8 resultados para Biochips


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Droplet-based digital microfluidics technology has now come of age, and software-controlled biochips for healthcare applications are starting to emerge. However, today's digital microfluidic biochips suffer from the drawback that there is no feedback to the control software from the underlying hardware platform. Due to the lack of precision inherent in biochemical experiments, errors are likely during droplet manipulation; error recovery based on the repetition of experiments leads to wastage of expensive reagents and hard-to-prepare samples. By exploiting recent advances in the integration of optical detectors (sensors) into a digital microfluidics biochip, we present a physical-aware system reconfiguration technique that uses sensor data at intermediate checkpoints to dynamically reconfigure the biochip. A cyberphysical resynthesis technique is used to recompute electrode-actuation sequences, thereby deriving new schedules, module placement, and droplet routing pathways, with minimum impact on the time-to-response. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patterning nanostructures on flexible substrates plays a key role in the emerging flexible electronics technology. The flexible electronic devices are inexpensive and can be conformed to any shape. The potential applications for such devices are sensors, displays, solar cells, RFID, high-density biochips, optoelectronics etc. E-beam lithography is established as a powerful tool for nanoscale fabrication, but its applicability on insulating flexible substrates is often limited because of surface charging effects. This paper presents the fabrication of nanostructures on insulating flexible substrates using low energy E-beam lithography along with metallic layers for charge dissipation. Nano Structures are patterned on different substrates of materials such as acetate and PET foils. The fabrication process parameters such as the proximity gap of exposure, the exposure dosage and developing conditions have been optimized for each substrate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electronic systems are a very good platform for sensing biological signals for fast point-of-care diagnostics or threat detection. One of the solutions is the lab-on-a-chip integrated circuit (IC), which is low cost and high reliability, offering the possibility for label-free detection. In recent years, similar integrated biosensors based on the conventional complementary metal oxide semiconductor (CMOS) technology have been reported. However, post-fabrication processes are essential for all classes of CMOS biochips, requiring biocompatible electrode deposition and circuit encapsulation. In this work, we present an amorphous silicon (a-Si) thin film transistor (TFT) array based sensing approach, which greatly simplifies the fabrication procedures and even decreases the cost of the biosensor. The device contains several identical sensor pixels with amplifiers to boost the sensitivity. Ring oscillator and logic circuits are also integrated to achieve different measurement methodologies, including electro-analytical methods such as amperometric and cyclic voltammetric modes. The system also supports different operational modes. For example, depending on the required detection arrangement, a sample droplet could be placed on the sensing pads or the device could be immersed into the sample solution for real time in-situ measurement. The entire system is designed and fabricated using a low temperature TFT process that is compatible to plastic substrates. No additional processing is required prior to biological measurement. A Cr/Au double layer is used for the biological-electronic interface. The success of the TFT-based system used in this work will open new avenues for flexible label-free or low-cost disposable biosensors. © 2013 Materials Research Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article examines some preliminary tests which were performed in order to evaluate the best electrode configuration (width and spacing) for cell culture analyses. Biochips packaged with indium tin oxide (ITO) interdigitated electrodes (IDEs) were used to perform impedance measurements on A549 cells cultured on the surface of the biochip. Several tests were carried out using a 10 mM solution of Sodium Chloride (NaCl), cell medium and the cell culture itself to characterize some of the configurations already fabricated in the facilities at Tyndall National Institute.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a report on the 7th Annual Congress of International Drug Discovery Science and Technology held in Shanghai, China from 22–25 October, 2009. The conference, organized by BIT Life Sciences, comprised several parallel sessions, keynote presentations and a selection of selection of 20-minute presentations covering a range of therapeutic areas, including general medicinal chemistry, oncology, inflammation, receptors and ion channels, drug, metabolism and pharmokinetics, and fragment-based drug discovery. There were also sessions devoted to genomics, biomarkers, immunology, cell biology, molecular imaging and biochips. Supported by an exhibition of services/products and posters, the conference underlined the marked presence of Asian CROs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an increasing demand to develop biosensor monitoring devices capable of biomarker profiling for predicting animal adulteration and detecting multiple chemical contaminants or toxins in food produce. Surface plasmon resonance (SPR) biosensors are label free detection systems that monitor the binding of specific biomolecular recognition elements with binding partners. Essential to this technology are the production of biochips where a selected binding partner, antibody, biomarker protein or low molecular weight contaminant, is immobilised. A micro-fluidic immobilisation device allowing the covalent attachment of up to 16 binding partners in a linear array on a single surface has been developed for compatibility with a prototype multiplex SPR analyser.

