937 resultados para Contrast improvements
Resumo:
This paper describes an image compounding technique based on the use of different apodization functions, the evaluation of the signals phases and information from the interaction of different propagation modes of Lamb waves with defects for enhanced damage detection, resolution and contrast. A 16 elements linear array is attached to a 1 mm thickness isotropic aluminum plate with artificial defects. The array can excite the fundamental A0 and S0 modes at the frequencies of 100 kHz and 360 kHz, respectively. For each mode two synthetic aperture (SA) images with uniform and Blackman apodization and one image of Coherence Factor Map (CFM) are obtained. The specific interaction between each propagation mode and the defects and the characteristics of acoustic radiation patterns due to different apodization functions result in images with different resolution and contrast. From the phase information one of the SA images is selected at each pixel to compound the final image. The SA images are multiplied by the CFM image to improve contrast and for the dispersive A0 mode it is used a technique for dispersion compensation. There is a contrast improvement of 47.5 dB, reducing the dead zone and improving resolution and damage detection. © 2012 IEEE.
Resumo:
Plant performance is, at least partly, linked to the location of roots with respect to soil structure features and the micro-environment surrounding roots. Measurements of root distributions from intact samples, using optical microscopy and field tracings have been partially successful but are imprecise and labour-intensive. Theoretically, X-ray computed micro-tomography represents an ideal solution for non-invasive imaging of plant roots and soil structure. However, before it becomes fast enough and affordable or easily accessible, there is still a need for a diagnostic tool to investigate root/soil interplay. Here, a method for detection of undisturbed plant roots and their immediate physical environment is presented. X-ray absorption and phase contrast imaging are combined to produce projection images of soil sections from which root distributions and soil structure can be analyzed. The clarity of roots on the X-ray film is sufficient to allow manual tracing on an acetate sheet fixed over the film. In its current version, the method suffers limitations mainly related to (i) the degree of subjectivity associated with manual tracing and (ii) the difficulty of separating live and dead roots. The method represents a simple and relatively inexpensive way to detect and quantify roots from intact samples and has scope for further improvements. In this paper, the main steps of the method, sampling, image acquisition and image processing are documented. The potential use of the method in an agronomic perspective is illustrated using surface and sub-surface soil samples from a controlled wheat trial. Quantitative characterization of root attributes, e.g. radius, length density, branching intensity and the complex interplay between roots and soil structure, is presented and discussed.
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
Seit seiner Entdeckung im Jahre 1978 wurden für hyperpolarisiertes (HP) 129Xe zahlreiche Anwendungen gefunden. Aufgrund seiner hohen Verstärkung von NMR-Signalen wird es dabei typischerweise für Tracer- und Oberflächenstudien verwendet. Im gasförmigen Zustand ist es ein interessantes, klinisches Kontrastmittel, welches für dynamische Lungen MRT genutzt oder auch in Blut oder lipophilen Flüssigkeiten gelöst werden kann. Weiterhin findet HP-Xe auch in der Grundlagenphysik in He-Xe Co-Magnetometern Verwendung, mit welchen z. B. das elektrische Dipolmoment von Xe bestimmt werden soll, oder es dient zur Überprüfung auf Lorentz-Invarianzen. Alle diese Anwendungen profitieren von einem hohen Polarisationsgrad (PXe), um hohe Signalstärken und lange Lagerzeiten zu erreichen. rnIn dieser Arbeit wurden zwei mobile Xe-Polarisatoren konstruiert: einer für Experimente in der Grundlagenphysik mit einer Produktionsrate von 400 mbar·l/h mit PXe ≈ 5%. Der zweite Xe-Polarisator wurde für medizinische Anwendungen entwickelt und soll 1 bar l/h mit PXe > 20% erzeugen. Der letztere wurde noch nicht getestet. Die Arbeitsbedingungen des Xe-Polarisators für Grundlagenphysik (Strömung des Gasgemischs, Temperatur, Druck und Konzentration von Xe) wurden variiert, um einen höchstmöglichen Polarisationsgrad zu erzielen. Die maximale Polarisation von 5,6 % wurde bei