946 resultados para Closed loop stability


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Model predictive control (MPC) applications in the process industry usually deal with process systems that show time delays (dead times) between the system inputs and outputs. Also, in many industrial applications of MPC, integrating outputs resulting from liquid level control or recycle streams need to be considered as controlled outputs. Conventional MPC packages can be applied to time-delay systems but stability of the closed loop system will depend on the tuning parameters of the controller and cannot be guaranteed even in the nominal case. In this work, a state space model based on the analytical step response model is extended to the case of integrating time systems with time delays. This model is applied to the development of two versions of a nominally stable MPC, which is designed to the practical scenario in which one has targets for some of the inputs and/or outputs that may be unreachable and zone control (or interval tracking) for the remaining outputs. The controller is tested through simulation of a multivariable industrial reactor system. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Durante las últimas décadas se ha producido un fenómeno global de envejecimiento en la población. Esta tendencia se puede observar prácticamente en todos los países del mundo y se debe principalmente a los avances en la medicina, y a los descensos en las tasas de fertilidad y mortalidad. El envejecimiento de la población tiene un gran impacto en la salud de los ciudadanos, y a menudo es la causa de aparición de enfermedades crónicas. Este tipo de enfermedades supone una amenaza y una carga importantes para la sociedad, especialmente en aspectos como la mortalidad o los gastos en los sistemas sanitarios. Entre las enfermedades cardiovasculares, la insuficiencia cardíaca es probablemente la condición con mayor prevalencia y afecta a 23-26 millones de personas en todo el mundo. Normalmente, la insuficiencia cardíaca presenta un mal pronóstico y una tasa de supervivencia bajas, en algunos casos peores que algún tipo de cáncer. Además, suele ser la causa de hospitalizaciones frecuentes y es una de las enfermedades más costosas para los sistemas sanitarios. La tendencia al envejecimiento de la población y la creciente incidencia de las enfermedades crónicas están llevando a una situación en la que los sistemas de salud no son capaces de hacer frente a la demanda de la sociedad. Los servicios de salud existentes tendrán que adaptarse para ser efectivos y sostenibles en el futuro. Es necesario identificar nuevos paradigmas de cuidado de pacientes, así como mecanismos para la provisión de servicios que ayuden a transformar estos sistemas sanitarios. En este contexto, esta tesis se plantea la búsqueda de soluciones, basadas en las Tecnologías de la Información y la Comunicación (TIC), que contribuyan a realizar la transformación en los sistemas sanitarios. En concreto, la tesis se centra en abordar los problemas de una de las enfermedades con mayor impacto en estos sistemas: la insuficiencia cardíaca. Las siguientes hipótesis constituyen la base para la realización de este trabajo de investigación: 1. Es posible definir un modelo basado en el paradigma de lazo cerrado y herramientas TIC que formalice el diseño de mejores servicios para pacientes con insuficiencia cardíaca. 2. El modelo de lazo cerrado definido se puede utilizar para definir un servicio real que ayude a gestionar la insuficiencia cardíaca crónica. 3. La introducción, la adopción y el uso de un servicio basado en el modelo definido se traducirá en mejoras en el estado de salud de los pacientes que sufren insuficiencia cardíaca. a. La utilización de un sistema basado en el modelo de lazo cerrado definido mejorará la experiencia del usuario de los pacientes. La definición del modelo planteado se ha basado en el estándar ISO / EN 13940- Sistema de conceptos para dar soporte a la continuidad de la asistencia. Comprende un conjunto de conceptos, procesos, flujos de trabajo, y servicios como componentes principales, y representa una formalización de los servicios para los pacientes con insuficiencia cardíaca. Para evaluar el modelo definido se ha definido un servicio real basado en el mismo, además de la implementación de un sistema de apoyo a dicho servicio. El diseño e implementación de dicho sistema se realizó siguiendo la metodología de Diseño Orientado a Objetivos. El objetivo de la evaluación consistía en investigar el efecto que tiene un servicio basado en el modelo de lazo cerrado sobre el estado de salud de los pacientes con insuficiencia cardíaca. La evaluación se realizó en el marco de un estudio clínico observacional. El análisis de los resultados ha comprendido métodos de análisis cuantitativos y cualitativos. El análisis cuantitativo se ha centrado en determinar el estado de salud de los pacientes en base a datos objetivos (obtenidos en pruebas de laboratorio o exámenes médicos). Para realizar este análisis se definieron dos índices específicos: el índice de