999 resultados para Absorption chiller


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays Solar Cooling systems are becoming popular to reduce the carbon footprint of air conditioning. The use of an absorption chiller connected to solar thermal panels is increasing, but little study has been carried out to assess the advantage of join together an absorption chiller and a desiccant wheel to remove the sensible heat and the latent heat in different ways than the current design adopted in the industry. In this work I assess the possibility of implement a desiccant wheel in a conventional solar cooling system and the possibility of recovering the heat rejected by the absorption chiller which is then used for the regeneration of the desiccant wheel. The implementation of a desiccant wheel and the recovery of the heat rejected could provide a significant energy saving when compared to traditional solar cooling system. The results assist in the practical development of a solar cooling system which simultaneously uses absorption and adsorption technology.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this article, a general definition of the process average temperature has been developed, and the impact of the various dissipative mechanisms on 1/COP of the chiller evaluated. The present component-by-component black box analysis removes the assumptions regarding the generator outlet temperature(s) and the component effective thermal conductances. Mass transfer resistance is also incorporated into the absorber analysis to arrive at a more realistic upper limit to the cooling capacity. Finally, the theoretical foundation for the absorption chiller T-s diagram is derived. This diagrammatic approach only requires the inlet and outlet conditions of the chiller components and can be employed as a practical tool for system analysis and comparison. (C) 2000 Elsevier Science Ltd and IIR. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Portugal é um país dependente da energia do exterior, devido à elevada percentagem de consumo de energia a partir de fontes primárias, como por exemplo o gasóleo. Para colmatar este cenário, têm vindo a criar-se incentivos para o uso de energias renováveis e para intensificação de medidas de eficiência energética, como os sistemas de cogeração, de forma a tornar os processos industriais nacionais mais autónomos e mais competitivos. O presente trabalho, centra-se na avaliação do chiller de absorção na central de trigeração da empresa Monteiro, Ribas-Indústria, SA, com a finalidade de identificar algum problema no funcionamento do chiller. Após efetuado o estudo do chiller, verificou-se que o coeficiente de performance do chiller apresenta valores que variam entre 0,75 e 0,81, que comparado com o valor especificado, não apresenta grande diferença. No que toca à potência do chiller, esta apresentou valores entre 948 e 1045 kW. Estes valores estavam bem abaixo da potência especificada pelos fornecedores. Assim, pretendeu-se propor medidas para melhor a potência obtida. Para o efeito foi sugerido o aquecimento da corrente que atua como fonte de calor para o chiller, a corrente de água quente. Embora a empresa apresente a solução para o problema, um permutador de vapor para o aquecimento da corrente de água quente, este não se encontra em funcionamento contínuo, levando a uma potência mais baixa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study demonstrates the possibility of using an absorption chiller to produce chilled water for air conditioning, and at the same time recover the rejected heat producing domestic hot water. The absorption chiller considered for this application has been sized to suit a standard household and uses a solution of ammonia and water running on hot water at a temperature ranging from 80 - 120°C produced by thermal solar panels. The system consists of five main components: generator, rectifier, condenser, evaporator and absorber, and is divided in two sections at two different pressures. The section at higher pressure includes the generator, rectifier and condenser whereas the section at lower pressure includes the evaporator and the absorber. Heat in this type of system is usually rejected to the environment from the condenser, rectifier and absorber through a cooling tower or air cooler exchanger. In this paper we describe how to recover this heat to create domestic hot water by providing a quantitative evaluation of the amount of energy recovered by the proposed system, if used in the Australian region.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Solar cooling systems are gaining popularity due to continuously increasing of energy costs around the world. However, there are still some factors that are hindering the installation of solar cooling systems on a larger scale. One being the cost associated with the solar collectors required to provide heat to the absorption chiller. This study demonstrates the possibility of reducing the number of solar panels in a residential solar cooling system based on evacuated tubes producing hot water at a low temperature (90 °C) and a water-ammonia absorption chiller.