1000 resultados para CIM-9


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aquest treball final de carrera es basa en l'anàlisi, disseny i implementació d'una aplicació per tal de facilitar la tasca diària als professionals mèdics. Podem definir el mCIM-9 com un gran manual de consulta i d'organització de continguts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In the United States, the Agency for Healthcare Research and Quality (AHRQ) has developed 20 Patient Safety Indicators (PSIs) to measure the occurrence of hospital adverse events from medico-administrative data coded according to the ninth revision of the international classification of disease (ICD-9-CM). The adaptation of these PSIs to the WHO version of ICD-10 was carried out by an international consortium. METHODS: Two independent teams transcoded ICD-9-CM diagnosis codes proposed by the AHRQ into ICD-10-WHO. Using a Delphi process, experts from six countries evaluated each code independently, stating whether it was "included", "excluded" or "uncertain". During a two-day meeting, the experts then discussed the codes that had not obtained a consensus, and the additional codes proposed. RESULTS: Fifteen PSIs were adapted. Among the 2569 proposed diagnosis codes, 1775 were unanimously adopted straightaway. The 794 remaining codes and 2541 additional codes were discussed. Three documents were prepared: (1) a list of ICD-10-WHO codes for the 15 adapted PSIs; (2) recommendations to the AHRQ for the improvement of the nosological frame and the coding of PSI with ICD-9-CM; (3) recommendations to the WHO to improve ICD-10. CONCLUSIONS: This work allows international comparisons of PSIs among the countries using ICD-10. Nevertheless, these PSIs must still be evaluated further before being broadly used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The specification of Quality of Service (QoS) constraints over software design requires measures that ensure such requirements are met by the delivered product. Achieving this goal is non-trivial, as it involves, at least, identifying how QoS constraint specifications should be checked at the runtime. In this paper we present an implementation of a Model Driven Architecture (MDA) based framework for the runtime monitoring of QoS properties. We incorporate the UML2 superstructure and the UML profile for Quality of Service to provide abstract descriptions of component-and-connector systems. We then define transformations that refine the UML2 models to conform with the Distributed Management Taskforce (DMTF) Common Information Model (CIM) (Distributed Management Task Force Inc. 2006), a schema standard for management and instrumentation of hardware and software. Finally, we provide a mapping the CIM metamodel to a .NET-based metamodel for implementation of the monitoring infrastructure utilising various .NET features including the Windows Management Instrumentation (WMI) interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Providing information about medication, an essential function of pharmaceutical practice to ensure rational drug use, is an important activity of hospital pharmacy services. The Drug Information Center of Onofre Lopes University Hospital (DIC-HUOL) initiated its activities in 1979 with the first Clinical Pharmacy Service in Brazil. The aim of this study was to assess information provided by DIC-HUOL, describing the profile of passive information offered by the center. A retrospective cross-sectional study was conducted to identify the profile of information requests (IR). One hundred percent of the IR received by the DIC between January 2008 and December 2009 were used. The results were divided by year to determine the influence of the restructuring process that occurred in 2008 and 2009. The study at DIC-HUOL showed a mean of 5.5 IR/month in 2008 and 20.3 IR/month in 2009; the mean of the last year is comparable to that of other Brazilian DIC. Most of the IR were made by medical residents (22.7%) in 2008 and by pharmacists (32.5%) in 2009. The significant use of the DIC by medical residents may be due to its location in a university hospital. The most recurrent types of IR concerned issues related to pathway/mode of administration (16.8%) and drug stability (13.1%) in 2008 and 2009, respectively. Requests were made verbally in 100% of the cases in 2008 and 78.8% in 2009, owing to the fact that most of the DIC users were professionals from the hospital itself. Time elapsed between request and response was not reported in 83.3% and 21.3% of the cases in 2008 and 2009, respectively. The most widely used bibliographic source during the two years was MICROMEDEX®, with 41.9% and 39.2%, respectively. The restructuring process had a positive influence on the DIC-HUOL, exhibiting similar parameters to those of other Brazilian DIC, but some of these parameters must be improved to achieve international standards

