76 resultados para Cannulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Distal-to-proximal technique has been recommended for anti-cancer therapy administration. There is no evidence to suggest that a 24-hour delay of treatment is necessary for patients with a previous uncomplicated venous puncture proximal to the administration site. Objectives: This study aims to identify if the practice of 24-hour delay between a venous puncture and subsequent cannulation for anti-cancer therapies at a distal site is necessary for preventing extravasation. Methods: A prospective cohort study was conducted with 72 outpatients receiving anti-cancer therapy via an administration site distal to at least one previous uncomplicated venous puncture on the same arm in a tertiary cancer centre in Australia. Participants were interviewed and assessed at baseline data before treatment and on day 7 for incidence of extravasation/phlebitis. Results: Of 72 participants with 99 occasions of treatment, there was one incident of infiltration (possible extravasation) at the venous puncture site proximal to the administration site and two incidents of phlebitis at the administration site. Conclusions: A 24 hour delay is unnecessary if an alternative vein can be accessed for anti-cancer therapy after a proximal venous puncture. Implications for practice: Extravasation can occur at a venous puncture site proximal to an administration site in the same vein. However, the nurse can administer anti-cancer therapy at a distal site if the nurse can confidently determine the vein of choice is not in any way connected to the previous puncture site through visual inspection and palpation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Right heart dysfunction is one of the most serious complications following implantation of a left ventricular assist device (LVAD), often leading to the requirement for short or long term right ventricular support (RVAD). The inflow cannulation site induces major haemodynamic changes and so there is a need to optimize the site used depending on the patient's condition. Therefore, this study evaluated and compared the haemodynamic influence of right atrial (RAC) and right ventricular (RVC) inflow cannulation sites. An in-vitro, variable heart failure, mock circulation loop was used to compare RAC and RVC in mild and severe biventricular heart failure (BHF) conditions. In the severe BHF condition, higher ventricular ejection fraction (RAC: 13.6%, RVC: 32.7%) and thus improved heart chamber and RVAD washout was observed with RVC, which suggested this strategy might be preferable for long term support (ie. bridge to transplant or destination therapy) to reduce the risk of thrombus formation. In the mild BHF condition, higher pulmonary valve flow (RAC: 3.33 L/min, RVC: 1.97 L/min) and lower right ventricular stroke work (RAC: 0.10 W, RVC: 0.13 W) and volumes were recorded with RAC. These results indicate an improved potential for myocardial recovery, thus RAC should be chosen in this condition. This in-vitro study suggests that RVAD inflow cannulation site should be chosen on a patient-specific basis with a view to the support strategy to promote myocardial recovery or reduce the risk of long-term complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arteriovenous fistulae are considered the gold standard for haemodialysis vascular access. Their use can be fraught with complications for both the patient and cannulator, with knowledge, expertise and skills being key factors in reducing access associated morbidity. There is mounting evidence demonstrating the efficacy of the buttonhole technique. One disturbing problem noted with the buttonhole experience has been an increased rate in site infections, anecdotally attributed to poor buttonhole site preparation. Enhanced knowledge and skills for nurses are crucial in increasing patient comfort and improving outcomes.

Although knowledge and skill acquisition related to vascular access are often the focus of individual institutional educational initiatives, a national evidence based program that provides free equitable access to all nurses does not exist in Australasia. A survey of Australasian Nephrology Educators’ identified the need for more effective and consistent delivery of clinical education for nurses using innovative, web‐based approaches that support the tenets of e-learning methodologies. This paper will discuss the development and implementation of an e-learning program for buttonhole cannulation. The preparedness of participants to professionally engage with buttonhole cannulation and their self-efficacy (estimates) in undertaking learning about the clinical procedure using e-learning will be evaluated. In addition it will highlight the benefits of inter‐organizational partnerships and how they can facilitate positive change in teaching and learning practices aimed at improving patient outcomes. This project has unique characteristics that collectively provide value, distinction and innovation to patients, nurses, and renal departments across Australasia. As the e-learning program is founded on evidence based practice this project is easily transferable to an international context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT
Background

Topical treatments such as Arnica cream and mucopolysaccharide polysulfuric acid (contained in Hirudoid cream) have been used to treat the bruising and pain arising from dialysis-related infiltrations.
Aim: 
To undertake a randomised controlled pilot study comparing the efficacy of Arnica and Hirudoid creams in treating bruising and pain following post-needling infiltration.
Methods: 
One dialysis centre of 40 patients over a 12-month period. Following infiltration, and at the five subsequent dialysis treatments, pain was measured using the Abbey pain scale and size of the bruise was recorded.
