991 resultados para Controlador PI


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, the variable structure adaptive pole placement controller (VS-APPC) robustness and performance are evaluated and this algorithm is applied in a motor control system. The controller robustness evaluation will be done through simulations, where will be introduced in the system the following adversities: time delay, actuator response boundeds, disturbances, parametric variation and unmodeled dynamics. The VS-APPC will be compared with PI control, pole placement control (PPC) and adaptive pole placement controller (APPC). The VS-APPC will be simulated to track a step and a sine reference. It will be applied in a three-phase induction motor control system to track a sine signal in the stator reference frame. Simulation and experimental results will prove the efficiency and robustness of this control strategy

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Este trabalho investiga uma estratégia de controle fuzzy Takagi-Sugeno aplicada ao controle de velocidade do motor de indução. A estratégia implementa uma interpolação ponderada entre um conjunto de controladores locais previamente projetados. Ao ocorrer variações nas condições operacionais do motor de indução, os ganhos da lei de controle são ajustados automaticamente, de modo a manter satisfatório o desempenho do sistema de controle. Para o projeto do controlador fuzzy a representação em espaço de estados da planta foi considerada sob a forma de um sistema aumentado, incluindo-se uma nova variável de estado que, nesse caso, foi selecionada como sendo a integral do erro de velocidade. Tal formulação permitiu o projeto de controladores locais com a estrutura PI, através de realimentação completa de estados, com posicionamento de pólos. Como variáveis de operação para o chaveamento fuzzy dos controladores locais, foram selecionados as variáveis velocidade angular do rotor e a componente da corrente de estator responsável pelo torque elétrico do motor. Em seguida, a estabilidade do controlador fuzzy Takagi- Sugeno projetado foi comprovada através do critério de Lyapunov, para isso o problema de estabilidade foi escrito na forma de LMIs. O desempenho do controlador fuzzy Takagi-Sugeno foi avaliado através de estudos de simulação, e seus resultados comparados ao desempenho de um controlador PI convencional, para a regulação da velocidade do rotor. Os resultados obtidos nas simulações mostram que o emprego da estratégia proposta torna o sistema mais robusto a variações paramétricas no sistema de acionamento.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Este trabalho estuda a técnica de acionamento vetorial aplicado ao motor de indução trifásico (MIT), utilizando como estratégia de controle a combinação de controle fuzzy com controladores chaveados do tipo modo deslizante, em uma configuração aqui denominada de Controlador Fuzzy Modo Deslizante (FSMC – Do inglês: Fuzzy Sliding Mode Control). Um modelo dinâmico do MIT é desenvolvido em variáveis ‘d-q’ o que conduziu a um modelo eletromecânico em espaço de estados que exibe fortes não linearidades. A este modelo são aplicadas as condições de controle vetorial que permitem desacoplar o torque e o fluxo no MIT, de maneira que o seu comportamento dinâmico se assemelha àquele verificado em uma máquina de corrente contínua. Nesta condição, são implementados controladores do tipo proporcional e integral (PI) às malhas de controle de corrente e velocidade do motor, e são realizadas simulações computacionais para o rastreamento de velocidade e perturbação de carga, o que levam a resultados satisfatórios do ponto de vista dinâmico. Visando investigar o desempenho das estratégias não lineares nesta abordagem é apresentado o estudo da técnica de controle a estrutura chaveada do tipo modo deslizante. Um controlador modo deslizante convencional é implementado, onde se verifica que, a despeito do excelente desempenho dinâmico a ocorrência do fenômeno do “chettering” inviabiliza a aplicação desta estratégia em testes reais. Assim, é proposta a estratégia de controle FSMC, buscando associar o bom resultado dinâmico obtido com o controlador modo deslizante e a supressão do fenômeno do chettering, o que se atinge pela definição de uma camada de chaveamento do tipo Fuzzy. O controlador FSMC proposto é submetido aos mesmos testes computacionais que o controlador PI, conduzindo a resultados superiores a este último no transitório da resposta dinâmica, porém com a presença de erro em regime permanente. Para atacar este problema é implementada uma combinação Fuzzy das estratégias FSMC com a ação de controle PI, onde o primeiro busca atuar em regiões afastadas da superfície de chaveamento e o segundo busca introduzir o efeito da ação integral próximo à superfície. Os resultados obtidos mostram a viabilidade da estratégia em acionamento de velocidade variável que exigem elevado desempenho dinâmico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Eletrotécnica Ramo de Automação e Eletrónica Industrial

