977 resultados para Agreement index
Resumo:
本研究应用数字地球技术,基于1950年~1980年的全国958个气象站的基本气象数据(包括气象站的经纬度,海拔,月均温,月降水,年均温, 年降水,日照时数,日照百分率,风速等),比较了四个不同的根据水、热平衡原理设计的气候一植被关系模型(Penman模型、Holdridge生命地带系统、和Kira方法Thomthwaite模型)在中国应用的一致性和适用性。结果表明:(1) Penman模型在温带草原区和青藏高原地区的一致性指数超过50%,在青藏高原最出色,最有发展潜力。(2) Thornthwaite模型在热带雨林、季雨林区达到39. 72%,可以弥补Holdridg模型在热带地区分类精度的不足。(3) Holdridg生命地带系统在不同地带间适用性最广;只在热带地区,例如西部季雨林、雨林区域(52)、西部草原亚区域(63)和青藏高原温性荒漠地带(86)以及青藏高原温性草原地带(84)不理想。(4)吉良(Kira)方法在亚热带常绿阔叶林区可与Holdridg模型相媲美;在低海拔和湿润、半湿润地区效果尚可,但在温带荒漠区与青藏高原区的模拟效果与实际相差较远。 这四个传统的分类方法在中国植被区划一级分类上是适用的,Holdridge生命地带系统KAPPA -致性指数达到0.57模拟效果优于其它三者,但在特定地区,如青藏高原,所有模型均需改进优化或启用新的模型因子才能很好地区分植被亚地带。本研究还指出,数字地球技术的应用有助于推动气候一植被关系的研究,尤其在气候一植被指标(气候参数和模型参数)的大范围实时动态监测、气候一植被关系数据的海量信息高效、有序基础管理和功能型模型库支撑框架体系方面。
Resumo:
Introduction. Leaf area is often related to plant growth, development, physiology and yield. Many non-destructive models have been proposed for leaf area estimation of several plant genotypes, demonstrating that leaf length, leaf width and leaf area are closely correlated. Thus, the objective of our study was to develop a reliable model for leaf area estimation from linear measurements of leaf dimensions for citrus genotypes. Materials and methods. Leaves of citrus genotypes were harvested, and their dimensions (length, width and area) were measured. Values of leaf area were regressed against length, width, the square of length, the square of width and the product (length x width). The most accurate equations, either linear or second-order polynomial, were regressed again with a new data set; then the most reliable equation was defined. Results and discussion. The first analysis showed that the variables length, width and the square of length gave better results in second-order polynomial equations, while the linear equations were more suitable and accurate when the width and the product (length x width) were used. When these equations were regressed with the new data set, the coefficient of determination (R(2)) and the agreement index 'd' were higher for the one that used the variable product (length x width), while the Mean Absolute Percentage Error was lower. Conclusion. The product of the simple leaf dimensions (length x width) can provide a reliable and simple non-destructive model for leaf area estimation across citrus genotypes.
