998 resultados para Bonding technique
Resumo:
We successfully used the metal mediated-wafer bonding technique in transferring the as-grown cubic GaN LED structure of Si substrate. The absorbing GaAs substrate was removed by using the chemical solutions of NH4OH : H2O2=1 : 10. SEM and PL results show that wafer bonding technique could transfer the cubic GaN epilayers uniformly to Si without affecting the physical and optical properties of epilayers. XRD result shows that there appeared new peaks related to AgGa2 and Ni4N diffraction, indicating that the metals used as adhesive and protective layers interacted with the p-GaN layer during the long annealing process. It is just the reaction that ensures the reliability of the integration of GaN with metal and minor contact resistance on the interface.
Resumo:
O objetivo deste ensaio clínico randomizado foi avaliar o comportamento clínico das restaurações adesivas, usando um adesivo convencional de três passos (CTP), um adesivo autocondicionante de um passo (AUP) e uma técnica simplificada da adesão úmida por etanol (AUET) antes da aplicação de uma resina composta em lesões cervicais não-cariosas. Noventa e três restaurações (31 para cada grupo) foram realizadas em 17 pacientes por um único operador. Nenhum preparo cavitário foi realizado. Depois de 6 e 12 meses, as restaurações foram avaliadas por 2 examinadores previamente treinados, utilizando critérios de Ryge modificados para retenção (kappa=1,00) e adaptação/manchamento marginal (kappa=0,81), e os resultados foram analisados pelos testes Exato de Fisher e Kruskal-Wallis, respectivamente. Não foram observadas diferenças significativas entre os grupos aos 6 e 12 meses para qualquer um dos critérios avaliados (p≥0,05). A análise intra-grupo feita pelos testes Q de Cochran (para retenção) e Wilcoxon (para adaptação/manchamento marginal) revelou diferenças significativas entre os intervalos de tempo baseline/12 meses para a adaptação marginal no AUP (p=0,0180) e manchamento marginal no CTP (p=0,0117). A análise de sobrevivência para o critério retenção realizada utilizando o teste de log-rank não apresentou diferenças significantes (p≥0,05). As restaurações feitas utilizando a técnica simplificada da adesão úmida por etanol comportaram-se igualmente às outras estratégias adesivas empregadas.
Resumo:
To evaluate the short-term response of human pulps to ethanol-wet bonding technique. Methods Deep class V cavities were prepared on 17 sound premolars and divided into three groups. After acid-etching, the cavities from groups 1 (G1) and 2 (G2) were filled with 100% ethanol or distilled water, respectively, for 60 s before the application of Single Bond 2. In group 3 (G3, control), the cavity floor was lined with calcium hydroxide before etching and bonding. All cavities were restored with resin composite. Two teeth were used as intact control. The teeth were extracted 48 h after the clinical procedures. From each tooth serial sections were obtained and stained with haematoxylin and eosin (H/E) and Masson's trichrome. Bacteria microleakage was assessed using Brown & Brenn. All sections were blindly evaluated for five histological features. Results Mean remaining dentine thickness was 463 ± 65 μm (G1); 425 ± 184 μm (G2); and 348 ± 194 μm (G3). Similar pulp reactions followed ethanol- or water-wet bonding techniques. Slight inflammatory responses and disruption of the odontoblast layer related to the cavity floor were seen in all groups. Stained bacteria were not detected in any cavities. Normal pulp tissue was observed in G3 except for one case. Conclusions After 48 h, ethanol-wet bonding does not increase pulpal damage compared to water-wet bonding technique. Clinical significance Ethanol-wet bonding may increase resin-dentine bond durability. This study reported the in vivo response of human pulp tissue when 100% ethanol was applied previously to an etch-and-rinse simplified adhesive system.