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the photophysical properties (excitation and fluorescence spectra, fluorescence quantum yield, fluorescence lifetimes) of the poly(2,7-9,9'-dihexylfluorene-dyil) in dilute solutions of four solvents (toluene, tetrahydrofuran, chloroform and ethyl acetate) as well as the properties in solid state. Photoluminescence showed spectra characteristic of disordered α-backbone chain conformation. Simulation of the electronic absorption spectra of oligomers containing 1 to 11 mers showed that the critical conjugation length is between 6 and 7 mers. We also estimated the theoretical dipole moments which indicated that a coil conformation is formed with 8 repeating units per turn. We also showed that some energy transfer process appears in solid state which decreases the emission lifetime. Furthermore, based on luminescent response of the systems herein studied and electroluminescent behavior reported on literature, both photo and electroluminescence emissions arise from the same emissive units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foi estudado o comportamento eletroquímico a 37°C do aço inoxidável ISO 5832-9, em meios de NaCl 0,9 %, de Ringer Lactato e meio mínimo de Eagle (MEM), por voltametria linear e análises da superfície por microscopia eletrônica de varredura (MEV) e por espectroscopia por dispersão de energia (EDS). Foram feitos ensaios mecânicos e testes de toxicidade. O aço ISO 5832-9 se encontra passivado no potencial de corrosão e não apresenta corrosão por pite nos três meios estudados em toda faixa de potencial investigada, desde o potencial de corrosão até 50 mV acima do potencial de transpassivação. Em meio de MEM, no entanto, as análises por MEV e EDS mostraram que o referido aço, nesse valor mais elevado de potencial, apresentou um comportamento diferente, com perda das inclusões de óxido de manganês. Os potenciais de corrosão, Ecorr (potencial de circuito aberto estacionário) bem como os valores de densidade de corrente de passivação, variaram na seguinte ordem: Ecorr, RL < Ecorr, NaCl < Ecorr, MEM. e jMEM << jRL ≅ jNaCl. No ensaio de citotoxicidade, o aço foi caracterizado como não-tóxico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study objective was to examine differentials in time trends and predictors of deaths assigned to symptoms, signs and ill-defined conditions in comparison with other ill-defined conditions (ill-defined cardiovascular diseases, cancer and injury) in a population-based cohort study. Of 1,606 baseline participants aged 60 years and over, 524 died during 9-year follow-up and were included in this study. Deaths coded to "symptoms" declined by 77% in the period from 1997-1999 to 2003-2005. Deaths coded to other ill-defined conditions remained unchanged. The calendar period 2003-2005 (RR = 0.25; 95%CI: 0.09-0.70) and in-hospital deaths (RR = 0.16; 95%CI: 0.08-0.34) were independently associated with "symptoms", but not with other ill-defined conditions. Baseline socio-demographic characteristics and chronic diseases were not predictors of these outcomes. International and national agencies have focused on the reduction of deaths assigned to "symptoms" to improve the registration of vital statistics, while other ill-defined conditions have received little attention. Our data provide evidence supporting the need to redress this situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temperature-dependent electrical resistance in quasi-one-dimensional Li(0.9)Mo(6)O(17) is described by two Luttinger liquid anomalous exponents alpha, each associated with a distinct one dimensional band. The band with alpha < 1 is argued to crossover to a higher dimension below the temperature T(M'), leading to superconductivity. Disorder and magnetic fields are shown to induce the Bose metal behavior in this bulk compound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Matrix metalloproteinase-9 (MMP-9) and tissue inhibitor of MMP (TIMP) promote derangement of the extracellular matrix, which is ultimately reflected in plaque images seen on ultrasound. Videodensitometry can identify structural disturbances in plaques. Objectives: To establish the correlations between values determined using videodensitometry in B-mode ultrasound images of advanced carotid plaques and the total expression of MMP-9 and TIMP-1 in these removed plaques. Methods: Thirty patients underwent ultrasonic tissue characterization of carotid plaques before surgery, using mean gray level (MGL), energy, entropy and homogeneity. Each patient was assigned preoperatively to one of 2 groups: group I, symptomatic patients (n = 16; 12 males; mean age 66.7 +/- 6.8 years), and group II, asymptomatic patients (n = 14; 8 males; mean age 67.6 +/- 6.81 