Resumo:
O presente estudo objetivou analisar a qualidade do diagnóstico de biopsias colhidas com agulhas tipo aspirativa e cortante, comparando-as ao exame histológico post-mortem do fígado de cães portadores de afecções hepáticas. Foram utilizados 60 cães, sem distinção de sexo, raça ou idade. As biopsias foram procedidas com agulhas tipo MenghiniÒ (de natureza aspirativa) e agulhas tipo Tru-CutÒ (de natureza cortante). As biopsias foram colhidas utilizando-se a técnica percutânea transabdominal. O diagnóstico referente à agulha tipo Tru-CutÒ não diferiu do diagnóstico referente à agulha tipo MenghiniÒ. O referente à agulha tipo Tru-CutÒ foi o que apresentou maior índice de concordância, 88,3% de acertos. A agulha tipo Tru-CutÒ apresentou excelentes resultados independente da natureza das lesões, enquanto que a agulha tipo MenghiniÒ falhou nos casos de fibrose.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
As regiões escolhidas para o estudo são importantes no cenário citrícola irrigado, tanto em expansão quanto em atuação. Os dados meteorológicos utilizados para as estimativas são integrantes do banco de dados climáticos do software IRRIPLUS®. Com este software, estimou-se a evapotranspiração de referência (ETo) diária, utilizando as metodologias propostas por Penman-Monteith (EToPM), Hargreaves & Samani (EToHG) e Blaney-Criddle-FAO (EToBC), para o período de um ano. O objetivo deste estudo foi comparar os métodos de estimativa com EToPM, utilizando parâmetros de regressão (β0, β1), coeficiente de determinação (r²), e correlação (r), estimativa do erro-padrão (SEE), índices de concordância (d) e confiança (c). Os resultados indicam tendência de EToHG à superestimativa dos valores de ETo, exceto na região de Jaú, e subestimativa por EToBC, para todas as regiões estudadas. Nos valores mensais de ETo, os três métodos apresentam a mesma distribuição. O método de EToHG apresenta-se como uma excelente alternativa na estimativa de consumo de água pela cultura.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective of the present study was to compare the performance of three serological tests for diagnosis of Brucella abortus infections in buffaloes (Bubalus bubalis). Serum samples collected from 696 adult females were submitted to the competitive enzyme-linked immunosorbent assay (ELISAC), (I-ELISA), fluorescence polarization test (FPA), 2-mercaptoethanol test (2-ME) and complement fixation test (CFT). The gold standard was the combination of CFT and 2-ME, considering as positive the reactors in both CFT and 2-ME, and as negative those non-reactors. ROC analyses were done for C-ELISA, I-ELISA and FPA and the Kappa agreement index were also calculated. The best combinations of relative sensitivity (SEr) and relative specificity (SPr) and Kappa were given by C-ELISA (96.9%, 99.1%, and 0.932, respectively) and FPA (92.2%, 97.6 and 0.836, respectively). The C-ELISA and FPA were the most promising confirmatory tests for the serological diagnosis of brucellosis in buffaloes, and for these tests, cut-off values for buffaloes may be the same as those used for bovines.
Resumo:
Objective: to determine the ability of the reduced form of a screening instrument, the Patient Health Questionnaire-2 (PHQ-2), to assess the presence of depressive disorders in patients admitted to a general hospital. Method: A sample of 227 patients admitted to the clinical wards of a Brazilian general university hospital were assessed with Module A of the Diagnostic Structured Interview for the DSM-IV (SCID-IV) and filled out the PHQ-9 and PHQ-2. Results: The PHQ-2 demonstrated an area under the ROC curve of 0.89 (p < 0.0001), with a cutoff point of three or more being the one that best equilibrated the sensitivity (0.86) and specificity (0.75) values. The agreement index between the PHQ-2 and module A of SCID-W was 78.4% and the Kappa value was 0.51. Regarding reliability, the Cronbach alpha value obtained was 0.64 and the intraclass correlation coefficient was 0.52. Conclusion: PHQ-2 proved to be an instrument with good psychometric properties comparable to those of PHQ-9, being superior to the latter regarding the rate of false-positive results. In addition, it is a brief instrument that elicits little resistance on the part of the patient, being inexpensive and requiring little time, thus being of important help to the treatment teams for the detection of depressive disorder, being suitable for incorporation into hospital admission protocols and thus possibly favoring more immediate interventions. (Int'l J. Psychiatry in Medicine 2012;44:141-148)
Resumo:
The Nursing Home Survey on Patient Safety Culture (NHSPSC) was specifically developed for nursing homes to assess a facility’s safety climate and it consists of 12 dimensions. After its pilot testing, however, no fur- ther psychometric analyses were performed on the instrument. For this study of safety climate in Swiss nursing home units, the NHSPSC was linguistically adapted to the Swiss context and to address the unit as well as facility level, with the aim of testing aspects of the validity and reliability of the Swiss version before its use in Swiss nursing home units. Psychometric analyses were performed on data from 367 nurs- ing personnel from nine nursing homes in the German-speaking part of Switzerland (response rate = 66%), and content validity (CVI) examined. The statistical influence of unit membership on respondents’ answers, and on their agreement concerning their units’ safety climate, was tested using intraclass corre- lation coefficients (ICCs) and the rWG(J) interrater agreement index. A multilevel exploratory factor analysis (MEFA) with oblimin rotation was applied to examine the questionnaire’s dimensionality. Cronbach’s alpha and Raykov’s rho were calculated to assess factor reliability. The relationship of safety climate dimensions with clinical outcomes was explored. Expert feedback confirmed the relevance of the instru- ment’s items (CVI = 0.93). Personnel showed strong agreement in their perceptions in three dimensions of the questionnaire. ICCs supported a multilevel analysis. MEFA produced nine factors at the within-level (in comparison to 12 in the original version) and two factors at the between-level with satisfactory fit statis- tics. Raykov’s Rho for the single level factors ranged between 0.67 and 0.86. Some safety climate dimen- sions show moderate, but non-significant correlations with the use of bedrails, physical restraint use, and fall-related injuries. The Swiss version of the NHSPSC needs further refinement and testing before its use can be recommended in Swiss nursing homes: its dimensionality needs further clarification, particularly to distinguish items addressing the unit-level safety climate from those at the facility level.
