939 resultados para Cinemetria. Estimulação transcraniana por corrente contínua. Controle do movimento. Para-halterofilismo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The sport practiced by people with disabilities has been growing in recent years. Consequently, advances in assessment and training methods have emerged. However, the paralympic sport keeps in tow these advances, with few specific studies that consider disability as intervening factor. The transcranial direct current stimulation (tDCS) is a technique that has proven to be capable of modulating brain function. Studies show beneficial effects of tDCS on muscle strength, power and fatigue during exercise. Objective: Investigate de the effect of tDCS on movement control in para-powerlifters. Methods: Eight subjects underwent two sessions of motion capture, which previously applied the anodic tDCS or sham sessions in the cerebellum. Three movements were performed with increasing load between 90-95% of 1MR. The movements were recorded by an 10 infrared cameras system which reconstructed the 3D trajectory of markers placed on the bar. Results: There have been changes between the anodic and sham conditions over bar level (initial, final, maximum during the eccentric and concentric phase) and in the difference between the final and initial bar level. Moreover, there was difference in bar level (final and during the eccentric phase) comparing athletes amputees and les autres. Conclusion: The findings of this study suggest that tDCS applied prior to the exercise over the cerebellum in para-powerlifters acts differently according to disability

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Transcranial Direct Current Stimulation (tDCS) has been used in studies for the treatment of chronic pain, but their effects on the autonomic nervous system (ANS) are non-existent. Therefore, the need for studies is of fundamental importance, as these individuals have autonomic imbalance and the intensity of this is dependent on the degree and level of injury. Objective: We investigated the effect of tDCS on the ANS in people with spinal cord injury (SCI) with different degrees and levels of injury. Methods: Randomized, placebo-controlled, double-blind, applied anodal tDCS or sham on the primary motor cortex (M1), bilaterally. The subjects (lower incomplete injury, n = 7; lower complete injury, n = 9; and high complete thoracic injury, n = 3) visited the laboratory three times and received active or sham tDCS for 13min. The heart rate variability (HRV) was measured before, during and after stimulation and analyzed the variables LF, HF and LF / HF. Results: The tDCS modulated the ANS in different ways among the groups. In individuals with SCI high complete thoracic the tDCS did not change the HRV. However, for individuals with SCI low incomplete, tDCS changed the HRV in order to increase sympathetic (LF, p = 0.046) and reduced parasympathetic (HF, p = 0.046). For individuals SCI low complete to tDCS changed the HRV reduction sympathetic (LF, p = 0.017) and increased parasympathetic (HF, p = 0.017). Conclusions: The present study suggests that anodal tDCS applied on the motor cortex bilaterally could modulate the ANS balance in people with spinal cord injury and that this effect is dependent on the degree and level of injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estimulação transcraniana por corrente contínua (ETCC) sobre áreas corticais pré-selecionadas, tem aumentado o desempenho físico de diferentes populações. Porém, lacunas persistem no tocante aos mecanismos subjacentes à estes efeitos. Assim, a presente tese objetivou: a) investigar os efeitos da ETCC anódica (aETCC) e placebo (Sham) no córtex motor (CM) de indivíduos saudáveis sobre o desempenho de força máxima; b) comparar os efeitos da ETCC sobre a produção de força máxima e estabilidadade da força durante exercícios máximo e submáximo em sujeitos hemiparéticos e saudáveis; c) investigar o efeito da ETCC sobre a conectividade funcional inter-hemisférica (coerência eletroencefalográfica