50 resultados para AED
Resumo:
Essai critique présenté à la Faculté des études supérieures en vue de l’obtention du grade de M.Sc. en service social
Resumo:
Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons.
Resumo:
Purpose: Nurses and nursing students are often first responders to in-hospital cardiac arrest events; thus they are expected to perform Basic Life Support (BLS) and use an automated external defibrillator (AED) without delay. The aim of this study was to explore the relationship between nursing students’ self-efficacy and performance before and after receiving a particular training intervention in BLS/AED. Materials and methods: Explanatory correlational study. 177 nursing students received a 4-h training session in BLS/AED after being randomized to either a self-directed (SDG) or an instructor-directed teaching group (IDG).1 A validated self-efficacy scale, the Cardiff Test and Laerdal SkillReporter® software were used to assess students’ self-efficacy and performance in BLS/AED at pre-test, post-test and 3-month retention-test. Independent t-test analysis was performed to compare the differences between groups at pre-test. Pearson coefficient (r) was used to calculate the strength of the relationship between self-efficacy and performance in both groups at pre-test, post-test and retention-test. Results: Independent t-tests analysis showed that there were non-significant differences (p-values > 0.05) between groups for any of the variables measured. At pre-test, results showed that correlation between self-efficacy and performance was moderate for the IDG (r = 0.53; p < 0.05) and the SDG (r = 0.49; p < 0.05). At post-test, correlation between self-efficacy and performance was much higher for the SDG (r = 0.81; p < 0.05) than for the IDG (r = 0.32; p < 0.05), which in fact was weaker than at pre-test. Finally, it was found that whereas the correlation between self-efficacy and performance increased from the post-test to the retention-test to almost reach baseline levels for the ILG (r = 0.52; p < 0.05), it slightly decreased in this phase for the SDG (r = 0.77; p < 0.05). Conclusion: Student-directed strategies may be more effective than instructor-directed strategies at promoting self-assessment and, therefore, may help to improve and maintain the relationship between nursing student self-efficacy and actual ability to perform BLS/AED.
Resumo:
Frogs have received increasing attention due to their effectiveness for indicating the environment change. Therefore, it is important to monitor and assess frogs. With the development of sensor techniques, large volumes of audio data (including frog calls) have been collected and need to be analysed. After transforming the audio data into its spectrogram representation using short-time Fourier transform, the visual inspection of this representation motivates us to use image processing techniques for analysing audio data. Applying acoustic event detection (AED) method to spectrograms, acoustic events are firstly detected from which ridges are extracted. Three feature sets, Mel-frequency cepstral coefficients (MFCCs), AED feature set and ridge feature set, are then used for frog call classification with a support vector machine classifier. Fifteen frog species widely spread in Queensland, Australia, are selected to evaluate the proposed method. The experimental results show that ridge feature set can achieve an average classification accuracy of 74.73% which outperforms the MFCCs (38.99%) and AED feature set (67.78%).
Resumo:
In cases whazo zotatLon of the seoondazy pztncipal 8tzo,ae axes along tha light path ,exists, it is always poaeible to detezmlna two dizactions along which plane-polazlaad light ,antazlng the model ,amerCe8 as plene-pela~l,aed light fzom the model. Puzth,az the nat zstazdatton Pot any light path is dlff,azant Prom the lntsgtatad zetazd,ation Pat the l£ght path nogZsctlng the ePfsct or z,atation.
