusões: LC Fuji II®, GrandioSo® Nano partícula Flow e GrandioSo® Nano partícula podem ser usados como barreira intracanalar.
Resumo:
Analytical expressions are derived for the mean and variance, of estimates of the bispectrum of a real-time series assuming a cosinusoidal model. The effects of spectral leakage, inherent in discrete Fourier transform operation when the modes present in the signal have a nonintegral number of wavelengths in the record, are included in the analysis. A single phase-coupled triad of modes can cause the bispectrum to have a nonzero mean value over the entire region of computation owing to leakage. The variance of bispectral estimates in the presence of leakage has contributions from individual modes and from triads of phase-coupled modes. Time-domain windowing reduces the leakage. The theoretical expressions for the mean and variance of bispectral estimates are derived in terms of a function dependent on an arbitrary symmetric time-domain window applied to the record. the number of data, and the statistics of the phase coupling among triads of modes. The theoretical results are verified by numerical simulations for simple test cases and applied to laboratory data to examine phase coupling in a hypothesis testing framework
Resumo:
Footwear is designed to reduce injury, and enhance performance. However, the effect footwear has on foot and ankle kinematics currently remains unknown. Acknowledging the need for improved understanding, multi-segment models of the foot-shoe complex need to be established to both describe and quantify the effect footwear has on the foot and ankle during stance phase of gait. The purpose of this study was to quantify how footwear alters the kinematics of the foot inside the shoe during stance phase of walking gait.
Resumo:
The privacy of efficient tree-based RFID authentication protocols is heavily dependent on the branching factor on the top layer. Indefinitely increasing the branching factor, however, is not a viable option. This paper proposes the alternate-tree walking scheme as well as two protocols to circumvent this problem. The privacy of the resulting protocols is shown to be comparable to that of linear-time protocols, where there is no leakage of information, whilst reducing the computational load of the database by one-third of what is required of tree-based protocols during authentication. We also identify and address a limitation in quantifying privacy in RFID protocols.
Resumo:
Introduction. Calculating segmental (vertebral level-by-level) torso masses in Adolescent Idiopathic Scoliosis (AIS) patients allows the gravitational loading on the scoliotic spine during relaxed standing to be determined. This study used CT scans of AIS patients to measure segmental torso masses and explores how joint moments in the coronal plane are affected by changes in the position of the intervertebral joint’s axis of rotation; particularly at the apex of a scoliotic major curve. Methods. Existing low dose CT data from the Paediatric Spine Research Group was used to calculate vertebral level-by-level torso masses and joint torques occurring in the spine for a group of 20 female AIS patients (mean age 15.0 ± 2.7 years, mean Cobb angle 53 ± 7.1°). Image processing software, ImageJ (v1.45 NIH USA) was used to threshold the T1 to L5 CT images and calculate the segmental torso volume and mass corresponding to each vertebral level. Body segment masses for the head, neck and arms were taken from published anthropometric data. Intervertebral (IV) joint torques at each vertebral level were found using principles of static equilibrium together with the segmental body mass data. Summing the torque contributions for each level above the required joint, allowed the cumulative joint torque at a particular level to be found. Since there is some uncertainty in the position of the coronal plane Instantaneous Axis of Rotation (IAR) for scoliosis patients, it was assumed the IAR was located in the centre of the IV disc. A sensitivity analysis was performed to see what effect the IAR had on the joint torques by moving it laterally 10mm in both directions. Results. The magnitude of the torso masses from T1-L5 increased inferiorly, with a 150% increase in mean segmental torso mass from 0.6kg at T1 to 1.5kg at L5. The magnitudes of the calculated coronal plane joint torques during relaxed standing were typically 5-7 Nm at the apex of the curve, with the highest apex joint torque of 7Nm being found in patient 13. Shifting the assumed IAR by 10mm towards the convexity of the spine, increased the joint torque at that level by a mean 9.0%, showing that calculated joint torques were moderately sensitive to the assumed IAR location. When the IAR midline position was moved 10mm away from the convexity of the spine, the joint torque reduced by a mean 8.9%. Conclusion. Coronal plane joint torques as high as 7Nm can occur during relaxed standing in scoliosis patients, which may help to explain the mechanics of AIS progression. This study provides new anthropometric reference data on vertebral level-by-level torso mass in AIS patients which will be useful for biomechanical models of scoliosis progression and treatment. However, the CT scans were performed in supine (no gravitational load on spine) and curve magnitudes are known to be smaller than those measured in standing.