Verwendung eine Gasmischung von 1% Xe bei einem Durchfluss von 200 ml/min, einer Temperatur von 150°C und einem Gesamtdruck von 4 bar erreicht. rnWeiterhin muss HP-Xe auch effizient gelagert werden, um Polarisationsverluste zu minimieren. Das ist besonders für solche Anwendungen notwendig, welche an einem entfernten Standort durchgeführt werden sollen oder auch wenn lange Spinkohärenzeiten gefordert sind, z.B. bei He-Xe Co-Magnetometern. rnHierbei bestand bisher die größte Schwierigkeit darin, die Reproduzierbarkeit der gemessenen Lagerzeiten sicherzustellen. In dieser Arbeit konnte die Spin-Gitter-Relaxationszeit (T1) von HP-129Xe in unbeschichteten, Rb-freien, sphärischen Zellen aus Aluminiumsilikatglas (GE-180) signifikant verbessert werden. Die T1–Zeit wurde in einem selbstgebauten Niederfeld-NMR-System (2 mT) sowohl für reines HP-Xe als auch für HP-Xe in Mischungen mit N2, SF6 und CO2 bestimmt. Bei diesen Experimenten wurde die maximale Relaxationszeit für reines Xe (85% 129 Xe) bei (4,6 ± 0,1) h festgestellt. Dabei lagen die typischen Wand-Relaxationszeiten bei ca. 18 h für Glaszellen mit einem Durchmesser von 10 cm. Des Weiteren wurde herausgefunden, dass CO2 eine unerwartet hohe Effizienz bei der Verkürzung der Lebensdauer der Xe-Xe Moleküle zeigte und somit zu einer deutlichen Verlängerung der gesamten T1-Zeit genutzt werden kann. rnIm Verlauf vieler Experimente wurde durch wiederholte Messungen mit der gleichen Zelle, ein "Alterungsprozess“ bei der Wandrelaxation identifiziert und untersucht. Dieser Effekt könnte leicht rückgängig gemacht werden, indem die anfängliche Reinigungsprozedur wiederholt wurde. Auf diese Weise kann eine konstante Wandrelaxation sichergestellt werden, durch die sehr reproduzierbare T1-Messungen möglich werden. rnSchließlich wurde die maximale Relaxationszeit für HP-Xe mit natürlicher Häufigkeit in Mischungen mit SF6 bestimmt. Überraschenderweise war dieser Wert um ca. 75% niedriger als der Wert für Xenon, das zu 85% mit 129Xe angereichert war. Dieser Effekt wurde durch drei unabhängige Experimente bestätigt, da er nicht von der bestehenden Theorie der Xe-Relaxation ableitbar ist. rnDie Polarisation von HP-Xe, PXe, wird normalerweise durch den Vergleich der NMR-Signale des HP-Xe mit einer thermischen polarisierten Probe (z. B. 1H2O oder Xe) bestimmt. Dabei beinhaltet der Vergleich unterschiedlicher Messungen an verschiedenen Proben (unterschiedlicher Druck, Signalintensität und Messverfahren) viele experimentelle Unsicherheiten, welche sich oft nicht leicht bestimmen lassen. Eine einfache, genaue und kostengünstige Methode zur Bestimmung von PXe durch eine direkte Messung der makroskopischen Magnetisierung in einem statischen Magnetfeld vermeidet alle diese Unsicherheiten. Dieses Verfahren kann Polarisationen von > 2 % mit einer Genauigkeit von maximal 10% fast ohne Polarisationsverlust bestimmen. Zusätzlich kann diese Methode ohne weitere Änderungen auch für Bestimmungen des Polarisationsgrades anderer HP-Gase verwendet werden.rn
Resumo:
In hemodialysis patients, radiographic imaging with iodinated contrast medium (ICM) application plays a central role in the diagnosis and/or follow-up of disease-related conditions. Therefore, safety aspects concerning ICM administration and radiation exposure have a great impact on this group of patients. Current hardware and software improvements including the design and synthesis of modern contrast compounds allow the use of very small amounts of ICM in concert with low radiation exposure. Undesirable ICM side effects are divided into type A (predictable reactions such as heat feeling, headache, and contrast-induced acute kidney injury, for example) and type B (nonpredictable or hypersensitivity) reactions; this chapter deals with the latter. The first onset cannot be prevented. To prevent hypersensitivity upon reexposure of ICM, an allergological workup is recommended. If this is not possible and ICM is necessary, the patient should receive a premedication (H1 antihistamine with or without corticosteroids). Current imaging hardware and software improvements (e.g. such as additional filtration of the X-ray beam) allow the use of very small amount of ICM and small X-ray doses. Proper communication among the team involved in the treatment of a patient may allow to apply imaging protocols and efficient imaging strategies limiting radiation exposure to a minimum. Practical recommendations will guide the reader how to use radiation and ICM efficiently to improve both patient and staff safety.