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Eletrotécnica e de Computadores

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El control de las centrales hidroeléctricas ha venido siendo motivo continuo de estudio. Más aún en el caso de centrales que proporcionan la energía a Islas donde se intenta sustituir la generación térmica por la convivencia de los parques eólicos y una central hidroeléctrica, puesto que el control es fundamental para el correcto funcionamiento del sistema. Varios son los trabajos que se han desarrollado en esta materia hasta la fecha pero no se han prodigado en analizar la influencia que la longitud de las conducciones forzadas tiene en el ajuste del controlador. El objetivo principal de este estudio es desarrollar unas recomendaciones relativas al ajuste de los reguladores de velocidad de los grupos hidroeléctricos en sistemas aislados con conducciones de gran longitud, aportando así valores alternativos a los propuestos por otros autores; entre otras razones porque éstos estudiaban centrales cuyas conducciones no exigían el análisis de la elasticidad de la conducción y del fluido. Dichas recomendaciones están basadas en la oportuna ubicación de los polos que representan la respuesta dinámica de los principales componentes de la central. Así, encontramos los valores de las ganancias del controlador PI que mejoran la respuesta de la central dado que la longitud de la tubería forzada es lo suficientemente grande como para que sea preciso incluir su efecto en el ajuste. Para tener en cuenta la compresibilidad del agua y de la tubería se ha empleado el modelo de parámetros concentrados. Dicho modelo se simplifica y se linealiza para su estudio, mientras que el ajuste propuesto es aplicado al modelo no lineal original.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Eletrotécnica Ramo de Automação e Eletrónica Industrial

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El control automàtic exerceix un paper important en molts processos de la industria. Cada un dels sistemes de control requereix d’un controlador, la majoria dels quals són del tipus PI. L’objectiu d’aquest projecte es investigar tècniques que permetin superar les limitacions que tenen els controladors PI lineals. En la resposta d’un sistema de control es poden distingir dues tasques diferents: El seguiment a un canvi d’entrada o consigna correspon a la tasca de servo, mentre que el rebuig a pertorbacions correspon a la tasca de regulatori. Al típic esquema de control realimentat, aquestes dues tasques estan enfrontades, és a dir, una millora a la tasca de servo implica un empitjorament a la tasca de regulatori i a l’inversa. Això suposa un problema al rendiment del sistema, així com la necessitat d’establir un cert compromís entre les dues tasques. El que es pretén en aquest projecte es implementar senzilles regles de control no lineal amb la finalitat de millorar el rendiment del sistema i evitar la necessitat d’establir un compromís entre les dues tasques. Així, es pretén superar les limitacions que aquest té, obtenint controladors PI alternatius fàcilment sintetitzables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On this paper, it is made a comparative analysis among a controller fuzzy coupled to a PID neural adjusted by an AGwith several traditional control techniques, all of them applied in a system of tanks (I model of 2nd order non lineal). With the objective of making possible the techniques involved in the comparative analysis and to validate the control to be compared, simulations were accomplished of some control techniques (conventional PID adjusted by GA, Neural PID (PIDN) adjusted by GA, Fuzzy PI, two Fuzzy attached to a PID Neural adjusted by GA and Fuzzy MISO (3 inputs) attached to a PIDN adjusted by GA) to have some comparative effects with the considered controller. After doing, all the tests, some control structures were elected from all the tested techniques on the simulating stage (conventional PID adjusted by GA, Fuzzy PI, two Fuzzy attached to a PIDN adjusted by GA and Fuzzy MISO (3 inputs) attached to a PIDN adjusted by GA), to be implemented at the real system of tanks. These two kinds of operation, both the simulated and the real, were very important to achieve a solid basement in order to establish the comparisons and the possible validations show by the results