Resumo:
Sudden cardiac arrest (CA) is one of the leading causes of death in Europe. It has been estimated that about 40 % of CA victims have ventricular fibrillation (VF) at the time of the first heart rhythm analysis. The treatment for VF is immediate cardiopulmonary resuscitation (CPR) and rapid defibrillation. The automated external defibrillator (AED) and the concept of public access defibrillation (PAD) may be a key to shortening defibrillation delays. Recent studies have shown that PAD programs are associated with high survival rates from VF when devices have been placed in certain risk sites and used by trained laypersons. Today many public places are equipped with AEDs. The purpose of this study was to find new ways of utilizing layperson defibrillation and promote the concept of public access defibrillation (PAD). The study explored the use of AEDs by non-medical first responders in Finland and cabin crew on board a commercial aircraft. A simulated study was performed to explore the role of dispatcher assistance in layperson CPR and defibrillation. A 15-year follow-up study of 59 one-year survivors after successful out-of-hospital resuscitation was performed to evaluate the long-term quality of life of the CA patients. Although there are many AEDs in use by non-medical first responders in Finland, the results of the study showed that there are large variations between individual first response units. This is considered to be caused by the lack of national standards and regulations that would define a full integration of first-responder programmes into the Emergency Medical Services system. The goal of rapid defibrillation in five minutes after the onset of CA is difficult to achieve in Finland due to sparse population and long distances. Local PAD programs may shorten the defibrillation delays. Dispatcher assistance in defibrillation by a layperson not trained to use an AED seems feasible and does not compromise the performance of CPR. In a simulated study, the quality of mouth-to-mouth ventilation performed by laypersons was found to be better after CPR training compared with performance with dispatcher assistance before training. Training was not found to have an influence on the quality of compressions or defibrillation compared with dispatcher assistance of untrained laypersons. The target groups for CPR and defibrillation training need further evaluation. The placements of the AEDs in public areas should be known by the emergency response center and the location should be marked with an international sign. The finding that once a good neurological outcome after CA is achieved, it can be maintained for more than 10 years, encourages further efforts to improve the survival of CA patients.
Resumo:
Background: The national resuscitation guidelines were published in Finland in 2002 and are based on international guidelines published in 2000. The main goal of the national guidelines, available on the Internet free of charge, is early defibrillation by nurses in an institutional setting. Aim: To study possible changes in cardiopulmonary resuscitation (CPR) practices, especially concerning early defibrillation, nurses and students attitudes of guideline implementation and nurses and students ability to implement the guideline recommendations in clinical practices after publication of the Current Care (CC) guidelines for CPR 2002. Material and methods: CPR practices in Finnish health centres; especially concerning rapid defibrillation programmes, as well as the implementation of CC guidelines for CPR was studied in a mail survey to chief physicians of every health centre in Finland (Study I). The CPR skills using an automated external defibrillator (AED) were compared in a study including Objective stuctured clinical examination (OSCE) of resuscitation skills of nurses and nursing students in Finnish and Swedish hospital and institution (Studies II, III). Attitudes towards CPR-D and CPR guidelines among medical and nursing students and secondary hospital nurses were studied in surveys (Studies IV, V). The nurses receiving different CPR training were compared in a randomized trial including OSCE of CPR skills of nurses in Finnish Hospital (Study VI). Results: Two years after the publication, 40.7% of Finnish health centres used national resuscitation guidelines. The proportion of health centres having at least one AED (66%) and principle of nurse-performed defibrillation without the presence of a physician (42%) had increased. The CPR-D training was estimated to be insufficient regarding basic life support and advanced life support in the majority of health centres (Study I). CPR-D skills of nurses and nursing students in two specific Swedish and Finnish hospitals and institutions (Study II and III) were generally inadequate. The nurses performed better than the students and the Swedish nurses surpassed the Finnish ones. Geriatric nurses receiving traditional CPR-D training performed better than those receiving an Internet-based course but both groups failed to defibrillate within 60 s. Thus, the performance was not satisfactory even two weeks after traditional training (Study VI). Unlike the medical students, the nursing students did not feel competent to perform procedures recommended in the cardiopulmonary resuscitation guidelines including the defibrillation. However, the majority of nursing students felt confident about their ability to perform basic life support. The perceived ability to defibrillate correlated significantly with a positive attitude towards nurse-performed defibrillation and negatively with fear of damaging the patient s heart by defibrillation (Study IV). After the educational intervention, the nurses found their level of CPR-D capability more sufficient than before and felt more confident about their ability to perform defibrillation themselves. A negative attitude toward defibrillation correlated with perceived negative organisational attitudes toward cardiopulmonary resuscitation guidelines. After CPR-D education in the hospital, the majority (64%) of nurses hesitated to perform defibrillation because of anxiety and 27 % hesitated because of fear of injuring the patient. Also a negative personal attitude towards guidelines increased markedly after education (Study V). Conclusions: Although a significant change had occurred in resuscitation practices in primary health care after publication of national cardiopulmonary resuscitation guidelines the participants CPR-D skills were not adequate according to the CPR guidelines. The current way of teaching is unlikely to result in participants being able to perform adequate and rapid CPR-D. More information and more frequent training are needed to diminish anxiety concerning defibrillation. Negative beliefs and attitudes toward defibrillation affect the nursing students and nurses attitudes toward cardiopulmonary resuscitation guidelines. CPR-D education increased the participants self-confidence concerning CPR-D skills but it did not reduce their anxiety. AEDs have replaced the manual defibrillators in most institutions, but in spite of the modern devices the anxiety still exists. Basic education does not provide nursing students with adequate CPR-D skills. Thus, frequent training in the workplace has vital importance. This multi-professional program supported by the administration might provide better CPR-D skills. Distance learning alone cannot substitute for traditional small-group learning, tutored hands-on training is needed to learn practical CPR-D skills. Standardized testing would probably help controlling the quality of learning. Training of group-working skills might improve CPR performance.
