848 resultados para BEAM PROFILES


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We investigate the design of free-space optical interconnects (FSOIs) based on arrays of vertical-cavity surface-emitting lasers (VCSELs), microlenses, and photodetectors. We explain the effect of the modal structure of a multimodeVCSEL beam on the performance of a FSOI with microchannel architecture. A Gaussian-beam diffraction model is used in combination with the experimentally obtained spectrally resolved VCSEL beam profiles to determine the optical channel crosstalk and the signal-to-noise ratio (SNR) in the system. The dependence of the SNR on the feature parameters of a FSOI is investigated. We found that the presence of higher-order modes reduces the SNR and the maximum feasible interconnect distance. We also found that the positioning of a VCSEL array relative to the transmitter microlens has a significant impact on the SNR and the maximum feasible interconnect distance. Our analysis shows that the departure from the traditional confocal system yields several advantages including the extended interconnect distance and/or improved SNR. The results show that FSOIs based on multimode VCSELs can be efficiently utilized in both chip-level and board-level interconnects. (C) 2002 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Robottiikkatuoteperheeseen kuuluu robottihitsausportaalit, joiden päärunko rakentuu kote-lopalkeista. Koteloprofiilien käyttö on suosittua teollisuuden eri aloilla ja se soveltuu hyvin raskaaseen konepajateollisuuteen. Hitsausrobottiportaalin suunnitteluun liittyy monia eri vaiheita ja valituilla teknisillä ratkaisuilla voidaan vaikuttaa valmistettavan tuotteen hitsin laatuun ja työn onnistumiseen. Hitsausrobottiportaalit ovat usein asiakasräätälöityjä ratkaisuja, jolloin suunnittelutyö sekä valmistusvaihe vaativat runsaasti kapasiteettia. Modulaarisuuden avulla suunnittelu- ja valmistusvaiheita on mahdollista nopeuttaa sekä parantaa tuotteen testausta, huollettavuutta ja laatua. Tässä diplomityössä tutkittiin, miten hitsausrobottiportaalin vaakapuomi käyttäytyy ja taipuu erilaisissa kuormitustilanteissa. Lisäksi työssä määritettiin alkuperäisen koteloprofiilin tilalle uusi optimoitu koteloprofiili sekä tarkasteltiin moduloinnin mahdollistamista robo-tiikkatuoteperheen portaalisovelluksiin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A generalized systematic description of the Two-Wave Mixing (TWM) process in sillenite crystals allowing for arbitrary orientation of the grating vector is presented. An analytical expression for the TWM gain is obtained for the special case of plane waves in a thin crystal (|g|d«1) with large optical activity (|g|/?«1, g is the coupling constant, ? the rotatory power, d the crystal thickness). Using a two-dimensional formulation the scope of the nonlinear equations describing TWM can be extended to finite beams in arbitrary geometries and to any crystal parameters. Two promising applications of this formulation are proposed. The polarization dependence of the TWM gain is used for the flattening of Gaussian beam profiles without expanding them. The dependence of the TWM gain on the interaction length is used for the determination of the crystal orientation. Experiments carried out on Bi12GeO20 crystals of a non-standard cut are in good agreement with the results of modelling.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A generalized systematic description of the Two-Wave Mixing (TWM) process in sillenite crystals allowing for arbitrary orientation of the grating vector is presented. An analytical expression for the TWM gain is obtained for the special case of plane waves in a thin crystal (|g|d«1) with large optical activity (|g|/?«1, g is the coupling constant, ? the rotatory power, d the crystal thickness). Using a two-dimensional formulation the scope of the nonlinear equations describing TWM can be extended to finite beams in arbitrary geometries and to any crystal parameters. Two promising applications of this formulation are proposed. The polarization dependence of the TWM gain is used for the flattening of Gaussian beam profiles without expanding them. The dependence of the TWM gain on the interaction length is used for the determination of the crystal orientation. Experiments carried out on Bi12GeO20 crystals of a non-standard cut are in good agreement with the results of modelling.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Se describe un procedimiento para la consolidación de viguetas de forjado de madera con deterioro en las cabezas mediante perfiles de acero conectados a la madera desde la cara superior del forjado. La pieza de refuerzo es un perfil en U de acero S275 conformado en frío con pletinas soldadas insertadas en la madera y conectada mediante tirafondos. Se ensayaron 30 piezas a flexión obteniendo la rigidez y la capacidad de carga. Las probetas se dividieron en tres grupos. El primero compuesto por 10 piezas de madera laminada encolada de abeto con una sección de 180 x 200 mm y una longitud de 4.000 mm; el segundo consistía en 10 piezas de madera aserrada de pino silvestre con la misma sección y longitud y, el tercero, estaba formado por otras 10 piezas de madera del género Pinus con una sección de 130 x 150 mm y 3.000 mm de longitud, procedentes de un edificio de Madrid con 120 años de antigüedad. Cada grupo de 10 piezas se dividió a su vez en dos grupos de 5 piezas. El primer subgrupo estaba formado por las piezas completas de madera y constituía el grupo de referencia. Las piezas del segundo subgrupo tenían una longitud inferior que se salvaba con una extensión del refuerzo metálico. Los resultados indican que el sistema de refuerzo metálico permite resolver los problemas de falta de apoyo de la vigueta por deterioro de la madera que afecte en una longitud limitada (aproximadamente entre el 10 y el 20% de la longitud).