956 resultados para Air Conditioning System


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most modern passenger aeroplanes use air cycle cooling. A high-speed air cycle is a reliable and light option, but not very efficient. This thesis presents research work done to design a novel vapour cooling cycle for aeroplanes. Due to advancements in high-speed permanent magnet motors, the vapour cycle is seen as a competitive option for the air cycle in aeroplanes. The aerospace industry places tighter demands on the weight, reliability and environmental effects of the machinery than those met by conventional chillers, and thus modifications to conventional design are needed. The thesis is divided into four parts: the initial screening of the working fluid, 1-D design and performance values of the compressor, 1-D off-design value predictions of the compressor and the 3-D design of the compressor. The R245fa was selected as the working fluid based the study. The off-design range of the compressor was predicted to be wide and suitable for the application. The air-conditioning system developed is considerably smaller than previous designs using centrifugal compressors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IPLV overall coefficient, presented by Air-Conditioning and Refrigeration Institute (ARI) of America, shows running/operation status of air-conditioning system host only. For overall operation coefficient, logical solution has not been developed, to reflect the whole air-conditioning system under part load. In this research undertaking, the running time proportions of air-conditioning systems under part load have been obtained through analysis on energy consumption data during practical operation in all public buildings in Chongqing. This was achieved by using analysis methods, based on the statistical energy consumption data distribution of public buildings month-by-month. Comparing with the weight number of IPLV, part load operation coefficient of air-conditioning system, based on this research, does not only show the status of system refrigerating host, but also reflects and calculate energy efficiency of the whole air-conditioning system. The coefficient results from the processing and analyzing of practical running data, shows the practical running status of area and building type (actual and objective) – not clear. The method is different from model analysis which gets IPLV weight number, in the sense that this method of coefficient results in both four equal proportions and also part load operation coefficient of air-conditioning system under any load rate as necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive feature of the system is its full utilization of cooling capacity and freshness of outdoor air in the transition period of the year round. On the basis of the obtain of the dynamic cooling loads of the typical shopping malls in different four cities located in cold climates in China with the aid of DOE-2, the possibility of increasing the amount of outdoor air volume of CVAV system in the transition period instead of operating the water chillers was confirmed. Moreover, a new concept, Direct Outdoor Air Cooling Efficiency (DOACE), was defined as the ratio of cooling capacity of outdoor air to the water chiller, indicating the degree of outdoor air’s utilization. And the DOACE of the CVAV was calculated and compared with that of conventional all-air constant volume air-conditioning systems, the results showed that CVAV bear much more energy saving potential with the 10%~19% higher DOACE and it is a kind of energy efficient systems and can improve the indoor air quality as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a thermoeconomic analysis method based on the first and second law of thermodynamics and applied to an evaporative cooling system coupled to an adsorption dehumidifier, is presented. The main objective is the use of a method called exergetic manufacturing cost (EMC) applied to a system that operates in three different conditions to minimize the operation costs. Basic parameters are the RIP ratio (reactivation air/process air) and the reactivation air temperature. Results of this work show that the minimum reactivation temperature and the minimum RIP ratio corresponds to the smaller EMC. This result can be corroborated through an energetic analysis. It is noted that this case is also the one corresponding to smaller energy loss. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The factors that have influence on the energy consumption of a small air conditioning system that are worth mentioning are the efficiencies of the compressor, evaporator and condenser, the form that the refrigerant flow is controlled, the fan model used, and climatic conditions. Within the climate issue, an interesting factor is that the relative humidity when it comes to the effect that it causes, especially in the performance of the air condenser, which generally is not considered in the projects. This study aims to evaluate the influence of humidity on the coefficient of system performance (COP), seeking to quantify their influence when it happens. The tests were performed on a testing bench, mounted at the Laboratory for Energy Efficiency (LAMOTRIZ) UNESP-Campus Guaratinguetá. In the study, the wet bulb temperature was ranged, keeping the rotation of the scroll compressor with application of a frequency inverter in its best performance. The test bench is provided with a supervisory system of data collection that is also able to control all functions of the bench. In the results, there was a significant influence, particularly when comparing high humidity conditions with low humidity, noting that only over 65% relative humidity is that significant changes are observed in the COP of the system. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose – To evaluate the control strategy for a hybrid natural ventilation wind catchers and air-conditioning system and to assess the contribution of wind catchers to indoor air environments and energy savings if any. Design/methodology/approach – Most of the modeling techniques for assessing wind catchers performance are theoretical. Post-occupancy evaluation studies of buildings will provide an insight into the operation of these building components and help to inform facilities managers. A case study for POE was presented in this paper. Findings – The monitoring of the summer and winter month operations showed that the indoor air quality parameters were kept within the design target range. The design control strategy failed to record data regarding the operation, opening time and position of wind catchers system. Though the implemented control strategy was working effectively in monitoring the operation of mechanical ventilation systems, i.e. AHU, did not integrate the wind catchers with the mechanical ventilation system. Research limitations/implications – Owing to short-falls in the control strategy implemented in this project, it was found difficult to quantify and verify the contribution of the wind catchers to the internal conditions and, hence, energy savings. Practical implications – Controlling the operation of the wind catchers via the AHU will lead to isolation of the wind catchers in the event of malfunctioning of the AHU. Wind catchers will contribute to the ventilation of space, particularly in the summer months. Originality/value – This paper demonstrates the value of POE as indispensable tool for FM professionals. It further provides insight into the application of natural ventilation systems in building for healthier indoor environments at lower energy cost. The design of the control strategy for natural ventilation and air-conditioning should be considered at the design stage involving the FM personnel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Data centre is a centralized repository,either physical or virtual,for the storage,management and dissemination of data and information organized around a particular body and nerve centre of the present IT revolution.Data centre are expected to serve uniinterruptedly round the year enabling them to perform their functions,it consumes enormous energy in the present scenario.Tremendous growth in the demand from IT Industry made it customary to develop newer technologies for the better operation of data centre.Energy conservation activities in data centre mainly concentrate on the air conditioning system since it is the major mechanical sub-system which consumes considerable share of the total power consumption of the data centre.The data centre energy matrix is best represented by power utilization efficiency(PUE),which is defined as the ratio of the total facility power to the IT equipment power.Its value will be greater than one and a large value of PUE indicates that the sub-systems draw more power from the facility and the performance of the data will be poor from the stand point of energy conservation. PUE values of 1.4 to 1.6 are acievable by proper design and management techniques.Optimizing the air conditioning systems brings enormous opportunity in bringing down the PUE value.The air conditioning system can be optimized by two approaches namely,thermal management and air flow management.thermal management systems are now introduced by some companies but they are highly sophisticated and costly and do not catch much attention in the thumb rules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Greenhouses have become an invaluable source of year-round food production. Further development of viable and efficient high performance greenhouses is important for future food security. Closing the greenhouse envelope from the environment can provide benefits in space heating energy savings, pest control, and CO2 enrichment. This requires the application of a novel air conditioning system to handle the high cooling loads experienced by a greenhouse. Liquid desiccant air-conditioning (LDAC) have been found to provide high latent cooling capacities, which is perfect for the application of a humid greenhouse microclimate. TRNSYS simulations were undertaken to study the feasibility of two liquid desiccant dehumidification systems based on their capacity to control the greenhouse microclimate, and their cooling performance. The base model (B-LDAC) included a natural gas boiler, and two cooling systems for seasonal operation. The second model (HP-LDAC) was a hybrid liquid desiccant-heat pump dehumidification system. The average tCOPdehum and tCOPtotal of the B-LDAC system increased from 0.40 and 0.56 in January to 0.94 and 1.09 in June. Increased load and performance during a sample summer day improved these values to 3.5 and 3.0, respectively. The average eCOPdehum and eCOPtotal values were 1.0 and 1.8 in winter, and 1.7 and 2.1 in summer. The HP-LDAC system produced similar daily performance trends where the annual average eCOPdehum and eCOPtotal values were 1.3 and 1.2, but the sample day saw peaks of 2.4 and 3.2, respectively. The B-LDAC and HP-LDAC results predicted greenhouse temperatures exceeding 30°C for 34% and 17% of the month of July, respectively. Similarly, humidity levels increased in summer months, with a maximum of 14% of the time spent over 80% in May for both models. The percentage of annual savings in space heating energy associated with closing the greenhouse to ventilation was 34%. The additional annual regeneration energy input was reduced by 26% to 526 kWhm-2, with the implementation of a heat recovery ventilator on the regeneration exhaust air. The models also predicted an electrical energy input of 245 kWhm-2 and 305 kWhm-2 for the B-LDAC and HP-LDAC simulations, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy consumption and energy efficiency have become an issue. Energy consumption is rising all over the world and because of that, and the climate change, energy is becoming more and more expensive. Buildings are major consumers of energy, and inside the buildings the major consumers are heating, ventilation and air-conditioning systems. They usually run at constant speed without efficient control. In most cases HVAC equipment is also oversized. Traditionally heating, ventilation and air-conditioning systems have been sized to meet conditions that rarely occur. The theory part in this thesis represents