964 resultados para Cardiac Output Monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bliacheriene F, Carmona MJC, Barretti CFM, Haddad CMF, Mouchalwat ES, Bortlotto MRFL, Francisco RPV, Zugaib M - Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases. Background and Objectives: Hemodynamic changes are observed during cesarean section under spinal anesthesia. Non-invasive blood pressure (BP) and heart rate (HR) measurements are performed to diagnose these changes, but they are delayed and inaccurate. Other monitors such as filling pressure and cardiac output (CO) catheters with external calibration are very invasive or inaccurate. The objective of the present study was to report the cardiac output measurements obtained with a minimally invasive uncalibrated monitor (LiDCO rapid) in patients undergoing cesarean section under spinal anesthesia. Case report: After approval by the Ethics Commission, four patients agreed to participate in this study. They underwent cesarean section under spinal anesthesia while at the same time being connected to the LiDCO rapid by a radial artery line. Cardiac output, HR, and BP were recorded at baseline, after spinal anesthesia, after fetal and placental extraction, and after the infusion of oxytocin and metaraminol. We observed a fall in BP with an increase of HR and CO after spinal anesthesia and oxytocin infusion; and an increase in BP with a fall in HR and CO after bolus of the vasopressor. Conclusions: Although this monitor had not been calibrated, it showed a tendency for consistent hemodynamic data in obstetric patients and it may be used as a therapeutic guide or experimental tool.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to test the effect of cardiac output (CO) and pulmonary artery hypertension (PHT) on volumetric capnography (VCap) derived-variables. Nine pigs were mechanically ventilated using fixed ventilatory settings. Two steps of PHT were induced by IV infusion of a thromboxane analogue: PHT25 [mean pulmonary arterial pressure (MPAP) of 25 mmHg] and PHT40 (MPAP of 40 mmHg). CO was increased by 50 % from baseline (COup) with an infusion of dobutamine ≥5 μg kg(-1) min(-1) and decreased by 40 % from baseline (COdown) infusing sodium nitroglycerine ≥30 μg kg(-1) min(-1) plus esmolol 500 μg kg(-1) min(-1). Another state of PHT and COdown was induced by severe hypoxemia (FiO2 0.07). Invasive hemodynamic data and VCap were recorded and compared before and after each step using a mixed random effects model. Compared to baseline, the normalized slope of phase III (SnIII) increased by 32 % in PHT25 and by 22 % in PHT40. SnIII decreased non-significantly by 4 % with COdown. A combination of PHT and COdown associated with severe hypoxemia increased SnIII by 28 % compared to baseline. The elimination of CO2 per breath decreased by 7 % in PHT40 and by 12 % in COdown but increased only slightly with COup. Dead space variables did not change significantly along the protocol. At constant ventilation and body metabolism, pulmonary artery hypertension and decreases in CO had the biggest effects on the SnIII of the volumetric capnogram and on the elimination of CO2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Copyright © 2014 International Anesthesia Research Society.BACKGROUND: Goal-directed fluid therapy (GDFT) is associated with improved outcomes after surgery. The esophageal Doppler monitor (EDM) is widely used, but has several limitations. The NICOM, a completely noninvasive cardiac output monitor (Cheetah Medical), may be appropriate for guiding GDFT. No prospective studies have compared the NICOM and the EDM. We hypothesized that the NICOM is not significantly different from the EDM for monitoring during GDFT. METHODS: One hundred adult patients undergoing elective colorectal surgery participated in this study. Patients in phase I (n = 50) had intraoperative GDFT guided by the EDM while the NICOM was connected, and patients in phase II (n = 50) had intraoperative GDFT guided by the NICOM while the EDM was connected. Each patient's stroke volume was optimized using 250- mL colloid boluses. Agreement between the monitors was assessed, and patient outcomes (postoperative pain, nausea, and return of bowel function), complications (renal, pulmonary, infectious, and wound complications), and length of hospital stay (LOS) were