Resumo:
Anodic bonding of Pyrex glass/Al/Si is an important bonding technique in micro/nanoelectromechanical systems (MEMS/NEMS) industry. The anodic bonding of Pyrex 7740 glass/Aluminum film/Silicon is completed at the temperature from 300 degrees C to 375 degrees C with a bonding voltage between 150 V and 450 V. The fractal patterns are formed in the intermediate Al thin film. This pattern has the fractal dimension of the typical two-dimensional diffusion-limited aggregation (2D DLA) process, and the fractal dimension is around 1.7. The fractal patterns consist of Al and Si crystalline grains, and their occurrences are due to the limited diffusion, aggregation, and crystallization of Si and Al atoms in the intermediate Al layers. The formation of the fractal pattern is helpful to enhance the bonding strength between the Pyrex 7740 glass and the aluminum thin film coated on the crystal silicon substrates.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study examined the immediate bond strength of etch-and-rinse adhesives to demineralized dentin saturated with either water or absolute ethanol. The research hypothesis was that there would be no difference in bond strength to dentin between water or ethanol wet-bonding techniques. The medium dentin of 20 third molars was exposed (n = 5). The dentin surface was then acid-etched, left moist and randomly assigned to be saturated via either water wet-bonding (WBT) or absolute ethanol wet-bonding (EBT). The specimens were then treated with one of the following etch-and-rinse adhesive systems: a 3-step, water-based system (Adper Scotchbond Multipurpose, or SBMP) or a 2-step, ethanol/water-based system (Adper Single Bond 2, or SB). Resin composite build-ups were then incrementally constructed. After water storage for 24 h at 37 degrees C, the tensile strength of the specimens was tested in a universal testing machine (0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey's test (alpha = 5%). The failure modes were verified using a stereomicroscope (40x). For both adhesives, no significant difference in bond strength was observed between WBT and EBT (p > 0.05). The highest bond strength was observed for SB, regardless of the bonding technique (p < 0.05). No significant interaction between adhesives and bonding techniques was noticed (p = 0.597). There was a predominance of adhesive failures for all tested groups. The EBT and WBT displayed similar immediate bond strength means for both adhesives. The SB adhesive exhibited higher means for all conditions tested. Further investigations are needed to evaluate long-term bonding to dentin mediated by commercial etch-and-rinse adhesives using the EBT approach.
Resumo:
Objective: This study evaluated the performance of different adhesive systems in fiber post placement aiming to clarify the influence of different hydrophobic experimental blend adhesives, and of one commercially available adhesive on the frictional retention during a luting procedure. Material and Methods: One luting agent (70 Wt% BisGMA, 28.5% TEGDMA; 1.5% p-tolyldiethanolamine) to cement fiber posts into root canals was applied with 4 different adhesive combinations: Group 1: The etched roots were rinsed with water for 30 s to remove the phosphoric acid, then rinsed with 99.6% ethanol for 30 s, and blot-dried. A trial adhesive (base to catalyst on a 1: 1 ratio) was used with an experimental luting agent (35% Bis-GMA, 14.37% TEGDMA, 0.5% EDMAB, 0.13% CQ); Group 2: A trial adhesive (base to catalyst on a 1: 2 ratio) was luted as in Group 1; Group 3: One-Step Plus (OSP, Bisco Inc.) following the ethanol bonding technique in combination with the luting agent as in Group 1; Group 4: OSP strictly following the manufacturer's instructions using the luting agent as in Group 1. The groups were challenged with push-out tests. Posted root slices were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under scanning electron microscopy. Results: Push-out strength was not significantly influenced by the luting agent (p>0.05). No statistically significant differences among the tested groups were found as Group 1 (Exp 1 - ethanol-wet bonding technique)=Group 2 (Exp 2 - ethanol-wet bonding technique)= Group 3 (OSP - ethanol-wet bonding technique)= Group 4 (control, OSP - water-wet bonding technique) (p>0.05). The dominating failure modes in all the groups were cohesive/adhesive failures, which were predominantly observed on the post/luting agent interface. Conclusions: The results of this study support the hypothesis that the proposal to replace water with ethanol to bond fiber posts to the root canal using highly hydrophobic resin is plausible, but this seems to be more the proof of a concept than a clinically applicable procedure.
Resumo:
AIM: To evaluate the bond strength of brackets fixed with different materials (two light-cured nanofilled resins - Transbond Supreme LV and Flow Tain LV, a light-cured resin - Transbond XT (control) and two chemically cured resins for indirect bonding - Sondhi Rapid- Set and Custom I.Q.) using the indirect bonding technique after 10 min and 24 h, and evaluate the type of failure. METHODS: One hundred premolars were selected and randomly divided into groups (n=10) according to the material and fixation period. The brackets were bonded through the indirect technique following the manufacturer's instructions and stored in deionized water at 37°C for 10 min or 24 h. After, the specimens were submitted to a shear bond strength (SBS) test (Instron) at 0.5 mm/min and evaluated for adhesive remnant index (ARI). The data were submitted to ANOVA and Tukey's test (p<0.05) and the ARI scores were submitted to the chi-square test. RESULTS: It could be observed a significant difference among the materials (Flow Tain LV = Transbond Supreme LV = Transbond XT> Sondhi Rapid-Set > Custom I.Q.). There was no significant difference in resistance values between 10 min and 24 h, regardless of the materials. Most groups showed adhesive remaining adhered to the enamel (scores 2 and 3) without statistically significant difference (p>0.05). CONCLUSIONS: It was concluded that the light-cured nanofilled materials used in indirect bonding showed greater resistance than the chemically cured materials. The period of fixation had no influence on the resistance for different materials.
Resumo:
The Principle of optical thin film was used to calculate the feasibility of improving the light extraction efficiency of GaN/GaAs optical devices by wafer-bonding technique. The calculated results show that the light extraction efficiency of bonded samples can be improved by 2.66 times than the as-grown GaN/GaAs samples when a thin Ni layer was used as adhesive layer and Ag layer as reflective layer. Full reflectance spectrum comparison shows that reflectivity for the incident light of 459.2 nm of the bonded samples was improved by 2.4 times than the as-grown samples, which is consistent with the calculated results.
Resumo:
The Principle of optical thin film was used to calculate the feasibility of improving the light extraction efficiency of GaN/GaAs optical devices by wafer-bonding technique. The calculated results show that the light extraction efficiency of bonded samples can be improved by 2.66 times than the as-grown GaN/GaAs samples when a thin Ni layer was used as adhesive layer and Ag layer as reflective layer. Full reflectance spectrum comparison shows that reflectivity for the incident light of 459.2 nm of the bonded samples was improved by 2.4 times than the as-grown samples, which is consistent with the calculated results.
Resumo:
O uso de ligações adesivas aumentou significativamente nos últimos anos e é hoje em dia uma técnica de ligação dominante na indústria aeronáutica e automóvel. As ligações adesivas visam substituir os métodos tradicionais de fixação mecânicos na união de estruturas. A melhoria ao longo dos anos de vários modelos de previsão de dano, nomeadamente através do Método de Elementos Finitos (MEF), tem ajudado ao desenvolvimento desta técnica de ligação. Os Modelos de Dano coesivo (MDC), usados em conjunto com MEF, são uma ferramenta viável para a previsão de resistência de juntas adesivas. Os MDC combinam critérios da resistência dos materiais para a iniciação do dano e conceitos da mecânica da fratura para a propagação da fenda. Existem diversas formas de leis coesivas possíveis de aplicar em simulações por MDC, em função do comportamento expectável dos materiais que estão a ser simulados. Neste trabalho, estudou-se numericamente o efeito de diversas formas de leis coesivas na previsão no comportamento de juntas adesivas, nomeadamente nas curvas forçadeslocamento (P-) de ensaios Double-Cantilever Beam para caracterização à tração e ensaios End-Notched Flexure para caraterização ao corte. Também se estudou a influência dos parâmetros coesivos à tração e corte nas curvas P- dos referidos ensaios. Para o Araldite®AV138 à tração e ao corte, a lei triangular é a que melhor prevê o comportamento do adesivo. Para a previsão da resistência de ambos os adesivos Araldite® 2015 e SikaForce® 7752, a lei trapezoidal é a que melhor se adequa, confirmando assim que esta lei é a que melhor caracteriza o comportamento de dano de adesivos tipicamente dúcteis. O estudo dos parâmetros revelou influência distinta na previsão do comportamento das juntas, embora com bastantes semelhanças entre os diferentes tipos de adesivos.
Resumo:
Introduction : Après un traitement orthodontique, la rétention (ou contention) est essentielle pour éviter les récidives vers la malocclusion initiale. Le fil de rétention lingual est un appareil fixe, relativement facile à installer et bien accepté par les patients pour maintenir la position finale des dents antérieures inférieures. Étant de plus en plus utilisé, il devient important de s’assurer de sa fiabilité pour la stabilité de l’alignement dentaire. Objectif : Le but de cette étude clinique randomisée prospective est de déterminer le taux de survie d’un fil lingual mandibulaire de rétention en comparant les méthodes de collage direct et de collage indirect à court et moyen termes. Méthodologie : L’échantillon est constitué de 117 patients consécutifs aléatoirement distribués dans 2 groupes : collage direct (n=58) et collage indirect (n=59). Les fils torsadés de diamètre 0,0175’’ sont préformés par un technicien de laboratoire soit selon la méthode de collage direct, soit selon la méthode de collage indirect. Une matrice de transfert en silicone assure le positionnement précis du fil lingual en bouche. Assure® et Filtek™ Flow ont été utilisés pour le collage direct. Filtek™ Flow, Assure®, and Sondhi™ ont été utilisés pour le collage indirect. Les fils de rétention ont été évalués pour le décollement, l’infiltration, la distorsion et le bris à 2 mois (T1) et 6 mois (T2). Résultats : À T1, le taux de survie du fil de rétention est de 90,2% pour le groupe de collage direct, comparativement à 79,5% pour le groupe de collage indirect (p=0,232). À T2, le fil est resté intact pour 74,1% des participants dans le groupe de collage direct et pour 70,0% des participants dans le groupe de collage indirect (p=0,481). Les différences ne sont pas statistiquement significatives entre les 2 groupes. La fréquence du décollement est plus haute que les autres problèmes enregistrés à T1 (p<0,022), représentant 85,7% des échecs. À T2, le décollement est plus fréquent que la distorsion ou le bris (p<0,04), mais pas statistiquement plus fréquent que l’infiltration (p=0,109). Il représente alors 86,4% des échecs. Conclusion : Le décollement est la principale cause d’échec d’un fil de rétention lingual. Il n’y a pas de différence statistiquement significative du taux de survie d’un fil lingual mandibulaire de rétention entre les techniques de collage direct et de collage indirect à court et moyen termes.
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Besides possessing good mechanical properties, dental materials should present a good biological behavior and should not injure the involved tissues. Bond strength and biocompatibility are both highly significant properties of dentin adhesives. For that matter, these properties of four generations of adhesive systems (Multi-Purpose/Single Bond/SE Plus/Easy Bond) were evaluated.Eighty bovine teeth had their dentin exposed (500- and 200-mu m thickness). Adhesive was applied on the dentin layer of each specimen. Following that, the microshearing test was performed for all samples. A dentin barrier test was used for the cytotoxicity evaluation. Cell cultures (SV3NeoB) were collected from testing materials by means of 200- or 500-mu m-thick dentin slices and placed in a cell culture perfusion chamber. Cell viability was measured 24 h post-exposition by means of a photometrical test (MTT test).The best bonding performance was shown by the single-step adhesive Easy Bond (21 MPa, 200 mu m; 27 MPa, 500 mu m) followed by Single Bond (15.6 MPa, 200 mu m; 23.4 MPa, 500 mu m), SE Plus (18.2 MPa, 200 mu m; 20 MPa, 500 mu m), and Multi-Purpose (15.2 MPa, 200 mu m; 17.9 MPa, 500 mu m). Regarding the cytotoxicity, Multi-Purpose slightly reduced the cell viability to 92 % (200 mu m)/93 % (500 mu m). Single Bond was reasonably cytotoxic, reducing cell viability to 71 % (200 mu m)/64 % (500 mu m). The self-etching adhesive Scotchbond SE decreased cell viability to 85 % (200 mu m)/71 % (500 mu m). Conversely, Easy Bond did not reduce cell viability in this test, regardless of the dentin thickness.Results showed that the one-step system had the best bond strength performance and was the least toxic to pulp cells. In multiple-step systems, a correct bonding technique must be done, and a pulp capping strategy is necessary for achieving good performance in both properties.The study showed a promising system (one-step self-etching), referring to it as a good alternative for specific cases, mainly due to its technical simplicity and good biological responses.