999 resultados para Accelerate partial breast irradiation
Resumo:
PURPOSE To analyse the clinical outcome after salvage lumpectomy and multi-catheter brachytherapy (MCB) for ipsilateral breast tumour recurrence (IBTR). MATERIAL AND METHODS Between 09/00 and 09/10, 217 patients presenting an IBTR underwent lumpectomy and MCB (low, pulsed, or high-dose rate). Survival rates without second local recurrence (2nd LR), distant metastasis (DM), and overall survival (OS) were analysed as well as late effects and cosmetic results. Univariate and multivariate analyses (MVA) based on IBTR data were performed to find prognostic factors for 2nd LR, DM, and OS. RESULTS Median follow-up after the IBTR was 3.9 years [range: 1.1-10.3]. Five and 10-year actuarial 2nd LR rates were 5.6% [range: 1.5-9.5] and 7.2% [range: 2.1-12.1], respectively. Five and 10-year actuarial DM rates were 9.6% [range: 5.7-15.2] and 19.1% [range: 7.8-28.3], respectively. Five and 10-year actuarial OS rates were 88.7% [range: 83.1-94.8] and 76.4% [range: 66.9-87.3], respectively. In MVA, histological grade was prognostic factor for 2nd LR (p=0.008) and OS (p=0.02); while tumour size was prognostic factor for DM (p=0.03). G3-4 complication rate was 11%. Excellent/good cosmetic result was achieved in 85%. CONCLUSION This study suggests that in case of IBTR, lumpectomy plus MCB is feasible and effective in preventing 2nd LR with an OS rate at least equivalent to those achieved with salvage mastectomy.
Resumo:
OBJECTIVE The aim was to develop a delineation guideline for target definition for APBI or boost by consensus of the Breast Working Group of GEC-ESTRO. PROPOSED RECOMMENDATIONS Appropriate delineation of CTV (PTV) with low inter- and intra-observer variability in clinical practice is complex and needs various steps as: (1) Detailed knowledge of primary surgical procedure, of all details of pathology, as well as of preoperative imaging. (2) Definition of tumour localization before breast conserving surgery inside the breast and translation of this information in the postoperative CT imaging data set. (3) Calculation of the size of total safety margins. The size should be at least 2 cm. (4) Definition of the target. (5) Delineation of the target according to defined rules. CONCLUSION Providing guidelines based on the consensus of a group of experts should make it possible to achieve a reproducible and consistent definition of CTV (PTV) for Accelerated Partial Breast Irradiation (APBI) or boost irradiation after breast conserving closed cavity surgery, and helps to define it after selected cases of oncoplastic surgery.
Resumo:
BACKGROUND In a phase 3, randomised, non-inferiority trial, accelerated partial breast irradiation (APBI) for patients with stage 0, I, and IIA breast cancer who underwent breast-conserving treatment was compared with whole-breast irradiation. Here, we present 5-year follow-up results. METHODS We did a phase 3, randomised, non-inferiority trial at 16 hospitals and medical centres in seven European countries. 1184 patients with low-risk invasive and ductal carcinoma in situ treated with breast-conserving surgery were centrally randomised to either whole-breast irradiation or APBI using multicatheter brachytherapy. The primary endpoint was local recurrence. Analysis was done according to treatment received. This trial is registered with ClinicalTrials.gov, number NCT00402519. FINDINGS Between April 20, 2004, and July 30, 2009, 551 patients had whole-breast irradiation with tumour-bed boost and 633 patients received APBI using interstitial multicatheter brachytherapy. At 5-year follow-up, nine patients treated with APBI and five patients receiving whole-breast irradiation had a local recurrence; the cumulative incidence of local recurrence was 1·44% (95% CI 0·51-2·38) with APBI and 0·92% (0·12-1·73) with whole-breast irradiation (difference 0·52%, 95% CI -0·72 to 1·75; p=0·42). No grade 4 late side-effects were reported. The 5-year risk of grade 2-3 late side-effects to the skin was 3·2% with APBI versus 5·7% with whole-breast irradiation (p=0·08), and 5-year risk of grade 2-3 subcutaneous tissue late side-effects was 7·6% versus 6·3% (p=0·53). The risk of severe (grade 3) fibrosis at 5 years was 0·2% with whole-breast irradiation and 0% with APBI (p=0·46). INTERPRETATION The difference between treatments was below the relevance margin of 3 percentage points. Therefore, adjuvant APBI using multicatheter brachytherapy after breast-conserving surgery in patients with early breast cancer is not inferior to adjuvant whole-breast irradiation with respect to 5-year local control, disease-free survival, and overall survival. FUNDING German Cancer Aid.
