939 resultados para Circuit optimisation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A systematic method to improve the quality (Q) factor of RF integrated inductors is presented in this paper. The proposed method is based on the layout optimization to minimize the series resistance of the inductor coil, taking into account both ohmic losses, due to conduction currents, and magnetically induced losses, due to eddy currents. The technique is particularly useful when applied to inductors in which the fabrication process includes integration substrate removal. However, it is also applicable to inductors on low-loss substrates. The method optimizes the width of the metal strip for each turn of the inductor coil, leading to a variable strip-width layout. The optimization procedure has been successfully applied to the design of square spiral inductors in a silicon-based multichip-module technology, complemented with silicon micromachining postprocessing. The obtained experimental results corroborate the validity of the proposed method. A Q factor of about 17 have been obtained for a 35-nH inductor at 1.5 GHz, with Q values higher than 40 predicted for a 20-nH inductor working at 3.5 GHz. The latter is up to a 60% better than the best results for a single strip-width inductor working at the same frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The impending introduction of lead-free solder in the manufacture of electrical and electronic products has presented the electronics industry with many challenges. European manufacturers must transfer from a tin-lead process to a lead-free process by July 2006 as a result of the publication of two directives from the European Parliament. Tin-lead solders have been used for mechanical and electrical connections on printed circuit boards for over fifty years and considerable process knowledge has been accumulated. Extensive literature reviews were conducted on the topic and as a result it was found there are many implications to be considered with the introduction of lead-free solder. One particular question that requires answering is; can lead-free solder be used in existing manufacturing processes? The purpose of this research is to conduct a comparative study of a tin-lead solder and a lead-free solder in two key surface mount technology (SMT) processes. The two SMT processes in question were the stencil printing process and the reflow soldering process. Unreplicated fractional factorial experimental designs were used to carry out the studies. The quality of paste deposition in terms of height and volume were the characteristics of interest in the stencil printing process. The quality of solder joints produced in the reflow soldering experiment was assessed using x-ray and cross sectional analysis. This provided qualitative data that was then uniquely scored and weighted using a method developed during the research. Nested experimental design techniques were then used to analyse the resulting quantitative data. Predictive models were developed that allowed for the optimisation of both processes. Results from both experiments show that solder joints of comparable quality to those produced using tin-lead solder can be produced using lead-free solder in current SMT processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper includes the experimental study, analysis, redesign and subsequent test of the parts of a closed circuit, low speed wind tunnel which are relevant in terms of total pressure loss. The objective is to lower the energy consumption of this system for given conditions in test chamber, so as to reduce the operational costs. In order to achieve this objective, several tasks were performed as the text shows in its different parts. For these tasks, the ETSIAE wind tunnel was used, although the results of this work can be extrapolated to any wind tunnel with the same characteristics. Part II presents a theoretical previous study of the general running of a closed circuit, low speed wind tunnel, as well as the followed procedure to conduct experimental tests for obtaining the total pressure loss in its parts. Results from these tests and their analysis are included in this part. In part III, the analysis of the influence of corner 1 on the pressure loss takes place. As it is said in this part, corner 1 has great importance in the total pressure loss of the wind tunnel. Therefore, it is the first part that should be modified in order to improve the performances of the wind tunnel. During part IV, an optimised guide vane is designed in order to reduce the pressure loss in corner 1 of the wind tunnel. Software MISES is used to achieve this goal by means of selecting the optimum guide vane. In order to introduce the new guide vane in wind tunnels with affordable costs, the easily constructable criterion is kept during design. For this reason, the guide vane will consist of simple aerodynamic contours. Part V includes some possible improvements for the proposed guide vane, in order to evaluate if there is room for improvement in its design. Finally, part VI includes the tests that were conducted in the wind tunnel with the new guide vane cascade and the analysis of their results, in order to asses whether the proposed design fulfills the requirement of lowering the total pressure loss in the wind tunnel. Part VII gathers the main ideas resulting from the whole work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the work described here has been to seek methods of narrowing the present gap between currently realised heat pump performance and the theoretical limit. The single most important pre-requisite to this objective is the identification and quantitative assessment of the various non-idealities and degradative phenomena responsible for the present shortfall. The use of availability analysis has been introduced as a diagnostic tool, and applied to a few very simple, highly idealised Rankine cycle optimisation problems. From this work, it has been demonstrated that the scope for improvement through optimisation is small in comparison with the extensive potential for improvement by reducing the compressor's losses. A fully instrumented heat pump was assembled and extensively tested. This furnished performance data, and led to an improved understanding of the systems behaviour. From a very simple analysis of the resulting compressor performance data, confirmation of the compressor's low efficiency was obtained. In addition, in order