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last decade, the renewable energy sources have present a major propulsion in the world due to several factors: political, environmental, financial and others. Within this context, we have in particular the energy obtained through wind, wind energy - that has highlighted with rapid growth in recent years, including in Brazil, mostly in the Northeast, due to it s benefit-cost between the clean energies. In this context, we propose to compare the variable structure adaptive pole placement control (VS-APPC) with a traditional control technique proportional integral controller (PI), applied to set the control of machine side in a conversion system using a wind generator based on Double-Fed Induction Generator (DFIG). Robustness and performance tests were carried out to the uncertainties of the internal parameters of the machine and variations of speed reference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La tendencia actual de las redes de telecomunicaciones conduce a pensar en un futuro basado en el concepto emergente de las Smart Cities¸ que tienen como objetivo el desarrollo urbano basado en un modelo de sostenibilidad que responda a las necesidades crecientes de las ciudades. Dentro de las Smart Cities podemos incluir el concepto de Smart Grid, el cual está referido a sistemas de administración y producción de energía eficientes, que permitan un sistema energético sostenible, y que den cabida a las fuentes de energía renovables. Sistemas de este tipo se muestran a los usuarios como un conjunto de servicios con los que interactuar sin ser tan sólo un mero cliente, sino un agente más del entorno energético. Por otro lado, los sistemas de software distribuidos son cada vez más comunes en una infraestructura de telecomunicaciones cada vez más extensa y con más capacidades. Dentro de este ámbito tecnológico, las arquitecturas orientadas a servicios han crecido exponencialmente sobre todo en el sector empresarial. Con sistemas basados en estas arquitecturas, se pueden ofrecer a empresas y usuarios sistemas software basados en el concepto de servicio. Con la progresión del hardware actual, la miniaturización de los equipos es cada vez mayor, sin renunciar por ello a la potencia que podemos encontrar en sistemas de mayor tamaño. Un ejemplo es el dispositivo Raspberry Pi, que contiene un ordenador plenamente funcional contenido en el tamaño de una cajetilla de tabaco, y con un coste muy reducido. En este proyecto se pretenden aunar los tres conceptos expuestos. De esta forma, se busca utilizar el dispositivo Raspberry Pi como elemento de despliegue integrado en una arquitectura de Smart Grid orientada a servicios. En los trabajos realizados se ha utilizado la propuesta definida por el proyecto de I+D europeo e-GOTHAM, con cuya infraestructura se ha tenido ocasión de realizar diferentes pruebas de las descritas en esta memoria. Aunque esta arquitectura está orientada a la creación de una Smart Grid, lo experimentado en este PFG podría encajar en otro tipo de aplicaciones. Dentro del estudio sobre las soluciones software actuales, se ha trabajado en la evaluación de la posibilidad de instalar un Enterprise Service Bus en el Raspberry Pi y en la optimización de la citada instalación. Una vez conseguida una instalación operativa, se ha desarrollado un controlador de un dispositivo físico (sensor/actuador), denominado Dispositivo Lógico, a modo de prueba de la viabilidad del uso del Raspberry Pi para actuar como elemento en el que instalar aplicaciones en entornos de Smart Grid o Smart Home. El éxito logrado con esta experimentación refuerza la idea de considerar al Raspberry Pi, como un importante elemento a tener en cuenta para el despliegue de servicios de Smart Cities o incluso en otros ámbitos tecnológicos. ABSTRACT. The current trend of telecommunication networks lead to think in a future based on the emerging concept of Smart Cities, whose objective is to ensure the urban development based on a sustainable model to respond the new necessities of the cities. Within the Smart cites we can include the concept of Smart Grid, which is based on management systems and efficient energy production, allowing a sustainable energy producing system, and that includes renewable energy sources. Systems of this type are shown to users as a set of services that allow users to interact with the system not only as a single customer, but also as other energy environment agent. Furthermore, distributed software systems are increasingly common in a telecommunications infrastructure more extensive and with more capabilities. Within this area of technology, service-oriented architectures have grown exponentially especially in the business sector. With systems based on these architectures, can be offered to businesses and users software systems based on the concept of service. With the progression of the actual hardware, the miniaturization of computers is increasing, without sacrificing the power of larger systems. An example is the Raspberry Pi, which contains a fully functional computer contained in the size of a pack of cigarettes, and with a very low cost. This PFG (Proyecto Fin de Grado) tries to combine the three concepts presented. Thus, it is intended to use the Raspberry Pi device as a deployment element integrated into a service oriented Smart Grid architecture. In this PFG, the one proposed in the European R&D e-GOTHAM project has been observed. In addition several