Resumo:
PURPOSE To investigate interobserver variations of target volume delineations in accelerated partial breast irradiation with multicatheter brachytherapy (BT) and to assess the impact of guidelines on consistency of contouring. METHODS AND MATERIALS A contouring study with two phases in interstitial accelerated partial breast irradiation after open cavity surgery was conducted by the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology Breast Cancer Working Group. Contours of cavity and planning target volume (PTV) on preimplant and postimplant CT images were delineated. In Phase 1, nine radiation oncologists defined the target volumes of 5 patients, whereas in Phase 2, four observers draw the contours of 4 patients applying guidelines. In Phase 1, experience in breast BT after open cavity surgery was assessed. The delineations were compared between Phase 1 and Phase 2, the impact of guidelines was assessed, and cavity visualization score was related to consistency of delineations. RESULTS Significant interobserver variability in delineations of lumpectomy cavity and PTV was observed among the participants. Observers with BT experience after open cavity surgery outlined the cavity and PTV more consistently (conformity indexgen: 0.52 vs. 0.48 and 0.59 vs. 0.55 for preimplant and postimplant cavities). For all volumes, the mean Vmax/Vmin was 2.2 vs. 2.8. Having used guidelines all conformity indices increased significantly. For cavity, the increase was 14% and 11%, whereas for the PTV, 28% and 17% on the preimplant and postimplant CT images, respectively. A strong correlation was found between consistency of contours and cavity visualization score. CONCLUSIONS Simple guidelines on defining the lumpectomy cavity significantly increased the consistency of contouring. Reliable consistency of target volume definition can be expected only for good cavity visibility.
Resumo:
Planeamento: aquisição de imagens, simulação, dosimetria clínica. Tratamento. Novas modalidades de irradiação de mama.
Resumo:
The prone position can be used for the planning of adjuvant radiotherapy after conservative breast surgery in order to deliver less irradiation to lung and cardiac tissue. In the present study, we compared the results of three-dimensional conformal radiotherapy planning for five patients irradiated in the supine and prone position. Tumor stage was T1N0M0 in four patients and T1N1M0 in one. All patients had been previously submitted to conservative breast surgery. Breast size was large in three patients and moderate in the other two. Irradiation in the prone position was performed using an immobilization foam pad with a hole cut into it to accommodate the breast so that it would hang down away from the chest wall. Dose-volume histograms showed that mean irradiation doses reaching the ipsilateral lung were 8.3 ± 3.6 Gy with the patient in the supine position and 1.4 ± 1.0 Gy with the patient in the prone position (P = 0.043). The values for the contralateral lung were 1.3 ± 0.7 and 0.3 ± 0.1 Gy (P = 0.043) and the values for cardiac tissue were 4.6 ± 1.6 and 3.0 ± 1.7 Gy (P = 0.079), respectively. Thus, the dose-volume histograms demonstrated that lung tissue irradiation was significantly lower with the patient in the prone position than in the supine position. Large-breasted women appeared to benefit most from irradiation in the prone position. Prone position breast irradiation appears to be a simple and effective alternative to the conventional supine position for patients with large breasts, since they are subjected to lower pulmonary doses which may cause less pulmonary side effects in the future.
