35 resultados para AHJ


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Linalool-8-monoxygenase, a typical bacterial P-450 heme thiolase, shows a high degree of substrate specificity towards linalool. The active site of the pure enzyme has been probed with a large number of substrate analogues with systematic alterations or conformational variations in the linalool molecule. The comparison of three parameters, the mo→mos conversion of the enzyme as a result of substrate binding monitored at 392 nm, theK D of the analogues giving information about energies of association and the relative turnover as substrate have given information about the space-filling characteristics of the substrates in the enzyme cleft, the number of contacts the molecules make with the respective domains of the enzyme and the distance of the site undergoing hydroxylation from the oxygen site, respectively. The data permit the conclusion that linalool makes contact with the enzyme by hydrogen bonding with the hydroxyl group as well through hydrophobic association with all the eight carbons carrying hydrogen in the molecules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Data on the cardiac characteristics of centenarians are scarce. Our aim was to describe electrocardiogram (ECG) and echocardiography in a cohort of centenarians and to correlate them with clinical data. Methods We used prospective multicenter registry of 118 centenarians (28 men) with a mean age of 101.5 ± 1.7 years. Electrocardiogram was performed in 103 subjects (87.3%) and echocardiography in 100 (84.7%). All subjects underwent a follow-up for at least 6 months. Results Centenarians with abnormal ECG were less frequently females (72% vs 93%), had higher rates of previous consumption of tobacco (14% vs 0) and alcohol (24% vs 12%), and scored lower in the perception of health status (6.8 ± 2.0 vs 8.3 ± 6.8). Centenarians with significant abnormalities in echocardiography were less frequently able to walk 6 m (33% vs 54%). Atrial fibrillation/flutter was found in 27 subjects (26%). Mean left ventricular (LV) ejection fraction was 60.0 ± 10.5%. Moderate or severe aortic valve stenosis was found in 16%, mitral valve regurgitation in 15%, and aortic valve regurgitation in 13%. Diastolic dysfunction was assessed in 79 subjects and was present in 55 (69.6%). Katz index and LV dilation were independently associated with the ability to walk 6 m. Age, Charlson and Katz indexes, and the presence of significant abnormalities in echocardiography were associated with mortality. Conclusions Centenarians have frequent ECG alterations and abnormalities in echocardiography. More than one fifth has atrial fibrillation, and most have diastolic dysfunction. Left ventricular dilation was associated with the ability to walk 6 m. Significant abnormalities in echocardiography were associated with mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Análogos do hormônio juvenil (AHJ) têm sido testados como reguladores de crescimento de Bombyx mori L., com vistas ao incremento da produção de casulos. Esses produtos, quando aplicados em doses adequadas, prolongam o período larval. Os efeitos da aplicação de AHJ podem variar com o produto, a linhagem e o momento de aplicação. Este estudo teve por objetivo avaliar o efeito da aplicação tópica, em diferentes momentos, de três análogos do hormônio juvenil sobre o crescimento dos insetos e a produção de seda da linhagem brasileira C115xN108 do bicho-da-seda. Os produtos piriproxifem, metoprene e fenoxicarbe foram aplicados em larvas do bicho-da-seda a 24h, 48h, 72h e 96h após o início do quinto ínstar (HQI) e seus efeitos sobre características biológicas larvais e adultas e a produção de seda foram avaliados. Independentemente do momento de aplicação, os três produtos afetaram todos os parâmetros avaliados. A reserva de nutrientes acumulada durante o período larval prolongado dos insetos tratados foi destinada ao crescimento das glândulas sericígenas e, também, convertida em peso corporal, com conseqüentes incrementos na produção de seda. Aplicações entre 48 e 72 HQI provocaram os maiores incrementos na biomassa e na produção de casulos de B. mori. Variações no momento de aplicação de 24h e 96h não influenciaram a emergência ou a oviposição de adultos de B. mori, nem a viabilidade dos ovos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Current recommendations for antithrombotic therapy after drug-eluting stent (DES) implantation include prolonged dual antiplatelet therapy (DAPT) with aspirin and clopidogrel >= 12 months. However, the impact of such a regimen for all patients receiving any DES system remains unclear based on scientific evidence available to date. Also, several other shortcomings have been identified with prolonged DAPT, including bleeding complications, compliance, and cost. The second-generation Endeavor zotarolimus-eluting stent (E-ZES) has demonstrated efficacy and safety, despite short duration DAPT (3 months) in the majority of studies. Still, the safety and clinical impact of short-term DAPT with E-ZES in the real world is yet to be determined. Methods The OPTIMIZE trial is a large, prospective, multicenter, randomized (1: 1) non-inferiority clinical evaluation of short-term (3 months) vs long-term (12-months) DAPT in patients undergoing E-ZES implantation in daily clinical practice. Overall, 3,120 patients were enrolled at 33 clinical sites in Brazil. The primary composite endpoint is death (any cause), myocardial infarction, cerebral vascular accident, and major bleeding at 12-month clinical follow-up post-index procedure. Conclusions The OPTIMIZE clinical trial will determine the clinical implications of DAPT duration with the second generation E-ZES in real-world patients undergoing percutaneous coronary intervention. (Am Heart J 2012;164:810-816.e3.