837 resultados para ARTHROPLASTY, REPLACEMENT, KNEE
Resumo:
The purpose of this study was to identify the preoperative predictors of hospital length of stay after primary total knee arthroplasty in a patient population reflecting current trends toward shorter hospitalization and using readily obtainable factors that do not require scoring systems. A single-center, multi-surgeon retrospective chart review of two hundred and sixty consecutive patients who underwent primary total knee arthroplasty was performed. The mean length of stay was 3.0 days. Among the different variables studied, increasing comorbidities, lack of adequate assistance at home, and bilateral surgery were the only multivariable significant predictors of longer length of stay. The study was adequately powered for statistical analyses and the concordance index of the multivariable logistic regression model was 0.815.
Resumo:
Bone defects in revision knee arthroplasty are often located in load-bearing regions. The goal of this study was to determine whether a physiologic load could be used as an in situ osteogenic signal to the scaffolds filling the bone defects. In order to answer this question, we proposed a novel translation procedure having four steps: (1) determining the mechanical stimulus using finite element method, (2) designing an animal study to measure bone formation spatially and temporally using micro-CT imaging in the scaffold subjected to the estimated mechanical stimulus, (3) identifying bone formation parameters for the loaded and non-loaded cases appearing in a recently developed mathematical model for bone formation in the scaffold and (4) estimating the stiffness and the bone formation in the bone-scaffold construct. With this procedure, we estimated that after 3 years mechanical stimulation increases the bone volume fraction and the stiffness of scaffold by 1.5- and 2.7-fold, respectively, compared to a non-loaded situation.
Resumo:
Background: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only.Methods: A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made.Results: The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures.Conclusions: The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. © 2010 Richter et al; licensee BioMed Central Ltd.
Resumo:
The purpose of this study was to identify preoperative predictors of discharge destination after total joint arthroplasty. A retrospective study of three hundred and seventy-two consecutive patients who underwent primary total hip and knee arthroplasty was performed. The mean length of stay was 2.9 days and 29.0% of patients were discharged to extended care facilities. Age, caregiver support at home, and patient expectation of discharge destination were the only significant multivariable predictors regardless of the type of surgery (total knee versus total hip arthroplasty). Among those variables, patient expectation was the most important predictor (P < 0.001; OR 169.53). The study was adequately powered to analyze the variables in the multivariable logistic regression model, which had a high concordance index of 0.969.
Resumo:
Lower Extremity Joint Arthroplasty (LEJA) surgery is an effective way to alleviate painful osteoarthritis. Unfortunately, these surgeries do not normalize the loading asymmetry during the single leg stance phase of gait. Therefore, we examined single leg balance in 234 TJA patients (75 hips, 65 knees, 94 ankles) approximately 12 months following surgery. Patients passed if they maintained single leg balance for 10s with their eyes open. Patients one year following total hip arthroplasty (THA-63%) and total knee arthroplasty (TKA-69%) had similar pass rates compared to a total ankle arthroplasty (TAA-9%). Patients following THA and TKA exhibit better unilateral balance in comparison with TAA patients. It may be beneficial to include a rigorous proprioception and balance training program in TAA patients to optimize functional outcomes.
Resumo:
Objective: To translate, culturally adapt and validate the "Knee Society Score"(KSS) for the Portuguese language and determine its measurement properties, reproducibility and validity. Method: We analyzed 70 patients of both sexes, aged between 55 and 85 years, in a cross-sectional clinical trial, with diagnosis of primary osteoarthritis,undergoing total knee arthroplasty surgery. We assessed the patients with the English version of the KSS questionnaire and after 30 minutes with the Portuguese version of the KSS questionnaire, done by a different evaluator. All the patients were assessed preoperatively, and again at three, and six months postoperatively. Results: There was no statistical difference, using Cronbach's alpha index and the Bland-Altman graphical analysis, for the knees core during the preoperative period (p=1), and at three months (p=0.991) and six months postoperatively (p=0.985). There was no statistical difference for knee function score for all three periods (p=1.0). Conclusion: The Brazilian version of the Knee Society Score is easy to apply, as well providing as a valid and reliable instrument for measuring the knee score and function of Brazilian patients undergoing TKA. Level of Evidence: Level I - Diagnostic Studies Investigating a Diagnostic Test- Testing of previously developed diagnostic criteria on consecutive patients (with universally applied 'gold' reference standard).
