996 resultados para CT value


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Epilepsy is a syndrome of episodic brain dysfunction characterized by recurrent unpredictable, spontaneous seizures. Cerebellar dysfunction is a recognized complication of temporal lobe epilepsy and it is associated with seizure generation, motor deficits and memory impairment. Serotonin is known to exert a modulatory action on cerebellar function through 5HT2C receptors. 5-HT2C receptors are novel targets for developing anticonvulsant drugs. In the present study, we investigated the changes in the 5-HT2C receptors binding and gene expression in the cerebellum of control, epileptic and Bacopa monnieri treated epileptic rats. There was a significant down regulation of the 5-HT content (pb0.001), 5-HT2C gene expression (pb0.001) and 5-HT2C receptor binding (pb0.001) with an increased affinity (pb0.001). Carbamazepine and B. monnieri treatments to epileptic rats reversed the down regulated 5-HT content (pb0.01), 5-HT2C receptor binding (pb0.001) and gene expression (pb0.01) to near control level. Also, the Rotarod test confirms the motor dysfunction and recovery by B. monnieri treatment. These data suggest the neuroprotective role of B. monnieri through the upregulation of 5-HT2C receptor in epileptic rats. This has clinical significance in the management of epilepsy

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The results of shore-based three-axis resistivity and X-ray computed tomography (CT) measurements on cube-shaped samples recovered during Leg 185 are presented along with moisture and density, P-wave velocity, resistivity, and X-ray CT measurements on whole-round samples of representative lithologies from Site 1149. These measurements augment the standard suite of physical properties obtained during Leg 185 from the cube samples and samples obtained adjacent to the cut cubes. Both shipboard and shore-based measurements of physical properties provide information that assists in characterizing lithologic units, correlating cored material with downhole logging data, understanding the nature of consolidation, and interpreting seismic reflection profiles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Biomineralization in the marine phytoplankton Emiliania huxleyi is a stringently controlled intracellular process. The molecular basis of coccolith production is still relatively unknown although its importance in global biogeochemical cycles and varying sensitivity to increased pCO2 levels has been well documented. This study looks into the role of several candidate Ca2+, H+ and inorganic carbon transport genes in E. huxleyi, using quantitative reverse transcriptase PCR. Differential gene expression analysis was investigated in two isogenic pairs of calcifying and non-calcifying strains of E. huxleyi and cultures grown at various Ca2+ concentrations to alter calcite production. We show that calcification correlated to the consistent upregulation of a putative HCO3- transporter belonging to the solute carrier 4 (SLC4) family, a Ca2+/H+ exchanger belonging to the CAX family of exchangers and a vacuolar H+-ATPase. We also show that the coccolith-associated protein, GPA is downregulated in calcifying cells. The data provide strong evidence that these genes play key roles in E. huxleyi biomineralization. Based on the gene expression data and the current literature a working model for biomineralization-related ion transport in coccolithophores is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To reveal the moisture migration mechanism of the unsaturated red clays, which are sensitive to water content change and widely distributed in South China, and then rationally use them as a filling material for highway embankments, a method to measure the water content of red clay cylinders using X-ray computed tomography (CT) was proposed and verified. Then, studies on the moisture migrations in the red clays under the rainfall and ground water level were performed at different degrees of compaction. The results show that the relationship between dry density, water content, and CT value determined from X-ray CT tests can be used to nondestructively measure the water content of red clay cylinders at different migration time, which avoids the error reduced by the sample-to-sample variation. The rainfall, ground water level, and degree of compaction are factors that can significantly affect the moisture migration distance and migration rate. Some techniques, such as lowering groundwater table and increasing degree of compaction of the red clays, can be used to prevent or delay the moisture migration in highway embankments filled with red clays.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Report published in the Proceedings of the National Conference on "Education and Research in the Information Society", Plovdiv, May, 2014