estabilidad y el índice de la evolución del estado de salud. El análisis cualitativo ha evaluado la autopercepción del estado de salud de los pacientes en términos de calidad de vida, auto-cuidado, el conocimiento, la ansiedad y la depresión, así como niveles de conocimiento. Se ha basado en los datos recogidos mediante varios cuestionarios o instrumentos estándar (i.e. EQ-5D, la Escala de Ansiedad y Depresión (HADS), el Cuestionario de Cardiomiopatía de Kansas City (KCCQ), la Escala Holandesa de Conocimiento de Insuficiencia Cardíaca (DHFKS), y la Escala Europea de Autocuidado en Insuficiencia Cardíaca (EHFScBS), así como cuestionarios dedicados no estandarizados de experiencia de usuario. Los resultados obtenidos en ambos análisis, cuantitativo y cualitativo, se compararon con el fin de evaluar la correlación entre el estado de salud objetivo y subjetivo de los pacientes. Los resultados de la validación demostraron que el modelo propuesto tiene efectos positivos en el cuidado de los pacientes con insuficiencia cardíaca y contribuye a mejorar su estado de salud. Asimismo, ratificaron al modelo como instrumento válido para la definición de servicios mejorados para la gestión de esta enfermedad. ABSTRACT During the last decades we have witnessed a global aging phenomenon in the population. This can be observed in practically every country in the world, and it is mainly caused by the advances in medicine, and the decrease of mortality and fertility rates. Population aging has an important impact on citizens’ health and it is often the cause for chronic diseases, which constitute global burden and threat to the society in terms of mortality and healthcare expenditure. Among chronic diseases, Chronic Heart Failure (CHF) or Heart Failure (HF) is probably the one with highest prevalence, affecting between 23 and 26 million people worldwide. Heart failure is a chronic, long-term and serious condition with very poor prognosis and worse survival rates than some type of cancers. Additionally, it is often the cause of frequent hospitalizations and one of the most expensive conditions for the healthcare systems. The aging trends in the population and the increasing incidence of chronic diseases are leading to a situation where healthcare systems are not able to cope with the society demand. Current healthcare services will have to be adapted and redefined in order to be effective and sustainable in the future. There is a need to find new paradigms for patients’ care, and to identify new mechanisms for services’ provision that help to transform the healthcare systems. In this context, this thesis aims to explore new solutions, based on ICT, that contribute to achieve the needed transformation within the healthcare systems. In particular, it focuses on addressing the problems of one of the diseases with higher impact within these systems: Heart Failure. The following hypotheses represent the basis to the elaboration of this research: 1. It is possible to define a model based on a closed-loop paradigm and ICT tools that formalises the design of enhanced healthcare services for chronic heart failure patients. 2. The described closed-loop model can be exemplified in a real service that supports the management of chronic heart failure disease. 3. The introduction, adoption and use of a service based on the outlined model will result in improvements in the health status of patients suffering heart failure. 4. The user experience of patients when utilizing a system based on the defined closed-loop model will be enhanced. The definition of the closed-loop model for health care support of heart failure patients have been based on the standard ISO/EN 13940 System of concepts to support continuity of care. It includes a set of concept, processes and workflows, and services as main components, and it represent a formalization of services for heart failure patients. In order to be validated, the proposed closed-loop model has been instantiated into a real service and a supporting IT system. The design and implementation of the system followed the user centred design methodology Goal Oriented Design. The validation, that included an observational clinical study, aimed to investigate the effect that a service based on the closed-loop model had on heart failure patients’ health status. The analysis of results comprised quantitative and qualitative analysis methods. The quantitative analysis was focused on determining the health status of patients based on objective data (obtained in lab tests or physical examinations). Two specific indexes where defined and considered in this analysis: the stability index and the health status evolution index. The qualitative analysis assessed the self-perception of patients’ health status in terms of quality of life, self-care, knowledge, anxiety and depression, as well as knowledge levels. It was based on the data gathered through several standard instruments (i.e. EQ-5D, the Hospital Anxiety and Depression Scale, the Kansas City Cardiomyopathy Questionnaire, the Dutch Heart Failure Knowledge Scale, and the European Heart Failure Self-care Behaviour Scale) as well as dedicated non-standardized user experience questionnaires. The results obtained in both analyses, quantitative and qualitative, were compared in order to assess the correlation between the objective and subjective health status of patients. The results of the validation showed that the proposed model contributed to improve the health status of the patients and had a positive effect on the patients’ care. It also proved that the model is a valid instrument for designing enhanced healthcare services for heart failure patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among several process variability sources, valve friction and inadequate controller tuning are supposed to be two of the most prevalent. Friction quantification methods can be applied to the development of model-based compensators or to diagnose valves that need repair, whereas accurate process models can be used in controller retuning. This paper extends existing methods that jointly estimate the friction and process parameters, so that a nonlinear structure is adopted to represent the process model. The developed estimation algorithm is tested with three different data sources: a simulated first order plus dead time process, a hybrid setup (composed of a real valve and a simulated pH neutralization process) and from three industrial datasets corresponding to real control loops. The results demonstrate that the friction is accurately quantified, as well as ""good"" process models are estimated in several situations. Furthermore, when a nonlinear process model is considered, the proposed extension presents significant advantages: (i) greater accuracy for friction quantification and (ii) reasonable estimates of the nonlinear steady-state characteristics of the process. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work deals with a procedure for model re-identification of a process in closed loop with ail already existing commercial MPC. The controller considered here has a two-layer structure where the upper layer performs a target calculation based on a simplified steady-state optimization of the process. Here, it is proposed a methodology where a test signal is introduced in a tuning parameter of the target calculation layer. When the outputs are controlled by zones instead of at fixed set points, the approach allows the continuous operation of the process without an excessive disruption of the operating objectives as process constraints and product specifications remain satisfied during the identification test. The application of the method is illustrated through the simulation of two processes of the oil refining industry. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Motivated by the dark matter and the baryon asymmetry problems, we analyze a complex singlet extension of the Standard Model with a Z(2) symmetry (which provides a dark matter candidate). After a detailed two-loop calculation of the renormalization group equations for the new scalar sector, we study the radiative stability of the model up to a high energy scale (with the constraint that the 126 GeV Higgs boson found at the LHC is in the spectrum) and find it requires the existence of a new scalar state mixing with the Higgs with a mass larger than 140 GeV. This bound is not very sensitive to the cutoff scale as long as the latter is larger than 10(10) GeV. We then include all experimental and observational constraints/measurements from collider data, from dark matter direct detection experiments, and from the Planck satellite and in addition force stability at least up to the grand unified theory scale, to find that the lower bound is raised to about 170 GeV, while the dark matter particle must be heavier than about 50 GeV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Type 1 diabetic patients depend on external insulin delivery to keep their blood glucose within near-normal ranges. In this work, two robust closed-loop controllers for blood glucose regulation are developed to prevent the life-threatening hypoglycemia, as well as to avoid extended hyperglycemia. The proposed controllers are designed by using the sliding mode control technique in a Smith predictor structure. To improve meal disturbance rejection, a simple feedforward controller is added to inject meal-time insulin bolus. Simulations scenarios were used to test the controllers, and showed the controllers ability to maintain the glucose levels within the safe limits in the presence of errors in measurements, modeling and meal estimation