Resumo:
OBJETIVO: Traduzir, adaptar culturalmente e validar o "Knee Society Score" (KSS) para a língua portuguesa e verificar suas propriedades de medida, reprodutibilidade e validade. MÉTODO: Avaliados 70 pacientes de ambos os sexos, em estudo clínico transversal, idade entre 55 e 85 anos, osteoartrose primária submetidos a artroplastia total de joelho, com o questionário KSS pelo avaliador 1 (inglês) e após 30 minutos pelo avaliador 2 (português) no pré- operatório e após três e seis meses de pós-operatório. RESULTADOS: O índice alfa de Cronbach e a diagramação de Bland-Altman não detectaram diferença entre as médias das duas avaliações no pré-operatório (p=1,000), com três meses (p=0,991) e seis meses de pós-operatório (p=0,985) na pontuação do joelho e na nota da função do joelho, p=1,000 nos três períodos. CONCLUSÃO: A versão brasileira do Knee Society Score, o Escore da Sociedade do Joelho, mostrou ser um instrumento de fácil compreensão e aplicação; válido e confiável para medir a pontuação e função do joelho de pacientes brasileiros submetidos a ATJ. Nível de Evidências: Estudos diagnósticos - Nivel de Evidência I, Teste de critérios diagnósticos desenvolvidos anteriormente em pacientes consecutivos (com padrão de referência "ouro" aplicado).
Resumo:
BACKGROUND: The majority of total ankle arthroplasty (TAA) systems use extramedullary alignment guides for tibial component placement. However, at least 1 system offers intramedullary referencing. In total knee arthroplasty, studies suggest that tibial component placement is more accurate with intramedullary referencing. The purpose of this study was to compare the accuracy of extramedullary referencing with intramedullary referencing for tibial component placement in total ankle arthroplasty. METHODS: The coronal and sagittal tibial component alignment was evaluated on the postoperative weight-bearing anteroposterior (AP) and lateral radiographs of 236 consecutive fixed-bearing TAAs. Radiographs were measured blindly by 2 investigators. The postoperative alignment of the prosthesis was compared with the surgeon's intended alignment in both planes. The accuracy of tibial component alignment was compared between the extramedullary and intramedullary referencing techniques using unpaired t tests. Interrater and intrarater reliabilities were assessed with intraclass correlation coefficients (ICCs). RESULTS: Eighty-three tibial components placed with an extramedullary referencing technique were compared with 153 implants placed with an intramedullary referencing technique. The accuracy of the extramedullary referencing was within a mean of 1.5 ± 1.4 degrees and 4.1 ± 2.9 degrees in the coronal and sagittal planes, respectively. The accuracy of intramedullary referencing was within a mean of 1.4 ± 1.1 degrees and 2.5 ± 1.8 degrees in the coronal and sagittal planes, respectively. There was a significant difference (P < .001) between the 2 techniques with respect to the sagittal plane alignment. Interrater ICCs for coronal and sagittal alignment were high (0.81 and 0.94, respectively). Intrarater ICCs for coronal and sagittal alignment were high for both investigators. CONCLUSIONS: Initial sagittal plane tibial component alignment was notably more accurate when intramedullary referencing was used. Further studies are needed to determine the effect of this difference on clinical outcomes and long-term survivability of the implants. LEVEL OF EVIDENCE: Level III, retrospective comparative study.
Resumo:
To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48 h afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48 h afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24 h, 48 h, one week, three weeks and two months after the operation (p < 0.05). In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale.