Resumo:
The crystal structure of kyzylkumite, ideally Ti2V3+O5(OH), from the Sludyanka complex in South Baikal, Russia was solved and refined (including the hydrogen atom position) to an agreement index, R1, of 2.34 using X-ray diffraction data collected on a twinned crystal. Kyzylkumite crystallizes in space group P21/c, with a = 8.4787(1), b = 4.5624(1), c = 10.0330(1) Å, β = 93.174(1)°, V = 387.51(1) Å3 and Z = 4. Tivanite, TiV3+O3OH, and kyzylkumite have modular structures based on hexagonal close packing of oxygen, which are made up of rutile TiO2 and montroseite V3+O(OH) slices. In tivanite the rutile:montroseite ratio is 1:1, in kyzylkumite the ratio is 2:1. The montroseite module may be replaced by the isotypic paramontroseite V4+O2 module, which produces a phase with the formula Ti2V4+O6. In the metamorphic rocks of the Sludyanka complex, vanadium can be present as V4+ and V3+ within the same mineral (e.g. in batisivite, schreyerite and berdesinskiite). Kyzylkumite has a flexible composition with respect to the M4+/M3+ ratio. The relationship between kyzylkumite and a closely related Be-bearing kyzylkumite-like mineral with an orthorhombic norbergite-type structure from Byrud mine, Norway is discussed. Both minerals have similar X-ray powder diffraction patterns.
Resumo:
The Nursing Homes are an important alternative care in the world, but Brazil still has no valid instrument to monitor the quality these institutions. In the United States, the Observable Indicators of Nursing Home Care Quality Instrument (OIQ) is used to assess the quality of Nursing Home care using 30 indicators of structure (2 dimensions) and process (5 dimensions) related to quality person-centered care. The present study aimed at cross-culturally adapting the OIQ in order to evaluate the quality of Nursing Home care in Brazil. Conceptual and item equivalence were determined to assess the relevance and viability of OIQ in the Brazilian context, using the Content Validity Index (CVI) and a group of specialists composed of 10 participants directly involved in the object of study. Next, operational, idiomatic and semantic equivalence were carried out concurrently. This consisted of 5 phases: (1) two translations and (2) their respective back translations; (3) formal appraisal of referential and general meaning; (4) review by a second group of specialists; (5) application of the pretest at three Nursing Homes by different social entities: health professionals, sanitary surveillance regulators and potential consumers. Measurement equivalence was evaluated by the Cronbach’s alpha test to verify the internal consistency of the instrument. To measure inter-evaluator agreement, the General Agreement Index (ICG) and Kappa coefficient were used. Timely compliance and 95% Confidence Interval of indicators, dimensions and total construct were estimated. The CVI obtained high results for both relevance (95.3%) and viability (94.3%) in the Brazilian context. With respect to referential meaning, similarity was observed, ranging between 90-100% for the first back translation and 70-100% for the second. In relation to general meaning, version 1 was better, classified as “unchanged” in 80% of the items, whereas in version 2 it was only 47%. In the pretest, the OIQ was easy to understand and apply. The following outcomes were obtained: a high Cronbach’s alpha (0.93), satisfactory ICG (75%) and substantial agreement between the pairs of evaluators (health professionals, regulators from the Superintendency of Sanitary Surveillance –SUVISA-, and potential consumers), according to the Kappa coefficient (0.65). It´s possible take the operational equivalence held since it preserved the original layout in the Brazilian version from the maintenance in application mode, response options, number of items, statements and scores. The performance of nursing homes obtained approximate average scores of 87, a variation 55-111 considering a range from 30 to 150 points. The worst outcomes were related to process indicators with a mean of 2.8 per item, while structure was 3.75 on a scale of 1 to 5. The lowest score was obtained for the care dimension (mean 2). The OIQ version was deemed to be a valid and reliable instrument in the Brazilian context. It is recommended that health professionals, regulators and potential consumers adopt it to access and monitor the quality of Nursing Home care and demonstrating opportunities for improvement.
