989 resultados para Blood Coagulation Tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43μg/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapport de synthèse : Contexte: l'hydroxyéthylamidon (HEA) est largement utilisé comme expanseur volémique en anesthésiologie et réanimation. Cependant, cette classe de produits perturbe le system de la coagulation. Des améliorations restent possibles dans le choix de la combinaison optimale de poids moléculaire, de degré de substitution en radicaux éthyle et de localisation de ces radicaux sur le squelette glucidique des polymères, afin d'optimiser leur efficacité et leur tolérance. L'HEA de poids moléculaire élevé et faiblement substitué n'affecte pas plus la coagulation sanguine que de l'HEA de bas poids moléculaire faiblement substitué. Nous examinons in vivo l'effet d'un abaissement du rapport C2/C6 sur les caractéristiques pharmacocinétiques et l'impact sur la coagulation sanguine d'un HEA de haut poids moléculaire faiblement substitué. Matériels et méthode: nous comparons dans une étude prospective, randomisée et parallèle l'HEA 650/0.42/2.8 avec l'HEA 650/0.42/5.6 auprès de 30 cochons. Avant, pendant et jusqu'à 630 minutes après une perfusion de 30 ml/kg d'HEA, des échantillons sanguins ont été collectés pour mesurer les concentrations d'HEA, les tests de coagulation plasmatique classiques et la coagulation sanguine par thrombélastographie (TEG®, Haemoscope Corporation, Niles, II, U.S.). Les paramètres pharmacocinétiques ont été estimés en adaptant un modèle à deux compartiments. Résultats: la constante d'élimination est de 0.009 ± 0.001 (min-1) pour l'HEA 650/0.42/2.8 et 0.007 ± 0.001 (min-1) pour l'HEA 650/0.42/5.6 (p<0.001); la surface sous la courbe de concentration est de 1374 ± 340 min*g/L pour l'HEA 650/0.42/2.8 et 1697 ± 411 min*g/L pour l'HEA 650/0.42/5.6 (p=0.026). Les concentrations mesurées d'HEA ne montrent pas de différence entre l'HEA 650/0.42/2.8 et l'HEA 650/0.42/5.6. Les deux solutions d'HEA affectent de façon identique la coagulation sanguine: l'index de coagulation thrombélastographique diminue pareillement à ta fin de la perfusion d'HEA 650/0.42/2.8 et d'HEA 650/0.42/5.6 (p=0.29). De même, le temps de thromboplastine partielle activée et le temps de prothrombine augmentent de manière similaire pour l'HEA 650/0.42/2.8 et l'HEA 650/0.42/5.6 (p=0.83). Conclusion: la réduction du rapport C2/C6 de l'HEA de poids moléculaire élevé et faiblement substitué aboutit à une élimination légèrement accélérée d'HEA. Cependant, elle ne modifie pas l'effet perturbateur sur la coagulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Activated protein C (APC) deC ciency is prevalent in severe sepsis and septic shock patients. The aim of the study was to relate the anticoagulation activity evaluated by APC with other coagulation parameters adjusted to 28-day mortality. Methods A cohort study of 150 critically ill adults. Age, sex, sources of infection and coagulation markers within 24< hours from severe sepsis or septic shock onset, deC ned according to Surviving Sepsis Campaign (SSC) criteria, were studied. We analyzed APC activity using a hemostasis laboratory analyzer (BCS® XP; Siemens). A descriptive and comparative statistical analysis was performed using SPSS version 15.0 (SPSS Inc., Chicago, IL, USA). Results We analyzed 150 consecutive episodes of severe sepsis (16%) or septic shock (84%) admitted to the UCI. The median age of the study sample was 64 (interquartile range (IQR): 22.3blood cultures. Spearman’s showed relationship with antithrombin III, r<= 0.674 (P <0.001) and International Normalized Ratio (INR), r<= –0.611 (P >0.001). See Figure 1. Conclusion Low levels of PC are associated with poor outcome and severity in severe sepsis, and it is well correlated with antithrombin III and INR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumé Cette étude a démontré l'effet individuel sur la coagulation sanguine humaine des deux principales caractéristiques de la molécule d'hydroxyéthylamidon (HES) : la substitution molaire et le rapport C2/C6. L'analyse par thrombélastographe (TEG®) indique que la molécule de HES dont la substitution molaire est de 0.42 et le rapport C2/C6 de 2.7 a le moins d'effet sur la coagulation sanguine chez l'être humain. Objectifs de l'étude Le développement d'hydroxyéthylamidons (HES) qui ont à la fois peu d'impact sur la coagulation sanguine et une longue persistance intravasculaire est d'un grand intérêt clinique. Une précédente étude in vitro a démontré qu'une solution de HES de haut poids moléculaire et de bas degré