Resumo:
Background: Although various techniques have been used for breast conservation surgery reconstruction, there are few studies describing a logical approach to reconstruction of these defects. The objectives of this study were to establish a classification system for partial breast defects and to develop a reconstructive algorithm. Methods: The authors reviewed a 7-year experience with 209 immediate breast conservation surgery reconstructions. Mean follow-up was 31 months. Type I defects include tissue resection in smaller breasts (bra size A/B), including type IA, which involves minimal defects that do not cause distortion; type III, which involves moderate defects that cause moderate distortion; and type IC, which involves large defects that cause significant deformities. Type II includes tissue resection in medium-sized breasts with or without ptosis (bra size C), and type III includes tissue resection in large breasts with ptosis (bra size D). Results: Eighteen percent of patients presented type I, where a lateral thoracodorsal flap and a latissimus dorsi flap were performed in 68 percent. Forty-five percent presented type II defects, where bilateral mastopexy was performed in 52 percent. Thirty-seven percent of patients presented type III distortion, where bilateral reduction mammaplasty was performed in 67 percent. Thirty-five percent of patients presented complications, and most were minor. Conclusions: An algorithm based on breast size in relation to tumor location and extension of resection can be followed to determine the best approach to reconstruction. The authors` results have demonstrated that the complications were similar to those in other clinical series. Success depends on patient selection, coordinated planning with the oncologic surgeon, and careful intraoperative management.
Resumo:
This work aims at investigating the impact of treating breast cancer using different radiation therapy (RT) techniques – forwardly-planned intensity-modulated, f-IMRT, inversely-planned IMRT and dynamic conformal arc (DCART) RT – and their effects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB treatment planning system were compared: Pencil Beam Convolution (PBC) and commercial Monte Carlo (iMC). Seven left-sided breast patients submitted to breast-conserving surgery were enrolled in the study. For each patient, four RT techniques – f-IMRT, IMRT using 2-fields and 5-fields (IMRT2 and IMRT5, respectively) and DCART – were applied. The dose distributions in the planned target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose–volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all techniques provided adequate coverage of the PTV. However, statistically significant dose differences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung and heart than tangential techniques. However, IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Differences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the iMC algorithm predicted.
Resumo:
RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.
Resumo:
The EORTC 22881-10882 trial in 5178 conservatively treated early breast cancer patients showed that a 16 Gy boost dose significantly improved local control, but increased the risk of breast fibrosis. To investigate predictors for the long-term risk of fibrosis, Cox regression models of the time to moderate or severe fibrosis were developed on a random set of 1797 patients with and 1827 patients without a boost, and validated in the remaining set. The median follow-up was 10.7 years. The risk of fibrosis significantly increased (P<0.01) with increasing maximum whole breast irradiation (WBI) dose and with concomitant chemotherapy, but was independent of age. In the boost arm, the risk further increased (P<0.01) if patients had post-operative breast oedema or haematoma, but it decreased (P<0.01) if WBI was given with >6 MV photons. The c-index was around 0.62. Nomograms with these factors are proposed to forecast the long-term risk of moderate or severe fibrosis.
Resumo:
Breast sarcomas are rare neoplasms of the breast that need to be clearly distinguished from the very common breast carcinomas and treated in a multidisciplinary manner modelled after treatment paradigms in other sarcoma locations. An increasing need to differentiate sarcoma sub-types based on molecular characteristics that will also be depicted in differential treatment sensitivities and development of specifically targeted therapies are equally valid in sarcomas in general and in breast sarcomas in particular. Of special interest in breast are sarcomas developing after breast irradiation for a previous breast carcinoma, a scenario that is increasingly common, given the increasing trends of breast conservation in the surgical treatment of breast carcinoma that necessitates the adjuvant use of radiotherapy.
Resumo:
RESUMO: Introdução – A Radioterapia (RT) é uma abordagem terapêutica para tratamento de neoplasia de mama. Contudo, diferentes técnicas de irradiação (TI) podem ser usadas. Objetivos – Comparar 4 TI, considerando a irradiação dos volumes alvo (PTV) e dos órgãos de risco (OAR). Metodologia – Selecionaram-se 7 pacientes com indicação para RT de mama esquerda. Sobre tomografia computorizada foram feitos os contornos do PTV e dos OAR. Foram calculadas 4 planimetrias/paciente para as TI: conformacional externa (EBRT), intensidade modulada com 2 (IMRT2) e 5 campos (IMRT5) e arco dinâmico (DART). Resultados – Histogramas de dose volume foram comparados para todas as TI usando o software de análise estatística, IBM SPSS v20. Com IMRT5 e DART, os OAR recebem mais doses baixas. No entanto, IMRT5 apresenta melhores índices de conformidade e homogeneidade para o PTV. Conclusões – IMRT5 apresenta o melhor índice de conformidade; EBRT e IMRT2 apresentam melhores resultados que DART. Há d.e.s entre as TI, sobretudo em doses mais baixas nos OAR.
