989 resultados para Central corneal thickness,
Resumo:
Objective: The aim of this study was to verify the influence of prostaglandin analogs and prostamide on central corneal thickness (CCT). Methods: A prospective analysis was done of CCT in glautomatous patients submitted to monotherapy with prostaglandin analogs (latanoprost 0.005% or travoprost 0.004%) or prostamide (bimatoprost 0.03%) during an 8-week period. A control group of patients without any ocular medication was also evaluated. CCT measurements were performed with a commercially available ultrasound pachymeter. A total of 73 patients were included in this study. Mean age was 68.5 +/- 9.2 (range, 48-85) years old. Results: A statistically significant reduction in CCT was observed in all groups, except the control group (n = 21): Bimatoprost 0.03% group (n = 21): 544.41 +/- 35.4 vs. 540.35 +/- 35.9 mu m (P = 0.039); travoprost 0.004% group (n = 17): 538.47 +/- 32.0 vs. 532.25 +/- 30.4 mu m (P = 0.009); latanoprost 0.005% group (n = 14): 548.57 +/- 32.4 vs. 543.88 +/- 35.6 mu m (P = 0.036). Conclusion: Topical therapy with prostaglandin analogs and bimatoprost is associated with CCT reduction over a period of at least 8 weeks.
Resumo:
Purpose: To compare the central corneal thickness (CCT) of patients with systemic sclerosis (SSc) and control subjects. Methods: The study group comprised 37 consecutive patients with SSc, and the control group comprised 23 healthy individuals similar in age and sex. CCT value was measured by ultrasound pachymetry. Results: In the SSc group, the mean CCT in the right eye was 534.9 +/- 33.5 mu m and 536.9 +/- 32.4 mu m in the left eye. In the control group, the mean CCT was 533.0 +/- 32.9 mu m in the right eye and 533.1 +/- 33.6 mu m in the left eye. The mean CCT was not significantly different in the SSc group compared with the control group for both the right (P = 0.83) and left (P = 0.67) eyes. Conclusions: CCT measurements do not significantly differ in patients with SSc compared with healthy control subjects.
Resumo:
Objective: To determine the values of, and study the relationships among, central corneal thickness (CCT), intraocular pressure (IOP), and degree of myopia (DM) in an adult myopic population aged 20 to 40 years in Almeria (southeast Spain). To our knowledge this is first study of this kind in this region. Methods: An observational, descriptive, cross-sectional study was done in which a sample of 310 myopic patients (620 eyes) aged 20 to 40 years was selected by gender- and age-stratified sampling, which was proportionally fixed to the size of the population strata for which a 20% prevalence of myopia, 5% epsilon, and a 95% confidence interval were hypothesized. We studied IOP, CCT, and DM and their relationships by calculating the mean, standard deviation, 95% confidence interval for the mean, median, Fisher’s asymmetry coefficient, range (maximum, minimum), and the Brown-Forsythe’s robust test for each variable (IOP, CCT, and DM). Results: In the adult myopic population of Almeria aged 20 to 40 years (mean of 29.8), the mean overall CCT was 550.12 μm. The corneas of men were thicker than those of women (P = 0.014). CCT was stable as no significant differences were seen in the 20- to 40-year-old subjects’ CCT values. The mean overall IOP was 13.60 mmHg. Men had a higher IOP than women (P = 0.002). Subjects over 30 years (13.83) had a higher IOP than those under 30 (13.38) (P = 0.04). The mean overall DM was −4.18 diopters. Men had less myopia than women (P < 0.001). Myopia was stable in the 20- to 40-year-old study population (P = 0.089). A linear relationship was found between CCT and IOP (R2 = 0.152, P ≤ 0.001). CCT influenced the IOP value by 15.2%. However no linear relationship between DM and IOP, or between CCT and DM, was found. Conclusions: CCT was found to be similar to that reported in other studies in different populations. IOP tends to increase after the age of 30 and is not accounted for by alterations in CCT values.