to obtain experimental data concerning specific details of the heat pump's operation, several novel experiments were performed. The experimental work was concluded with a set of tests which attempted to obtain definitive performance data for a small set of discrete operating conditions. These tests included an investigation of the effect of two compressor modifications. The resulting performance data was analysed by a sophisticated calculation which used that measurements to quantify each dagradative phenomenon occurring in that compressor, and so indicate where the greatest potential for improvement lies. Finally, in the light of everything that was learnt, specific technical suggestions have been made, to reduce the losses associated with both the refrigerant circuit and the compressor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reliability of the printed circuit board assembly under dynamic environments, such as those found onboard airplanes, ships and land vehicles is receiving more attention. This research analyses the dynamic characteristics of the printed circuit board (PCB) supported by edge retainers and plug-in connectors. By modelling the wedge retainer and connector as providing simply supported boundary condition with appropriate rotational spring stiffnesses along their respective edges with the aid of finite element codes, accurate natural frequencies for the board against experimental natural frequencies are obtained. For a PCB supported by two opposite wedge retainers and a plug-in connector and with its remaining edge free of any restraint, it is found that these real supports behave somewhere between the simply supported and clamped boundary conditions and provide a percentage fixity of 39.5% more than the classical simply supported case. By using an eigensensitivity method, the rotational stiffnesses representing the boundary supports of the PCB can be updated effectively and is capable of representing the dynamics of the PCB accurately. The result shows that the percentage error in the fundamental frequency of the PCB finite element model is substantially reduced from 22.3% to 1.3%. The procedure demonstrated the effectiveness of using only the vibration test frequencies as reference data when the mode shapes of the original untuned model are almost identical to the referenced modes/experimental data. When using only modal frequencies in model improvement, the analysis is very much simplified. Furthermore, the time taken to obtain the experimental data will be substantially reduced as the experimental mode shapes are not required.In addition, this thesis advocates a relatively simple method in determining the support locations for maximising the fundamental frequency of vibrating structures. The technique is simple and does not require any optimisation or sequential search algorithm in the analysis. The key to the procedure is to position the necessary supports at positions so as to eliminate the lower modes from the original configuration. This is accomplished by introducing point supports along the nodal lines of the highest possible mode from the original configuration, so that all the other lower modes are eliminated by the introduction of the new or extra supports to the structure. It also proposes inspecting the average driving point residues along the nodal lines of vibrating plates to find the optimal locations of the supports. Numerical examples are provided to demonstrate its validity. By applying to the PCB supported on its three sides by two wedge retainers and a connector, it is found that a single point constraint that would yield maximum fundamental frequency is located at the mid-point of the nodal line, namely, node 39. This point support has the effect of increasing the structure's fundamental frequency from 68.4 Hz to 146.9 Hz, or 115% higher.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we explore optimising parameters of a physical circuit model relative to input/output measurements, using the Dallas Rangemaster Treble Booster as a case study. A hybrid metaheuristic/gradient descent algorithm is implemented, where the initial parameter sets for the optimisation are informed by nominal values from schematics and datasheets. Sensitivity analysis is used to screen parameters, which informs a study of the optimisation algorithm against model complexity by fixing parameters. The results of the optimisation show a significant increase in the accuracy of model behaviour, but also highlight several key issues regarding the recovery of parameters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les percidés, dont le doré jaune (Sander vitreus), représentent une opportunité considérable de diversification de l’offre pour l’industrie aquacole au Canada, mais aussi ailleurs dans le monde. Malgré son fort potentiel, les producteurs de dorés sont marginaux, car l’élevage larvaire s’avère difficile et complexe, résultant en des succès de survie variables. Pour un développement durable de l’aquaculture, mais aussi pour assurer un meilleur contrôle des paramètres environnementaux, et conséquemment une meilleure rentabilité, les nouvelles méthodes d’élevage s’orientent vers l’utilisation de systèmes en recirculation où l’eau est majoritairement filtrée et recyclée. Un premier volet de nos travaux réalisés en 2014 a confirmé que (i) les méthodes intensives d’élevage larvaire peuvent être adaptés dans les systèmes en recirculation, que (ii) la moulée commerciale enrichie de farine de krills offre une meilleure croissance qu’une moulée commerciale enrichie aux microalgues, (iii) que des artémies vivantes ne favorise pas l’ingestion alimentaire lorsqu’ils sont ajoutés à des rations d’une moulée commerciale enrichie de farine de krills et (iv) que le développement de la vessie natatoire est le défi principal afin de produire du doré en circuit recyclé de façon rentable. Une étude menée en 2015 visait à favoriser le développement de la vessie natatoire du doré dans les systèmes en recirculation. Quatre traitements ont été comparés soit, un jet d’eau de surface faible, un jet d’eau de surface fort, un microbulleur et un rondin commercial d’absorption d’huile. Nous avons démontré que (i) l’utilisation d’un jet d’eau de surface faible n’était pas suffisant pour favoriser le développement de la vessie natatoire du doré dans les systèmes où l’eau est fortement recirculée et (ii) qu’un rondin d’absorption d’huile est le dispositif le plus efficace pour favoriser