Resumo:
Introducción: El carcinoma de mama es el tumor maligno más frecuente entre las mujeres y representa una significativa mortalidad en los países en vías de desarrollo. Según datos del Instituto Nacional de Cancerología en el 2010 se reportaron 672 nuevos casos de cáncer de mama, lo que representó el 18% de todos los tumores malignos en mujeres. Durante las últimas 3 décadas las técnicas quirúrgicas para el tratamiento del cáncer de mama han presentado un cambio significativo y proponen disminución de procedimientos agresivos y radicales, intervenciones como: mastectomía radical modificada, cirugía conservadora y la disección de ganglio centinela son ejemplos claros de esta evolución asociado al incremento de la reconstrucción mamaria inmediata. Metodología: Estudio observacional tipo cohorte retrospectivo en el cual se revisó una base de datos de pacientes con cáncer de mama de las cuales 632 fueron sometidas a mastectomía radical con preservación de piel y complejo areola-pezón y mastectomía radical con preservación de piel sin preservación del complejo areola-pezón, los dos procedimientos asociados a reconstrucción mamaria inmediata y se comparó la frecuencia de recaída local entre los dos grupos. Resultados: De las 632 pacientes estudiadas al 30.5% se les realizo preservación del complejo areola pezón. Las mujeres a quienes se les realizó preservación del complejo areola pezón presentaron menor sobrevida a la recaída local a 10 años (80.51%) comparado con las mujeres a quienes no se les preservó el complejo areola pezón (87.40%), sin embargo no se encontró diferencia estadísticamente significativa para determinar que las probabilidades de sobrevida sean diferentes. Discusión: No se evidenció diferencia estadísticamente significativa entre los 2 procedimientos quirúrgicos (con y sin preservación del complejo areola pezón) en relación a la recaída local, estudios retrospectivos no han evidenciado una mayor tasa de recaídas locales en pacientes a quienes se les preserva el complejo areola-pezón, sin embargo hacen falta estudios prospectivos y aleatorizados que puedan otorgar un mayor sustento científico que garantice la seguridad de la preservación del complejo areola-pezón.
Resumo:
Introducción: El carcinoma de mama es el tumor maligno más frecuente entre las mujeres y representa una significativa mortalidad en los países en vías de desarrollo. Según datos del Instituto Nacional de Cancerología en el 2010 se reportaron 672 nuevos casos de cáncer de mama, lo que representó el 18% de todos los tumores malignos en mujeres. Durante las últimas 3 décadas las técnicas quirúrgicas para el tratamiento del cáncer de mama han presentado un cambio significativo y proponen disminución de procedimientos agresivos y radicales, intervenciones como: mastectomía radical modificada, cirugía conservadora y la disección de ganglio centinela son ejemplos claros de esta evolución asociado al incremento de la reconstrucción mamaria inmediata. Metodología: Estudio observacional tipo cohorte retrospectivo en el cual se revisó una base de datos de pacientes con cáncer de mama de las cuales 632 fueron sometidas a mastectomía radical con preservación de piel y complejo areola- pezón y mastectomía radical con preservación de piel sin preservación del complejo areola-pezón, los dos procedimientos asociados a reconstrucción mamaria inmediata y se comparó la frecuencia de recaída local entre los dos grupos. Resultados: De las 632 pacientes estudiadas al 30.5% se les realizo preservación del complejo areola pezón. Las mujeres a quienes se les realizó preservación del complejo areola pezón presentaron menor sobrevida a la recaída local a 10 años (80.51%) comparado con las mujeres a quienes no se les preservó el complejo areola pezón (87.40%), sin embargo no se encontró diferencia estadísticamente significativa para determinar que las probabilidades de sobrevida sean diferentes. Discusión: No se evidenció diferencia estadísticamente significativa entre los 2 procedimientos quirúrgicos (con y sin preservación del complejo areola pezón) en relación a la recaída local, estudios retrospectivos no han evidenciado una mayor tasa de recaídas locales en pacientes a quienes se les preserva el complejo areola-pezón, sin embargo hacen falta estudios prospectivos y aleatorizados que puedan otorgar un mayor sustento científico que garantice la seguridad de la preservación del complejo areola-pezón.