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The optimal revascularization strategy for diabetic patients with multivessel coronary artery disease (MVD) remains uncertain for lack of an adequately powered, randomized trial. The FREEDOM trial was designed to compare contemporary coronary artery bypass grafting (CABG) to percutaneous coronary intervention (PCI) with drug-eluting stents in diabetic patients with MVD against a background of optimal medical therapy. Methods A total of 1,900 diabetic participants with MVD were randomized to PCI or CABG worldwide from April 2005 to March 2010. FREEDOM is a superiority trial with a mean follow-up of 4.37 years (minimum 2 years) and 80% power to detect a 27.0% relative reduction. We present the baseline characteristics of patients screened and randomized, and provide a comparison with other MVD trials involving diabetic patients. Results The randomized cohort was 63.1 +/- 9.1 years old and 29% female, with a median diabetes duration of 10.2 +/- 8.9 years. Most (83%) had 3-vessel disease and on average took 5.5 +/- 1.7 vascular medications, with 32% on insulin therapy. Nearly all had hypertension and/or dyslipidemia, and 26% had a prior myocardial infarction. Mean hemoglobin A1c was 7.8 +/- 1.7 mg/dL, 29% had low-density lipoprotein <70 mg/dL, and mean systolic blood pressure was 134 +/- 20 mm Hg. The mean SYNTAX score was 26.2 with a symmetric distribution. FREEDOM trial participants have baseline characteristics similar to those of contemporary multivessel and diabetes trial cohorts. Conclusions The FREEDOM trial has successfully recruited a high-risk diabetic MVD cohort. Follow-up efforts include aggressive monitoring to optimize background risk factor control. FREEDOM will contribute significantly to the PCI versus CABG debate in diabetic patients with MVD. (Am Heart J 2012;164:591-9.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Surgical risk scores, such as the logistic EuroSCORE (LES) and Society of Thoracic Surgeons Predicted Risk of Mortality (STS) score, are commonly used to identify high-risk or “inoperable” patients for transcatheter aortic valve implantation (TAVI). In Europe, the LES plays an important role in selecting patients for implantation with the Medtronic CoreValve System. What is less clear, however, is the role of the STS score of these patients and the relationship between the LES and STS. Objective The purpose of this study is to examine the correlation between LES and STS scores and their performance characteristics in high-risk surgical patients implanted with the Medtronic CoreValve System. Methods All consecutive patients (n = 168) in whom a CoreValve bioprosthesis was implanted between November 2005 and June 2009 at 2 centers (Bern University Hospital, Bern, Switzerland, and Erasmus Medical Center, Rotterdam, The Netherlands) were included for analysis. Patient demographics were recorded in a prospective database. Logistic EuroSCORE and STS scores were calculated on a prospective and retrospective basis, respectively. Results Observed mortality was 11.1%. The mean LES was 3 times higher than the mean STS score (LES 20.2% ± 13.9% vs STS 6.7% ± 5.8%). Based on the various LES and STS cutoff values used in previous and ongoing TAVI trials, 53% of patients had an LES ≥15%, 16% had an STS ≥10%, and 40% had an LES ≥20% or STS ≥10%. Pearson correlation coefficient revealed a reasonable (moderate) linear relationship between the LES and STS scores, r = 0.58, P < .001. Although the STS score outperformed the LES, both models had suboptimal discriminatory power (c-statistic, 0.49 for LES and 0.69 for STS) and calibration. Conclusions Clinical judgment and the Heart Team concept should play a key role in selecting patients for TAVI, whereas currently available surgical risk score algorithms should be used to guide clinical decision making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Impaired response to antiplatelet therapy with acetylsalicylic acid (ASA) and clopidogrel (CLO) has been associated with an increased risk of stent thrombosis and ischemic events after coronary stent implantation. We sought to investigate whether patients with a low response (LR) to ASA or CLO are at increased risk for periprocedural and short-term ischemic events after coronary stent implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although rare, iatrogenic left main coronary artery (LM) dissection is a feared complication of coronary catheterization. Its incidence, optimal therapeutic management, and prognosis remain largely unknown. The aim of the present study was to estimate the incidence, characterize the population at risk, depict the initial management, and evaluate the long-term prognosis of iatrogenic LM dissection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The conventional surgical aortic bioprostheses used for treatment of aortic stenosis (AS) are inherently stenotic in nature. The more favorable mechanical profile of the Medtronic CoreValve bioprosthesis may translate into a better hemodynamic and neurohormonal response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies report that intracoronary administration of autologous bone marrow mononucleated cells (BM-MNCs) may improve remodeling of the left ventricle after acute myocardial infarction (AMI). Subgroup analysis suggest that early treatment between days 4 and 7 after AMI is probably most effective; however, the optimal time point of intracoronary cell administration has never been addressed in clinical trials. Furthermore, reliable clinical predictors are lacking for identifying patients who are thought to have most benefit from cellular therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites. Methods A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route. Results Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m2) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium–combined safety end point (OR 3.3, 95% CI 1.5-7.1). Conclusion A heart team–based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium–combined safety end point.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vessel angulation and large changes in vessel geometry after stent implantation have been associated with an increased risk of target lesion failure (TLF) using bare-metal stents. Second-generation drug-eluting stents (DES)offer superior conformability and inhibition of neointima. The aim of the study is to investigate the relationship between pre and post-implant vessel geometry and the occurrence of TLF at 1 year after treatment with second-generation DES; and to compare the conformability of Resolute and Xience stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.