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of motor training using closed loop controlled Functional Electrical Stimulation (FES) on motor performance was studied in 5 spinal cord injured (SCI) volunteers. The subjects trained 2 to 3 times a week during 2 months on a newly developed rehabilitation robot (MotionMaker?). The FES induced muscle force could be adequately adjusted throughout the programmed exercises by the way of a closed loop control of the stimulation currents. The software of the MotionMaker? allowed spasms to be detected accurately and managed in a way to prevent any harm to the SCI persons. Subjects with incomplete SCI reported an increased proprioceptive awareness for motion and were able to achieve a better voluntary activation of their leg muscles during controlled FES. At the end of the training, the voluntary force of the 4 incomplete SCI patients was found increased by 388% on their most affected leg and by 193% on the other leg. Active mobilisation with controlled FES seems to be effective in improving motor function in SCI persons by increasing the sensory input to neuronal circuits involved in motor control as well as by increasing muscle strength.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report explores the design and control issues associated with a brushless actuator capable of achieving extremely high torque accuracy. Models of several different motor - sensor configurations were studied to determine dynamic characteristics. A reaction torque sensor fixed to the motor stator was implemented to decouple the transmission dynamics from the sensor. This resulted in a compact actuator with higher bandwidth and precision than could be obtained with an inline or joint sensor. Testing demonstrated that closed-loop torque accuracy was within 0.1%, and the mechanical bandwidth approached 300 Hz.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A recent area for investigation into the development of adaptable robot control is the use of living neuronal networks to control a mobile robot. The so-called Animat paradigm comprises a neuronal network (the ‘brain’) connected to an external embodiment (in this case a mobile robot), facilitating potentially robust, adaptable robot control and increased understanding of neural processes. Sensory input from the robot is provided to the neuronal network via stimulation on a number of electrodes embedded in a specialist Petri dish (Multi Electrode Array (MEA)); accurate control of this stimulation is vital. We present software tools allowing precise, near real-time control of electrical stimulation on MEAs, with fast switching between electrodes and the application of custom stimulus waveforms. These Linux-based tools are compatible with the widely used MEABench data acquisition system. Benefits include rapid stimulus modulation in response to neuronal activity (closed loop) and batch processing of stimulation protocols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants: Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention: Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures: Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results: Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (p<0.001; χ2 test). MAEs occurred in 7.0% of 1473 non-intravenous doses pre-intervention and 4.3% of 1139 afterwards (p = 0.005; χ2 test). Patient identity was not checked for 82.6% of 1344 doses pre-intervention and 18.9% of 1291 afterwards (p<0.001; χ2 test). Medical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions: A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To assess the impact of a closed-loop electronic prescribing and automated dispensing system on the time spent providing a ward pharmacy service and the activities carried out. Setting Surgical ward, London teaching hospital. Method All data were collected two months pre- and one year post-intervention. First, the ward pharmacist recorded the time taken each day for four weeks. Second, an observational study was conducted over 10 weekdays, using two-dimensional work sampling, to identify the ward pharmacist's activities. Finally, medication orders were examined to identify pharmacists' endorsements that should have been, and were actually, made. Key findings Mean time to provide a weekday ward pharmacy service increased from 1 h 8 min to 1 h 38 min per day (P = 0.001; unpaired t-test). There were significant increases in time spent prescription monitoring, recommending changes in therapy/monitoring, giving advice or information, and non-productive time. There were decreases for supply, looking for charts and checking patients' own drugs. There was an increase in the amount of time spent with medical and pharmacy staff, and with 'self'. Seventy-eight per cent of patients' medication records could be assessed for endorsements pre- and 100% post-intervention. Endorsements were required for 390 (50%) of 787 medication orders pre-intervention and 190 (21%) of 897 afterwards (P < 0.0001; chi-square test). Endorsements were made for 214 (55%) of endorsement opportunities pre-intervention and 57 (30%) afterwards (P < 0.0001; chi-square test). Conclusion The intervention increased the overall time required to provide a ward pharmacy service and changed the types of activity undertaken. Contact time with medical and pharmacy staff increased. There was no significant change in time spent with patients. Fewer pharmacy endorsements were required post-intervention, but a lower percentage were actually made. The findings have important implications for the design, introduction and use of similar systems.