de substitution molaire ne compromettait pas plus la coagulation sanguine qu'une solution HES de poids moléculaire moyen (1). La présente étude examine l'effet individuel de la substitution molaire et du rapport C2/C6 d'une solution de HES de haut poids moléculaire (700 kDa) sur la coagulation sanguine. Matériel et méthode Nous avons prélevé du sang chez 30 adultes en bonne santé; le sang a été mélangé avec 6 solutions de HES qui diffèrent par leur degré de substitution molaire (0.42 et 0.51) et leur rapport C2/C6 (2.7, 7 et 14) à trois degrés de dilution : 20%, 40% et 60%. Les échantillons ont ensuite été analysés par thrombélastographe. Les données ont été étudiées par analyse de variance à trois voies pour mesures répétées sur une voie (dilution). Résultats Plus la substitution molaire est élevée, plus la coagulation sanguine est compromise et ce concernant tous les paramètres du TEG® (tous les p sont < à 0.05). La solution HES avec le rapport C2/C6 le plus bas a l'effet le moins prononcé sur le temps r (p<0.001), l'angle α (p=0.003) et l'Index de Coagulation CI (p<0.001) ; on n'a pas observé d'effet sur le temps k (p=0.513) et l'amplitude maximale (p=0.699) concernant ce paramètre. Conclusion L'analyse par thrombélastographe révèle qu'une molécule de HES avec une substitution molaire de 0.42 et un rapport C2/C6 de 2.7 a un effet minimal sur la coagulation sanguine humaine in vitro.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dietary alpha-linolenic acid (ALA) can be converted to long-chain (n-3) PUFA in humans and may potentially reproduce the beneficial effects of eicosapentaenoic (EPA) and docosahexaenoic (DHA) acids on risk factors for coronary heart disease (CHID). This study compared the effects of increased intakes of ALA with those of dietary EPA and DHA on blood coagulation and fibrinolytic factors in fasting subjects. A placebo-controlled, parallel study was conducted in 150 moderately hyperlipidemic subjects, age 25-72 y. Subjects were randomly assigned to one of five interventions and consumed a total intake of 0.8 or 1.7g/d EPA+DHA, 4.5 or 9.5g/d ALA or control (linoleic acid; LA) for 6 mo. Fatty acids were incorporated into 25 g of fat spread, which replaced the subject's normal spread and three capsules. Long-term supplementation with either dietary EPA+DHA or estimated biologically equivalent amounts of ALA did not affect factors VIIa, VIIc, VIIag, XIIa, XIIag, fibrinogen concentrations, plasminogen activator inhibitor-1 or tissue plasminogen activator activity compared with the control. (n-3) PUFA of plant or marine origin do not differ from one another or from LA in their effect on a range of blood coagulation and fibrinolytic factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review describes some natural proteins, which can be employed, either as factor concentrates derived from human plasma or as recombinant drug, to modulate the coagulation system. I will address some biochemical characteristics and the physiological role of von Willebrand factor, the coagulation factors of the extrinsic and intrinsic pathways, and the physiological anticoagulant protein C. In addition, I will detail the pharmacological compounds, which are available for influencing or substituting the coagulation proteins: desmopressin (DDAVP), single coagulation factor concentrates, prothrombin complex concentrates, and protein C concentrate. In particular, I will address some treatment topics of general medical interest, such as the treatment of massive bleeding, the correction of the coagulopathy induced by vitamin K-antagonists in patients with cerebral haemorrhage, and of the coagulopathy of meningococcemia. Finally, I will describe some properties and practical clinical applications of the recombinant anticoagulans lepirudin and bivalirudin, which are derived from hirudin, the natural anticoagulant of the medical leech.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43?g/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New oral anticoagulants promise to overcome essential drawbacks of traditional substances. They have a predictable therapeutic effect, a wide therapeutic window, only limited interaction with food and drugs and can be administered p.o. with a fixed dose. On the other hand, knowledge on the laboratory management of new anticoagulants is limited. In the present article we discuss possible indications and available assays for monitoring of Rivaroxaban, Apixaban and Dabigatran. Furthermore, we discuss interpretation of routine coagulation tests during therapy with these new drugs.