36 resultados para CALORIMETERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Main Injector Neutrino Oscillation Search (MINOS) experiment uses an accelerator-produced neutrino beam to perform precision measurements of the neutrino oscillation parameters in the ""atmospheric neutrino"" sector associated with muon neutrino disappearance. This long-baseline experiment measures neutrino interactions in Fermilab`s NuMI neutrino beam with a near detector at Fermilab and again 735 km downstream with a far detector in the Soudan Underground Laboratory in northern Minnesota. The two detectors are magnetized steel-scintillator tracking calorimeters. They are designed to be as similar as possible in order to ensure that differences in detector response have minimal impact on the comparisons of event rates, energy spectra and topologies that are essential to MINOS measurements of oscillation parameters. The design, construction, calibration and performance of the far and near detectors are described in this paper. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare, in patients with cancer and in healthy subjects, measured resting energy expenditure (REE) from traditional indirect calorimetry to a new portable device (MedGem) and predicted REE. DESIGN: Cross-sectional clinical validation study. SETTING: Private radiation oncology centre, Brisbane, Australia. SUBJECTS: Cancer patients (n = 18) and healthy subjects (n = 17) aged 37-86 y, with body mass indices ranging from 18 to 42 kg/m(2). INTERVENTIONS: Oxygen consumption (VO(2)) and REE were measured by VMax229 (VM) and MedGem (MG) indirect calorimeters in random order after a 12-h fast and 30-min rest. REE was also calculated from the MG without adjustment for nitrogen excretion (MGN) and estimated from Harris-Benedict prediction equations. Data were analysed using the Bland and Altman approach, based on a clinically acceptable difference between methods of 5%. RESULTS: The mean bias (MGN-VM) was 10% and limits of agreement were -42 to 21% for cancer patients; mean bias -5% with limits of -45 to 35% for healthy subjects. Less than half of the cancer patients (n = 7, 46.7%) and only a third (n = 5, 33.3%) of healthy subjects had measured REE by MGN within clinically acceptable limits of VM. Predicted REE showed a mean bias (HB-VM) of -5% for cancer patients and 4% for healthy subjects, with limits of agreement of -30 to 20% and -27 to 34%, respectively. CONCLUSIONS: Limits of agreement for the MG and Harris Benedict equations compared to traditional indirect calorimetry were similar but wide, indicating poor clinical accuracy for determining the REE of individual cancer patients and healthy subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O escopo desse trabalho é a observação de dijatos de difração simples em colisões pp com ps = 7 TeV, durante os primeiros períodos de aquisição de dados do experimento CMS/LHC. A técnica utilizada foi a medida da multiplicidade no calorímetro HF. Os dados foram analisados para diferentes períodos de aquisição de dados do ano de 2010, com ∫ Ldt ~_ 3,2 pb-1. Comparamos os dados observados com o Monte Carlo simulado com efeito de empilhamento e sem esse efeito.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La synthèse de siliciures métalliques sous la forme de films ultra-minces demeure un enjeu majeur en technologie CMOS. Le contrôle du budget thermique, afin de limiter la diffusion des dopants, est essentiel. Des techniques de recuit ultra-rapide sont alors couramment utilisées. Dans ce contexte, la technique de nanocalorimétrie est employée afin d'étudier, in situ, la formation en phase solide des siliciures de Ni à des taux de chauffage aussi élevés que 10^5 K/s. Des films de Ni, compris entre 9.3 et 0.3 nm sont déposés sur des calorimètres avec un substrat de a-Si ou de Si(100). Des mesures de diffraction de rayons X, balayées en température à 3 K/s, permettent de comparer les séquences de phase obtenues à bas taux de chauffage sur des échantillons de contrôle et à ultra-haut taux de chauffage sur les calorimètres. En premier lieu, il est apparu que l'emploi de calorimètres de type c-NC, munis d'une couche de 340 nm de Si(100), présente un défi majeur : un signal endothermique anormal vient fausser la mesure à haute température. Des micro-défauts au sein de la membrane de SiNx créent des courts-circuits entre la bande chauffante de Pt du calorimètre et l'échantillon métallique. Ce phénomène diminue avec l'épaisseur de l'échantillon et n'a pas d'effet en dessous de 400 °C tant que les porteurs de charge intrinsèques au Si ne sont pas activés. Il est possible de corriger la mesure de taux de chaleur en fonction de la température avec une incertitude de 12 °C. En ce qui a trait à la formation des siliciures de Ni à ultra-haut taux de chauffage, l'étude montre que