Effects of arterial oxygen tension and cardiac output on venous saturation: a mathematical modeling approach


Autoria(s): Zampieri, Fernando Godinho; Park, Marcelo; Pontes Azevedo, Luciano César; Passos Amato, Marcelo Britto; Vieira Costa, Eduardo Leite
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

12/10/2013

12/10/2013

2012

Resumo

OBJECTIVES: Hemodynamic support is aimed at providing adequate O-2 delivery to the tissues; most interventions target O-2 delivery increase. Mixed venous O-2 saturation is a frequently used parameter to evaluate the adequacy of O-2 delivery. METHODS: We describe a mathematical model to compare the effects of increasing O-2 delivery on venous oxygen saturation through increases in the inspired O-2 fraction versus increases in cardiac output. The model was created based on the lungs, which were divided into shunted and non-shunted areas, and on seven peripheral compartments, each with normal values of perfusion, optimal oxygen consumption, and critical O-2 extraction rate. O-2 delivery was increased by changing the inspired fraction of oxygen from 0.21 to 1.0 in steps of 0.1 under conditions of low (2.0 L.min(-1)) or normal (6.5 L.min(-1)) cardiac output. The same O-2 delivery values were also obtained by maintaining a fixed O-2 inspired fraction value of 0.21 while changing cardiac output. RESULTS: Venous oxygen saturation was higher when produced through increases in inspired O-2 fraction versus increases in cardiac output, even at the same O-2 delivery and consumption values. Specifically, at high inspired O-2 fractions, the measured O-2 saturation values failed to detect conditions of low oxygen supply. CONCLUSIONS: The mode of O-2 delivery optimization, specifically increases in the fraction of inspired oxygen versus increases in cardiac output, can compromise the capability of the "venous O-2 saturation" parameter to measure the adequacy of oxygen supply. Consequently, venous saturation at high inspired O-2 fractions should be interpreted with caution.

Identificador

CLINICS, SAO PAULO, v. 67, n. 8, pp. 897-900, NOV, 2012

1807-5932

http://www.producao.usp.br/handle/BDPI/34173

10.6061/clinics/2012(08)07

http://dx.doi.org/10.6061/clinics/2012(08)07

Idioma(s)

eng

Publicador

HOSPITAL CLINICAS, UNIV SAO PAULO

SAO PAULO

Relação

CLINICS

Direitos

openAccess

Copyright HOSPITAL CLINICAS, UNIV SAO PAULO

Palavras-Chave #MATHEMATICAL MODELING #CENTRAL VENOUS SATURATION #CARDIAC OUTPUT #SEVERE SEPSIS #SEPTIC SHOCK #TRANSPORT #DELIVERY #MEDICINE, GENERAL & INTERNAL
Tipo

article

original article

publishedVersion