compared. RESULTS: Using a 10% increase in stroke volume after fluid challenge, agreement between monitors was 60% at 5 minutes, 61% at 10 minutes, and 66% at 15 minutes, with no significant systematic disagreement (McNemar P > 0.05) at any time point. The EDM had significantly more missing data than the NICOM. No clinically significant differences were found in total LOS or other outcomes. The mean LOS was 6.56 ± 4.32 days in phase I and 6.07 ± 2.85 days in phase II, and 95% confidence limits for the difference were -0.96 to +1.95 days (P = 0.5016). CONCLUSIONS: The NICOM performs similarly to the EDM in guiding GDFT, with no clinically significant differences in outcomes, and offers increased ease of use as well as fewer missing data points. The NICOM may be a viable alternative monitor to guide GDFT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The use of cardiac output monitoring may improve patient outcomes after major surgery. However, little is known about the use of this technology across nations. METHODS: This is a secondary analysis of a previously published observational study. Patients aged 16 years and over undergoing major non-cardiac surgery in a 7-day period in April 2011 were included into this analysis. The objective is to describe prevalence and type of cardiac output monitoring used in major surgery in Europe. RESULTS: Included in the analysis were 12,170 patients from the surgical services of 426 hospitals in 28 European nations. One thousand four hundred and sixteen patients (11.6 %) were exposed to cardiac output monitoring, and 2343 patients (19.3 %) received a central venous catheter. Patients with higher American Society of Anesthesiologists (ASA) scores were more frequently exposed to cardiac output monitoring (ASA I and II, 643 patients [8.6 %]; ASA III-V, 768 patients [16.2 %]; p < 0.01) and central venous catheter (ASA I and II, 874 patients [11.8 %]; ASA III-V, 1463 patients [30.9 %]; p < 0.01). In elective surgery, 990 patients (10.8 %) were exposed to cardiac output monitoring, in urgent surgery 252 patients (11.7 %) and in emergency surgery 173 patients (19.8 %). A central venous catheter was used in 1514 patients (16.6 %) undergoing elective, in 480 patients (22.2 %) undergoing urgent and in 349 patients (39.9 %) undergoing emergency surgery. Nine hundred sixty patients (7.9 %) were monitored using arterial waveform analysis, 238 patients (2.0 %) using oesophageal Doppler ultrasound, 55 patients (0.5 %) using a pulmonary artery catheter and 44 patients (2.0 %) using other technologies. Across nations, cardiac output monitoring use varied from 0.0 % (0/249 patients) to 27.5 % (19/69 patients), whilst central venous catheter use varied from 5.6 % (7/125 patients) to 43.2 % (16/37 patients). CONCLUSIONS: One in ten patients undergoing major surgery is exposed to cardiac output monitoring whilst one in five receives a central venous catheter. The use of both technologies varies widely across Europe.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Aim of post operative treatments after cardiac surgery is to avoid low cardiac output syndrome (LCOS). Levosimendan, a new inotrope agent, has been demonstrated in adult patient to be an effective treatment for this purpose when classical therapy is not effective. It shows a positive effect on cardiac output, with fewer adverse effects and lower mortality than with dopamine. There is very few data on its benefit in the paediatric population. The aim of this study is to evaluate the effect of levosimendan in cardiac children with LCOS.Methods: Retrospective analysis of 25 children hospitalised in our PICU after cardiac surgery that demonstrated LCOS not responding to classical catecholamine therapy and who received levosimendan as rescue. LCOS parameters like urine output, mixed venous oxygen saturation (SvO2), arterio-venous differences in CO2 (AVCO2) and plasmatic lactate were compared before therapy and at 12, 24, 48 and 72 hours after the beginning of the levosimendan infusion. We also analyzed the effect on the utilisation of amines (amine score), adverse events and mortality.Results: After the beginning of levosimendan infusion, urine output (3.1 vs 5.3ml/kg/h, p=0.003) and SVO2 (56 vs 64mmHg, p=0.001) increase significantly during first 72 hours and at the same time plasmatic lactate (2.6 vs 1.4 mmole/l, p<0.001), AVCO2 (11 vs 8 mmHg, p=0.002) and amine score (63 vs 39, p=0.007) decrease significantly. No side effects were noted during administration of levosimendan. In this group of patients, mortality was 0%.Conclusion: Levosimendan is an effective treatment in children after congenital heart surgery. Our study, with a greater sample of patient than other studies, confirms the improvement of cardiac output already shown in other paediatric studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neuropeptide Y (NPY) is a peptide with vasoconstrictor properties known to be present in the central nervous system as well as in sympathetic nerve endings and the adrenal medulla. The purposes of this study were to investigate in normotensive conscious rats the effects of nonpressor doses of NPY on cardiac output and regional blood flow distribution (using radiolabeled microspheres) as well as on plasma renin activity, plasma catecholamine and vasopressin levels. NPY (0.1 microgram/min) infused i.v. for 30 min modified neither blood pressure nor heart rate. Cardiac index was at comparable levels in NPY- as in vehicle-treated rats (17.7 +/- 1.6, n = 8, vs. 21.3 +/- 0.9 ml/min/100 g, n = 8, mean +/- S.E.M.). There was no significant difference in regional blood flow distribution between the two groups of rats, except for the large intestine (0.42 +/- 0.06 vs. 0.71 +/- 0.1 ml/min/g in NPY- and vehicle-treated rats, respectively, P less than .05). Basal plasma renin activity and catecholamine levels were not modified by NPY whereas plasma vasopressin levels were lower (P less than .05) in rats given NPY (0.76 +/- 0.3 pg/ml, n = 8) than in those having received the vehicle (2.2 +/- 0.4 pg/ml).(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We tested the hypothesis that the inability to increase cardiac output during exercise would explain the decreased rate of oxygen uptake (VO2) in recent onset, ischemia-induced heart failure rats. Nine normal control rats and 6 rats with ischemic heart failure were studied. Myocardial infarction was induced by coronary ligation. VO2 was measured during a ramp protocol test on a treadmill using a metabolic mask. Cardiac output was measured with a flow probe placed around the ascending aorta. Left ventricular end-diastolic pressure was higher in ischemic heart failure rats compared with normal control rats (17 ± 0.4 vs 8 ± 0.8 mmHg, P = 0.0001). Resting cardiac index (CI) tended to be lower in ischemic heart failure rats (P = 0.07). Resting heart rate (HR) and stroke volume index (SVI) did not differ significantly between ischemic heart failure rats and normal control rats. Peak VO2 was lower in ischemic heart failure rats (73.72 ± 7.37 vs 109.02 ± 27.87 mL min-1 kg-1, P = 0.005). The VO2 and CI responses during exercise were significantly lower in ischemic heart failure rats than in normal control rats. The temporal response of SVI, but not of HR, was significantly lower in ischemic heart failure rats than in normal control rats. Peak CI, HR, and SVI were lower in ischemic heart failure rats. The reduction in VO2 response during incremental exercise in an ischemic model of heart failure is due to the decreased cardiac output response, largely caused by depressed stroke volume kinetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To consensually validate the operational definitions of the nursing diagnoses activity intolerance, excessive fluid volume, and decreased cardiac output in patients with decompensated heart failure. Method Consensual validation was performed in two stages: analogy by similarity of defining characteristics, and development of operational definitions and validation with experts. Results A total of 38 defining characteristics were found. Operational definitions were developed and content-validated. One hundred percent of agreement was achieved among the seven experts after five rounds. Ascites was added in the nursing diagnosis excessive fluid volume. Conclusion The consensual validation improves interpretation of human response, grounding the selection of nursing interventions and contributing to improved nursing outcomes. Implications for Practice Support the assessment of patients with decompensated heart failure. Objetivos Realizar a validacAo consensual das definicoes operacionais dos diagnosticos de enfermagem Intolerancia a