le développement de la vessie natatoire du doré. Les prochains travaux devraient se pencher sur (i) l’élaboration de bassins adaptés aux réalités de l’élevage intensif des percidés, (ii) sur des efforts de domestication du doré par sélection génétique afin d’augmenter la survie dans les systèmes en recirculation et sur (iii) des études bioéconomiques afin de réduire les risques associés aux démarrages de nouvelles piscicultures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Originally from Asia, Dovyalis hebecarpa is a dark purple/red exotic berry now also produced in Brazil. However, no reports were found in the literature about phenolic extraction or characterisation of this berry. In this study we evaluate the extraction optimisation of anthocyanins and total phenolics in D. hebecarpa berries aiming at the development of a simple and mild analytical technique. Multivariate analysis was used to optimise the extraction variables (ethanol:water:acetone solvent proportions, times, and acid concentrations) at different levels. Acetone/water (20/80 v/v) gave the highest anthocyanin extraction yield, but pure water and different proportions of acetone/water or acetone/ethanol/water (with >50% of water) were also effective. Neither acid concentration nor time had a significant effect on extraction efficiency allowing to fix the recommended parameters at the lowest values tested (0.35% formic acid v/v, and 17.6 min). Under optimised conditions, extraction efficiencies were increased by 31.5% and 11% for anthocyanin and total phenolics, respectively as compared to traditional methods that use more solvent and time. Thus, the optimised methodology increased yields being less hazardous and time consuming than traditional methods. Finally, freeze-dried D. hebecarpa showed high content of target phytochemicals (319 mg/100g and 1,421 mg/100g of total anthocyanin and total phenolic content, respectively).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the hypothesis that chronic pain development (pain chronification) and ongoing chronic pain (chronic pain) reduce the activity and induce plastic changes in an endogenous analgesia circuit, the ascending nociceptive control. An important mechanism mediating this form of endogenous analgesia, referred to as capsaicin-induced analgesia, is its dependence on nucleus accumbens μ-opioid receptor mechanisms. Therefore, we also investigated whether pain chronification and chronic pain alter the requirement for nucleus accumbens μ-opioid receptor mechanisms in capsaicin-induced analgesia. We used an animal model of pain chronification in which daily subcutaneous prostaglandin E2 (PGE2) injections into the rat's hind paw for 14 days, referred to as the induction period of persistent hyperalgesia, induce a long-lasting state of nociceptor sensitization referred to as the maintenance period of persistent hyperalgesia, that lasts for at least 30 days following the cessation of the PGE2 treatment. The nociceptor hypersensitivity was measured by the shortening of the time interval for the animal to respond to a mechanical stimulation of the hind paw. We found a significant reduction in the duration of capsaicin-induced analgesia during the induction and maintenance period of persistent mechanical hyperalgesia. Intra-accumbens injection of the μ-opioid receptor selective antagonist Cys(2),Tyr(3),Orn(5),Pen(7)amide (CTOP) 10 min before the subcutaneous injection of capsaicin into the rat's fore paw blocked capsaicin-induced analgesia. Taken together, these findings indicate that pain chronification and chronic pain reduce the duration of capsaicin-induced analgesia, without affecting its dependence on nucleus accumbens μ-opioid receptor mechanisms. The attenuation of endogenous analgesia during pain chronification and chronic pain suggests that endogenous pain circuits play an important role in the development and maintenance of chronic pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the open circuit interaction of methanol and ethanol with oxidized platinum electrodes using in situ infrared spectroscopy. For methanol, it was found that formic acid is the main species formed in the initial region of the transient and that the steep decrease of the open circuit potential coincides with an explosive increase in the CO(2) production, which is followed by an increase in the coverage of adsorbed CO. For ethanol, acetaldehyde was the main product detected and only traces of dissolved CO(2) and adsorbed CO were found after the steep potential decay. In both cases, the transients were interpreted in terms of (a) the emergence of sub-surface oxygen in the beginning of the transient, where the oxide content is high, and (b) the autocatalytic production of free platinum sites for lower oxide content during the steep decay of the open circuit potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The purpose of present study was to compare the acute physiological responses to a circuit weight training with the responses to a combined circuit training (weight training and treadmill run). Methods. The sample consisted of 25 individuals at an average state of training, 10 men and 15 female, between 18 and 35 year old. There were selected 60 second sets of resistance exercises to the circuit weight training (CWT). Whereas in the combined circuit training (CCT), the subjects spent 30 seconds on the same resistance exercises and 30 seconds running on the treadmill. The rest intervals between the sets lasted 15 seconds. The analysis of variance (ANOVA) with 5% significance level was utilized to the statistical analysis of the results. Results. Comparing circuit training protocols, it was noted that CCT elicits a higher relative and absolute <(V)over dot>O(2) and energy expenditure values than CWT for both genders (P<0.05). Regarding inter-gender comparison, males showed higher absolute and relative <(V)over dot>O(2) and absolute energy expenditure values for both CWT and CCT than females (P<0.05). Females showed a significant greater % <(V)over dot>O(2max) value for both CWT and CCT. Due to the experimental conditions used to state both circuit training bouts (CWT and CCT), the <(V)over dot>O(2) rate found was higher than the values reported by previous studies which used heavier weight lift. Conclusion. CCT seems adequate to produce cardiovascular improvements and greater energy expenditure for both men and women, while CWT group classes are sufficient only for unfit women.