Resumo:
Objective: To determine the values of, and study the relationships among, central corneal thickness (CCT), intraocular pressure (IOP), and degree of myopia (DM) in an adult myopic population aged 20 to 40 years in Almeria (southeast Spain). To our knowledge this is first study of this kind in this region. Methods: An observational, descriptive, cross-sectional study was done in which a sample of 310 myopic patients (620 eyes) aged 20 to 40 years was selected by gender- and age-stratified sampling, which was proportionally fixed to the size of the population strata for which a 20% prevalence of myopia, 5% epsilon, and a 95% confidence interval were hypothesized. We studied IOP, CCT, and DM and their relationships by calculating the mean, standard deviation, 95% confidence interval for the mean, median, Fisher’s asymmetry coefficient, range (maximum, minimum), and the Brown-Forsythe’s robust test for each variable (IOP, CCT, and DM). Results: In the adult myopic population of Almeria aged 20 to 40 years (mean of 29.8), the mean overall CCT was 550.12 μm. The corneas of men were thicker than those of women (P = 0.014). CCT was stable as no significant differences were seen in the 20- to 40-year-old subjects’ CCT values. The mean overall IOP was 13.60 mmHg. Men had a higher IOP than women (P = 0.002). Subjects over 30 years (13.83) had a higher IOP than those under 30 (13.38) (P = 0.04). The mean overall DM was −4.18 diopters. Men had less myopia than women (P < 0.001). Myopia was stable in the 20- to 40-year-old study population (P = 0.089). A linear relationship was found between CCT and IOP (R2 = 0.152, P ≤ 0.001). CCT influenced the IOP value by 15.2%. However no linear relationship between DM and IOP, or between CCT and DM, was found. Conclusions: CCT was found to be similar to that reported in other studies in different populations. IOP tends to increase after the age of 30 and is not accounted for by alterations in CCT values.
Resumo:
Our objective was to study the effect of dorzolamide on corneal hydration in an 18-week controlled experiment using ultrasonic pachymetry. Twenty-eight male rabbits were divided randomly into four groups. The 7 rabbits in each group received eye drops containing either 2% (w/v) dorzolamide or placebo in their right eye, or in their left eye. The 2% dorzolamide rabbits were treated every 8 h. Fellow eyes are defined as eyes which did not receive either dorzolamide or placebo. The study was blind for both the person who applied the drug and the one who performed the pachymetry. The effect of treatments is reported on the basis of the percentage of pachymetric variation compared to the measurement made before drug application. There was no significant difference (P = 0.061) in pachymetric variation between dorzolamide (-4.42 ± 11.71%) and placebo (2.48 ± 9.63%). However, there was a significant difference (P = 0.0034) in pachymetric variation between the dorzolamide fellow eyes (-7.56 ± 10.50%) and the placebo (-4.42 ± 11.71%). In conclusion, dorzolamide did not increase the corneal thickness in rabbits.
Resumo:
OBJECTIVE To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high-speed optical low-coherence reflectometer (OLCR) mounted on a slit lamp. ANIMALS STUDIED Twelve male chicks (Gallus gallus domesticus). Procedures Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1-day-old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky's solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). RESULTS Central corneal thickness measurements using OLCR in 1-day-old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky's solution (P = 0.0005). In eyes with additional injection of Karnovsky's fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. CONCLUSION Optical low-coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.