years). Tissue specimens were analyzed for MMP-9 and TIMP-1 expression. Nine carotid arteries were used as normal tissue controls. Results: MMP-9 expression levels were elevated in group II and in normal tissues compared to group I (p < 0.001). TIMP-1 levels were higher in group II than in group I, and significantly higher in normal tissues than in group I (p = 0.039). The MGL was higher in group II compared to group I (p = 0.038). Energy had greater values in group II compared to group I (p = 0.02). There were no differences between patient groups in homogeneity and entropy. Energy positively correlated with MMP-9 and TIMP-1 expression (p = 0.012 and p = 0.031 respectively). Homogeneity positively correlated with MMP-9 and TIMP-1 expression (p = 0.034 and p = 0.047 respectively). There were no correlations between protein expression and MGL or entropy. Conclusions: Videodensitometric computer analysis of ultrasound scanning images can be used to identify stable carotid plaques, which have higher total expression levels of MMP-9 and TIMP-1 than unstable plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elastic scattering angular distributions for (7)Be, (9)Be, and (10)Be isotopes on (12)C target were measured at laboratory energies of 18.8, 26.0, and 23.2 MeV, respectively. The analysis was performed in terms of optical model potentials using Woods-Saxon and double-folding form factors. Also, continuum discretized coupled-channels calculations were performed for (7)Be and (9)Be + (12)C systems to infer the role of breakup in the elastic scattering. For the (10)Be + (12)C system, bound states coupled-channels calculations were considered. Moreover, total reaction cross sections were deduced from the elastic scattering analysis and compared with published data on other weakly and tightly bound projectiles elastically scattered on the (12)C target, as a function of energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the first measurements of identified hadron production, azimuthal anisotropy, and pion interferometry from Au + Au collisions below the nominal injection energy at the BNL Relativistic Heavy-Ion Collider (RHIC) facility. The data were collected using the large acceptance solenoidal tracker at RHIC (STAR) detector at root s(NN) = 9.2 GeV from a test run of the collider in the year 2008. Midrapidity results on multiplicity density dN/dy in rapidity y, average transverse momentum < p(T)>, particle ratios, elliptic flow, and Hanbury-Brown-Twiss (HBT) radii are consistent with the corresponding results at similar root s(NN) from fixed-target experiments. Directed flow measurements are presented for both midrapidity and forward-rapidity regions. Furthermore the collision centrality dependence of identified particle dN/dy, < p(T)>, and particle ratios are discussed. These results also demonstrate that the capabilities of the STAR detector, although optimized for root s(NN) = 200 GeV, are suitable for the proposed QCD critical-point search and exploration of the QCD phase diagram at RHIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Angular distributions for the (9)Be((8)Li, (9)Be) (8)Li elastic-transfer reaction have been measured with a 27-MeV (8)Li radioactive nuclear beam. Spectroscopic factors for the <(9)Be vertical bar(8)Li + p > bound system were obtained from the comparison between the experimental differential cross sections and finite-range distorted-wave Born approximation calculations made with the code FRESCO. The spectroscopic factors so obtained are compared with shell-model calculations and other experimental values. Using the present value for the spectroscopic factors, cross sections and reaction rates for the (8)Li(p,gamma) (9)Be direct proton-capture reaction of astrophysical interest were calculated in the framework of the potential model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New data for the (6)He + (9)Be reaction at E(1ab) = 16.2 and 21.3 MeV have been taken and analyzed. The effect of the collective couplings to the excited states of the target has been studied by means of coupled-channels calculations, using a double-folding potential for the bare interaction between the colliding nuclei, supplemented with a phenomenological imaginary part of Woods-Saxon type. In addition, three- and four-body continuum-discretized coupled-channels calculations have been performed to investigate the effect of the projectile breakup on the elastic scattering. Both effects, the coupling to target and projectile excited states, are found to affect significantly the elastic scattering. The trivial local polarization potential extracted from the continuum-discretized coupled-channels calculations indicates that continuum couplings produce a repulsive real part and a long-range imaginary part in the projectile-target interaction.