cEEG) do córtex pré-frontal (CPF), desempenho aeróbio e dispêndio energético (EE) durante e após exercício máximo e submáximo. No 1 estudo, 14 adultos saudáveis executaram 2 sessões de exercício máximo de força (EMF) dos músculos flexores e extensores do joelho dominante (3 séries de 10 rep máximas), precedidos por aETCC ou Sham (2mA; 20 mim). aETCC não foi capaz de aumentar o trabalho total e pico de torque (PT), resistência à fadiga ou atividade eletromiográfica durante o EMF. No 2 estudo, 10 hemiparéticos e 9 sujeitos saudáveis receberam aETCC e Sham no CM. O PT e a estabilidade da força (coeficiente de variação - CV) foram avaliados durante protocolo máximo e submáximo de extensão e flexão unilateral do joelho (1 série de 3 reps a 100% do PT e 2 séries de 10 reps a 50% do PT). Nenhuma diferença no PT foi observada nos dois grupos. Diminuições no CV foram obervadas durante a extensão (~25-35%, P<0.001) e flexão de joelho (~22-33%, P<0.001) após a aETCC comparada com Sham nos hemiparéticos, entretanto, somente o CV na extensão de joelhos diminuiu (~13-27%, P<0.001) nos saudáveis, o que sugere que aETCC pode melhorar o CV, mas não o PT em sujeitos hemiparéticos. No 3 estudo, 9 adultos saudáveis realizaram 2 testes incrementais máximos precedidos por aETCC ou Sham sobre o CPF com as respostas cardiorrespiratórias, percepção de esforço (PSE) e cEEG do CPF sendo monitoradas. O VO2 de pico (42.64.2 vs. 38.23.3 mL.kg.min-1; P=0,02), potência total (252.776.5 vs. 23773.3 W; P=0,05) e tempo de exaustão (531.1140 vs. 486.7115.3 seg; P=0,04) foram maiores após aETCC do que a Sham. Nenhuma diferença foi encontrada para FC e PSE em função da carga de trabalho (P>0,05). A cEEG do CPF aumentou após aETCC vs. repouso (0.700.40 vs. 0.380.05; P=0,001), mas não após Sham vs. repouso (0.360.49 vs. 0.330.50; P=0,06), sugerindo que a aETCC pode retardar a fadiga aumentando a conectividade funcional entre os hemisférios do CPF e desempenho aeróbio durante exercício exaustivo. No 4 estudo, o VO2 e EE foram avaliados em 11 adultos saudáveis antes, durante a aETCC ou Sham no CPF e 30 min após exercício aeróbio submáximo isocalórico (~200kcal). Diferenças não foram observadas no VO2 vs. repouso durante aETCC e Sham (P=0.95 e P=0.85). Porém, a associação entre exercício e aETCC aumentou em ~19% o EE após ao menos, 30 min de recuperação após exercício quando comparada a Sham (P<0,05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fluctuacion force has been increasingly used in studies with elderly as a good predictor of performance and functionality of the motor. However, most analyzes the fluctuation of force in one session. Thus, identifying the minimum amount of sessions needed for familiarization with the fluctuation strength in isometric exercise become relevant. Furthermore, to investigate the effects of applying transcranial direct current stimulation (tDCS) associated with regular exercise on rates fluctuation task force is extremely important. In the first experiment, volunteers were subjected to a protocol marked by a familiarization session to establish the parameters of VCM and eight sessions with intensity of 30% MVC in office. It was observed that two familiarization sessions are required so there is a fluctuation stabilizing force. In experiment II, subjects performed an isometric contraction before and after applying tDCS (cathode, anode and sham) applied to M1. ETCC anodic effectively contributed to reducing the fluctuation of force during isometric exercise in the elderly, while the cathodic caused the increased levels of strength fluctuation. It was concluded that there is a need to implement a familiarization protocol with at least two sessions to avoid possible misunderstandings of measurements in tests of fluctuacion force. Besides that tDCS interfered with the behavior of the oscillations of force, with cathodic promoting increased fluctuation strength and anodic contributed to greater stability, demonstrating the potential of this technique neuromodulation associated with exercise as rehabilitation tools