Resumo:
Reconstructions of eolian dust accumulation in northwest African margin sediments provide important continuous records of past changes in atmospheric circulation and aridity in the region. Existing records indicate dramatic changes in North African dust emissions over the last 20 ka, but the limited spatial extent of these records and the lack of high-resolution flux data do not allow us to determine whether changes in dust deposition occurred with similar timing, magnitude and abruptness throughout northwest Africa. Here we present new records from a meridional transect of cores stretching from 31°N to 19°N along the northwest African margin. By combining grain size endmember modeling with 230Th-normalized fluxes for the first time, we are able to document spatial and temporal changes in dust deposition under the North African dust plume throughout the last 20 ka. Our results provide quantitative estimates of the magnitude of dust flux changes associated with Heinrich Stadial 1, the Younger Dryas, and the African Humid Period (AHP; ~11.7-5 ka), offering robust targets for model-based estimates of the climatic and biogeochemical impacts of past changes in North African dust emissions. Our data suggest that dust fluxes between 8 and 6 ka were a factor of ~5 lower than average fluxes during the last 2 ka. Using a simple model to estimate the effects of bioturbation on dust input signals, we find that our data are consistent with abrupt, synchronous changes in dust fluxes in all cores at the beginning and end of the AHP. The mean ages of these transitions are 11.8±0.2 ka (1Sigma) and 4.9±0.2 ka, respectively.
Resumo:
En les últimes dècades, l'increment dels nivells de radiació solar ultraviolada (UVR) que arriba a la Terra (principalment degut a la disminució d'ozó estratosfèric) juntament amb l'augment detectat en malalties relacionades amb l'exposició a la UVR, ha portat a un gran volum d'investigacions sobre la radiació solar en aquesta banda i els seus efectes en els humans. L'índex ultraviolat (UVI), que ha estat adoptat internacionalment, va ser definit amb el propòsit d'informar al públic general sobre els riscos d'exposar el cos nu a la UVR i per tal d'enviar missatges preventius. L'UVI es va definir inicialment com el valor màxim diari. No obstant, el seu ús actual s'ha ampliat i té sentit referir-se a un valor instantani o a una evolució diària del valor d'UVI mesurat, modelitzat o predit. El valor concret d'UVI està afectat per la geometria Sol-Terra, els núvols, l'ozó, els aerosols, l'altitud i l'albedo superficial. Les mesures d'UVI d'alta qualitat són essencials com a referència i per estudiar tendències a llarg termini; es necessiten també tècniques acurades de modelització per tal d'entendre els factors que afecten la UVR, per predir l'UVI i com a control de qualitat de les mesures. És d'esperar que les mesures més acurades d'UVI s'obtinguin amb espectroradiòmetres. No obstant, com que els costs d'aquests dispositius són elevats, és més habitual trobar dades d'UVI de radiòmetres eritemàtics (de fet, la majoria de les xarxes d'UVI estan equipades amb aquest tipus de sensors). Els millors resultats en modelització s'obtenen amb models de transferència radiativa de dispersió múltiple quan es coneix bé la informació d'entrada. No obstant, habitualment no es coneix informació d'entrada, com per exemple les propietats òptiques dels aerosols, la qual cosa pot portar a importants incerteses en la modelització. Sovint, s'utilitzen models més simples per aplicacions com ara la predicció d'UVI o l'elaboració de mapes d'UVI, ja que aquests són més ràpids i requereixen menys paràmetres d'entrada. Tenint en compte aquest marc de treball, l'objectiu general d'aquest estudi és analitzar l'acord al qual es pot arribar entre la mesura i la modelització d'UVI per condicions de cel sense núvols. D'aquesta manera, en aquest estudi es presenten comparacions model-mesura per diferents tècniques de modelització, diferents opcions d'entrada i per mesures d'UVI tant de radiòmetres eritemàtics