999 resultados para Cooling methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to optimize the machining of Ti-6Al-4V alloy, by studying the chip formation, roughness and tool wear for different cooling conditions. The results were compared between cooling methods, minimal quantity of fluid (MQF) and flooding, and also without fluid for the tool H13A. The turning of Ti-6Al-4V has shown good results on roughness (0, 8μm) and tool life, which was 11% lower with MQF than with the flooding method. The tool wear causes variation of the shear angle, which promotes strength hardening of the chip. As a result, the machined surface could be damaged. The use of the cutting fluid helps to save the cutting edge and could reduce the strength hardening. Nevertheless, it could also facilitate the formation of built-up edge. The nucleation of alpha lamellar colonies can occur due to a combination of deformation rates and temperature, mainly when the flooding is used, but it's not conclusive. The lamellar colonies were also found with the MQF in some regions, however, this structure did not show hardness variation compared to equiaxial. For all this reasons, the machining parameters might be carefully chosen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study investigated the effect of extreme cooling methods on the flexural strength, reliability and shear bond strength of veneer porcelain for zirconia. Methods: Vita VM9 porcelain was sintered on zirconia bar specimens and cooled by one of the following methods: inside a switched-off furnace (slow), at room temperature (normal) or immediately by compressed air (fast). Three-point flexural strength tests (FS) were performed on specimens with porcelain under tension (PT, n = 30) and zirconia under tension (ZT, n = 30). Shear bond strength tests (SBS, n = 15) were performed on cylindrical blocks of porcelain, which were applied on zirconia plates. Data were submitted to one-way ANOVA and Tukey's post hoc tests (p < 0.05). Weibull analysis was performed on the PT and ZT configurations. Results: One-way ANOVA for the PT configuration was significant, and Tukey's test revealed that fast cooling leads to significantly higher values (p < 0.01) than the other cooling methods. One-way ANOVA for the ZT configuration was not significant (p = 0.06). Weibull analysis showed that normal cooling had slightly higher reliability for both the PT and ZT configurations. Statistical tests showed that slow cooling decreased the SBS value (p < 0.01) and showed less adhesive fracture modes than the other cooling methods. Clinical Significance: Slow cooling seems to affect the veneer resistance and adhesion to the zirconia core; however, the reliability of fast cooling was slightly lower than that of the other methods. © 2013 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Therapeutic hypothermia following hypoxic ischaemic encephalopathy in term infants was introduced into Switzerland in 2005. Initial documentation of perinatal and resuscitation details was poor and neuromonitoring insufficient. In 2011, a National Asphyxia and Cooling Register was introduced. AIMS: To compare management of cooled infants before and after introduction of the register concerning documentation, neuromonitoring, cooling methods and evaluation of temperature variability between cooling methods. STUDY DESIGN: Data of cooled infants before the register was in place (first time period: 2005-2010) and afterwards (second time period: 2011-2012) was collected with a case report form. RESULTS: 150 infants were cooled during the first time period and 97 during the second time period. Most infants were cooled passively or passively with gel packs during both time periods (82% in 2005-2010 vs 70% in 2011-2012), however more infants were cooled actively during the second time period (18% versus 30%). Overall there was a significant reduction in temperature variability (p < 0.001) comparing the two time periods. A significantly higher proportion of temperature measurements within target temperature range (72% versus 77%, p < 0.001), fewer temperature measurements above (24% versus 7%, p < 0.001) and more temperatures below target range (4% versus 16%, p < 0.001) were recorded during the second time period. Neuromonitoring improved after introduction of the cooling register. CONCLUSION: Management of infants with HIE improved since introducing the register. Temperature variability was reduced, more temperature measurements in the target range and fewer temperature measurements above target range were observed. Neuromonitoring has improved, however imaging should be performed more often.