Resumo:
Performance improvements subsequent to the implementation of a pay-for-performance plan can result because more productive employees self-select into the firm (selection effect) and/or because employees allocate effort to become more effective (effort effect). We analyze individual performance data for 3,776 sales employees of a retail firm to evaluate these alternative sources of continuing performance improvement. The incentive plan helps the firm attract and retain more productive sales employees, and motivates these employees to further improve their productivity. In contrast, the less productive sales employees’ performance declines before they leave the firm.
Resumo:
In the multi-core CPU world, transactional memory (TM)has emerged as an alternative to lock-based programming for thread synchronization. Recent research proposes the use of TM in GPU architectures, where a high number of computing threads, organized in SIMT fashion, requires an effective synchronization method. In contrast to CPUs, GPUs offer two memory spaces: global memory and local memory. The local memory space serves as a shared scratch-pad for a subset of the computing threads, and it is used by programmers to speed-up their applications thanks to its low latency. Prior work from the authors proposed a lightweight hardware TM (HTM) support based in the local memory, modifying the SIMT execution model and adding a conflict detection mechanism. An efficient implementation of these features is key in order to provide an effective synchronization mechanism at the local memory level. After a quick description of the main features of our HTM design for GPU local memory, in this work we gather together a number of proposals designed with the aim of improving those mechanisms with high impact on performance. Firstly, the SIMT execution model is modified to increase the parallelism of the application when transactions must be serialized in order to make forward progress. Secondly, the conflict detection mechanism is optimized depending on application characteristics, such us the read/write sets, the probability of conflict between transactions and the existence of read-only transactions. As these features can be present in hardware simultaneously, it is a task of the compiler and runtime to determine which ones are more important for a given application. This work includes a discussion on the analysis to be done in order to choose the best configuration solution.
Resumo:
Patients with myofascial pain experience impaired mastication, which might also interfere with their sleep quality. The purpose of this study was to evaluate the jaw motion and sleep quality of patients with myofascial pain and the impact of a stabilization device therapy on both parameters. Fifty women diagnosed with myofascial pain by the Research Diagnostic Criteria were enrolled. Pain levels (visual analog scale), jaw movements (kinesiography), and sleep quality (Epworth Sleepiness Scale; Pittsburgh Sleep Quality Index) were evaluated before (control) and after stabilization device use. Range of motion (maximum opening, right and left excursions, and protrusion) and masticatory movements during Optosil mastication (opening, closing, and total cycle time; opening and closing angles; and maximum velocity) also were evaluated. Repeated-measures analysis of variance in a generalized linear mixed models procedure was used for statistical analysis (α=.05). At baseline, participants with myofascial pain showed a reduced range of jaw motion and poorer sleep quality. Treatment with a stabilization device reduced pain (P<.001) and increased both mouth opening (P<.001) and anteroposterior movement (P=.01). Also, after treatment, the maximum opening (P<.001) and closing (P=.04) velocities during mastication increased, and improvements in sleep scores for the Pittsburgh Sleep Quality Index (P<.001) and Epworth Sleepiness Scale (P=.04) were found. Myofascial pain impairs jaw motion and quality of sleep; the reduction of pain after the use of a stabilization device improves the range of motion and sleep parameters.