Resumo:
BACKGROUND/AIMS: Rebound tonometry (RT) is performed without anaesthesia with a hand held device. The primary aim was to compare RT with Goldmann applanation tonometry (GAT) and to correlate with central corneal thickness (CCT). The secondary aim was to prove tolerability and practicability of RT under "study conditions" and "routine practice conditions." METHODS: In group 1 (52 eyes/28 patients), all measurements were taken by the same physician, in the same room and order: non-contact optical pachymetry, RT, slit lamp inspection, GAT. Patients were questioned about discomfort or pain. In group 2 (49 eyes/27 patients), tonometry was performed by three other physicians during routine examinations. RESULTS: RT was well tolerated and safe. Intraocular pressure (IOP) ranged between 6 mm Hg and 48 mm Hg. No different trends were found between the groups. RT tended to give slightly higher readings: n = 101, mean difference 1.0 (SD 2.17) mm Hg; 84.1% of RT readings within plus or minus 3 mm Hg of GAT; 95% confidence interval in the Bland-Altman analysis -3.2 mm Hg to +5.2 mm Hg. Both RT and GAT showed a weak positive correlation with CCT (r2 0.028 and 0.025, respectively). CONCLUSIONS: RT can be considered a reliable alternative for clinical screening and in cases where positioning of the head at the slit lamp is impossible or topical preparations are to be avoided.
Resumo:
PURPOSE To determine whether the scleral stroma is affected as much as the corneal stroma in keratoconus. SETTING University Eye Clinic, Bern, Switzerland. DESIGN Comparative case-control study. METHODS Eyes with keratoconus (keratoconus group) and eyes of age-, sex-, and axial length-matched controls (control group) were analyzed. Corneal videokeratometry and pachymetry were performed using a Scheimpflug tomographer (Pentacam). For measurements of the peripheral cornea and the anterior sclera, a spectral-domain anterior segment optical coherence tomography device (Spectralis) was used. RESULTS The study group comprised 51 eyes and the control group, 50 eyes. The mean central corneal thickness in the keratoconus group was statistically significantly lower than in the control group (447.8 μm ± 57.8 [SD] versus 550.5 ± 35.5 μm) (P < .0001). No significant difference in the mean anterior scleral thickness was found between the keratoconus group and the control group (479.1 ± 43.7 μm versus 474.2 ± 43.0 μm) (P =.57). CONCLUSION Although corneal thinning was observed in keratoconus patients, the anterior scleral stroma thickness in these patients seemed to be similar to that in healthy control eyes.
Resumo:
Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.
Resumo:
Purpose. The purpose of this study was to investigate the influence of corneal topography and thickness on intraocular pressure (IOP) and pulse amplitude (PA) as measured using the Ocular Blood Flow Analyzer (OBFA) pneumatonometer (Paradigm Medical Industries, Utah, USA). Methods. 47 university students volunteered for this cross-sectional study: mean age 20.4 yrs, range 18 to 28 yrs; 23 male, 24 female. Only the measurements from the right eye of each participant were used. Central corneal thickness and mean corneal radius were measured using Scheimpflug biometry and corneal topographic imaging respectively. IOP and PA measurements were made with the OBFA pneumatonometer. Axial length was measured using A-scan ultrasound, due to its known correlation with these corneal parameters. Stepwise multiple regression analysis was used to identify those components that contributed significant variance to the independent variables of IOP and PA. Results. The mean IOP and PA measurements were 13.1 (SD 3.3) mmHg and 3.0 (SD 1.2) mmHg respectively. IOP measurements made with the OBFA pneumatonometer correlated significantly with central corneal thickness (r = +0.374, p = 0.010), such that a 10 mm change in CCT was equivalent to a 0.30 mmHg change in measured IOP. PA measurements correlated significantly with axial length (part correlate = -0.651, p < 0.001) and mean corneal radius (part correlate = +0.459, p < 0.001) but not corneal thickness. Conclusions. IOP measurements taken with the OBFA pneumatonometer are correlated with corneal thickness, but not axial length or corneal curvature. Conversely, PA measurements are unaffected by corneal thickness, but correlated with axial length and corneal radius. These parameters should be taken into consideration when interpreting IOP and PA measurements made with the OBFA pneumatonometer.