Resumo:
In this paper a semi analytic model for rotor - stator broadband noise is presented. The work can be split into two sections. The first examines the distortion of the rotor wake in mean swirling flow, downstream of the fan. Previous work by Cooper and Peake4 is extended to include dissipative effects. In the second section we consider the interaction of this gust with the downstream stator row. We examine the way in which an unsteady pressure field is generated by the interaction of this wake flow with the stator blades and obtain estimates for the radiated noise. A new method is presented to extend the well known LINSUB code to the third dimension to capture the effect of the spanwise wavenumber and stator lean and sweep. Copyright © 2008 by Adrian Lloyd and Nigel Peake.
Resumo:
[ES]La fibrilación ventricular (VF) es el primer ritmo registrado en el 40\,\% de las muertes súbitas por paro cardiorrespiratorio extrahospitalario (PCRE). El único tratamiento eficaz para la FV es la desfibrilación mediante una descarga eléctrica. Fuera del hospital, la descarga se administra mediante un desfibrilador externo automático (DEA), que previamente analiza el electrocardiograma (ECG) del paciente y comprueba si presenta un ritmo desfibrilable. La supervivencia en un caso de PCRE depende fundamentalmente de dos factores: la desfibrilación temprana y la resucitación cardiopulmonar (RCP) temprana, que prolonga la FV y por lo tanto la oportunidad de desfibrilación. Para un correcto análisis del ritmo cardiaco es necesario interrumpir la RCP, ya que, debido a las compresiones torácicas, la RCP introduce artefactos en el ECG. Desafortunadamente, la interrupción de la RCP afecta negativamente al éxito en la desfibrilación. En 2003 se aprobó el uso del DEA en pacientes entre 1 y 8 años. Los DEA, que originalmente se diseñaron para pacientes adultos, deben discriminar de forma precisa las arritmias pediátricas para que su uso en niños sea seguro. Varios DEAs se han adaptado para uso pediátrico, bien demostrando la precisión de los algoritmos para adultos con arritmias pediátricas, o bien mediante algoritmos específicos para arritmias pediátricas. Esta tesis presenta un nuevo algoritmo DEA diseñado conjuntamente para pacientes adultos y pediátricos. El algoritmo se ha probado exhaustivamente en bases de datos acordes a los requisitos de la American Heart Association (AHA), y en registros de resucitación con y sin artefacto RCP. El trabajo comenzó con una larga fase experimental en la que se recopilaron y clasificaron retrospectivamente un total de 1090 ritmos pediátricos. Además, se revisó una base de arritmias de adultos y se añadieron 928 nuevos ritmos de adultos. La base de datos final contiene 2782 registros, 1270 se usaron para diseñar el algoritmo y 1512 para validarlo. A continuación, se diseñó un nuevo algoritmo DEA compuesto de cuatro subalgoritmos. Estos subalgoritmos están basados en un conjunto de nuevos parámetros para la detección de arritmias, calculados en diversos dominios de la señal, como el tiempo, la frecuencia, la pendiente o la función de autocorrelación. El algoritmo cumple las exigencias de la AHA para la detección de ritmos desfibrilables y no-desfibrilables tanto en pacientes adultos como en pediátricos. El trabajo concluyó con el análisis del comportamiento del algoritmo con episodios reales de resucitación. En los ritmos que no contenían artefacto RCP se cumplieron las exigencias de la AHA. Posteriormente, se estudió la precisión del algoritmo durante las compresiones torácicas, antes y después de filtrar el artefacto RCP. Para suprimir el artefacto se utilizó un nuevo método desarrollado a lo largo de la tesis. Los ritmos desfibrilables se detectaron de forma precisa tras el filtrado, los no-desfibrilables sin embargo no.