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A estimulação transcraniana por corrente contínua (ETCC) é uma técnica não invasiva que apresenta características anti-fadigante e analgésica. Com o objetivo de testar seus efeitos sobre a diminuição da força e do aparecimento da dor muscular de início tardio (DMIT), apresentados após um evento de dano muscular induzido pelo exercício (DMIE), foi utilizado um estudo clínico de caráter experimental, controlado, randomizado e duplo-cego. A amostra foi composta por 24 jovens do sexo masculino, aparentemente saudáveis (19,7±1,8 anos; 23,6±3,65 IMC), os quais foram alocada, de forma aleatória e estratificada, nos seguintes grupos: G1: grupo controle; G2: grupo de estimulação após o dano e G3: grupo com estimulação antes e após o dano muscular. Os dados foram submetidos à estatística descritiva e análise de variância ANOVA, adotando-se um nível de significância de 5%. O aumento nos níveis séricos de CK (56.18%) e LDH (24,15%) comprovou a ocorrência do DMIE. Em contrapartida, após a análise de variância para comparação dos tratamentos aplicados, pode-se observar que não houve diferenças significativas nos níveis de CK (p= 0,3514) e força muscular (p= 0,9702). A DMIT transcorreu como esperado, mas sem diferença significativa entre os grupos (p= 0,4861). Estes dados demonstraram que a ETCC não foi capaz de modular a DMIT e a diminuição da força muscular após o DMIE em jovens aparentemente saudáveis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The time perception is critical for environmental adaptation in humans and other species. The temporal processing, has evolved through different neural systems, each responsible for processing different time scales. Among the most studied scales is that spans the arrangement of seconds to minutes. Evidence suggests that the dorsolateral prefrontal (DLPFC) cortex has relationship with the time perception scale of seconds. However, it is unclear whether the deficit of time perception in patients with brain injuries or even "reversible lesions" caused by transcranial magnetic stimulation (TMS) in this region, whether by disruption of other cognitive processes (such as attention and working memory) or the time perception itself. Studies also link the region of DLPFC in emotional regulation and specifically the judgment and emotional anticipation. Given this, our objective was to study the role of the dorsolateral prefrontal cortex in the time perception intervals of active and emotionally neutral stimuli, from the effects of cortical modulation by transcranial direct current stimulation (tDCS), through the cortical excitation (anodic current), inhibition (cathode current) and control (sham) using the ranges of 4 and 8 seconds. Our results showed that there is an underestimation when the picture was presented by 8 seconds, with the anodic current in the right DLPFC, there is an underestimation and with cathodic current in the left DLPFC, there is an overestimation of the time reproduction with neutral ones. The cathodic current over the left DLPFC leads to an inverse effect of neutral ones, an underestimation of time with negative pictures. Positive or negative pictures improved estimates for 8 second and positive pictures inhibited the effect of tDCS in DLPFC in estimating time to 4 seconds. With this work, we conclude that the DLPFC plays a key role in the o time perception and largely corresponds to the stages of memory and decision on the internal clock model. The left hemisphere participates in the perception of time in both active and emotionally neutral contexts, and we can conclude that the ETCC and an effective method to study the cortical functions in the time perception in terms of cause and effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese de doutoramento, Psicologia, Faculdade de Ciências Humanas e Sociais, Universidade do Algarve, 2015

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Revestimentos produzidos a partir de ligas de Zn-Co são comumente utilizados em indústrias (aeronáutica, de isoladores elétricos e automobilística, por exemplo) devido à sua ótima resistência à corrosão, principalmente quando comparados aos tradicionais revestimentos de Zn puro. Na co-deposição de zinco com metais, como o ferro, cobalto e níquel, ocorre o que se chama de deposição anômala, onde o metal menos nobre (zinco) é preferencialmente depositado, independente do modo de corrente aplicada (contínua ou pulsada). Recentemente, diversos trabalhos relacionam a produção de eletrodepósitos de liga Zn-Co a partir de banhos ambientalmente não agressivos, a fim de substituir os banhos alcalinos extremamente tóxicos, a base de cianeto. Na presente dissertação foram produzidos revestimentos de ligas de Zn-Co sobre substrato de aço carbono, empregando corrente contínua ou corrente pulsada simples, a partir de banhos contendo diferentes concentrações de Co2+ (0,05 mol/L e 0,10mol/L), 0,05 mol/l de Zn2+ e citrato de sódio (0,10 mol/L) como agente complexante, sob condições agitadas. Quatro diferentes valores de densidade de corrente (10 A/m2, 20 A/m2, 40 A/m2 e 80 A/m2) e de frequência de pulso (100 Hz, 500 Hz, 1000 Hz, 2000 Hz) foram aplicados para a produção da liga a partir dos dois banhos, tendo como objetivo avaliar a influência dos parâmetros de deposição(concentração de Co (II), densidade de corrente aplicada e, no caso de deposição por corrente pulsada simples, também da frequência de pulso), nas variáveis eficiência de corrente catódica, composição da liga, densidade de corrente de corrosão, microestrutura e morfologia dos depósitos de liga Zn-Co. As cores das camadas obtidas variaram do cinza claro ao escuro, quase sempre sem brilho, independente do modo de corrente empregado. Foi verificado que o processo normal de eletrodeposição foi prevalente na produção de revestimentos por corrente contínua, enquanto que apenas deposição anômala foi observada quando do uso de corrente pulsada. A maior eficiência de corrente catódica (60%) foi obtida, para corrente contínua, nas condições de menor concentração de Co2+ (0,05 mol/L) e maior densidade de corrente (80 A/m2). Nestas mesmas condições foi determinada uma eficiência de corrente catódica de 98% para corrente pulsada simples na freqüência de 2000 Hz. Maiores teores do metal mais nobre (cobalto) foram alcançados em maiores densidades de corrente para todas as condições empregadas. Os revestimentos assim obtidos apresentavam os menores valores de tamanho de grão, para cada uma das soluções estudadas. Os demais parâmetros estudados também influenciaram na granulometria e na morfologia das ligas obtidas. Revestimentos com melhor resistência à corrosão, contendo teores de cobalto entre aproximadamente 8 e 10% m/m, foram produzidos a partir do banho com maior concentração de Co2+, sob corrente pulsada simples