tests described herein have been carried out using the infrastructure of that project. Although this architecture is oriented to the creation of a Smart Grid, the experiences reported in this document could fit into other applications. Within the study on current software solutions, it have been working on assessing the possibility of installing an Enterprise Service Bus in the Raspberry Pi and optimizing that facility. Having achieved an operating installation, it has been developed a driver for a physical device (sensor / actuator), called logical device, for testing the feasibility of using the Raspberry Pi to act as an element in which to install applications in Smart Grid and Smart Home Environments. The success of this experiment reinforces the idea of considering the Raspberry Pi as an important element to take into account in the deployment of Smart Cities services or even in other technological fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanism of incoherent pi(0) and eta photoproduction from complex nuclei is investigated from 4 to 12 GeV with an extended version of the multicollisional Monte Carlo (MCMC) intranuclear cascade model. The calculations take into account the elementary photoproduction amplitudes via a Regge model and the nuclear effects of photon shadowing, Pauli blocking, and meson-nucleus final-state interactions. The results for pi(0) photoproduction reproduced for the first time the magnitude and energy dependence of the measured rations sigma(gamma A)/sigma(gamma N) for several nuclei (Be, C, Al, Cu, Ag, and Pb) from a Cornell experiment. The results for eta photoproduction fitted the inelastic background in Cornell's yields remarkably well, which is clearly not isotropic as previously considered in Cornell's analysis. With this constraint for the background, the eta -> gamma gamma. decay width was extracted using the Primakoff method, combining Be and Cu data [Gamma(eta ->gamma gamma) = 0.476(62) keV] and using Be data only [Gamma(eta ->gamma gamma) = 0.512(90) keV]; where the errors are only statistical. These results are in sharp contrast (similar to 50-60%) with the value reported by the Cornell group [Gamma(eta ->gamma gamma). = 0.324(46) keV] and in line with the Particle Data Group average of 0.510(26) keV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a sample of 68.3x10(6) K(L)->pi(0)pi(0)pi(0) decays collected in 1996-1999 by the KTeV (E832) experiment at Fermilab, we present a detailed study of the K(L)->pi(0)pi(0)pi(0) Dalitz plot density. We report the first observation of interference from K(L)->pi(+)pi(-)pi(0) decays in which pi(+)pi(-) rescatters to pi(0)pi(0) in a final-state interaction. This rescattering effect is described by the Cabibbo-Isidori model, and it depends on the difference in pion scattering lengths between the isospin I=0 and I=2 states, a(0)-a(2). Using the Cabibbo-Isidori model, and fixing (a(0)-a(2))m(pi)(+)=0.268 +/- 0.017 as measured by the CERN-NA48 collaboration, we present the first measurement of the K(L)->pi(0)pi(0)pi(0) quadratic slope parameter that accounts for the rescattering effect: h(000)=(+0.59 +/- 0.20(stat)+/- 0.48(syst)+/- 1.06(ext))x10(-3), where the uncertainties are from data statistics, KTeV systematic errors, and external systematic errors. Fitting for both h(000) and a(0)-a(2), we find h(000)=(-2.09 +/- 0.62(stat)+/- 0.72(syst)+/- 0.28(ext))x10(-3), and m(pi)(+)(a(0)-a(2))=0.215 +/- 0.014(stat)+/- 0.025(syst)+/- 0.006(ext); our value for a(0)-a(2) is consistent with that from NA48.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The KTeV E799 experiment has conducted a search for the rare decay K(L)->pi(0)pi(0)gamma via the topology K(L)->pi(0)pi(0)(D)gamma (where pi(0)(D)->gamma e(+)e(-)). Because of Bose statistics of the pi(0) pair and the real nature of the photon, the K(L)->pi(0)pi(0)gamma decay is restricted to proceed at lowest order by the CP conserving direct emission (DE) of an E2 electric quadrupole photon. The rate of this decay is interesting theoretically since chiral perturbation theory predicts that this process vanishes at level O(p(4)). Therefore, this mode probes chiral perturbation theory at O(p(6)). In this paper we report a determination of an upper limit of 2.43x10(-7) (90% CL) for K(L)->pi(0)pi(0)gamma. This is approximately a factor of 20 lower than previous results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a new measurement of the branching ratio B(K(L) -> pi(0)gamma gamma) using the KTeV detector. We reconstruct 1982 events with an estimated background of 608, that results in B(K(L) -> pi(0)gamma gamma)=(1.29 +/- 0.03(stat) +/- 0.05(syst)) x 10(-6). We also measure the parameter, a(V), which characterizes the strength of vector meson exchange terms in this decay. We find a(V) = -0.31 +/- 0.05(stat) +/- 0.07(syst). These results utilize the full KTeV data set collected from 1997 to 2000 and supersede earlier KTeV measurements of the branching ratio and a(V).