618 resultados para Balloon
Resumo:
261
Resumo:
The treatment of subglottic stenosis in children remains a challenge for the otorhinolaryngologist, and may involve both endoscopic and open surgery. To report the experience of two tertiary facilities in the treatment of acquired subglottic stenosis in children with balloon laryngoplasty, and to identify predictive factors for success of the technique and its complications. Descriptive, prospective study of children diagnosed with acquired subglottic stenosis and submitted to balloon laryngoplasty as primary treatment. Balloon laryngoplasty was performed in 37 children with an average age of 22.5 months; 24 presented chronic subglottic stenosis and 13 acute subglottic stenosis. Success rates were 100% for acute subglottic stenosis and 32% for chronic subglottic stenosis. Success was significantly associated with acute stenosis, initial grade of stenosis, children of a smaller age, and the absence of tracheostomy. Transitory dysphagia was the only complication observed in three children. Balloon laryngoplasty may be considered the first line of treatment for acquired subglottic stenosis. In acute cases, the success rate is 100%, and although the results are less promising in chronic cases, complications are not significant and the possibility of open surgery remains without prejudice.
Resumo:
The treatment of subglottic stenosis in children remains a challenge for the otolaryngologist and may involve procedures such as endoscopy, open surgery, and often both. In the recent past, high-pressure balloons have been used in endoscopic treatment due to their relative facility and high success rates. To report success rates in the treatment of acquired subglottic stenosis with balloon laryngoplasty in children and identify predictive factors for the success of the technique and its complications. Descriptive, prospective study of children who were diagnosed with acquired subglottic stenosis and underwent balloon laryngoplasty as the primary treatment. Balloon laryngoplasty was performed in 48 children with an average age of 20.7 months: 31 presented with chronic subglottic stenosis and 17 with acute stenosis. Success rate was 100% for acute and 39% for chronic subglottic stenosis. Success was significantly associated with several factors, including recently acquired stenosis, initial grade of stenosis, younger patient age, and the absence of tracheotomy. Complications were transitory dysphagia observed in three children and a submucosal cyst in one of the patients. Balloon laryngoplasty may be considered as a first line of treatment for acquired subglottic stenosis. In acute cases, the success rate was 100%, and even though results are less promising in chronic cases, complications were not significant and the patients can undergo open surgery without contraindications. Predictive factors of success were acute stenosis, less severe grades of stenosis, younger patient age, and the absence of tracheotomy.
Resumo:
BACKGROUND AND PURPOSE The consequences of compensatory responses to balloon catheter injury in rat carotid artery, on phenylephrine-induced relaxation and contraction in the contralateral carotid artery were studied. EXPERIMENTAL APPROACH Relaxation and contraction concentration-response curves for phenylephrine were obtained for contralateral carotid arteries in the presence of indomethacin (COX inhibitor), SC560 (COX-1 inhibitor), SC236 (COX-2 inhibitor) or 4-hydroxytetramethyl-L-piperidine-1-oxyl (tempol; superoxide dismutase mimetic). Reactive oxygen species were measured in carotid artery endothelial cells fluorimetrically with dihydroethidium. KEY RESULTS Phenylephrine-induced relaxation was abolished in contralateral carotid arteries from operated rats (E(max) = 0.01 +/- 0.004 g) in relation to control (E(max) = 0.18 +/- 0.005 g). Phenylephrine-induced contractions were increased in contralateral arteries (E(max) = 0.54 +/- 0.009 g) in relation to control (E(max) = 0.38 +/- 0.014 g). SC236 restored phenylephrine-induced relaxation (E(max) = 0.17 +/- 0.004 g) and contraction (E(max) = 0.34 +/- 0.018 g) in contralateral arteries. Tempol restored phenylephrine-induced relaxation (E(max) = 0.19 +/- 0.012 g) and contraction (E(max) = 0.42 +/- 0.014 g) in contralateral arteries, while apocynin did not alter either relaxation (E(max) = 0.01 +/- 0.004 g) or contraction (E(max) = 0.54 +/- 0.009 g). Dihydroethidium fluorescence was increased in contralateral samples (18 882 +/- 435 U) in relation to control (10 455 +/- 303 U). SC236 reduced the fluorescence in contralateral samples (8250 +/- 365 U). CONCLUSIONS AND IMPLICATIONS Balloon catheter injury abolished phenylephrine-induced relaxation and increased phenylephrine-induced contraction in contralateral carotid arteries, through O(2)(-) derived from COX-2.