Results: 
Eleven cases of infiltration were recorded consisting of seven males (64%) and four females (36%) who had a mean age of 78 years (SD=9). Access for eight patients was via arteriovenous fistula and for three patients via arteriovenous graft. Eight patients experienced bruising and two patients reported mild pain post-infiltration but there were no differences found between the effect of Arnica or Hirudoid in treating either symptom.
Conclusion: 
This pilot study was unable to detect any differences in the effect of Arnica and Hirudoid on pain or bruising. The study demonstrated that a larger, multicentre trial would be required to power a study and that a non-interventional control group should be added.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To propose a simulation-based ultrasound-guided central venous cannulation skills' training program, during residency.METHODS: This study describes the strategies for learning the ultrasound-guided central venous cannulation on low-fidelity bench models. The preparation of bench models, educational goals, processes of skill acquisition, feedback and evaluation methods were also outlined. The training program was based on key references to the subject.RESULTS: It was formulated a simulation-based ultrasound-guided central venous cannulation teaching program on low-fidelity bench models.CONCLUSION: A simulation-based inexpensive, low-stress, no-risk learning program on low-fidelity bench models was proposed to facilitate acquisition of ultrasound-guided central venous cannulation skills by residents-in-training before exposure to the living patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated a novel, sled-mounted needle guide for ultrasound-guided vessel cannulation. Fifty medical students were randomly assigned to use ultrasound with the sled (sled group, n = 23) or ultrasound without the sled (control group, n = 27) for vessel cannulation in a phantom. For each of 15 attempts we recorded cannulation time and designated a successful cannulation as 1 and a failure as 0. Our primary outcome was the mean overall success rate. The median (IQR [range]) number of successes in the sled group and control group were 15.0 (13.0-15.0 [11.0-15.0]) and 11.0 (9.0-13.0 [6.0-15.0]), respectively (p < 0.001). Cannulation time decreased from the first to the last attempt in the sled group from 7.0 s (6.0-10.0 [4.0-16]) s to 4.0 s (3.0-4.0 [1.0-6.0]) s and in the control group from 35.0 s (27.0-35.0 [11.0-35.0]) s to 7.0 s (5.0-10.0 [3.0-25.0]) s. The sled group demonstrated a shorter cannulation time at each attempt (p < 0.001). The novel sled improved the success rate and efficiency of ultrasound-guided phantom vessel cannulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Right axillary artery (RAA) cannulation is increasingly used in cardiac surgery. Little is known about resulting flow patterns in the aorta. Therefore, flow was visualized and analyzed. A mock circulatory circuit was assembled based on a compliant transparent anatomical silicon aortic model. A RAA cannula was connected to a continuous flow rotary blood pump (RBP), pulsatile heart action was provided by a pneumatic ventricular assist device (PVAD). Peripheral vascular resistance, regional flow and vascular compliance were adjusted to obtain physiological flow and pressure waveforms. Colorants were injected automatically for flow visualization. Five flow distributions with a total flow of 4 l/min were tested (%PVAD:%RBP): 100:0, 75:25, 50:50, 25:75, 0:100. Colorant distribution was assessed using quantitative 2D image processing. Continuous flow from the RAA divided in a retrograde and an antegrade portion. Retro- to antegrade flow ratio increased with increasing RAA-flow. At full RBP support flow was stagnant in the ascending aorta. There were distinct flow patterns between the right- and left-sided supra-aortic branches. At full RBP support retrograde flow was demonstrated in the right carotid and right vertebral arteries. Further studies are needed to confirm and evaluate the described flow patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of positioning and geometry of ventricular cannulas for contemporary continuous flow Left Ventricular Assist Devices (LVADs) was evaluated in a non-beating isolated heart preparation with borescopic visualization. Preload and LVAD flow were varied to evaluate degrees of ventricular decompression up to the point of ventricular collapse. The performance of a flanged cannula was compared to a conventional bevel-tipped cannula: quantitatively by the maximal flow attainable, and qualitatively by visualization of fluid tracer particles within the ventricular chamber. Three forms of ventricular suck-down occurred: concentric collapse, gradual entrainment and instantaneous entrainment. In some circumstances, unstable oscillations of the ventricle were observed prior to complete collapse. Under conditions of low preload, the flanged cannula demonstrated less positional sensitivity, provided greater flow, and exhibited fewer areas of stagnation than the beveled cannula. These observations warrant further consideration of a flanged ventricular cannula to mitigate complications encountered with conventional cannulae.