the basics of life cycle costs and calculations for the whole life cycle of a system. It also represents HVAC systems, equipment, systems controls and ways to save energy in these systems. The empirical part of this thesis represents life cycle cost calculations for HVAC systems. With these calculations it is possible to compute costs for the whole life cycle for the wanted variables. Life cycle costs make it possible to compare which variable causes most of the costs from the whole life point of view. Life cycle costs were studied through two real life cases which were focused on two different kinds of HVAC systems. In both of these cases the renovations were already made, so that the comparison between the old and the new, now existing system would be easier. The study indicates that energy can be saved in HVAC systems by using variable speed drive as a control method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The demands in production and associate costs at power generation through non renewable resources are increasing at an alarming rate. Solar energy is one of the renewable resource that has the potential to minimize this increase. Utilization of solar energy have been concentrated mainly on heating application. The use of solar energy in cooling systems in building would benefit greatly achieving the goal of non-renewable energy minimization. The approaches of solar energy heating system research done by initiation such as University of Wisconsin at Madison and building heat flow model research conducted by Oklahoma State University can be used to develop and optimize solar cooling building system. The research uses two approaches to develop a Graphical User Interface (GUI) software for an integrated solar absorption cooling building model, which is capable of simulating and optimizing the absorption cooling system using solar energy as the main energy source to drive the cycle. The software was then put through a number of litmus test to verify its integrity. The litmus test was conducted on various building cooling system data sets of similar applications around the world. The output obtained from the software developed were identical with established experimental results from the data sets used. Software developed by other research are catered for advanced users. The software developed by this research is not only reliable in its code integrity but also through its integrated approach which is catered for new entry users. Hence, this dissertation aims to correctly model a complete building with the absorption cooling system in appropriate climate as a cost effective alternative to conventional vapor compression system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of computational fluid dynamics simulations for calibrating a flush air data system is described, In particular, the flush air data system of the HYFLEX hypersonic vehicle is used as a case study. The HYFLEX air data system consists of nine pressure ports located flush with the vehicle nose surface, connected to onboard pressure transducers, After appropriate processing, surface pressure measurements can he converted into useful air data parameters. The processing algorithm requires an accurate pressure model, which relates air data parameters to the measured pressures. In the past, such pressure models have been calibrated using combinations of flight data, ground-based experimental results, and numerical simulation. We perform a calibration of the HYFLEX flush air data system using computational fluid dynamics simulations exclusively, The simulations are used to build an empirical pressure model that accurately describes the HYFLEX nose pressure distribution ol cr a range of flight conditions. We believe that computational fluid dynamics provides a quick and inexpensive way to calibrate the air data system and is applicable to a broad range of flight conditions, When tested with HYFLEX flight data, the calibrated system is found to work well. It predicts vehicle angle of attack and angle of sideslip to accuracy levels that generally satisfy flight control requirements. Dynamic pressure is predicted to within the resolution of the onboard inertial measurement unit. We find that wind-tunnel experiments and flight data are not necessary to accurately calibrate the HYFLEX flush air data system for hypersonic flight.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Demand Response has been taking over the years an extreme importance. There’s a lot of demand response programs, one of them proposed in this paper, using air conditioners that could increase the power quality and decrease the spent money in many ways like: infrastructures and customers energy bill reduction. This paper proposes a method and a study on how air conditioners could integrate demand response programs. The proposed method has been modelled as an energy resources management optimization problem. This paper presents two case studies, the first one with all costumers participating and second one with some of costumers. The results obtained for both case studies have been analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays natural ventilation has gained prominence because its correct use can reduce energy consumption for cooling systems and improve thermal comfort among users. In this paper, we report on the modelling initiative, based on the wind tunnel tests that were carried out for the determination of the influence of natural ventilation in buildings. Indeed, the renewal of air in a closed environment without using an air conditioning system with mechanical elements can lead to energy savings and, in addition, provide air quality.The wind tunnel tests were carried out by varying the positioning of six ventilation modules in the façade system configuration. The modules were positioned below the window-sill (ventilated window-sill) as well as separately above and below the façade. The wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. The results supported the positioning of the six ventilation modules below the window-sill, forming a â ventilated window-sillâ as the most effective natural ventilation solution.