atividade, Volume de liquidos excessivo e Debito cardiaco diminuido em pacientes com insuficiencia cardiaca descompensada. Metodo ValidacAo consensual em duas etapas: Analogia de semelhanca das caracteristicas definidoras e desenvolvimento de definicoes operacionais e validacAo com expertst. Resultados Foram encontradas 38 caracteristicas definidoras para os diagnosticos de enfermagem. Suas definicoes operacionais foram desenvolvidas e seu conteudo validado. Os resultados mostram que houve 100% de concordancia entre os sete experts apos cinco rodada. As definicoes operacionais foram classificadas com base no nivel de concordanica. Ascite foi acrescentada ao diagnostico Volume de liquidos excessivo. ConclusAo A validacAo consensual melhora a interpretacAo das respostas humanas, embasando a selecAo de intervencoes de enfermagem e contribuindo para melhorar os resultados. Implicacoes Para A Pratica Apoio a avaliacAo dos pacientes com insuficiencia cardiaca descompensada.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Hemodynamic support is aimed at providing adequate O-2 delivery to the tissues; most interventions target O-2 delivery increase. Mixed venous O-2 saturation is a frequently used parameter to evaluate the adequacy of O-2 delivery. METHODS: We describe a mathematical model to compare the effects of increasing O-2 delivery on venous oxygen saturation through increases in the inspired O-2 fraction versus increases in cardiac output. The model was created based on the lungs, which were divided into shunted and non-shunted areas, and on seven peripheral compartments, each with normal values of perfusion, optimal oxygen consumption, and critical O-2 extraction rate. O-2 delivery was increased by changing the inspired fraction of oxygen from 0.21 to 1.0 in steps of 0.1 under conditions of low (2.0 L.min(-1)) or normal (6.5 L.min(-1)) cardiac output. The same O-2 delivery values were also obtained by maintaining a fixed O-2 inspired fraction value of 0.21 while changing cardiac output. RESULTS: Venous oxygen saturation was higher when produced through increases in inspired O-2 fraction versus increases in cardiac output, even at the same O-2 delivery and consumption values. Specifically, at high inspired O-2 fractions, the measured O-2 saturation values failed to detect conditions of low oxygen supply. CONCLUSIONS: The mode of O-2 delivery optimization, specifically increases in the fraction of inspired oxygen versus increases in cardiac output, can compromise the capability of the "venous O-2 saturation" parameter to measure the adequacy of oxygen supply. Consequently, venous saturation at high inspired O-2 fractions should be interpreted with caution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] To determine central and peripheral hemodynamic responses to upright leg cycling exercise, nine physically active men underwent measurements of arterial blood pressure and gases, as well as femoral and subclavian vein blood flows and gases during incremental exercise to exhaustion (Wmax). Cardiac output (CO) and leg blood flow (BF) increased in parallel with exercise intensity. In contrast, arm BF remained at 0.8 l/min during submaximal exercise, increasing to 1.2 +/- 0.2 l/min at maximal exercise (P < 0.05) when arm O(2) extraction reached 73 +/- 3%. The leg received a greater percentage of the CO with exercise intensity, reaching a value close to 70% at 64% of Wmax, which was maintained until exhaustion. The percentage of CO perfusing the trunk decreased with exercise intensity to 21% at Wmax, i.e., to approximately 5.5 l/min. For a given local Vo(2), leg vascular conductance (VC) was five- to sixfold higher than arm VC, despite marked hemoglobin deoxygenation in the subclavian vein. At peak exercise, arm VC was not significantly different than at rest. Leg Vo(2) represented approximately 84% of the whole body Vo(2) at intensities ranging from 38 to 100% of Wmax. Arm Vo(2) contributed between 7 and 10% to the whole body Vo(2). From 20 to 100% of Wmax, the trunk Vo(2) (including the gluteus muscles) represented between 14 and 15% of the whole body Vo(2). In summary, vasoconstrictor signals efficiently oppose the vasodilatory metabolites in the arms, suggesting that during whole body exercise in the upright position blood flow is differentially regulated in the upper and lower extremities.