Resumo:
Balloon catheter injury results in hyper-reactivity to phenylephrine in contralateral carotids. Decreased nitric oxide (NO) modulation and/or increased intracellular calcium concentration triggers vascular smooth muscle contraction. Therefore, this study explores the participation of NO signaling pathway and calcium mobilization on hyper-reactivity to phenylephrine in contralateral carotids. Concentration-response curves for calcium (CaCl(2)) and phenylephrine were obtained in control and contralateral carotids four days after balloon injury, in the presence and absence of the inhibitors (L-NAME, L-NNA, 1400W, 7-NI, Oxyhemoglobin, ODQ or Tiron). Confocal microscopy using Fluo-3AM or DHE was performed to detect the intracellular levels of calcium and reactive oxygen species, respectively. The modulation of NO on phenylephrine-induced contraction was absent in the contralateral carotid. Phenylephrine-induced intracellular calcium mobilization was not altered in contralateral carotids. However, extracellular calcium mobilization by phenylephrine was reduced in the contralateral carotid compared to control arteries, and this result was confirmed by confocal microscopy. L-NAME increased phenylephrine-induced extracellular calcium mobilization in the contralateral carotid to the control levels. Results obtained with L-NNA, 1400W, 7-NI, OxyHb, ODQ or Tiron showed that this response was mediated by products from endothelial NOS (eNOS) different from NO and without soluble guanylate cyclase activation, but it involved superoxide anions. Furthermore. Tiron or L-NNA reduced the levels of reactive oxygen species in contralateral carotids. Data suggest that balloon catheter injury promoted eNOS uncoupling in contralateral carotids, which generates superoxide rather than NO, and reduces phenylephrine-induced extracellular calcium mobilization, despite the hyper-reactivity to phenylephrine in contralateral carotids. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Balloon catheter injury promotes hyperreactivity to phenylephrine (Phe) in the contralateral carotid. Phe-induced contraction involves calcium mobilization, a process that may be sensitive to reactive oxygen species. In this study, we investigated whether increased reactivity to Phe in the contralateral carotid is due to alterations in calcium mobilization by Phe and reactive oxygen species signaling. Concentration-response curves to Phe were obtained in control and contralateral arteries 4 days after balloon injury. Tiron did not modify E(max) to Phe in control arteries but reduced this parameter in the contralateral carotid to control levels. Moreover, immunofluorescence to dihydroethydine showed increased basal oxidative stress in the contralateral artery compared with control artery. Intracellular calcium mobilization by Phe in the contralateral artery was not different from control, but Phe-induced extracellular calcium mobilization was reduced in the contralateral artery compared with that in the control. These data were confirmed by confocal microscopy using Fluo 3-AM. Tiron and SC-236 increased Phe-induced calcium influx in the contralateral artery, which was similar to controls in the same conditions. However, catalase did not modify this response. Taken together, our results suggest that superoxide anions and prostanoids from cyclooxygenase-2 alter pathways downstream of alpha(1)-adrenoceptor activation in the contralateral carotid in response to injury. This results in reduced Phe-induced calcium influx, despite hyperreactivity to Phe.
Resumo:
Percutaneous transluminal coronary angioplasty is a frequently used interventional technique to reopen arteries that have narrowed because of atherosclerosis. Restenosis, or renarrowing of the artery shortly after angioplasty, is a major limitation to the success of the procedure and is due mainly to smooth muscle cell accumulation in the artery wall at the site of balloon injury. In the present study, we demonstrate that the antiangiogenic sulfated oligosaccharide, PI-88, inhibits primary vascular smooth muscle cell proliferation and reduces intimal thickening 14 days after balloon angioplasty of rat and rabbit arteries. PI-88 reduced heparan sulfate content in the injured artery wall and prevented change in smooth muscle phenotype. However, the mechanism of PI-88 inhibition was not merely confined to the antiheparanase activity of this compound. PI-88 blocked extracellular signal-regulated kinase-1/2 (ERK1/2) activity within minutes of smooth muscle cell injury. It facilitated FGF-2 release from uninjured smooth muscle cells in vitro, and super-released FGF-2 after injury while inhibiting ERK1/2 activation. PI-88 inhibited the decrease in levels of FGF-2 protein in the rat artery wall within 8 minutes of injury. PI-88 also blocked injury-inducible ERK phosphorylation, without altering the clotting time in these animals. Optical biosensor studies revealed that PI-88 potently inhibited (K-i 10.3 nmol/L) the interaction of FGF-2 with heparan sulfate. These findings show for the first time the capacity of this sulfated oligosaccharide to directly bind FGF-2, block cellular signaling and proliferation in vitro, and inhibit injury-induced smooth muscle cell hyperplasia in two animal models. As such, this study demonstrates a new role for PI-88 as an inhibitor of intimal thickening after balloon angioplasty. The full text of this article is available online at http://www.circresaha.org.
Resumo:
Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.