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Today’s electrical machine technology allows increasing the wind turbine output power by an order of magnitude from the technology that existed only ten years ago. However, it is sometimes argued that high-power direct-drive wind turbine generators will prove to be of limited practical importance because of their relatively large size and weight. The limited space for the generator in a wind turbine application together with the growing use of wind energy pose a challenge for the design engineers who are trying to increase torque without making the generator larger. When it comes to high torque density, the limiting factor in every electrical machine is heat, and if the electrical machine parts exceed their maximum allowable continuous operating temperature, even for a short time, they can suffer permanent damage. Therefore, highly efficient thermal design or cooling methods is needed. One of the promising solutions to enhance heat transfer performances of high-power, low-speed electrical machines is the direct cooling of the windings. This doctoral dissertation proposes a rotor-surface-magnet synchronous generator with a fractional slot nonoverlapping stator winding made of hollow conductors, through which liquid coolant can be passed directly during the application of current in order to increase the convective heat transfer capabilities and reduce the generator mass. This doctoral dissertation focuses on the electromagnetic design of a liquid-cooled direct-drive permanent-magnet synchronous generator (LC DD-PMSG) for a directdrive wind turbine application. The analytical calculation of the magnetic field distribution is carried out with the ambition of fast and accurate predicting of the main dimensions of the machine and especially the thickness of the permanent magnets; the generator electromagnetic parameters as well as the design optimization. The focus is on the generator design with a fractional slot non-overlapping winding placed into open stator slots. This is an a priori selection to guarantee easy manufacturing of the LC winding. A thermal analysis of the LC DD-PMSG based on a lumped parameter thermal model takes place with the ambition of evaluating the generator thermal performance. The thermal model was adapted to take into account the uneven copper loss distribution resulting from the skin effect as well as the effect of temperature on the copper winding resistance and the thermophysical properties of the coolant. The developed lumpedparameter thermal model and the analytical calculation of the magnetic field distribution can both be integrated with the presented algorithm to optimize an LC DD-PMSG design. Based on an instrumented small prototype with liquid-cooled tooth-coils, the following targets have been achieved: experimental determination of the performance of the direct liquid cooling of the stator winding and validating the temperatures predicted by an analytical thermal model; proving the feasibility of manufacturing the liquid-cooled tooth-coil winding; moreover, demonstration of the objectives of the project to potential customers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Therapeutic hypothermia following hypoxic ischaemic encephalopathy in term infants was introduced into Switzerland in 2005. Initial documentation of perinatal and resuscitation details was poor and neuromonitoring insufficient. In 2011, a National Asphyxia and Cooling Register was introduced. AIMS To compare management of cooled infants before and after introduction of the register concerning documentation, neuromonitoring, cooling methods and evaluation of temperature variability between cooling methods. STUDY DESIGN Data of cooled infants before the register was in place (first time period: 2005-2010) and afterwards (second time period: 2011-2012) was collected with a case report form. RESULTS 150 infants were cooled during the first time period and 97 during the second time period. Most infants were cooled passively or passively with gel packs during both time periods (82% in 2005-2010 vs 70% in 2011-2012), however more infants were cooled actively during the second time period (18% versus 30%). Overall there was a significant reduction in temperature variability (p < 0.001) comparing the two time periods. A significantly higher proportion of temperature measurements within target temperature range (72% versus 77%, p < 0.001), fewer temperature measurements above (24% versus 7%, p < 0.001) and more temperatures below target range (4% versus 16%, p < 0.001) were recorded during the second time period. Neuromonitoring improved after introduction of the cooling register. CONCLUSION Management of infants with HIE improved since introducing the register. Temperature variability was reduced, more temperature measurements in the target range and fewer temperature measurements above target range were observed. Neuromonitoring has improved, however imaging should be performed more often.