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the importance of energy efficiency and the use of alternative energy sources, facing to the increasing energy demand and the concomitant economic, social and environmental restrictions imposed by society. In this work, alternative sources are illustrated by photovoltaic, micro turbines and fuel cells microgeneration systems. Energy efficiency is presented by direct current microgrids because its uses excludes the conversions of direct current (DC) to alternating current (AC) losses made with the intention of injecting energy into the electric grid and then the inverse conversion, AC to DC, in order to feed residential loads. The object of this paper is to analyze a case study and evaluates the costs and technical feasibility of a Project that combines a DC microgrid and a microgeneration system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a comparative study based on literature and examples in the literature, the two main technologies for the transmission of electricity at high voltage: alternate current transmission and direct current transmission. Inside the direct current transmission will be shown two technologies currently employed, transmission by current source and transmission by voltage source, contributing to a better understanding of them. The ultimate goal is to provide a text for consultation to identify key characteristics that influence the choice of future transmission lines

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work deals with the analytical, computational and experimental study of phenomena related to the Eddy current induction in low permeability means for embedded electromagnetic braking systems applications. The phenomena of forces generation in opposing to the variation of stationary magnetic flux produced by DC power supplies, set in motion by the application of an external propulsive force are addressed. The study is motivated by search for solving the problem of speed control of PIGs used to verifying and maintaining pipelines, and is led based on the analytical models synthesis, validated by means of computer simulations in Finite Elements environment, provided by engineering support software; and with experimental tests conducted under controlled laboratory conditions. Finally, a damping systems design methodology based on analyzes results conducted throughout the study is presented

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims to show practical and effectiveexperiencesfor lessons Industrial Automation Laboratory taught inundergraduate degreein ElectricalEngineering from the University Júlio MesquitaFilho - UNESP, Guaratinguetá. Experiments carriedsimulatecontrol and drive systems of electric three phase induction motors (MIT)widely usedinindustries. The experiments simulate a manufacturing environment where there isa need to control the activation and continuous operation ofelectricmotors. Seven experimentsthat simulatethe firing of electrical motors through a controlsystem, a driver along with asimulator loads coupled to the electric motor was developed. Experiments usinga Programmable Logic Controller (PLC) as acontroller,an inverter frequencyasdriver, and MagneticBrake, as simulatorengine loads . The experiments were divided accordingto the speed reference signal used fordrivingand operating the electric motor: digital and analog. The first five experiments performing the drive control and operation of the electric motor via digital signals. The sixth and seventh experiments using an analog signal as a reference speed for the electric motor

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nesta dissertação é mostrada experimentalmente a existência de modos ressonantes em servomotores de corrente contínua sem núcleo de ferro. Até onde se sabe, não já publicações ou documentos técnicos de fabricantes que relatam esse efeito neste tipo de motor. Foi observado também que a frequência da ressonância é variável e que possivelmente depende da temperatura interna do motor. Conforme e mostrado em simulações técnicas tradicionais para o controle de motores podem não ser eficazes para lidar com esses modos ressonantes. Com o objetivo de amortecer a ressonância e obter o controle de velocidade e posição desses motores, são desenvolvidos controladores por modo deslizante baseados em funções de chaveamento obtidas por observadores de alto ganho. Esse controle e robusto a incertezas paramétricas e perturbações. Com o auxílio de simulações são mostrados os pontos fortes e limitações de cada um dos controladores.