Resumo:
Purpose: Most groups have reported disappointing results with autoaugmentation or detrusor myectomy for low capacity/compliance neuropathic bladders. Failure may be due to an ischemic diverticulum or mucosal shrinkage. We investigated whether a Silimed (R) silicone balloon placed in the bladder after autoaugmentation could prevent these problems, improving surgical results. Materials and Methods: We compared the results of standard bladder autoaugmentation in 12 children (group 1) with those in 10 (group 2) who underwent the same surgery using a bladder conformer. The conformer was a silicone balloon filled with saline that remained in the bladder for 2 weeks. All patients had a neuropathic bladder with poor capacity and compliance, resulting in urinary leakage between catheterizations. Preoperative and postoperative evaluation included a voiding diary, ultrasound, voiding cystourethrogram and urodynamics. Results: In group 1 only 1 patient became dry, 4 had little improvement in continence, 4 remained unchanged and 3 became worse. In group 2, 6 patients (60%) become continent without medication, 2 (20%) become continent with oxybutynin and 2 remained unchanged. Bladder capacity and compliance did not change significantly in group 1. However, in group 2 capacity changed from a mean of 140 to 240 ml and mean +/- SD compliance increased from 15.6 +/- 16.8 to 34.3 +/- 22.8 ml/cm H(2)O (p = 0.02). Conclusions: The inflatable balloon improved our long-term results of bladder auto-augmentation. A larger series may be necessary to confirm procedure efficacy and safety.
Resumo:
Background: Silastic rings are used in gastric bypass procedures for the treatment of obesity, but ring slippage may lead to gastric pouch outlet stenosis (GPOS). Conventional management has been ring removal through abdominal surgery. Objective: To describe a novel, safe, minimally invasive, endoscopic technique for the treatment of GPOS caused by ring slippage after gastric bypass. Design: Case series. Setting: Federal University of Pernambuco and sao Paulo University. Patients: This study involved 39 consecutive patients who-were screened for inclusion. Intervention: Endoscopic dilation with an achalasia balloon. Main Outcome Measurements: Technical success and safety of the procedure. Results: Among the 39 patients, 35 underwent endoscopic dilation at the ring slippage site for the relief of GPOS. The 4 patients who did not undergo endoscopic dilation underwent surgical removal of the ring, based on the exclusion criteria. The endoscopic approach was successful in 1 to 4 sessions in 100% of cases with radioscopic control (n = 12). The duration of the procedures ranged from 5 to 30 minutes, and the average internment was 14.4 hours. Dilation promoted either rupture (65.7%) or stretching (34.3%) of the thread within the ring, thereby increasing the luminal diameter of the GPOS. Complications included self-limited upper digestive tract hemorrhage (n = 1) and asymptomatic ring erosion (n = 4). There were no recurrences of obstructive symptoms during the follow-up period (mean of 33.3 months). Limitations: This was not a randomized, comparison study, and the number of patients was relatively small. Conclusion: The technique described promotes the relief of GPOS with low overall morbidity and avoids abdominal reoperation for ring removal. (Gastrointest Endosc 2010;72:44-9.)
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Background: Double-balloon enteroscopy (DBE) allows evaluation and therapy for various small bowel diseases. In this series the outcome of a 4-year experience in a tertiary hospital school in Brazil is reported. Methods: A total of 457 consecutive DBE were performed in 418 patients from August 2004 to August 2008. 93 patients with several indications, whose aim was not the evaluation of suspected diseases of the small bowel mucosa, were excluded, therefore leaving 364 DBE in 325 patients for analysis. Data were retrospectively collected with regard to clinical, endoscopic findings, therapy and complications. Results: Among the 364 DBE performed in 325 patients, 143/325 were males (44%) and 182/325 females (56%) with a mean age of 48.6 +/- 15.7 years (range 17-89). Mean investigation time was 64 +/- 22 min (range 35-135). The depth of insertion beyond the ligament of Treitz was 230 +/- 85 cm (range 30-500) by the antegrade approach and 140 +/- 75 cm (range 0-320) by the retrograde approach. Total enteroscopy was achieved in 41.66% of the attempts (30 of 72 patients). Overall diagnostic yield was 54.95% (200 of 364 procedures) ranging from 0 to 100% in this series, depending on the indication. Angiodysplasia was the main diagnosis in 24.5% (49 of 200 procedures) and endoscopic treatment, including biopsies, hemostasis, tattooing and polypectomy were performed in 65.38% (238 of 364 procedures). No major complications were reported. Conclusions: DBE is a feasible, safe and well-tolerated procedure allowing endoscopic therapy. Selection of indications increases its diagnostic yield. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Double-balloon enteroscopy (DBE) is a useful method for endoscopic retrograde cholangiopancreatography (ERCP) in patients with Roux-en-Y anatomy. Depending on the distorted anatomy, endoscopic therapies with conventional scopes were very difficult or impossible before the advent of DBE and patients had to be submitted to a percutaneous or surgical approach. The case of 6 patients with different types of Roux-en-Y-altered anatomy in which DBE-ERCP was performed with 83.3% successful rate (5/6) is reported confirming recent data in the literature on the feasibility of this method. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Sporadic lymphangiectasias are commonly found throughout the small bowel and are considered to be normal. Not uncommonly, lymphangiectasias are pathologic and can lead to mid-gastrointestinal bleeding, abdominal pain and protein-losing enteropathy. Pathologic lymphangiectasias of the small bowel include primary lymphangiectasia, secondary lymphangiectasia and lymphaticovenous malformations. In this report we present three different cases of small bowel lymphangiectasia detected by double balloon enteroscopy. The patients were diagnosed with South American blastomycosis, tuberculosis and primary small bowel lymphangioma. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Intervenção cardiovascular