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represent significant diagnostic challenges. SPECT/CT Image fusion can provide missing anatomical and bone structure information to functional imaging, which is particularly useful to increase diagnosis certainty of bone pathology. However, due to SPECT acquisition duration, patient’s involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We aimed at designing an ankle and foot immobilizing device and measuring its efficacy at improving image fusion. Methods: We enrolled 20 patients undergoing distal lower-limb SPECT/CT of the ankle and the foot with and without a foot holder. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomical landmarks also visible on bone scintigraphy. Analysis of variance was performed for statistical analysis. Results: The obtained absolute average difference without and with support was 5.1±5.2 mm (mean±SD) and 3.1±2.7 mm, respectively, which is significant (p<0.001). Conclusion: The introduction of the foot holder significantly decreases misalignment between SPECT and CT images, which may have clinical influence in the precise localization of foot and ankle pathology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) quantifies the extent of early ischemic changes in the posterior circulation with a 10-point grading system. We hypothesized that pc-ASPECTS applied to CT angiography source images predicts functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). METHODS: BASICS was a prospective, observational registry of consecutive patients with acute symptomatic basilar artery occlusion. Functional outcome was assessed at 1 month. We applied pc-ASPECTS to CT angiography source images of patients with CT angiography for confirmation of basilar artery occlusion. We calculated unadjusted and adjusted risk ratios (RRs) of pc-ASPECTS dichotomized at ≥8 versus <8. Primary outcome measure was favorable outcome (modified Rankin Scale scores 0-3). Secondary outcome measures were mortality and functional independence (modified Rankin Scale scores 0-2). RESULTS: Of 158 patients included, 78 patients had a CT angiography source images pc-ASPECTS≥8. Patients with a pc-ASPECTS≥8 more often had a favorable outcome than patients with a pc-ASPECTS<8 (crude RR, 1.7; 95% CI, 0.98-3.0). After adjustment for age, baseline National Institutes of Health Stroke Scale score, and thrombolysis, pc-ASPECTS≥8 was not related to favorable outcome (RR, 1.3; 95% CI, 0.8-2.2), but it was related to reduced mortality (RR, 0.7; 95% CI, 0.5-0.98) and functional independence (RR, 2.0; 95% CI, 1.1-3.8). In post hoc analysis, pc-ASPECTS dichotomized at ≥6 versus <6 predicted a favorable outcome (adjusted RR, 3.1; 95% CI, 1.2-7.5). CONCLUSIONS: pc-ASPECTS on CT angiography source images independently predicted death and functional independence at 1 month in the CT angiography subgroup of patients in the BASICS registry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectif : Les épanchements pleuraux sont fréquents chez les patients porteurs de cancer et déterminer s'ils sont de nature tumorale ou non relève d'une grande importance clinique, particulièrement pour le groupe des carcinomes pulmonaires NON à petites cellules (NSCLC). Le PET/CT s'est montré d'une grande utilité et est actuellement indiscutablement reconnu comme outils nécessaire dans la prise en charge et notamment la stadification et le suivi des cancers, et particulièrement des cancers pulmonaires. Sa capacité à pouvoir distinguer les épanchements pleuraux malins des épanchements pleuraux non tumoraux, « bénins » n'est pas précisément connue et n'a pas jusqu'à présent été investiguée de manière approfondie. Matériel et méthodes : Nous avons examiné la captation du FDG (indice SUVmax) des épanchements pleuraux de 50 PET/CT réalisés chez 47 patients (29 hommes, 18 femmes, 60±16 ans) avec épanchements pleuraux et cancer connu (24 NSCLC, 7 lymphomes, 5 cancer du sein, 4 GIST, 3 mésothéliomes, 2 cancer ORL, 2 tératomes malins, 1 carcinome colorectal, 1 carcinome oesophagien, 1 mélanome). Ces résultats ont été corrélés aux résultats des examens cytopathologiques réalisés après ponction de ces mêmes épanchements dans un intervalle médian de 21 jours (interquartile range -3 to 23). L'examen du liquide d'épanchement comportait la mesure du pH, la distribution relative des différents éléments cellulaires (macrophages, neutrophils, éosinophiles, basophiles, lymphocytes, plasmocytes), la numération cellulaire et bien entendu présence de cellules tumorales. Résultats : Parmis les épanchements, 17 étaient malins (34%) (6 NSCLC, 5 lymphomes, 2 cancers mammaires, 2 mésothéliomes, 2 tératomes malins). Les SUV étaient plus élevés dans les épanchements malins que dans les épanchements bénins [3.7 (95%IC 1.8-5.6) vs. 1.7 g/ml (1.5-1.9), p = 0.001], avec une corrélation entre les épanchements malins et le SUV (coefficient de Spearman ρ = 0.50, p = 0.001). Il n'a pas été observé de corrélation entre aucun des autres paramètres cyptopathologiques ou radiologiques analysé (aire sous la courbe ROC 0.83 ± 0.06). En utilisant un seuil du SUV de 2.2-mg/l, 12 examens PET/CT étaient interprétés comme positifs and 38 comme négatifs avec une sensibilité et une spécificité, valeur prédictive positive et négative de 53%, 91%, 75% and 79% respectivement. Concernant