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to assess the efficacy of rosemary and oregano extracts in avoiding oxidative changes in beef burgers, and to evaluate the fatty acid profile of these products after electron beam exposition. Extracts, individually or in combination, were added to beef burgers and compared to synthetic antioxidants commonly used in food (butylated hydroxytoluene, butylated hydroxyanisole). The ground beef were submitted to electron beam irradiation at doses of 0, 3.5 and 7 kGy, and stored for 90 days. At regular time intervals, lipid oxidation and fatty acid composition were evaluated through measurement of thiobarbituric acid-reactive substances (TBARS) and gas chromatography, respectively. The results indicate that, although the irradiation process triggers an increase in the lipid oxidation ratio expressed by TBARS values, great changes in the fatty acid profiles were not observed; instead, they continued to present characteristics very similar to that of non-irradiated beef. Thus, as irradiation doses of up to 7 kGy for frozen meat can make foods safe from foodborne pathogens, natural antioxidants derived from spices are able to reduce and avoid lipid changes that may cause a deterioration of the sensory quality of these foods, and these natural extracts offer a good choice for replacing synthetic additives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Functionally graded composite materials can provide continuously varying properties, which distribution can vary according to a specific location within the composite. More frequently, functionally graded materials consider a through thickness variation law, which can be more or less smoother, possessing however an important characteristic which is the continuous properties variation profiles, which eliminate the abrupt stresses discontinuities found on laminated composites. This study aims to analyze the transient dynamic behavior of sandwich structures, having a metallic core and functionally graded outer layers. To this purpose, the properties of the particulate composite metal-ceramic outer layers, are estimated using Mod-Tanaka scheme and the dynamic analyses considers first order and higher order shear deformation theories implemented though kriging finite element method. The transient dynamic response of these structures is carried out through Bossak-Newmark method. The illustrative cases presented in this work, consider the influence of the shape functions interpolation domain, the properties through-thickness distribution, the influence of considering different materials, aspect ratios and boundary conditions. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present effective-mass calculations of the bound-state energy levels of electrons confined inside lens-shaped InxGa1-xAs quantum dots (QDs) embedded in a GaAs matrix, taking into account the strain as well as the In gradient inside the QDs due to the strong In segregation and In-Ga intermixing present in the InxGa1-xAs/GaAs system. In order to perform the calculations, we used a continuum model for the strain, and the QDs and wetting layer were divided into their constituting monolayers, each one with a different In concentration, to be able to produce a specific composition profile. Our results clearly show that the introduction of such effects is very important if one desires to correctly reproduce or predict the optoelectronic properties of these nanostructures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GFRP pultruded profiles have shown to be structural profiles with great stiffness, strenght and very low specific weight, making it a great candidate for the rehabilitation of damaged strucutres. To further enhance the strucutral mechanism of these type of beams, the Slimflor composite structural system has lead as basis for this analysis; by replacing the steel beam with a GFRP pultruded profile. To further increase its composite action, a continuous shear connector has been set as part of the beam cross section as well as its needed reinforcement and fire protection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monte Carlo (MC) based dose calculations can compute dose distributions with an accuracy surpassing that of conventional algorithms used in radiotherapy, especially in regions of tissue inhomogeneities and surface discontinuities. The Swiss Monte Carlo Plan (SMCP) is a GUI-based framework for photon MC treatment planning (MCTP) interfaced to the Eclipse treatment planning system (TPS). As for any dose calculation algorithm, also the MCTP needs to be commissioned and validated before using the algorithm for clinical cases. Aim of this study is the investigation of a 6 MV beam for clinical situations within the framework of the SMCP. In this respect, all parts i.e. open fields and all the clinically available beam modifiers have to be configured so that the calculated dose distributions match the corresponding measurements. Dose distributions for the 6 MV beam were simulated in a water phantom using a phase space source above the beam modifiers. The VMC++ code was used for the radiation transport through the beam modifiers (jaws, wedges, block and multileaf collimator (MLC)) as well as for the calculation of the dose distributions within the phantom. The voxel size of the dose distributions was 2mm in all directions. The statistical uncertainty of the calculated dose distributions was below 0.4%. Simulated depth dose curves and dose profiles in terms of [Gy/MU] for static and dynamic fields were compared with the corresponding measurements using dose difference and γ analysis. For the dose difference criterion of ±1% of D(max) and the distance to agreement criterion of ±1 mm, the γ analysis showed an excellent agreement between measurements and simulations for all static open and MLC fields. The tuning of the density and the thickness for all hard wedges lead to an agreement with the corresponding measurements within 1% or 1mm. Similar results have been achieved for the block. For the validation of the tuned hard wedges, a very good agreement between calculated and measured dose distributions was achieved using a 1%/1mm criteria for the γ analysis. The calculated dose distributions of the enhanced dynamic wedges (10°, 15°, 20°, 25°, 30°, 45° and 60°) met the criteria of 1%/1mm when compared with the measurements for all situations considered. For the IMRT fields all compared measured dose values agreed with the calculated dose values within a 2% dose difference or within 1 mm distance. The SMCP has been successfully validated for a static and dynamic 6 MV photon beam, thus resulting in accurate dose calculations suitable for applications in clinical cases.