993 resultados para Chromium(VI) determination
Resumo:
Screen-printed carbon electrode (SPCE) modified with poly-L-histidine film can be successfully applied for chromium(VI) determination based on its pre-concentration. Optimum adherence and stability of the POIY-L-histidine film was obtained by direct addition of PH solution 1% (w/v) on the electrode surface, followed by heating at 80 degrees C during 5 min. Linear response range, sensitivity and limit of detection were 0. 1-150 [mu mol L-1, 4. 13 LA mu mol L` and 0.046 mu mol L-1. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation, was measured as 3.2% for 10 experiments in 40 mu mol L-1 using the same electrode and 4.0% using screen-printed electrode as disposable sensor, respectively. The voltammetric sensor was applied to determination of Cr(VI) and indirect determination of Cr(III) in wastewater samples previously treated by a leather dyeing industry and the average recovery for these samples was around 97%. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
Titanium(IV) oxide, coated on the surface of silica gel (surface area, 308 m2 g-1; amount of Ti(IV) per gram of modified silica gel, 1.8 x 10(-3) mol), was used to adsorb CrO4(2-) ions from acidic solutions. The exchange capacity increased at lower pH values and was affected to some extent by the acid used. The material was used to preconcentrate Cr(VI) from 0.5 ppm solutions of chromate very efficiently and virtually 100% recovery was achieved in every instance.
Resumo:
A rapid and sensitive method for separation and determination of Cr(VI) and Cr(III) in bottom mud of lake by flow injection on-line preconcentrtion system and GFAAS was developed. The available Cr(VI) and Cr(III) were extracted by HOAc or EDTA + NH4 NO3 and adsorbed simultaneously by an anion and a cation resin microclummn and then eluted simultaneously by 2 mol/L NH4 NO3 + 0.05 mol/L ascorbate and 2 mol/L H2SO4, respectively. The elution was performed for 50 s after adsorption for 2 min, and the efficiencies of elution were 85.4% - 94.8% and 96.7% - 106% for Cr(VI) and Cr(M) respectively. The detection limits of the method were 0.9 mu g/L and 2.7 mu g/L with relative standard deviations of 3.5% and 6.4% for the determination of Cr(VI) and Cr(III) in sample, respectively.
Resumo:
A new chemiluminescence(CL) system for the determination of ascorbic acid has been established. By the fast reduction reaction between chromium(VI) and ascorbic acid, chromium(M was generated to react with luminol and hydrogen peroxide in alkaline aqueous solution and hydrogen peroxide to produce CL. The CL emission intensity was correlated with ascorbic acid concentration in the range 8.0 x 10(-9) to 1.6 x 10(-4) mol/L, and the detection limit was 8.0 x 10(-9) mol/L ascorbic acid. The relative standard deviation (n = 11) for 1.0 x 10(-6) mol/L ascorbic acid is 0.9%. The method has been applied to the determination of ascorbic acid in vitamin C tablets with satisfactory results.
Resumo:
A flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total chromium [after the on-line oxidation of Cr(III) by Ce(IV)] are sequentially determined. Cr(III) is obtained by difference. Under the experimental conditions described, the calibration graphs are linear up to 2 μg mh1 of Cr(VI) and 4 μg ml-1 of Cr(III). The detection limits found were 18 ng ml -1 for Cr(VI) and 55 ng ml-1 for Cr(III), at a signal to noise ratio of 3. The common interfering elements in the Cr(VI) - DPC reaction were investigated under dynamic FIA conditions. The FIA method was also compared with the conventional spectrophotometric procedure.
Resumo:
The present work reports the use of a screen-printed carbon electrode (SPCE) modified by poly-L-histidine film to determine chromium (VI). Stable films can be formed by direct addition of PH solution 1 % (w/v) on the electrode surface, followed by heating at 80°C during 5 min. Calibration curves can be constructed for Cr(VI) from 1.0 × 10-5 mol L-1 to 7.0 × 10-5 mol L-1 Cr (VI) in acetate buffer pH 4 using a preconcentration step of 60s at open circuit potential. A relative standard deviation of 3.2% was for five determination of 4.0 × 10 -5 mol L-1 Cr (VI). The method was successful applied to determination of Cr(VI) in wastewater samples from a leather dyeing industry. copyright The Electrochemical Society.
Resumo:
Due to the potentially adverse effects of the chromium (VI) on the human health and also on the environment, the quantitative determination of Cr(VI) is of particular interest. This work herein reports a facile, selective and rapid colorimetric determination of Cr(VI) based on the peroxidase substrate-2,2'-azino-bis(3-ethylbenzo-thiazoline-6-sulfonic acid) diammonium salt (ABTS) as the color developing agent. ABTS, which was usually acted as peroxidase substrate for the enzyme linked immunosorbent assay, is used here for the first time to fabricate the "signal-on" colorimetric Assay for Cr(VI).