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background/aims To compare two intraocular irrigating solutions, Balanced Salt Solution Plus (BSS Plus) versus Lactated Ringer`s (Ringer), for the preservation of corneal integrity after phacoemulsification. Methods 110 patients undergoing phacoemulsification were randomised to either BSS Plus (n = 55) or Ringer (n = 55) as the irrigating solution. Patients were examined at baseline and at 1, 8, 15, 30 and 60 days postoperatively. Evaluations included specular microscopy to evaluate endothelial cell density (ECD) and endothelial cell size variability (CV), and corneal pachymetry for central corneal thickness (CCT) measurement. Results Groups were well balanced regarding baseline ECD, CV and CCT (p>0.05). There was no statistically significant difference between ECD reduction in group BSS Plus 13.1 +/- 2.0% and Ringer 9.2 +/- 1.9% (p<0.05) at day 60 or in any study visit. There was no statistically significant difference between CV increase in group BSS Plus 23.0 +/- 3.0% and Ringer 20.2 +/- 4.0% (p<0.05) at day 60 or in any study visit. CCT was significantly increased (p<0.05) at 1, 8, 15 and 30 days postoperatively, returning to baseline at 60 days in both groups. There was no significant difference in CCT increase in both groups at any visit. Interestingly, there were statistically significant correlations between ECD loss and phacoemulsification time (p<0.0001) and ECD loss and irrigation solution volume (p<0.0001) in the Ringer group, but not in the BSS Plus group. Conclusions Ringers solution was similar to BSS Plus for corneal preservation in atraumatic cataract surgery. However, our study demonstrates that there is a trend towards lower postoperative endothelial cell density for surgeries with longer phacoemulsification time and higher irrigation volumes if Ringer is used.
Resumo:
Purpose: Crosslinking of corneal collagen with riboflavin and ultraviolet-A irradiation (CXL) induces crosslinks within and between collagen fibers. CXL increases corneal biomechanical and biochemical stability and is currently used clinically to treat keratectasia. CXL also significantly reduces the stromal swelling capacity. We investigated whether a modified CXL treatment protocol would be beneficial in early Fuchs' dystrophy with various degrees of corneal edema and diurnal variations in visual acuity. Methods: CXL was performed as published previously with the following modification: in cases where the stroma was thicker than 450 µm after abrasion and 30 minutes of instillation of isoosmolar riboflavin solution, glycerol 70% solution was applied every 5 seconds for two minutes, and central corneal thickness (CCT) was measured using ultrasound pachymetry. Glycerol 70% solution was administered repeatedly until the target corneal thickness of 370-430 µm was reached. During irradiation, CCT was monitored by ultrasound pachymetry every five minutes and glycerol 70% solution was applied, if necessary. Results: Three eyes in two patients were treated using the modified CXL protocol. Representative case: a 50-year-old woman with Fuchs' dystrophy and a history of 3 years of diurnal visual fluctuations was referred to us in March 2008. Preoperative best spectacle-corrected visual acuity (BSCVA) was 20/50. We performed modified CXL in the left eye. At one month after CXL, Scheimpflug analysis of CCT showed a reduction of more than 100 µm, and the Corneal Thickness Spatial Profile (CTSP) and Percentage of Increase in Thickness (PIT) showed a regularization of the "flattening" typical for Fuchs' dystrophy. Accordingly, diurnal analysis of corneal thickness showed a distinct postoperative reduction in CCT at all time points measured. At one month after CXL, the patient reported a reduction of diurnal visual fluctuations and we measured an increase in BSCVA to 20/32. The patient showed stable topographical and visual acuity at the three months follow-up. Conclusions: We saw a distinct reduction in CCT, an improvement of the corneal thickness spatial profile (CTSP) and an increase in BSCVA at one month after treatment, which remained stable at the three months follow-up. Patients with early Fuchs' dystrophy and disturbing diurnal visual fluctuations represent a novel application for CXL. Although CXL may not prevent the outcome of the dystrophy, it may increase the patients' visual comfort until keratoplasty becomes necessary.
Resumo:
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.