671 resultados para Cardiopulmonary resuscitation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The current study was conducted to determine levels of cardiac knowledge and cardiopulmonary resuscitation (CPR) training in older people in Queensland, Australia.---------- Methods: A telephone survey of 4490 Queensland adults examined respondents’ knowledge of coronary heart disease (CHD) risk factors, knowledge of heart attack symptoms, knowledge of the local emergency telephone number, as well as respondents’ rates and recency of training in CPR.---------- Results: Older participants, aged 60 years and over, were approximately one and a half times more likely than the 30–39 year-old reference group to have limited knowledge of heart disease risk factors (OR = 1.53), and low knowledge of heart attack symptoms (OR = 1.60). Knowledge of the local emergency telephone number also decreased with age. Older participants had significantly lower rates of training in CPR, with almost three quarters (71.7%) reporting that they had never been trained. Older people who had completed CPR training were significantly less likely to have done so recently.---------- Conclusions: Cardiac knowledge levels and CPR training rates in older Queensland persons were lower than those found in the younger population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The national resuscitation guidelines were published in Finland in 2002 and are based on international guidelines published in 2000. The main goal of the national guidelines, available on the Internet free of charge, is early defibrillation by nurses in an institutional setting. Aim: To study possible changes in cardiopulmonary resuscitation (CPR) practices, especially concerning early defibrillation, nurses and students attitudes of guideline implementation and nurses and students ability to implement the guideline recommendations in clinical practices after publication of the Current Care (CC) guidelines for CPR 2002. Material and methods: CPR practices in Finnish health centres; especially concerning rapid defibrillation programmes, as well as the implementation of CC guidelines for CPR was studied in a mail survey to chief physicians of every health centre in Finland (Study I). The CPR skills using an automated external defibrillator (AED) were compared in a study including Objective stuctured clinical examination (OSCE) of resuscitation skills of nurses and nursing students in Finnish and Swedish hospital and institution (Studies II, III). Attitudes towards CPR-D and CPR guidelines among medical and nursing students and secondary hospital nurses were studied in surveys (Studies IV, V). The nurses receiving different CPR training were compared in a randomized trial including OSCE of CPR skills of nurses in Finnish Hospital (Study VI). Results: Two years after the publication, 40.7% of Finnish health centres used national resuscitation guidelines. The proportion of health centres having at least one AED (66%) and principle of nurse-performed defibrillation without the presence of a physician (42%) had increased. The CPR-D training was estimated to be insufficient regarding basic life support and advanced life support in the majority of health centres (Study I). CPR-D skills of nurses and nursing students in two specific Swedish and Finnish hospitals and institutions (Study II and III) were generally inadequate. The nurses performed better than the students and the Swedish nurses surpassed the Finnish ones. Geriatric nurses receiving traditional CPR-D training performed better than those receiving an Internet-based course but both groups failed to defibrillate within 60 s. Thus, the performance was not satisfactory even two weeks after traditional training (Study VI). Unlike the medical students, the nursing students did not feel competent to perform procedures recommended in the cardiopulmonary resuscitation guidelines including the defibrillation. However, the majority of nursing students felt confident about their ability to perform basic life support. The perceived ability to defibrillate correlated significantly with a positive attitude towards nurse-performed defibrillation and negatively with fear of damaging the patient s heart by defibrillation (Study IV). After the educational intervention, the nurses found their level of CPR-D capability more sufficient than before and felt more confident about their ability to perform defibrillation themselves. A negative attitude toward defibrillation correlated with perceived negative organisational attitudes toward cardiopulmonary resuscitation guidelines. After CPR-D education in the hospital, the majority (64%) of nurses hesitated to perform defibrillation because of anxiety and 27 % hesitated because of fear of injuring the patient. Also a negative personal attitude towards guidelines increased markedly after education (Study V). Conclusions: Although a significant change had occurred in resuscitation practices in primary health care after publication of national cardiopulmonary resuscitation guidelines the participants CPR-D skills were not adequate according to the CPR guidelines. The current way of teaching is unlikely to result in participants being able to perform adequate and rapid CPR-D. More information and more frequent training are needed to diminish anxiety concerning defibrillation. Negative beliefs and attitudes toward defibrillation affect the nursing students and nurses attitudes toward cardiopulmonary resuscitation guidelines. CPR-D education increased the participants self-confidence concerning CPR-D skills but it did not reduce their anxiety. AEDs have replaced the manual defibrillators in most institutions, but in spite of the modern devices the anxiety still exists. Basic education does not provide nursing students with adequate CPR-D skills. Thus, frequent training in the workplace has vital importance. This multi-professional program supported by the administration might provide better CPR-D skills. Distance learning alone cannot substitute for traditional small-group learning, tutored hands-on training is needed to learn practical CPR-D skills. Standardized testing would probably help controlling the quality of learning. Training of group-working skills might improve CPR performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Survival from out-of-hospital cardiac arrest depends largely on two factors: early cardiopulmonary resuscitation (CPR) and early defibrillation. CPR must be interrupted for a reliable automated rhythm analysis because chest compressions induce artifacts in the ECG. Unfortunately, interrupting CPR adversely affects survival. In the last twenty years, research has been focused