Resumo:
Composite TiO2/acid leached serpentine tailings (AST) were synthesized through the hydrolysis–deposition method and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energydispersive X-ray spectrometry (EDS), Fourier-transform infrared spectroscopy (FT-IR), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and surface area measurement (BET). The XRD analysis showed that TiO2 coated on the surface of acid leached serpentine tailings was mixed crystal phases of rutile and anatase, the grain size of which is 10–30 nm. SEM, TEM, and EDS analysis exhibited that nano-TiO2 particles were deposited on the surface and internal cavities of acid leaching serpentine tailings. The XPS and FT-IR analysis demonstrated that the coating process of TiO2 on AST was a physical adsorption process. The large specific surface area, porous structure, and plentiful surface hydroxyl group of TiO2/AST composite resulted in the high adsorption capacity of Cr(VI). The experimental results demonstrated that initial concentration of Cr(VI), the amount of the catalyst, and pH greatly influenced the removal efficiency of Cr(VI). The removal kinetics of Cr(VI) at a relative low initial concentration was fitted well with Langmuir–Hinshelwood kinetics model with R2 value of about unity. The asprepared composites exhibited strong adsorption and photocatalytic capacity for the removal of Cr(VI), and the possible photocatalytic reduction mechanism was studied. The photodecomposition of Cr(VI) was as high as 95% within 2 h, and the reusability of the photocatalysis was proven.
Resumo:
The formation of readily recoverable and reusable organic semiconducting Cu- and AgTCNQ (TCNQ=7,7,8,8-tetracyanoquinodimethane) microstructures decorated with Pt and Pd metallic nanoparticles is described for the effective reduction of CrVI ions in aqueous solution at room temperature using both formic acid and an environmentally friendly thiosulfate reductant. The M-TCNQ (M=metal) materials were formed by electrocrystallisation onto a glassy carbon surface followed by galvanic replacement in the presence of H2PtCl6 or PdCl2 to form the composite material. It was found that loading of the surface with nanoparticles could easily be controlled by changing the metal salt concentration. Significantly, the M-TCNQ substrates facilitated the formation of well-isolated metal nanoparticles on their surfaces under appropriate galvanic replacement conditions. The semiconductor–metal nanoparticle combination was also found to be critical to the catalyst performance, wherein the best-performing material was CuTCNQ modified by well-isolated Pt nanoparticles with both formic acid and thiosulfate ions as the reductant.
Resumo:
Cancer du poumon associé à l’exposition au nickel, au chrome VI et au cadmium dans le milieu de travail utilisant deux études populationnelles cas-témoins à Montréal. Au début des années 1990, le nickel, le chrome VI et le cadmium ont été classés en tant qu’agents cancérigènes de classe 1 par le CIRC (Centre International de Recherche sur le Cancer). Cependant, les résultats des études ayant permis la classification de ces métaux n’ont pas toujours été reproduits, et d’importantes questions demeurent quant aux effets de ces métaux à de faibles niveaux d’exposition. Un plus grand nombre de recherches empiriques est donc nécessaire afin de réaffirmer la cancérogénicité de ces agents, et d’identifier les circonstances dans lesquelles ils peuvent être néfastes. L'objectif de cette étude était d'explorer la relation entre l’exposition à un des métaux (soit le nickel, le chrome VI, ou le cadmium) et les risques subséquents de développer un cancer du poumon chez des travailleurs provenant de différents milieux de travail qui sont exposés à ces métaux à de différents degrés. Deux études cas-témoins de base populationnelle menées à Montréal ont fourni les données nécessaires pour examiner la cancérogénicité de ces métaux. La première étude était menée entre 1979 et 1986 chez des hommes âgés de 35 à 70 ans ayant un cancer dans l’un de 19 sites anatomiques de cancer sélectionnés. La seconde étude était menée entre 1996 et 2001 chez des hommes et des femmes âgés de 35 à 75 ans, avec un diagnostic de tumeur maligne au poumon. Dans ces deux études, les cas ont été recensés dans tous les hôpitaux de l'île de Montréal, tandis que les contrôles populationnels appariés par âge et stratifiés par sexe, ont été sélectionnés des listes électorales. Une entrevue avec chaque sujet a permis d'obtenir un historique d'emploi détaillé ainsi que des informations précises sur les facteurs de risques socio-économiques et personnels. Les descriptions de poste ont été évaluées par une équipe d'experts chimistes et hygiénistes afin de déterminer si le sujet a été exposé à chaque agent, et pour mesurer à la fois la concentration et la durée de chaque exposition, ainsi que l’exposition cumulative tout au long de la vie de chaque participant. Pour déterminer si une exposition à l’un des trois métaux en cause était associée à une augmentation de l'incidence du cancer du poumon, des données ont été analysées par régression logistique : des ajustements ont été effectués pour des facteurs de confusion pertinents incluant un historique détaillé du tabagisme. Des mesures catégoriques d'exposition cumulée ont été également analysées, ainsi que la modification des effets par le tabagisme. Les deux études ont été analysées séparément, puis par la suite combinées afin d'augmenter la puissance statistique. Les niveaux d'exposition mesurés dans cette population ne semblaient pas poser un excès de risque de cancer du poumon pour les travailleurs exposés au chrome VI. Cependant, ceux qui ont été exposés au nickel ont subi une augmentation significative du risque, et ce, quel que soit leur niveau d'exposition. Le risque de développer un cancer du poumon suite à une exposition au cadmium était élevé, mais pas de manière significative. Pour chacun des trois métaux, le risque de cancer du poumon était très élevé parmi les non-fumeurs, mais pas parmi les fumeurs. L’effet combiné du tabagisme et de l’exposition aux métaux était compatible avec un excès de risque additif. Cependant, les intervalles de confiance dans cette étude tendaient à être larges, et une faiblesse de puissance statistique peut limiter l’interprétation de certains résultats. Cette étude est unique dans la mesure où elle a fourni des preuves empiriques sur les risques de développer le cancer du poumon liés aux faibles niveaux d’exposition au nickel, au chrome VI, ou au cadmium provenant de divers contextes de travail. Dans la plupart des autres études, la majorité des expositions pertinentes n’ont pas été bien contrôlées. À l'inverse, cette étude a bénéficié de la collecte et de la disponibilité d'information détaillée concernant le tabagisme et d’autres facteurs de risque. Les résultats de cette étude ont d'importantes conséquences pour la santé publique, tant au niveau de la détermination des risques pour les travailleurs actuellement exposés à ces métaux, qu'au niveau de l’évaluation des risques pour la population en général, elle-même exposée à ces métaux par le biais de la pollution et de la fumée de cigarette. Cette analyse contribuera fort probablement à une réévaluation par le CIRC de la cancérogénicité de ces métaux. L'exploration de la relation entre les risques de cancer du poumon et l'exposition au nickel, au chrome VI et au cadmium est donc opportune et pertinente.
Resumo:
A comparative systematic study of the CrO2F2 compound has been performed using different conventional ab initio methodologies and density functional procedures. Two points have been analyzed: first, the accuracy of results yielded by each method under study, and second, the computational cost required to reach such results. Weighing up both aspects, density functional theory has been found to be more appropriate than the Hartree-Fock (HF) and the analyzed post-HF methods. Hence, the structural characterization and spectroscopic elucidation of the full CrO2X2 series (X=F,Cl,Br,I) has been done at this level of theory. Emphasis has been given to the unknown CrO2I2 species, and specially to the UV/visible spectra of all four compounds. Furthermore, a topological analysis in terms of charge density distributions has revealed why the valence shell electron pair repulsion model fails in predicting the molecular shape of such CrO2X2 complexes
Resumo:
A strain of Staphylococcus isolated by Dr. Fekete at the Sandia National Laboratory toxic metal dumping site in Sandia, New Mexico. has been found to reduce toxic Cr(VI) to the less toxic Cr(IlI) state. We have ascertained the environmental parameters for optimal bacterial growth and Cr(VI) reduction. This knowledge may be employed in a comprehensive bioremediation scheme designed to accelerate natural reparation of that Sandia ecosystem. In addition we have investigated the genetic and enzymatic basis for this Cr(VI) reducing ability. This information may allow us to create more effective bioremediation schemes based on the comprehensive knowledge of enzyme and gene function. Preliminary investigations have been carried out toward this end which may serve as the basis for a more thorough investigation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The potential to remove chromium(VI) from aqueous solutions through biosorption using coffee husk was investigated. The effects of pH, contact time, initial concentration and adsorbent dosage on the adsorption of Cr(VI) were studied. The data obeyed Langmuir and Freundlich adsorption isotherms. The Langmuir adsorption capacity was found to be 44.95 mg/g. The Freundlich constants K-f and n were 1.027 mg/g (litre/mg)(n)] and 1.493, respectively. Desorption studies indicated the removal of 60% of the hexavalent chromium. Infrared spectral studies revealed the presence of functional groups, such as hydroxyl and carboxyl groups, on the surface of the biomass, which facilitates biosorption of Cr(VI).