la séquence de phase est modifiée. Les phases riches en m étal, Ni2Si et théta, ne sont pas détectées sur Si(100) et la cinétique de formation favorise une amorphisation en phase solide en début de réaction. Les enthalpies de formation pour les couches de Ni inférieures à 10 nm sont globalement plus élevées que dans le cas volumique, jusqu' à 66 %. De plus, les mesures calorimétriques montrent clairement un signal endothermique à haute température, témoignant de la compétition que se livrent la réaction de phase et l'agglomération de la couche. Pour les échantillons recuits a 3 K/s sur Si(100), une épaisseur critique telle que décrite par Zhang et Luo, et proche de 4 nm de Ni, est supposée. Un modèle est proposé, basé sur la difficulté de diffusion des composants entre des grains de plus en plus petits, afin d'expliquer la stabilité accrue des couches de plus en plus fines. Cette stabilité est également observée par nanocalorimétrie à travers le signal endothermique. Ce dernier se décale vers les hautes températures quand l'épaisseur du film diminue. En outre, une 2e épaisseur critique, d'environ 1 nm de Ni, est remarquée. En dessous, une seule phase semble se former au-dessus de 400 °C, supposément du NiSi2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to measure effects of 3-nitrooxypropanol (3NP) on methane production of lactating dairy cows and any associated changes in digestion and energy and nitrogen metabolism. Six Holstein-Friesian dairy cows in mid-lactation were fed twice daily a total mixed ration with maize silage as the primary forage source. Cows received 1 of 3 treatments using an experimental design based on two 3 × 3 Latin squares with 5-wk periods. Treatments were a control placebo or 500 or 2,500 mg/d of 3NP delivered directly into the rumen, via the rumen fistula, in equal doses before each feeding. Measurements of methane production and energy and nitrogen balance were obtained during wk 5 of each period using respiration calorimeters and digestion trials. Measurements of rumen pH (48 h) and postprandial volatile fatty acid and ammonia concentrations were made at the end of wk 4. Daily methane production was reduced by 3NP, but the effects were not dose dependent (reductions of 6.6 and 9.8% for 500 and 2,500 mg/d, respectively). Dosing 3NP had a transitory inhibitory effect on methane production, which may have been due to the product leaving the rumen in liquid outflow or through absorption or metabolism. Changes in rumen concentrations of volatile fatty acids indicated that the pattern of rumen fermentation was affected by both doses of the product, with a decrease in acetate:propionate ratio observed, but that acetate production was inhibited by the higher dose. Dry matter, organic matter, acid detergent fiber, N, and energy digestibility were reduced at the higher dose of the product. The decrease in digestible energy supply was not completely countered by the decrease in methane excretion such that metabolizable energy supply, metabolizable energy concentration of the diet, and net energy balance (milk plus tissue energy) were reduced by the highest dose of 3NP. Similarly, the decrease in nitrogen digestibility at the higher dose of the product was associated with a decrease in body nitrogen balance that was not observed for the lower dose. Milk yield and milk fat concentration and fatty acid composition were not affected but milk protein concentration was greater for the higher dose of 3NP. Twice-daily rumen dosing of 3NP reduced methane production by lactating dairy cows, but the dose of 2,500 mg/d reduced rumen acetate concentration, diet digestibility, and energy supply. Further research is warranted to determine the optimal dose and delivery method of the product. Key words: 3-nitrooxypropanol, methane, digestion, rumen, dairy cow

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Differential scanning calorimetry (DSC) studies were performed for 60/40 P(VDF-TrFE). The results not only confirm the importance of thermal history but also show that the samples with various configurations in terms of ferroelectric phases can be obtained via thermal treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the results of a search for the flavor-changing neutral current decay Bs 0 → μ+ μ-. using a data set with integrated luminosity of 240 pb-1 of pp̄ collisions at √s = 1.96 TeV collected with the D0 detector in run II of the Fermilab Tevatron collider. We find the upper limit on the branching fraction to be B(Bs 0 → μ+ π-) ≤ 5.0 × 10-7 at the 95% C.L. assuming no contributions from the decay Bd 0 → μ+ μ- in the signal region. This limit is the most stringent upper bound on the branching fraction Bs 0 → μ+ μ- to date. © 2005 The American Physical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Biofísica Molecular - IBILCE