985 resultados para CMS detectors


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Results are presented from a search for the pair production of third-generation scalar and vector leptoquarks, as well as for top squarks in R-parity-violating supersymmetric models. In either scenario, the new, heavy particle decays into a τ lepton and a b quark. The search is based on a data sample of pp collisions at √s=7 TeV, which is collected by the CMS detector at the LHC and corresponds to an integrated luminosity of 4.8 fb -1. The number of observed events is found to be in agreement with the standard model prediction, and exclusion limits on mass parameters are obtained at the 95% confidence level. Vector leptoquarks with masses below 760 GeV are excluded and, if the branching fraction of the scalar leptoquark decay to a τ lepton and a b quark is assumed to be unity, third-generation scalar leptoquarks with masses below 525 GeV are ruled out. Top squarks with masses below 453 GeV are excluded for a typical benchmark scenario, and limits on the coupling between the top squark, τ lepton, and b quark, λ333′ are obtained. These results are the most stringent for these scenarios to date. © 2013 CERN.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A search for the pair production of a heavy, narrow resonance decaying into two jets has been performed using events collected in √s=7 TeV pp collisions with the CMS detector at the LHC. The data sample corresponds to an integrated luminosity of 5.0 fb-1. Events are selected with at least four jets and two dijet combinations with similar dijet mass. No resonances are found in the dijet mass spectrum. The upper limit at 95% confidence level on the product of the resonance pair production cross section, the branching fractions into dijets, and the acceptance varies from 0.22 to 0.005 pb, for resonance masses between 250 and 1200 GeV. Pair-produced colorons decaying into qq̄ are excluded for coloron masses between 250 and 740 GeV. © 2013 CERN. citation, and DOI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The first measurement of vector-boson production associated with a top quark-antiquark pair in proton-proton collisions at √s=7 TeV is presented. The results are based on a data set corresponding to an integrated luminosity of 5.0 fb-1, recorded by the CMS detector at the LHC in 2011. The measurement is performed in two independent channels through a trilepton analysis of tt̄Z events and a same-sign dilepton analysis of tt̄V (V=W or Z) events. In the trilepton channel a direct measurement of the tt̄Z cross section σtt̄Z=0.28-0.11+0.14 (stat)-0.03+0.06 (syst) pb is obtained. In the dilepton channel a measurement of the tt̄V cross section yields σtt̄V=0.43-0.15+0.17 (stat)-0.07+0.09 (syst) pb. These measurements have a significance, respectively, of 3.3 and 3.0 standard deviations from the background hypotheses and are compatible, within uncertainties, with the corresponding next-to-leading order predictions of 0.137-0.016+0.012 and 0.306-0.053+0.031 pb. © 2013 CERN. Published by the American Physical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A análise descrita nesta dissertação tem como objetivo a medida da seção de choque difrativa dσ/d|t| à energia no sistema do centro de massa de √s = 8 TeV. Os eventos usados para obter a seção de choque difrativa foram selecionados para processos de difração simples com um próton espalhado na região frontal e na região cinemática de 0,03 <|t| < 1,0 GeV e 0,03 < ξ < 0.1, usando os dados em comum obtidos em 2012 dos detectores CMS e TOTEM, o qual permite ter uma perspectiva mais detalhada do processo difrativo, devido à aceitação completa que oferece a combinação dos detectores. Os dados foram corrigidos devido à aceitação e eficiência do detector. A partir de uma parametrização exponencial da forma Ae ^Bt, o valor da inclinação do processo em que o próton espalhado é detectado em ambas as direções positiva da CMS é de B= -6,403 1,241 GeV- .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O Compact Muon Solenoid (CMS) é um dos principais detectores instalados no LHC que possibilita o estudo de diferentes aspectos da Física, indo do Modelo Padrão à matéria escura. Esse detector de propósito geral, foi construído para ser capaz de medir múons com uma grande precisão e todos os seus subdetectores foram construídos com uma alta granularidade, tornando possível identificar e caracterizar as propriedades cinemáticas das partículas finais da colisão. O algoritmo de reconstrução de eventos inclui a identificação de jatos, ou seja, é possível identificar a assinatura da produção de pártons na colisão e a medida de seções de choque da produção de muitos jatos é um dos métodos para se explorar as contribuições da Cromodinâmica Quântica (Quantum Chromodynamics - QCD) perturbativa, permitindo avaliar as previsões implementadas nas simulações de eventos. Tendo em vista a caracterização de processos relacionados com a QCD em colisões de próton-próton a uma energia do centro de massa de 7 TeV, é apresentada a medida da seção de choque da produção inclusiva de multijatos no CMS. Para realizar essa medida foram utilizados dados reais coletados em 2010, onde não se apresentava muitas colisões por cruzamento de pacote, com uma luminosidade integrada de L = 2,869 pb-1 e utilizando jatos que estão em quase todo o espaço de fase acessível em pseudorapidez |n|≤ 4,8 e momentum transverso pT ≥ 30 GeV/ c2. Desse resultado foram removidos os efeitos de detecção comparado com predições simuladas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Developed for use with triple GEM detectors, the GEM Electronic Board (GEB) forms a crucial part of the electronics readout system being developed as part of the CMS muon upgrade program. The objective of the GEB is threefold; to provide stable powering and ground for the VFAT3 front ends, to enable high-speed communication between 24 VFAT3 front ends and an optohybrid, and to shield the GEM detector from electromagnetic interference. The paper describes the concept and design of a large-size GEB in detail, highlighting the challenges in terms of design and feasibility of this deceptively difficult system component.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 pb-1 of data collected in pp collisions at s = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV/c is above 95% over the whole region of pseudorapidity covered by the CMS muon system, < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeVc is higher than 90% over the full η range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100GeV/c and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV/c. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation. © 2012 IOP Publishing Ltd and Sissa Medialab srl.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)