Resumo:
Introduction: Calculating segmental (vertebral level-by-level) torso masses in Adolescent Idiopathic Scoliosis (AIS) patients allows the gravitational loading on the scoliotic spine during relaxed standing to be estimated. This study used supine CT scans of AIS patients to measure segmental torso masses and explored the joint moments in the coronal plane, particularly at the apex of a scoliotic major curve. Methods: Existing low dose CT data from the Paediatric Spine Research Group was used to calculate vertebral level-by-level torso masses and joint moments occurring in the spine for a group of 20 female AIS patients with right sided thoracic curves. The mean age was 15.0 ± 2.7 years and all curves were classified Lenke Type 1 with a mean Cobb angle 52 ± 5.9°. Image processing software, ImageJ (v1.45 NIH USA) was used to create reformatted coronal plane images, reconstruct vertebral level-by-level torso segments and subsequently measure the torso volume corresponding to each vertebral level. Segment mass was then determined by assuming a tissue density of 1.04x103 kg/m3. Body segment masses for the head, neck and arms were taken from published anthropometric data (Winter 2009). Intervertebral joint moments in the coronal plane at each vertebral level were found from the position of the centroid of the segment masses relative to the joint centres with the segmental body mass data. Results and Discussion: The magnitude of the torso masses from T1-L5 increased inferiorly, with a 150% increase in mean segmental torso mass from 0.6kg at T1 to 1.5kg at L5. The magnitudes of the calculated coronal plane joint moments during relaxed standing were typically 5-7 Nm at the apex of the curve, with the highest apex joint torque of 7Nm. The CT scans were performed in the supine position and curve magnitudes are known to be 7-10° smaller than those measured in standing, due to the absence of gravity acting on the spine. Hence, it can be expected that the moments produced by gravity in the standing individual will be greater than those calculated here.
Resumo:
Purpose Intensity modulated radiotherapy (IMRT) treatments require more beam-on time and produce more linac head leakage to deliver similar doses to conventional, unmodulated, radiotherapy treatments. It is necessary to take this increased leakage into account when evaluating the results of radiation surveys around bunkers that are, or will be, used for IMRT. The recommended procedure of 15 applying a monitor-unit based workload correction factor to secondary barrier survey measurements, to account for this increased leakage when evaluating radiation survey measurements around IMRT bunkers, can lead to potentially-costly over estimation of the required barrier thickness. This study aims to provide initial guidance on the validity of reducing the value of the correction factor when applied to different radiation barriers (primary barriers, doors, maze walls and other walls) by 20 evaluating three different bunker designs. Methods Radiation survey measurements of primary, scattered and leakage radiation were obtained at each of five survey points around each of three different radiotherapy bunkers and the contribution of leakage to the total measured radiation dose at each point was evaluated. Measurements at each survey point were made with the linac gantry set to 12 equidistant positions from 0 to 330o, to 25 assess the effects of radiation beam direction on the results. Results For all three bunker designs, less than 0.5% of dose measured at and alongside the primary barriers, less than 25% of the dose measured outside the bunker doors and up to 100% of the dose measured outside other secondary barriers was found to be caused by linac head leakage. Conclusions Results of this study suggest that IMRT workload corrections are unnecessary, for 30 survey measurements made at and alongside primary barriers. Use of reduced IMRT workload correction factors is recommended when evaluating survey measurements around a bunker door, provided that a subset of the measurements used in this study are repeated for the bunker in question. Reduction of the correction factor for other secondary barrier survey measurements is not recommended unless the contribution from leakage is separetely evaluated.
Resumo:
The relationship between coronal knee laxity and the restraining properties of the collateral ligaments remains unknown. This study investigated correlations between the structural properties of the collateral ligaments and stress angles used in computer-assisted total knee arthroplasty (TKA), measured with an optically based navigation system. Ten fresh-frozen cadaveric knees (mean age: 81 ± 11 years) were dissected to leave the menisci, cruciate ligaments, posterior joint capsule and collateral ligaments. The resected femur and tibia were rigidly secured within a test system which permitted kinematic registration of the knee using a commercially available image-free navigation system. Frontal plane knee alignment and varus-valgus stress angles were acquired. The force applied during varus-valgus testing was quantified. Medial and lateral bone-collateral ligament-bone specimens were then prepared, mounted within a uni-axial materials testing machine, and extended to failure. Force and displacement data were used to calculate the principal structural properties of the ligaments. The mean varus laxity was 4 ± 1° and the mean valgus laxity was 4 ± 2°. The corresponding mean manual force applied was 10 ± 3 N and 11 ± 4 N, respectively. While measures of knee laxity were independent of the ultimate tensile strength and stiffness of the collateral ligaments, there was a significant correlation between the force applied during stress testing and the instantaneous stiffness of the medial (r = 0.91, p = 0.001) and lateral (r = 0.68, p = 0.04) collateral ligaments. These findings suggest that clinicians may perceive a rate of change of ligament stiffness as the end-point during assessment of collateral knee laxity.