Resumo:
The relative advantages of cruciate retaining or cruciate resecting total knee replacement are still controversial. If the posterior cruciate ligament (PCL) is preserved, it should be properly balanced. In a previous study, it was demonstrated that increasing the flexion gap leads to an anterior translation of the tibia relative to the femur. Based on these results, we hypothesized that cutting the PCL increases the flexion gap and lessens anterior tibial translation.
Resumo:
Impaction bone grafting for reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. We used this technique, in combination with a cemented acetabular component, in the acetabula of 304 hips in 292 patients revised for aseptic loosening between 1995 and 2001. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of 10 years following the index operation. Mean follow-up was 12.4 years (SD 1.5; range 10.0-16.0). Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8%) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared loose radiographically.
Resumo:
The purpose of this study was to identify preoperative predictors of length of stay after primary total hip arthroplasty in a patient population reflecting current trends toward shorter hospitalization and using readily obtainable factors that do not require scoring systems. A retrospective review of 112 consecutive patients was performed. High preoperative pain level and patient expectation of discharge to extended care facilities (ECFs) were the only significant multivariable predictors of hospitalization extending beyond 2 days (P=0.001 and P<0.001 respectively). Patient expectation remained significant after adjusting for Medicare's 3-day requirement for discharge to ECFs (P<0.001). The study was adequately powered to analyze the variables in the multivariable logistic regression model, which had a concordance index of 0.857.
Resumo:
BACKGROUND: Dislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters) or large-diameter (≥36-millimeters) femoral heads. METHODS: All patients who received large-diameter heads (≥36-millimeter) between 2002 and 2005, and who had pre-operative risk factors for dislocation, were identified in the institution's joint registry. Forty-one patients (52 hips) who received large-diameter heads were identified, and these patients were matched to 48 patients (52 hips) in the registry who received small-diameter femoral heads. RESULTS: At mean final follow-up of 62 months (range, 49 to 101 months), both groups achieved excellent functional outcomes as measured by Harris Hip scores, with slightly better final scores in the large-diameter group (90 vs. 83 points). No patient showed any radiographic signs of loosening. No patient dislocated in the large-diameter femoral head group; the smaller-diameter group had a greater rate of dislocation (3.8%, 2 out of 52). CONCLUSIONS: Large-diameter femoral head articulations may reduce dislocation rates in patients who have a high pre-operative risk for dislocation while providing the same functional improvements and safety as small-diameter bearings.
Resumo:
Introducción Los Grupos Relacionados de Diagnóstico (GRD) se han usado para determinar la calidad de la atención en varios sistemas de salud. Esto ha llevado a que se obtengan resultados en el mejoramiento continuo de la atención y del cuidado. El objetivo de este estudio es determinar desenlaces clínicos de los pacientes a quienes se les había realizado reemplazo de articulares según la complejidad clínica definida mediante GRD. Métodos Se realizó un estudio longitudinal descriptivo en el cual se incluyeron todos los pacientes que tuvieron cirugía de reemplazo total de hombro, cadera y rodilla entre 2012 y 2014. Se realizó la estratificación de los pacientes de acuerdo a tres niveles de complejidad dados por el sistema de GRD y se determinaron las proporciones de pacientes para las variables de estancia hospitalaria, enfermedad trombo-embólica, cardiovascular e infección del sitio operatorio. Resultados Se realizaron en total 886 reemplazos articulares de los cuales 40 (4.5%) presentaron complicaciones. Los eventos más frecuentes fueron las complicaciones coronarias, con una presencia de 2.4%. El GRD1, sin complicaciones ni comorbilidades, fue el que presentó mayor número de eventos. La estancia hospitalaria fue de 3.8 a 9.3 días para todos los reemplazos. Conclusiones Contrario a lo planteado en la hipótesis de estudio, se encontró que el primer GRD presentó el mayor número de complicaciones, lo que puede estar relacionado con el tamaño del grupo. Es necesario realizar nuevas investigaciones que soporten el uso de los GRD como herramienta para evaluar desenlaces clínicos.