Resumo:
This study aims to assess the clinical and physiological effects of Roux-en-Y gastric bypass (RYGBP) on type 2 diabetes associated with mild obesity (body mass index [BMI] 30-34.9 kg/m(2)) over 24 months postsurgery. In this prospective trial, 36 mildly obese subjects (19 males) with type 2 diabetes using oral antidiabetic drugs with (n = 24) or without insulin (n = 12) underwent RYGBP. Follow-up was conducted at baseline and 3, 6, 12, and 24 months postsurgery. The following endpoints were considered: changes in HbA1c, fasting glucose and insulin, antidiabetic therapy, BMI, oral glucose insulin sensitivity [OGIS, from meal tolerance test (MTT)], beta-cell secretory function [ΔCP(0-30)/ΔGlu(0-30) (ΔC-peptide/Δglucose ratio, MTT 0-30 min), disposition index (DI = OGIS [Symbol: see text] ΔCP(0-30)/ΔGlu(0-30)], glucagon-like peptide (GLP-1) and glucose-dependent insulinotropic polypeptide (GIP) [incremental area under the curve (AUCi)], adiponectin, C-reactive protein, and lipids. All subjects achieved normal-to-overweight BMI after 3 months. Over 24 months, 31/36 (86 %) subjects presented HbA1c <7 % [complete and partial remission of diabetes in 9/36 (22 %) and 1/36 (3 %), respectively]. Since 3 months postsurgery, improvements were observed in OGIS [290 (174) to 373 (77) ml/min/m(2), P = 0.009], ΔCP(0-30)/ΔGlu(0-30) [0.24 (0.19) to 0.52 (0.34) ng/mg, P = 0.001], DI [7.16 (8.53) to 19.8 (15.4) (ng/mg) (ml/min/m(2)), P = 0.001], GLP-1 AUCi [0.56 (0.64) to 3.97 (3.86) ng/dl [Symbol: see text] 10 min [Symbol: see text] 103, P = 0.000], and GIP AUCi [30.2 (12.6) to 27.0 (20.2) ng/dl [Symbol: see text] 10 min [Symbol: see text] 103, P = 0.004]. At baseline and after 12 months, subjects with diabetes nonremission had longer diabetes duration, higher HbA1c, lower beta-cell secretory function, and higher first 30-min GIP AUCi, compared with those with remission. RYGBP improves the glucose metabolism in subjects with type 2 diabetes and mild obesity. This effect is associated with improvement of insulin sensitivity, beta-cell secretory function, and incretin secretion.
Resumo:
The development of technological routes to convert lignocellulosic biomass to liquid fuels requires an in-depth understanding of the cell wall architecture of substrates. Essential pretreatment processes are conducted to reduce biomass recalcitrance and usually increase the reactive surface area. Quantitative three-dimensional information about both bulk and surface structural features of substrates needs to be obtained to expand our knowledge of substrates. In this work, phase-contrast tomography (PCT) was used to gather information about the structure of a model lignocellulosic biomass (piassava fibers). The three-dimensional cellular organization of piassava fibers was characterized by PCT using synchrotron radiation. This technique enabled important physical features that describe the substrate piassava fibers to be visualized and quantified. The external surface area of a fiber and internal surface area of the pores in a fiber could be determined separately. More than 96% of the overall surface area available to enzymes was in the bulk substrate. The pore surface area and length exhibited a positive linear relationship, where the slope of this relationship depended on the plant tissue. We demonstrated that PCT is a powerful tool for the three-dimensional characterization of the cell wall features related to biomass recalcitrance. Original and relevant quantitative information about the structural features of the analyzed material were obtained. The data obtained by PCT can be used to improve processing routes to efficiently convert biomass feedstock into sugars.