Resumo:
A laboratory trial was conducted in a sea water recirculatory system to study the nutrient digestibility coefficients of diets with varying energy to protein ratios in Japanese flounder Paralicthys olivaceus. Six different experimental diets with two protein levels (45 and 55%) having six different energy to protein ratio of 87, 90, 94, 107, 110 and 114 were formulated using white fish meal and casein as protein sources. The results of the study showed that the apparent protein digestibility (APD) value ranged between 90.59 to 91.61% and there were no significant differences (P>0.05) between the APD values of diets 1, 2, 3, 4 and 6. The apparent lipid digestibility (ALD) values of diets ranged between 88.24 to 90.18%. The apparent energy digestibility (AED) values ranged between 80.55 to 87.52% with diet 3 producing significantly the highest AED value. In general, except in diet 1 the ALD and AED values increased with the increase of dietary lipid at both protein levels. The results of the present investigation indicated that Japanese flounder can efficiently digest the dietary nutrients at varying energy to protein ratios.
Resumo:
We consider the propagation of acoustic waves along a cylindrical duct carrying radially sheared axial mean flow, in which the duct radius is allowed to vary slowly along the axis. In previous work [A.J. Cooper & N. Peake, Journal of Fluid Mechanics 445 (2001) 207-234.] radially sheared axial mean flow with nonzero swirl in a slowly varying duct was considered, but in this paper we set the swirl to zero, thereby allowing simplification of the calculations of both the mean and unsteady flows. In this approach the acoustic wavenumber and corresponding eigenfunction are determined locally, while the wave amplitude is found by solving an evolution equation along the duct. Sample results are presented, including a case in which, perhaps surprisingly, the number of cut-on modes increases as the duct radius decreases. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To evaluate adherence to prescribed antiepileptic drugs (AEDs) in children with epilepsy using a combination of adherence-assessment methods.
Methods: A total of 100 children with epilepsy (=17 years old) were recruited. Medication adherence was determined via parental and child self-reporting (=9 years old), medication refill data from general practitioner (GP) prescribing records, and via AED concentrations in dried blood spot (DBS) samples obtained from children at the clinic and via self- or parental-led sampling in children's own homes. The latter were assessed using population pharmacokinetic modeling. Patients were deemed nonadherent if any of these measures were indicative of nonadherence with the prescribed treatment. In addition, beliefs about medicines, parental confidence in seizure management, and the presence of depressed mood in parents were evaluated to examine their association with nonadherence in the participating children.
Key Findings: The overall rate of nonadherence in children with epilepsy was 33%. Logistic regression analysis indicated that children with generalized epilepsy (vs. focal epilepsy) were more likely (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.37-15.81) to be classified as nonadherent as were children whose parents have depressed mood (OR 3.6, 95% CI 1.16-11.41).
Significance: This is the first study to apply the novel methodology of determining adherence via AED concentrations in clinic and home DBS samples. The present findings show that the latter, with further development, could be a useful approach to adherence assessment when combined with other measures including parent and child self-reporting. Seizure type and parental depressed mood were strongly predictive of nonadherence. © 2013 International League Against Epilepsy.
Key Words: Adherence, Epilepsy, Dried blood spots, MARS, Depressed mood.
