988 resultados para Converter analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The combination of minimum time control and multiphase converter is a favorable option for dc-dc converters in applications where output voltage variation is required, such as RF amplifiers and dynamic voltage scaling in microprocessors, due to their advantage of fast dynamic response. In this paper, an improved minimum time control approach for multiphase buck converter that is based on charge balance technique, aiming at fast output voltage transition is presented. Compared with the traditional method, the proposed control takes into account the phase delay and current ripple in each phase. Therefore, by investigating the behavior of multiphase converter during voltage transition, it resolves the problem of current unbalance after the transient, which can lead to long settling time of the output voltage. The restriction of this control is that the output voltage that the converter can provide is related to the number of the phases, because only the duty cycles at which the multiphase converter has total ripple cancellation are used in this approach. The model of the proposed control is introduced, and the design constraints of the buck converters filter for this control are discussed. In order to prove the concept, a four-phase buck converter is implemented and the experimental results that validate the proposed control method are presented. The application of this control to RF envelope tracking is also presented in this paper.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho apresenta o estudo comparativo do desempenho de três topologias de conversores do sistema monofásico para o sistema trifásico com número reduzido de componentes, para o acionamento de um motor de indução do tipo rotor gaiola de esquilo. O funcionamento de cada topologia é descrito e simulado digitalmente. O desempenho desses conversores é avaliado em diferentes modos de operação, com sequência de fase positiva ou negativa, com ênfase na qualidade de energia em termos de redução da distorção harmônica total e da melhoria do fator de potência na fonte. Com vistas à redução de custos, foi desenvolvido um protótipo experimental baseado no uso de módulo integrado de chaves semicondutoras de potência e de um microcontrolador de baixo custo. Os resultados experimentais se equiparam aos resultados obtidos por simulação.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the stability of an autonomous microgrid with multiple distributed generators (DG) is studied through eigenvalue analysis. It is assumed that all the DGs are connected through Voltage Source Converter (VSC) and all connected loads are passive. The VSCs are controlled by state feedback controller to achieve desired voltage and current outputs that are decided by a droop controller. The state space models of each of the converters with its associated feedback are derived. These are then connected with the state space models of the droop, network and loads to form a homogeneous model, through which the eigenvalues are evaluated. The system stability is then investigated as a function of the droop controller real and reac-tive power coefficients. These observations are then verified through simulation studies using PSCAD/EMTDC. It will be shown that the simulation results closely agree with stability be-havior predicted by the eigenvalue analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper analyses the performance of particular wave-energy converter that uses the gyroscopic effects of a large rotating fly-wheel in combination with a controlled power-take-off device. Controlled gyroscopic forces have been used successfully in the past to reduce the motion of marine structures. With appropriately designed power-take-off elements, gyroscopic forces can be controlled to optimise the extracted energy from the motion of marine structures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper deals with the system oriented analysis, design, modeling, and implementation of active clamp HF link three phase converter. The main advantage of the topology is reduced size, weight, and cost of the isolation transformer. However, violation of basic power conversion rules due to presence of the leakage inductance in the HF transformer causes over voltage stresses across the cycloconverter devices. It makes use of the snubber circuit necessary in such topologies. The conventional RCD snubbers are dissipative in nature and hence inefficient. The efficiency of the system is greatly improved by using regenerative snubber or active clamp circuit. It consists of an active switching device with an anti-parallel diode and one capacitor to absorb the energy stored in the leakage inductance of the isolation transformer and to regenerate the same without affecting circuit performance. The turn on instant and duration of the active device are selected such that it requires simple commutation requirements. The time domain expressions for circuit dynamics, design criteria of the snubber capacitor with two conflicting constrains (over voltage stress across the devices and the resonating current duration), the simulation results based on generalized circuit model and the experimental results based on laboratory prototype are presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A 5V/1 V Switched Capacitor (SC) dc-dc converter designed for a 0.18μm CMOS process is analysed in detail, in this paper. Analytical equations are derived for the voltages and currents through the main components of the SC converter. The model includes switches, capacitors, equivalent series resistances and the load. The switches in the converter are represented by MOSFETs in the UMC 0.18μm CMOS process. The impact of system parameters on output voltage ripple are studied using the analytical expressions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Submitted by 阎军 (yanj@red.semi.ac.cn) on 2010-06-04T08:02:20Z No. of bitstreams: 1 Design and Simulation Analysis of Spot-Size Converter in Silicon-On-Insulator.pdf: 239163 bytes, checksum: 82db1386c266d0c07442a972348da08c (MD5)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