le groupe des NSCLC seulement (n = 24), aire sous la courbe ROC était de 0.95 ± 0.04. Sept examens étaient considérés comme positifs et 17 comme négatifs avec une sensibilité, une spécificité, valeur prédictive positive et négative de 83%, 89%, 71 et 94% respectivement. Conclusion : Le PET/CT peut aider à différencier la nature bénigne ou maligne des épanchements avec une haute spécificité chez les patients avec tumeur connue, en particulier dans un contexte de carcinome NON à petites cellules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Rapport de synthèse : Objectif : Le but de ce travail est d`étudier l'angiographie par scanner multi-barrette (AS) dans l'évaluation de l'artériopathie oblitérante (AOMI) de l'aorte abdominale et des membres inférieurs utilisant une méthode adaptative d'acquisition pour optimiser le rehaussement artériel en particulier pour le lit artériel distal et les artères des pieds. Matériels et méthodes : Trente-quatre patients pressentant une AOMI ont bénéficié d'une angiographie trans-cathéter (ATC) et d'une AS dans un délai inférieur ou égal à 15 jours. L'AS a été effectuée du tronc coeliaque jusqu'aux artères des pieds en une seule acquisition utilisant une haute résolution spatiale (16x0.625 mm). La vitesse de table et le temps de rotation pour chaque examen ont été choisis selon le temps de transit du produit de contraste, obtenu après un bolus test. Une quantité totale de 130 ml de contraste à 4 ml/s a été utilisée. L'analyse des images de l'AS a été effectuée par deux observateurs et les données ATC ont été interprétées de manière indépendante par deux autres observateurs. L'analyse a inclus la qualité de l'image et la détection de sténose supérieure ou égale à 50 % par patient et par segment artériel. La sensibilité et la spécificité de l'AS ont été calculées en considérant l'ATC comme examen de référence. La variabilité Interobservateur a été mesurée au moyen d'une statistique de kappa. Résultas : L'ATC a été non-conclusive dans 0.7 % des segments, tandis que l'AS était conclusive dans tous les segments. Sur l'analyse par patient, la sensibilité et la spécificité totales pour détecter une sténose significative égale ou supérieure à 50 % étaient de 100 %. L'analyse par segment a montré des sensibilités et de spécificités variant respectivement de 91 à 100 % et de 81 à 100 %. L'analyse des artères distales des pieds a révélé une sensibilité de 100 % et une spécificité de 90 %. Conclusion : L'angiographie par CT multi-barrettes utilisant cette méthode adaptative d'acquisition améliore la qualité de l'image et fournit une technique non-invasive et fiable pour évaluer L'AOMI, y compris les artères distales des pieds.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Positron emission tomography is a functional imaging technique that allows the detection of the regional metabolic rate, and is often coupled with other morphological imaging technique such as computed tomography. The rationale for its use is based on the clearly demonstrated fact that functional changes in tumor processes happen before morphological changes. Its introduction to the clinical practice added a new dimension in conventional imaging techniques. This review presents the current and proposed indications of the use of positron emission/computed tomography for prostate, bladder and testes, and the potential role of this exam in radiotherapy planning.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To determine the diagnostic value of 18F-FDG PET/CT versus contrastenhanced CT in identifying chest wall invasion by NSCLC. Methods and Materials: The primary selection criterion was a peripheral tumor of any size with contact to the chest wall. A total of 25 patients with pathologically proven NSCLC satisfied these criteria. Chest wall invasion was interpreted upon PET/CT when a frank costal or intercostal 18F-FDG uptake was identified with or without concomitant morphologic alterations. On the other hand, the existence of periosteal rib reaction/erosion, chest wall thickening or obliteration of the pleural fat layer either separately or combined were considered essential diagnostic criteria for disease extension into the chest wall upon contrast-enhanced CT. The results were correlated with the final histological analysis. Results: Among the studied cohort, 13/25 (52%) patients had chest wall invasion consistent with T3 disease. Both PET/CT and contrast-enhanced CT successfully identified 12/13 (92%) of these patients. The single false-negative result was due to parietal pleural invasion. On the other hand, one false-positive result was encountered by PET/CT in a dyspneic patient; whereas, CT analysis revealed false-positive results in six patients. In these patients, periosteal rib reaction (n = 2) or asymmetric enlargement of adjacent chest wall muscles (n = 1) were identified along with an obliterated pleural fat layer (n = 6). The sensitivity, specificity, and accuracy of PET/CT and contrast-enhanced CT were 92, 91 and 92% versus 92, 50 and 72%. Conclusion: 18F-FDG PET/CT is an accurate diagnostic modality in identifying.