Resumo:
Gestión del conocimiento
Resumo:
La douleur est une expérience multidimensionnelle comportant des aspects sensoriels, émotionnels et cognitifs. Théoriquement, des méthodes de mesures comportementales, physiologiques, neurophysiologiques et sensorielles peuvent quantifier la douleur. Peu d’études ont étudié la validation des mesures utilisées en médecine vétérinaire. La recherche combine les travaux de Maîtrise et de Doctorat, traite en partie de la validité de méthodes. Dans cet objectif, nos travaux de recherche étudiaient la validité de méthodes comportementales, physiologiques et neurophysiologiques usuelles pour la mesure de la douleur en comparant les expressions de douleur (vache et chien) chez des animaux contrôle par comparaison à des animaux sous analgésie préventive ou sous traitement curatif suivant une douleur induite par chirurgie (modèles de douleur viscérale bovine ou orthopédique canine) ou causée par une maladie naturelle (arthrose canine). Une première étude comparait les mesures de la douleur entre les vaches du groupe placebo et celles sous analgésie postopératoire sur une durée de 21 jours suivant l’induction d’une douleur viscérale chronique. Les vaches du groupe placebo ont présenté une plus forte sensibilité à la douleur et une diminution de la noradrénaline et de la transthyrétine mesurées dans le liquide cérébro-spinal, une diminution de l’activité motrice (AM) (moindre que dans les groupes avec analgésie), de l’agitation enregistrée par vidéo-analyse et une augmentation du stress selon la mesure de l’activité électrodermique (AED). Les méthodes d’intérêt identifiées étaient les marqueurs spinaux, la mesure de la sensibilisation, de comportements par vidéo-analyse et de l’AM par bio-télémétrie. En utilisant des méthodes semblables à celles précédemment décrites, deux études expérimentales de douleur orthopédique ont été réalisées afin de comparer les réponses à la douleur entre des chiens traités avec une analgésie préventive (opioïdes et anti-inflammatoires, étude #2) ou un biphosphonate (tiludronate, étude #3) par comparaison à des chiens contrôles. Seules les échelles de douleur étaient différentes entre les études de recherche. Pour l’étude #2, les ii chiens sous analgésie ont présenté de plus faibles scores de douleur mesurés avec l’échelle de douleur nommée 4A-VET et ceci simultanément à une faible réponse de l’AED une heure après la chirurgie de trochléoplastie. La fréquence du comportement spontané de ‘la marche avec plein appui de la patte opérée’ mesurée à l’aide de la vidéo-analyse augmentait chez les chiens sous analgésie préventive 24 heures après la chirurgie. L’étude #3 démontrait surtout l’apparition de sensibilisation centrale (à la fois par l’évaluation sensorielle quantitative et les marqueurs spinaux) chez les chiens contrôle, 56 jours après l’induction d’arthrose chirurgicale. Ainsi, les chiens traités avec le tiludronate ont présenté une différence sur la substance P et la transthyrétine cérébro-spinale, une diminution de la sensibilisation périphérique, plus d’appui de la patte opérée lors de la marche selon la mesure du pic de force verticale (PFV), une augmentation de la fréquence de ‘la marche avec plein appui de la patte opérée’. La sensibilisation centrale était associée à la diminution de PFV, et une augmentation de l’AED et du comportement spontané de ‘la marche avec plein appui de la patte opérée’. Pour l’étude #4, la validité et la sensibilité des méthodes ont été évaluées dans une condition d’arthrose naturelle chez des chiens traités avec une diète enrichie en moule verte, un produit ayant des effets anti-inflammatoires et chondroprotecteurs attendus. Les chiens traités présentaient une diminution des scores de douleur via l’échelle nommée CSOM, une augmentation de PFV et une augmentation de l’AM. Dans l’ensemble, les résultats confirment que la vidéo-analyse évaluait la douleur de façon objective et pour des modèles différents de douleur et les marqueurs spinaux sont prometteurs. Le PFV était spécifique de la douleur orthopédique. La sensibilisation était présente lors de douleur pathologique. L’AED n’est pas valide pour la mesure de la douleur. La baisse d’AM suggèrerait un comportement de douleur. Les études étaient exploratoires pour les échelles de douleur en raison de leur niveau (débutant) de développement et du manque d’informations sur les qualités métrologiques de ces mesures.