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the large penetration of the natural gas into the Brazilian energy structure, industries such as paper mills and chemical plants are analyzing the feasibility of implementing cogeneration schemes appropriate to this fuel. The analysis of the energy demand patterns of a chemical company from the photographic sector revealed the possibility of using combined cycles or diesel engine cogeneration schemes keeping the existing compression refrigeration units and steam or gas cycle cogeneration systems with absorption refrigeration units. In terms of economic attractiveness, an analysis based on the method of the internal rate of return was performed. The results indicated that the schemes composed by reciprocating engines and combined cycle with compression chillers, as well as the gas cycle scheme with absorption chiller, present return periods of up to 3 years, showing that the investment in cogeneration could be of interest for this plant. (C) 2000 Elsevier B.V. Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cogeneration may be defined as the simultaneous production of electric power and useful heat from the burning of a single fuel. This technique of combined heat and power production has been applied in both the industrial and tertiary sectors. It has been mainly used because of its overall efficiency, and the guarantee of electricity with a low level of environmental impact. The compact cogeneration systems using internal combustion engine as prime movers are thoroughly applied because of the good relationship among cost and benefit obtained in such devices. The cogeneration system of this study consists of an internal combustion engine using natural gas or biogas as fuel, combined with two heat exchangers and an absorption chiller utilising water-ammonia as working mixture. This work presents an energetic and economic comparison between natural gas and biogas as fuel used for the system proposed. The results are useful to identify the feasible applications for this system, such as residential sector in isolated areas, hotels, universities etc. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brazil occupies an outstanding position as a producer and exporter of chicken meat, and the maintenance and expansion of this position require a constant evolution, especially in variables which determine quality. An important quality parameter of poultry meat is the amount of water absorbed by the carcass during processing. In Brazil, carcasses chilling is done by immersion in chilled water. In this process, the carcass is rehydrated and the water lost during transport and initial operations is replaced. At this stage, some care is needed to prevent the absorption of water upper than the level allowed by Brazilian law. This project aimed to evaluate extrinsic factors that can influence the absorption of water by the chicken meat. For this, 144 Cobb chickens divided into 24 groups of six birds were used. At 42 days of age, one chicken of each group, with weight ranging up to 10% more or less from the average of the group, was slaughtered in an experimental pilot scale abattoir where slaughter procedures were conducted under strictly controlled conditions. The chilling procedure was performed following a completely randomized design with factorial arrangement 3x2, where the factors were: three temperatures in the first section of the chilling system (4, 10 and 16ºC) and two degrees of water hardness (hard and soft water), with six treatments and four replications. Brazilian law provides that the water temperature in the first section of the chiller must not be higher than 16ºC, and the length of the carcasses in this section shall not exceed 30 minutes. All carcasses remained in the first section of the chiller for 30 minutes and then were transferred to another tank with water at 4ºC, remaining there until reaching 7ºC. The carcasses were weighed before and after chilling, to evaluate the percentage of water absorbed. The water absorption was influenced by the initial temperature of the water in the chiller and by the water hardness. When initially immersed in water at 4ºC, carcasses water absorption averaged 2.70%, a significantly lower absorption than the values found for the carcasses that were initially immersed in water at 16ºC, 3.83% (p<0.05). The carcasses immersed in water at 10ºC had mean water absorption of 3.66%, not differing from the means observed in the other two treatments (p>0.05). In hard water, the average water absorption was 2.46% and, in soft water, 4.33% (p<0.05). In all treatments, the water absorption did not exceed the limit established by Brazilian legislation, which is a maximum of 8%. This information is important to control the absorption of water by carcasses in chicken meat processing, preventing consumers from being harmed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic Fe—Mn alkoxide of glycerol samples are submitted to controlled heating conditions and examined by IR absorption spectroscopy. On the other hand, the same sample is studied by infrared emission spectroscopy (IRES), upon heating in situ from 100 to 600°C. The spectral techniques employed in this contribution, especially IRES, show that as a result of the thermal treatments ferromagnetic oxides (manganese ferrite) are formed between 350 and 400°C. Some further spectral changes are seen at higher temperatures.