com d'espectroradiòmeters. Com a conclusió general, es pot afirmar que la comparació model-mesura és molt útil per detectar limitacions i estimar incerteses tant en les modelitzacions com en les mesures. Pel que fa a la modelització, les principals limitacions que s'han trobat és la falta de coneixement de la informació d'aerosols considerada com a entrada dels models. També, s'han trobat importants diferències entre l'ozó mesurat des de satèl·lit i des de la superfície terrestre, la qual cosa pot portar a diferències importants en l'UVI modelitzat. PTUV, una nova i simple parametrització pel càlcul ràpid d'UVI per condicions de cel serens, ha estat desenvolupada en base a càlculs de transferència radiativa. La parametrització mostra una bona execució tant respecte el model base com en comparació amb diverses mesures d'UVI. PTUV ha demostrat la seva utilitat per aplicacions particulars com ara l'estudi de l'evolució anual de l'UVI per un cert lloc (Girona) i la composició de mapes d'alta resolució de valors d'UVI típics per un territori concret (Catalunya). En relació a les mesures, es constata que és molt important saber la resposta espectral dels radiòmetres eritemàtics per tal d'evitar grans incerteses a la mesura d'UVI. Aquest instruments, si estan ben caracteritzats, mostren una bona comparació amb els espectroradiòmetres d'alta qualitat en la mesura d'UVI. Les qüestions més importants respecte les mesures són la calibració i estabilitat a llarg termini. També, s'ha observat un efecte de temperatura en el PTFE, un material utilitzat en els difusors en alguns instruments, cosa que potencialment podria tenir implicacions importants en el camp experimental. Finalment, i pel que fa a les comparacions model-mesura, el millor acord s'ha trobat quan es consideren mesures d'UVI d'espectroradiòmetres d'alta qualitat i s'usen models de transferència radiativa que consideren les millors dades disponibles pel que fa als paràmetres òptics d'ozó i aerosols i els seus canvis en el temps. D'aquesta manera, l'acord pot ser tan alt dins un 0.1º% en UVI, i típicament entre menys d'un 3%. Aquest acord es veu altament deteriorat si s'ignora la informació d'aerosols i depèn de manera important del valor d'albedo de dispersió simple dels aerosols. Altres dades d'entrada del model, com ara l'albedo superficial i els perfils d'ozó i temperatura introdueixen una incertesa menor en els resultats de modelització.
Resumo:
Mode of access: Internet.
Resumo:
Background Older adults may find it problematic to attend hospital appointments due to the difficulty associated with travelling to, within and from a hospital facility for the purpose of a face-to-face assessment. This study aims to investigate equivalence between telephone and face-to-face administration for the Frenchay Activities Index (FAI) and the Euroqol-5D (EQ-5D) generic health-related quality of life instrument amongst an older adult population. Methods Patients aged >65 (n = 53) who had been discharged to the community following an acute hospital admission underwent telephone administration of the FAI and EQ-5D instruments seven days prior to attending a hospital outpatient appointment where they completed a face-to-face administration of these instruments. Results Overall, 40 subjects' datasets were complete for both assessments and included in analysis. The FAI items had high levels of agreement between the two modes of administration (item kappa's ranged 0.73 to 1.00) as did the EQ-5D (item kappa's ranged 0.67–0.83). For the FAI, EQ-5D VAS and EQ-5D utility score, intraclass correlation coefficients were 0.94, 0.58 and 0.82 respectively with paired t-tests indicating no significant systematic difference (p = 0.100, p = 0.690 and p = 0.290 respectively). Conclusion Telephone administration of the FAI and EQ-5D instruments provides comparable results to face-to-face administration amongst older adults deemed to have cognitive functioning intact at a basic level, indicating that this is a suitable alternate approach for collection of this information.