The immobilisation unit and multiplex SPR analyser were respectively evaluated in their ability to be fit-for-purpose for binding partner attachment and detection of high and low molecular weight molecules. The multiplexing capability of the dual technology was assessed using phycotoxin concentration analysis as a model system. The parent compounds of four toxin groups were immobilised within a single chip format and calibration curves were achieved. The chip design and SPR technology allowed the compartmentalisation of the binding interactions for each toxin group offering the added benefit of being able to distinguish between toxin families and perform concentration analysis. This model is particularly contemporary with the current drive to replace biological methods for phycotoxin screening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Chapter 1 I will present a brief introduction on the state of art of nanotechnologies, nanofabrication techniques and unconventional lithography as a technique to fabricate the novel electronic device as resistive switch so-called memristor is shown. In Chapter 2 a detailed description of the main fabrication and characterization techniques employed in this work is reported. Chapter 3 parallel local oxidation lithography (pLOx) describes as a main technique to obtain accurate patterning process. All the effective parameters has been studied and the optimized condition observed to highly reproducible with excellent patterned nanostructures. The effect of negative bias, calls local reduction (LR) studied. Moreover, the use of AC bias shows faster patterning process respect to DC bias. In Chapter 4 (metal/ e-SiO2/ Si nanojunction) it is shown how the electrochemical oxide nanostructures by using pLOx can be used in the fabrication of novel devices call memristor. We demonstrate a new concept, based on conventional materials, where the lifetime problem is resolved by introducing a “regeneration” step, which restores the nano-memristor to its pristine condition by applying an appropriate voltage cycle. In Chapter 5 (Graphene/ e-SiO2/ Si), Graphene as a building block material is used as an electrode to selectively oxidize the silicon substrate by pLOx set up for the fabrication of novel resistive switch device. In Chapter 6 (surface architecture) I will show another application of pLOx in biotechnology is shown. So the surface functionalization combine with nano-patterning by pLOx used to design a new surface to accurately bind biomolecules with the possibility of studying those properties and more application in nano-bio device fabrication. So, in order to obtain biochips, electronic and optical/photonics devices Nano patterning of DNA used as scaffolds to fabricate small functional nano-components.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Entstehung der Atherosklerose ist ein komplexer Vorgang, der sich durch Ablagerung von Lipiden an der Gefäßwand sowie durch immunologische und inflammatorische Prozesse auszeichnet. Neben konventionellen Risikofaktoren wie Alter, Geschlecht, Rauchen, HDL-Cholesterin, Diabetes mellitus und einer positiven Familienanamnese werden zur Bestimmung des atherosklerotischen Risikos neue Biomarker der inflammatorischen Reaktion untersucht. Ziel dieser Arbeit war die Entwicklung einer Methode zur Diagnostik des Atheroskleroserisikos. Es wurde eine neuartige Chip-Technologie eingesetzt, um das Risiko für eine potentiell drohende atherosklerotische Erkrankung abzuschätzen. Dabei wurde ausgenutzt, dass molekulare Veränderungen in Genen bestimmte Krankheitsbilder auslösen können. rnEs wurde ein molekularbiologischer Test entwickelt, welcher die Untersuchung von genetischen Variationen aus genomischer DNA ermöglicht. Dafür fand die Entwicklung einer Multiplex-PCR statt, deren Produkt mit der Chip-Technologie untersucht werden kann. Dazu wurden auf einem Mikroarray Sonden immobilisiert, mit deren Hilfe genspezifische Mutationen nachgewiesen werden können. So wurden mehrere Gene mit einem geringen Aufwand gleichzeitig getestet. rnDie Auswahl der entsprechenden Marker erfolgte anhand einer Literaturrecherche von randomisierten und kontrollierten klinischen Studien. Der Mikroarray konnte für zwölf Variationen in den acht Genen Prostaglandinsynthase-1 (PTGS1), Endotheliale NO-Synthase (eNOS), Faktor V (F5), 5,10-Methylentetrahydrofolsäure-Reduktase (MTHFR), Cholesterinester-Transferprotein (CETP), Apolipoprotein E (ApoE), Prothrombin (F2) und Lipoproteinlipase (LPL) erfolgreich etabliert werden. Die Präzision des Biochips wurde anhand der Echtzeit-PCR und der Sequenzierung nachgewiesen. rnDer innovative Mikroarray ermöglicht eine einfache, schnelle und kosteneffektive Genotypisierung von wichtigen Allelen. Viele klinisch relevante Variationen für Atherosklerose können nun in nur einem Test überprüft werden. Zukünftige Studien müssen zeigen, ob die Methode eine Vorhersage über den Ausbruch der Erkrankung und eine gezielte Therapie ermöglicht. Dies wäre ein erster Schritt in Richtung präventive und personalisierter Medizin für Atherosklerose.rn