on designing methods for analysis of ECG during chest compressions. Most approaches are based either on adaptive filters to remove the CPR artifact or on robust algorithms which directly diagnose the corrupted ECG. In general, all the methods report low specificity values when tested on short ECG segments, but how to evaluate the real impact on CPR delivery of continuous rhythm analysis during CPR is still unknown. Recently, researchers have proposed a new methodology to measure this impact. Moreover, new strategies for fast rhythm analysis during ventilation pauses or high-specificity algorithms have been reported. Our objective is to present a thorough review of the field as the starting point for these late developments and to underline the open questions and future lines of research to be explored in the following years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quality of cardiopulmonary resuscitation (CPR) improves through the use of CPR feedback devices. Most feedback devices integrate the acceleration twice to estimate compression depth. However, they use additional sensors or processing techniques to compensate for large displacement drifts caused by integration. This study introduces an accelerometer-based method that avoids integration by using spectral techniques on short duration acceleration intervals. We used a manikin placed on a hard surface, a sternal triaxial accelerometer, and a photoelectric distance sensor (gold standard). Twenty volunteers provided 60 s of continuous compressions to test various rates (80-140 min(-1)), depths (3-5 cm), and accelerometer misalignment conditions. A total of 320 records with 35312 compressions were analysed. The global root-mean-square errors in rate and depth were below 1.5 min(-1) and 2 mm for analysis intervals between 2 and 5 s. For 3 s analysis intervals the 95% levels of agreement between the method and the gold standard were within -1.64-1.67 min(-1) and -1.69-1.72 mm, respectively. Accurate feedback on chest compression rate and depth is feasible applying spectral techniques to the acceleration. The method avoids additional techniques to compensate for the integration displacement drift, improving accuracy, and simplifying current accelerometer-based devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

nterruptions in cardiopulmonary resuscitation (CPR) compromise defibrillation success. However, CPR must be interrupted to analyze the rhythm because although current methods for rhythm analysis during CPR have high sensitivity for shockable rhythms, the specificity for nonshockable rhythms is still too low. This paper introduces a new approach to rhythm analysis during CPR that combines two strategies: a state-of-the-art CPR artifact suppression filter and a shock advice algorithm (SAA) designed to optimally classify the filtered signal. Emphasis is on designing an algorithm with high specificity. The SAA includes a detector for low electrical activity rhythms to increase the specificity, and a shock/no-shock decision algorithm based on a support vector machine classifier using slope and frequency features. For this study, 1185 shockable and 6482 nonshockable 9-s segments corrupted by CPR artifacts were obtained from 247 patients suffering out-of-hospital cardiac arrest. The segments were split into a training and a test set. For the test set, the sensitivity and specificity for rhythm analysis during CPR were 91.0% and 96.6%, respectively. This new approach shows an important increase in specificity without compromising the sensitivity when compared to previous studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth. Materials and Methods We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer's hands and the manikin's chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor. Results The median (IQR) percent error was 5.9% (2.8-10.3), 6.3% (2.9-11.3), and 2.5% (1.2-4.4) for depth and 1.7% (0.0-2.3), 0.0% (0.0-2.0), and 0.9% (0.4-1.6) for rate, respectively. Depth accuracy depended on the target rate (p < 0.001) and on the rescuer couple (p < 0.001) within each method. Conclusions Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study which shows that 10-11 yr olds are capable of effective CPR after a single 2 hour training session using the ABC for Life programme. However they perfrom more effective CPR when using a ratio of 15:2 rather than 30:2 chest compressions : ventilations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An algorithm has been developed for a Public Access Defibrillator which utilizes distinctive features from the impedance cardiogram (ICG) recorded via defibrillator pads to advise both lay users and minimally trained bystanders to ensure CPR effectiveness. Following ethical approval, data were collected and marked. CPR was administered by trained personnel. 211 cases were gathered and the training set included 106 cases. A retrospective analysis was carried out of simultaneously recorded ECG and ICG. The speed of compressions was calculated by counting the outstanding waves in the ICG during CPR. Also if the base-to-peak amplitude of the ICG is greater than a minimum threshold, the corresponding compressions were classified as being applied with adequate force. For the validation set, adequate speed was detected with 91.45% sensitivity and 96.27% specificity (79826s) and adequate force with 99.94% sensitivity and 97.91% specificity (91973s). © 2011 CCAL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared the pharmacokinetics of intraosseous (IO) drug delivery via tibia or sternum, with central venous (CV) drug delivery during cardiopulmonary resuscitation (CPR).Methods: CPR of anesthetized KCl arrest swine was initiated 8 min post arrest. Evans blue and indocyanine green, each were simultaneously injected as a bolus with adrenaline through IO sternal and tibial needles, respectively, n = 7. In second group (n = 6) simultaneous IO sternal and IV central venous (CV) injections were made.Results: Peak arterial blood concentrations were achieved faster for sternal IO vs. tibial IO administration (53 +/- 11 s vs. 107 +/- 27 s, p = 0.03). Tibial IO dose delivered was 65% of sternal administration (p = 0.003). Time to peak blood concentration was similar for sternal IO and CV administration (97 +/- 17 s vs. 70 +/- 12 s, respectively; p = 0.17) with total dose delivered of sternal being 86% of the dose delivered via CV (p = 0.22).Conclusions: IO drug administrations via either the sternum or tibia were effective during CPR in anesthetized swine. However, IO drug administration via the sternum was significantly faster and delivered a larger dose. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons.