923 resultados para Blood pressure determination, instrumentation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The blood pressure waveform is modified on distal propagation by phenomena such as dispersion, reflection and the state of the arterial compliance. The consequent effects are amplification and narrowing of the wave, with an increased systolic, reduced diastolic and essentially unaltered mean blood pressure. The Finapres measures the peripheral pressure using the volume clamp principle; it has not been validated under altered physiological conditions and during pharmacodynamic interventions. We studied simultaneous Finapres and brachial blood pressures (using a conventional oscillometric sphygmomanometer—Vitalmap) in ten normal volunteers at rest, and during dynamic exercise and a cold pressor test. The effects of pharmacodynamic intervention were examined following beta-adrenoceptor blockade with propranolol (160 mg) or beta-adrenoceptor modulation with the beta-adrenoceptor partial agonist celiprolol (400 mg). The Finapres systolic pressure was significantly higher than the brachial value during all three test states. The difference between the systolic pressures measured by the two devices was shown to increase significantly during the cold pressor test, but not during dynamic (supine bicycle) exercise. The Finapres diastolic pressure was significantly higher than the Vitalmap value during exercise and the cold pressor test. The differences between the two methods increased significantly over time. Beta-adrenergic blockade with propranolol or modulation with celiprolol had no significant interaction with the pressure differences between the Finapres and Vitalmap techniques. The results would support the view that the Finapres can provide blood pressure information which is robust under most circumstances. Although this pharmacodynamic intervention did not alter the relationship between the peripheral and central blood pressure, it is important to note that this dynamic relationship is sensitive to circulatory loading conditions and wave transmission characteristics; it is possible that the Finapres could be less reliable in clinical settings where potent vasoactive agents were being administered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ambulatory blood pressure profiles were obtained with the portable semi-automatic blood pressure recorder Remler M2000 in groups of 20 adolescents, 20 young and 20 middle-aged adults and 20 elderly untreated patients, all considered by their physician to be hypertensive. It was found that adolescents who are hypertensive when seeing their physician are more often normotensive outside the physician's office than adult and elderly patients under similar conditions. The increased heart rate variability which was detected in adolescents was not associated with an enhanced blood pressure variability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little information exists regarding the effect of several obesity markers on blood pressure (BP) levels in youth. Transverse study including 2494 boys and 2589 girls. Height, weight and waist were measured according to the international criteria and body fat (BF) by bioimpedance. BP was measured by an automated device. Hypertension was defined using sex-specific, age-specific and height-specific observation-points. Body mass index (BMI) and waist were positively related with systolic blood pressure (SBP) and diastolic blood pressure (DBP) and heart rate in both sexes, whereas the relationships with BF were less consistent. Stepwise linear regression analysis showed that BMI was positively related with SBP and DBP in both sexes, whereas BF was negatively related with SBP in both sexes and with heart rate in boys only; finally, waist was positively related with SBP in boys and heart rate in girls. Age and heart rate-adjusted values of SBP and DBP increased with BMI: for SBP, 117+/-1, 123+/-1 and 124+/-1 mmHg in normal, overweight and obese boys, respectively; corresponding values for girls were 111+/-1, 114+/-1 and 116+/-2 mmHg (mean+/-SE, P<0.001). Overweight and obese boys had an odds ratio for being hypertensive of 2.26 (95% confidence interval: 1.79-2.86) and 3.36 (2.32-4.87), respectively; corresponding values for girls were 1.58 (confidence interval 1.25-1.99) and 2.31 (1.53-3.50). BMI, not BF or waist, is consistently and independently related to BP levels in children; overweight and obesity considerably increase the risk of hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to assess the effects of physical fitness on the relationships between body mass index (BMI) and body fat (BF) on blood pressure (BP) levels. Cross-sectional study conducted in 25 schools of Lisbon (Portugal), including 2041 boys and 1995 girls aged 10-18. BF was assessed by bioimpedance. Cardiovascular fitness was assessed by the 20-meter shuttle run and classified as fit/unfit. Obesity (BMI or BF defined) was defined according to international criteria. In both sexes, BMI was positively related with systolic and diastolic BP, while BF was only positively related with diastolic BP z-scores. No interaction was found between fitness and BMI categories regarding BP levels, while for BF a significant interaction was found. Being fit reduced the BF-induced increase in the Odds ratio (OR) of presenting with high BP: OR (95% confidence interval) 1.01 (0.73-1.40) and 0.99 (0.70-1.38) for overweight and obese fit boys, respectively, the corresponding values for unfit overweight and obese boys being 1.33 (0.94-1.90) and 1.75 (1.34-2.28), respectively. The values were 0.88 (0.57-1.35) and 1.66 (0.98-2.80) for overweight and obese fit girls, respectively, the corresponding values for unfit overweight and obese being 1.63 (1.12-2.37) and 1.90 (1.32-2.73) respectively. No interaction was found between fitness and BMI-defined overweight and obesity. Being fit reduces the negative impact of BF on BP levels and high BP status in adolescents. This protective effect was not found with BMI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we assessed whether the white-coat effect (difference between office and daytime blood pressure (BP)) is associated with nondipping (absence of BP decrease at night). Data were available in 371 individuals of African descent from 74 families selected from a population-based hypertension register in the Seychelles Islands and in 295 Caucasian individuals randomly selected from a population-based study in Switzerland. We used standard multiple linear regression in the Swiss data and generalized estimating equations to account for familial correlations in the Seychelles data. The prevalence of systolic and diastolic nondipping (<10% nocturnal BP decrease) and white-coat hypertension (WCH) was respectively 51, 46, and 4% in blacks and 33, 37, and 7% in whites. When white coat effect and nocturnal dipping were taken as continuous variables (mm Hg), systolic (SBP) and diastolic BP (DBP) dipping were associated inversely and independently with white-coat effect (P < 0.05) in both populations. Analogously, the difference between office and daytime heart rate was inversely associated with the difference between daytime and night-time heart rate in the two populations. These results did not change after adjustment for potential confounders. The white-coat effect is associated with BP nondipping. The similar associations between office-daytime values and daytime-night-time values for both BP and heart rate suggest that the sympathetic nervous system might play a role. Our findings also further stress the interest, for clinicians, of assessing the presence of a white-coat effect as a means to further identify patients at increased cardiovascular risk and guide treatment accordingly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Estimated central systolic blood pressure (cSBP) and amplification (Brachial SBP-cSBP) are non-invasive measures potentially prognostic of cardiovascular (CV) disease. No worldwide, multiple-device reference values are available. We aimed to establish reference values for a worldwide general population standardizing between the different available methods of measurement. How these values were significantly altered by cardiovascular risk factors (CVRFs) was then investigated. METHODS AND RESULTS: Existing data from population surveys and clinical trials were combined, whether published or not. Reference values of cSBP and amplification were calculated as percentiles for 'Normal' (no CVRFs) and 'Reference' (any CVRFs) populations. We included 45,436 subjects out of 82,930 that were gathered from 77 studies of 53 centres. Included subjects were apparently healthy, not treated for hypertension or dyslipidaemia, and free from overt CV disease and diabetes. Values of cSBP and amplification were stratified by brachial blood pressure categories and age decade in turn, both being stratified by sex. Amplification decreased with age and more so in males than in females. Sex was the most powerful factor associated with amplification with 6.6 mmHg (5.8-7.4) higher amplification in males than in females. Amplification was marginally but significantly influenced by CVRFs, with smoking and dyslipidaemia decreasing amplification, but increased with increasing levels of blood glucose. CONCLUSION: Typical values of cSBP and amplification in a healthy population and a population free of traditional CVRFs are now available according to age, sex, and brachial BP, providing values included from different devices with a wide geographical representation. Amplification is significantly influenced by CVRFs, but differently in men and women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atualmente, diante das técnicas atuais, a manometria tem sido relegada a plano secundário durante a cateterização cardíaca. No entanto, ainda fornece importantes informações para identificação e avaliação das doenças cardiovasculares. Os dados coletados durante os exames possibilitam a obtenção de variáveis quantitativas e qualitativas, as quais podem ser comparadas aos padrões normais. Os sistemas manométricos são compostos por transdutor, amplificador e registrador, que, em conjunto, devem espelhar com fidelidade a morfologia e os valores das variáveis analisadas. Para atingir esse objetivo, é necessário desempenho adequado de todos os componentes. Se uma determinada informação é de extrema relevância, o operador deve gastar tempo suficiente para obtê-la de maneira inequívoca. Assim, o operador deve estar familiarizado com os sistemas manométricos e com as fontes de erro relacionadas com as técnicas de registro, cateteres, conectores e fluidos. Com os fundamentos analisados neste manuscrito, salientamos que deve ser dispensada atenção às ondas de pressão usadas nas interpretações da fisiopatologia das doenças cardiovasculares.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To examine the combined effects of physical activity and weight status on blood pressure (BP) in preschool-aged children. Study design The sample included 733 preschool-aged children (49% female). Physical activity was objectively assessed on 7 consecutive days by accelerometry. Children were categorized as sufficiently active if they met the recommendation of at least 60 minutes daily of moderate-to-vigorous physical activity (MVPA). Body mass index was used to categorize children as nonoverweight or overweight/obese, according to the International Obesity Task Force benchmarks. BP was measured using an automated BP monitor and categorized as elevated or normal using BP percentile-based cut-points for age, sex, and height. Results The prevalence of elevated systolic BP (SBP) and diastolic BP was 7.7% and 3.0%, respectively. The prevalence of overweight/obese was 32%, and about 15% of children did not accomplish the recommended 60 minutes of daily MVPA. After controlling for age and sex, overweight/obese children who did not meet the daily MVPA recommendation were 3 times more likely (OR 3.8; CI 1.6-8.6) to have elevated SBP than nonoverweight children who met the daily MVPA recommendation. Conclusions Overweight or obese preschool-aged children with insufficient levels of MVPA are at significantly greater risk for elevated SBP than their nonoverweight and sufficiently active counterparts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a blood pressure evaluation methodology by recording the radial arterial pulse waveform in real time using a fiber Bragg grating pulse device (FBGPD). Here, the pressure responses of the arterial pulse in the form of beat-to-beat pulse amplitude and arterial diametrical variations are monitored. Particularly, the unique signatures of pulse pressure variations have been recorded in the arterial pulse waveform, which indicate the systolic and diastolic blood pressure while the patient is subjected to the sphygmomanometric blood pressure examination. The proposed method of blood pressure evaluation using FBGPD has been validated with the auscultatory method of detecting the acoustic pulses (Korotkoff sounds) by an electronic stethoscope. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a CMOS implementation of a linear voltage regulator (LVR) used to power up implanted physiological signal systems, as it is the case of a wireless blood pressure biosensor. The topology is based on a classical structure of a linear low-dropout regulator. The circuit is powered up from an RF link, thus characterizing a passive radio frequency identification (RFID) tag. The LVR was designed to meet important features such as low power consumption and small silicon area, without the need for any external discrete components. The low power operation represents an essential condition to avoid a high-energy RF link, thus minimizing the transmitted power and therefore minimizing the thermal effects on the patient's tissues. The project was implemented in a 0.35-mu m CMOS process, and the prototypes were tested to validate the overall performance. The LVR output is regulated at 1 V and supplies a maximum load current of 0.5 mA at 37 degrees C. The load regulation is 13 mV/mA, and the line regulation is 39 mV/V. The LVR total power consumption is 1.2 mW.