DC line faults on high-voltage direct current (HVDC) systems utilising voltage source converters (VSCs) are a major issue for multi-terminal HVDC systems in which complete isolation of the faulted system is not a viable option. Of these faults, single line-to-earth faults are the most common fault scenario. To better understand the system under such faults, this study analyses the behaviour of HVDC systems based on both conventional two-level converter and multilevel modular converter technology, experiencing a permanent line-to-earth fault. Operation of the proposed system under two different earthing configurations of converter side AC transformer earthed with converter unearthed, and both converter and AC transformer unearthed, was analysed and simulated, with particular attention paid to the converter operation. It was observed that the development of potential earth loops within the system as a result of DC line-to-earth faults leads to substantial overcurrent and results in oscillations depending on the earthing configuration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

During extreme sea states so called impact events can be observed on the wave energy converter Oyster. In small scale experimental tests these impact events cause high frequency signals in the measured load which decrease confidence in the data obtained. These loads depend on the structural dynamics of the model. Amplification of the loads can occur and is transferred through the structure from the point of impact to the load cell located in the foundation. Since the determination of design data and load cases for Wave Energy Converters originate from scale experiments, this lack of confidence has a direct effect on the development.

Numerical vibration analysis is a valuable tool in the research of the structural load response of Oyster to impact events, but must take into account the effect of the surrounding water. This can be done efficiently by adding an added mass distribution, computed with a linearised potential boundary element method. This paper presents the development and validation of a numerical procedure, which couples the OpenSource boundary element code NEMOH with the Finite Element Analysis tool CodeAster. Numerical results of the natural frequencies and mode shapes of the structure under the influence of added mass due to specific structural modes are compared with experimental results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents an in-depth critical discussion and derivation of a detailed small-signal analysis of the Phase-Shifted Full-Bridge (PSFB) converter. Circuit parasitics, resonant inductance and transformer turns ratio have all been taken into account in the evaluation of this topology’s open-loop control-to-output, line-to-output and load-to-output transfer functions. Accordingly, the significant impact of losses and resonant inductance on the converter’s transfer functions is highlighted. The enhanced dynamic model proposed in this paper enables the correct design of the converter compensator, including the effect of parasitics on the dynamic behavior of the PSFB converter. Detailed experimental results for a real-life 36V-to-14V/10A PSFB industrial application show excellent agreement with the predictions from the model proposed herein.1

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents an efficiency investigation of an isolated high step-up ratio dc-dc converter aimed to be used for energy processing from low-voltage high-current energy sources, like batteries, photovoltaic modules or fuel-cells. The considered converter consists of an interleaved active clamp flyback topology combined with a voltage multiplier at the transformer secondary side capable of two different operating modes, i.e. resonant and non-resonant according to the design of the output capacitors. The main goal of this paper is to compare these two operating modes from the component losses point of view with the aim of maximize the overall converter efficiency. The approach is based on losses prediction using steady-state theoretical models (designed in Mathcad environment), taking into account both conduction and switching losses. The models are compared with steady-state simulations and experimental results considering different operating modes to validate the approach. © 2012 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper a novel bidirectional multiple port dc/dc transformer topology is presented. The novel concept for dc/dc transformer is based on the Series Resonant Converter (SRC) topology operated at its resonant frequency point. This allows for higher switching frequency to be adopted and enables high efficiency/high power density operation. The feasibility of the proposed concept is verified on a 300W, 700 kHz three port prototype with 390V input voltage and 48V and 12V output voltages. A peak overall efficiency of 93% is measured at full load. A very good load and cross regulation characteristic of the converter is observed in the whole load range, from full load to open circuit. The sensitivity analysis of the resonant capacitance is also performed showing very slight deterioration in the converter performances when a resonant capacitor is changed ±30% of its nominal value.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

V2Ic control provides very fast dynamic performance to the Buck converter both under load steps and under voltage reference steps. However, the design of this control is complex since it is prone to subharmonic oscillations and several parameters affect the stability of the system. This paper derives and validates a very accurate modeling and stability analysis of a closed-loop V2Ic control using the Floquet theory. This allows the derivation of sensitivity analysis to design a robust converter. The proposed methodology is validated on a 5-MHz Buck converter. The work is also extended to V2 control using the same methodology, showing high accuracy and robustness. The paper also demonstrates, on the V2 control, that even a low bandwidth-linear controller can affect the stability of a ripple-based control.