Resumo:
In children with Duchenne muscular dystrophy, color vision losses have been related to dystrophin deletions downstream of exon 30, which affect a dystrophin isoform, Dp260, present in the retina. To further evaluate visual function in DMD children, we measured spatial, temporal, and chromatic red-green and blue-yellow contrast sensitivity in two groups of DMD children with gene deletion downstream and upstream of exon 30. Psychophysical spatial contrast sensitivity was measured for low, middle, and high spatial frequencies with achromatic gratings and for low and middle frequencies with red-green and blue-yellow chromatic gratings. Temporal contrast sensitivity was also measured with achromatic stimuli. A reduction in sensitivity at all spatial luminance contrasts was found for the DMD patients with deletion downstream of exon 30. Similar results were found for temporal luminance contrast sensitivity. Red-green chromatic contrast sensitivity was reduced in DMD children with deletion downstream of exon 30, whereas blue-yellow chromatic contrast sensitivity showed no significant differences. We conclude that visual function is impaired in DMD children. Furthermore, we report a genotype-phenotype relationship because the visual impairment occurred in children with deletion downstream but not upstream of exon 30, affecting the retinal isoform of dystrophin Dp260.
Resumo:
We measured the effects of epilepsy on visual contrast sensitivity to linear and vertical sine-wave gratings. Sixteen female adults, aged 21 to 50 years, comprised the sample in this study, including eight adults with generalized tonic-clonic seizure-type epilepsy and eight age-matched controls without epilepsy. Contrast threshold was measured using a temporal two-alternative forced-choice binocular psychophysical method at a distance of 150 cm from the stimuli, with a mean luminance of 40.1 cd/m². A one-way analysis of variance (ANOVA) applied to the linear contrast threshold showed significant differences between groups (F[3,188] = 14.829; p < .05). Adults with epilepsy had higher contrast thresholds (1.45, 1.04, and 1.18 times for frequencies of 0.25, 2.0, and 8.0 cycles per degree of visual angle, respectively). The Tukey Honestly Significant Difference post hoc test showed significant differences (p < .05) for all of the tested spatial frequencies. The largest difference between groups was in the lowest spatial frequency. Therefore, epilepsy may cause more damage to the neural pathways that process low spatial frequencies. However, epilepsy probably alters both the magnocellular visual pathway, which processes low spatial frequencies, and the parvocellular visual pathway, which processes high spatial frequencies. The experimental group had lower visual contrast sensitivity to all tested spatial frequencies.
Resumo:
A compact frequency standard based on an expanding cold (133)CS cloud is under development in our laboratory. In a first experiment, Cs cold atoms were prepared by a magneto-optical trap in a vapor cell, and a microwave antenna was used to transmit the radiation for the clock transition. The signal obtained from fluorescence of the expanding cold atoms cloud is used to lock a microwave chain. In this way the overall system stability is evaluated. A theoretical model based on a two-level system interacting with the two microwave pulses enables interpretation for the observed features, especially the poor Ramsey fringes contrast. (C) 2008 Optical Society of America.
Resumo:
Background. The radioguided localization of occult breast lesions (ROLL) technique often utilizes iodinated radiographic contrast to assure that the local injection of (99m)Tc-MAA corresponds to the location of the lesion under investigation. However, for this application, this contrast has several shortcomings. The objective of this study was to evaluate the safety, effectiveness and technical feasibility of the use of polydimethylsiloxane (PDMS) as radiological contrast and tissue marker in ROLL. Materials and methods. The safety assessment was performed by the acute toxicity study in Wistar rats (n = 50). The radiological analysis of breast tissue (n = 32) from patients undergoing reductive mammoplasty was used to verify the effectiveness of PDMS as contrast media. The technical feasibility was evaluated through the scintigraphic and histologic analysis. Results. We found no toxic effects of PDMS for this use during the observational period. It has been demonstrated in human breast tissue that the average diameter of the tissue marked by PDMS was lower than when marked by the contrast medium (p <0.001). PDMS did not interfere with the scintigraphic uptake (p = 0.528) and there was no injury in histological processing of samples. Conclusions. This study demonstrated not only the superiority of PDMS as radiological contrast in relation to the iodinated contrast, but also the technical feasibility for the same applicability in the ROLL.