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Elektroniikan pienentyessä ja tehotiheyden kasvaessa tarvitaan paremmin suunniteltuja jäähdytysjärjestelyjä. Suunnittelun apuna voidaan käyttää perinteisiä lämmönsiirtoyhtälöitä, virtauslaskentaa ja mittauksia. Tässä työssä on suunniteltu ja rakennettu mittauslaitteisto nimenomaan elektroniikan komponenttien ja jäähdytyselementtien lämpötilojen ja painehäviöiden mittaamiseen. Koeajona laitteistolla on mitattu jäähdytyselementin lämpötilajakauma kahdella eri virtausnopeudella ja lämpötilalla sekä verrattu niitä aikaisemmin mitattuihin tapauksiin sekä Fluent- virtauslaskentaohjelmalla laskettuihin tuloksiin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tämä diplomityö on osa Lappeenrannan teknillisen yliopiston ja Visedo Oy:n yhteistyöprojektia. Työssä selvitetään pyörivien sähkökoneiden kotelointeja koskevia standardeja ja niiden vaikutukset koneiden suunnittelulle ja valmistukselle. Lisäksi työssä käsitellään aksiaalivuokoneen jäähdytykseen liittyviä ongelmia, kehitetään koneen nykyisiä jäähdytysratkaisuja ja ideoidaan käytettävissä olevia uusia jäähdytysmenetelmiä. Kehitysideoiden rajoitteena toimii koneelta vaadittu kotelointiluokka IP 64 – IP 68 sekä koneelle määritetty kestomagnetoitu aksiaalivuorakenne. Sähkökoneiden kotelointeja koskevien standardien asettamien vaatimusten määrittäminen tapahtui suurilta osin kirjallisuusselvityksenä. Standardien vaikutukset koneiden suunnittelulle ja valmistettavuudelle on selvitetty standardien kotelointien rakenteelle asettamien vaatimusten perusteella. Aksiaalivuokoneen jäähdytysongelmien selvittäminen, käytössä olevien jääh-dytysratkaisujen kehittäminen ja uusien menetelmien ideointi suoritettiin projektiluontoisesti yhdessä eri alojen asiantuntijoista koostuvan jäähdytystyöryhmän kanssa. Työn tuloksena laadittiin Visedo Oy:lle standardikäsikirja, jonka avulla Visedon sähkökoneiden tuoteperheeseen kuuluvien koneiden suunnitteluvaiheessa voidaan varmistaa koneiden standardienmukaisuus. Käsikirjassa on myös esitetty huomioita eri kotelointiluokkien asettamista vaatimuksista koneiden valmistukselle. Aksiaalivuokoneiden jäähdytykseen liittyen tavoitteena oli ratkaista aksiaalivuokoneisiin liittyviä jäähdytysongelmia. Työn tuloksena saa-tiin selville aksiaalivuokoneissa jäähdytyksen kehittämistä vaativat kohteet, laadittiin nykyisten jäähdytysratkaisujen parannusehdotuksia ja kehitettiin täysin uusia jäähdytysmenetelmiä.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena on selvittää mahdollisuutta hyödyntää lunta tilojen jäähdytykseen Koneen Hyvinkään tehdasalueella. Työssä kerrotaan myös yleisesti eri jäähdytysmuodoista ja tuotantotavoista. Eri kirjallisuuslähteiden pohjalta tutkittiin erilaisia lumijäähdytysjärjestelmiä, joiden energiataseiden pohjalta tehtiin sopiva malli kohdealueelle. Mallin avulla selvitettiin lumesta hyödynnettävä jäähdytysenergian määrä. Esitetylle varastolle hahmoteltiin investointi- ja käyttökustannukset kirjallisuuslähteiden ja asiantuntijoiden avulla. Kustannuksien ja jäähdytysenergiamäärien avulla laskettiin lumijäähdytyksen tuotantokustannukset, joita verrattiin perinteiseen kompressorijäähdyttimeen. Lopuksi pohdittiin vielä takaisinmaksuaikoja lumivaraston liittyessä nykyisiin jäähdytysjärjestelmiin ja kokonaan uuteen jäähdytysverkostoon. Tuloksien mukaan lumijäähdytys ei ole taloudellisesti kannattavaa Koneen Hyvinkään tehdasalueella. Ongelmaksi muodostui investointikustannusten suuruus verrattuna saatuihin säästöihin. Ympäristöllisesti ja yrityksellisesti hanketta voidaan pitää kannattavana. Lumijäähdytyksestä voidaan saada kannattavampi suuremmilla lumimäärillä, mikä vaatisi myös suuremmat jäähdytysenergiankulutukset kuin Koneella on. Myös hyödyntämällä luonnon omia rakenteita voidaan parantaa kannattavuutta.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the present study was to precool cauliflower using forced-air, vacuum and high and low flow hydro cooling methods. The weight of the precooled cauliflower heads (5000±5 g) was measured before they were placed in standard plastic crates. Cauliflower heads, whose initial temperature was 23.5 ± 0.5 ºC, were cooled until the temperature reached at 1 ºC. During the precooling process, time-dependent temperature and energy consumption were measured, and during vacuum precooling, the decreasing pressure values were recorded, and a curve of time-dependent pressure decrease (vacuum) was built. The most suitable cooling method to precool cauliflower in terms of cooling time and energy consumption was vacuum, followed by the high and low flow hydro and forced-air precooling methods, respectively. The highest weight loss was observed in the vacuum precooling method, followed by the forced-air method. However, there was an increase in the weight of the cauliflower heads in the high and low flow hydro precooling method. The best colour and hardness values were found in the vacuum precooling method. Among all methods tested, the most suitable method to precool cauliflower in terms of cooling and quality parameters was the vacuum precooling method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC