998 resultados para ADDITIONAL MEASUREMENTS
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
Changes in gene expression have been measured 24 h after injury to mammalian spinal cords that can and cannot regenerate In opossums there is a critical period of development when regeneration stops being possible at 9 days postnatal cervical spinal cords regenerate, at 12 days they do not By the use of marsupial cDNA microarrays we detected 158 genes that respond differentially to injury at the two ages critical for regeneration For selected candidates additional measurements were made by real time PCR and sites of their expression were shown by immunostaining Candidate genes have been classified so as to select those that promote or prevent regeneration Up regulated by injury at 8 days and/or down regulated by injury at 13 days were genes known to promote growth, such as Mitogen activated protein kinase kinase 1 or transcripton factor TCF7L2 By contrast, at 13 days up regulation occurred of Inhibitory molecules including annexins ephrins and genes related to apoptosis and neurodegeneranve diseases Certain genes such as calmodulin 1 and NOGO changed expression similarly in animals that could and could not regenerate without any additional changes in response to injury These findings confirmed and extended changes of gene expression found in earlier screens on 9 and 12 day preparations without lesions and provide a comprehensive list of genes that serve as a basis for testing how identified molecules singly or in combination, promote and prevent central nervous system regeneration (C) 2010 Elsevier B V All rights reserved
Resumo:
This study explores a large set of OC and EC measurements in PM(10) and PM(2.5) aerosol samples, undertaken with a long term constant analytical methodology, to evaluate the capability of the OC/EC minimum ratio to represent the ratio between the OC and EC aerosol components resulting from fossil fuel combustion (OC(ff)/EC(ff)). The data set covers a wide geographical area in Europe, but with a particular focus upon Portugal, Spain and the United Kingdom, and includes a great variety of sites: urban (background, kerbside and tunnel), industrial, rural and remote. The highest minimum ratios were found in samples from remote and rural sites. Urban background sites have shown spatially and temporally consistent minimum ratios, of around 1.0 for PM(10) and 0.7 for PM(2.5).The consistency of results has suggested that the method could be used as a tool to derive the ratio between OC and EC from fossil fuel combustion and consequently to differentiate OC from primary and secondary sources. To explore this capability, OC and EC measurements were performed in a busy roadway tunnel in central Lisbon. The OC/EC ratio, which reflected the composition of vehicle combustion emissions, was in the range of 03-0.4. Ratios of OC/EC in roadside increment air (roadside minus urban background) in Birmingham, UK also lie within the range 03-0.4. Additional measurements were performed under heavy traffic conditions at two double kerbside sites located in the centre of Lisbon and Madrid. The OC/EC minimum ratios observed at both sites were found to be between those of the tunnel and those of urban background air, suggesting that minimum values commonly obtained for this parameter in open urban atmospheres over-predict the direct emissions of OC(ff) from road transport. Possible reasons for this discrepancy are explored. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The aim of the present study was to investigate the effects of continuous and acute L-carnitine supplementation of total parenteral nutrition (TPN) on protein and fat oxidation in severe catabolism. A critically ill and severely malnourished male patient received TPN (non protein energy = 41 kcal/kg/day, provided equally as fat and glucose) over 38 days, without L-carnitine for 23 days and with carnitine supplements (15 mg/kg/day) for the following 15 days. Subsequently, he was given carnitine-free enteral nutrition for 60 more days. A four-hour infusion of 100 mg L-carnitine was given on day 11 of each TPN period. Indirect calorimetry was carried out after 11 days of either carnitine-free or supplemented TPN and at the initiation of enteral nutrition. Additional measurements were performed 4 hours and 24 hours after the acute infusions of carnitine. The rate of protein oxidation and the respiratory quotient were found to be higher, and the rate of fat oxidation to be lower, with carnitine-supplemented TPN, than with either carnitine-free TPN or enteral nutrition. Acute infusion of carnitine resulted in an increased rate of protein oxidation and a reduced rate of fat oxidation on both TPN-regimens. These unfavourable effects on protein metabolism may be due to an impairment of fat oxidation by excess amounts of carnitine.
Resumo:
The paper presents a novel method for monitoring network optimisation, based on a recent machine learning technique known as support vector machine. It is problem-oriented in the sense that it directly answers the question of whether the advised spatial location is important for the classification model. The method can be used to increase the accuracy of classification models by taking a small number of additional measurements. Traditionally, network optimisation is performed by means of the analysis of the kriging variances. The comparison of the method with the traditional approach is presented on a real case study with climate data.
Resumo:
Meesauuni on sulfaattiselluloosan valmistuksen kemikaalikierron apukemikaalin, kalkin valmistukseen käytettävä laite. Rakenteeltaan meesauuni koostuu pyöreästä lievästi horisontaalitasosta kaltevaan asentoon tuetusta putkesta sekä putkea tukevista kannatuselimistä. Meesauunia pyöritetään käytön aikana pituusakselinsa ympäri. Työn tarkoituksena oli rakentaa ADAMS-simulointiohjelmistoon käyttöliittymä meesauunin simulointimallin luomiseen uunin päämittojen avulla. Työssä selvitetään simulointimallin soveltuvuutta uunin kannatuselimiin kohdistuvien voimien tutkimiseen uunin normaaliajossa ja tietyissä ongelmatilanteissa. Työssä suoritettujen simulointien todettiin vastaavan melko hyvin todellista meesauunia ja tukevan ajatusta ADAMS:in käyttämisestä meesauunin mekaniikan simulointiin. Samalla todettiin kuitenkin lisämittausten kehittämisen tarpeellisuus ennen pidemmälle meneviä johtopäätöksiä.
Resumo:
This master’s thesis handles an operating model for an electric equipment supplier conducted sale oriented energy audit for pumping, fan and other motor applications at power plants. The study goes through the largest factors affecting internal electricity use at a power plant, finds an energy audit –like approach for the basis of information gathering and presents the information needed for conducting the analysis. The model is tested in practice at a kraft recovery boiler of a chemical pulping mill. Targets chosen represent some of the largest electric motor applications in the boiler itself and in its fuel handling. The energy saving potential of the chosen targets is calculated by simulating the energy consumption of the alternatives for controlling the targets, and thereafter combining the information with the volume flow duration curve. Results of the research are somewhat divaricated, as all the information needed is not available in the automation system. Some of the targets could be simulated and their energy saving potential calculated quite easily. At some of the targets chosen the monitoring was not sufficient enough for this and additional measurements would have been needed to base the calculations on. In traditional energy audits, energy efficiency of pump and fan applications is not necessarily examined. This means that there are good possibilities for developing the now presented targeted energy audit procedure basis further.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
Centrifugal pumps are a notable end-consumer of electrical energy. Typical application of a centrifugal pump is the filling or emptying of a reservoir tank, where the pump is often operated at a constant speed until the process is completed. Installing a frequency converter to control the motor substitutes the traditional fixed-speed pumping system, allows the optimization of rotational speed profile for the pumping tasks and enables the estimation of rotational speed and shaft torque of an induction motor without any additional measurements from the motor shaft. Utilization of variable-speed operation provides the possibility to decrease the overall energy consumption of the pumping task. The static head of the pumping process may change during the pumping task. In such systems, the minimum rotational speed changes during reservoir filling or emptying, and the minimum energy consumption can’t be achieved with a fixed rotational speed. This thesis presents embedded algorithms to automatically identify, optimize and monitor pumping processes between supply and destination reservoirs, and evaluates the changing static head –based optimization method.
Resumo:
Fan systems are responsible for approximately 10% of the electricity consumption in industrial and municipal sectors, and it has been found that there is energy-saving potential in these systems. To this end, variable speed drives (VSDs) are used to enhance the efficiency of fan systems. Usually, fan system operation is optimized based on measurements of the system, but there are seldom readily installed meters in the system that can be used for the purpose. Thus, sensorless methods are needed for the optimization of fan system operation. In this thesis, methods for the fan operating point estimation with a variable speed drive are studied and discussed. These methods can be used for the energy efficient control of the fan system without additional measurements. The operation of these methods is validated by laboratory measurements and data from an industrial fan system. In addition to their energy consumption, condition monitoring of fan systems is a key issue as fans are an integral part of various production processes. Fan system condition monitoring is usually carried out with vibration measurements, which again increase the system complexity. However, variable speed drives can already be used for pumping system condition monitoring. Therefore, it would add to the usability of a variablespeed- driven fan system if the variable speed drive could be used as a condition monitoring device. In this thesis, sensorless detection methods for three lifetime-reducing phenomena are suggested: these are detection of the fan contamination build-up, the correct rotational direction, and the fan surge. The methods use the variable speed drive monitoring and control options for the detection along with simple signal processing methods, such as power spectrum density estimates. The methods have been validated by laboratory measurements. The key finding of this doctoral thesis is that a variable speed drive can be used on its own as a monitoring and control device for the fan system energy efficiency, and it can also be used in the detection of certain lifetime-reducing phenomena.
Resumo:
We present a comparison between experimental and theoretical results for pump/probe multiphoton ionizing transitions of the sodium dimer, initiated by femtosecond laser pulses. It is shown that the motion of vibrational wavepackets in two electronic states is probed simultaneously and their dynamics is reflected in the total Na^+_2 ion signal which is recorded as a function of the time delay between pump and probe pulse. The time dependent quantum calculations demonstrate that two ionization pathways leading to the same final states of the molecularion exist: one gives an oscillating contribution to the ion signal, the other yields a constant background. From additional measurements of the Na^+ -transient photofragmentation spectrum it is deduced that another ionization process leading to different final ionic states exists. The process includes the excitation of a doubly excitedbound Rydberg state. This conclusion is supported by the theoretical simulation.
Resumo:
Spectroscopic catalogues, such as GEISA and HITRAN, do not yet include information on the water vapour continuum that pervades visible, infrared and microwave spectral regions. This is partly because, in some spectral regions, there are rather few laboratory measurements in conditions close to those in the Earth’s atmosphere; hence understanding of the characteristics of the continuum absorption is still emerging. This is particularly so in the near-infrared and visible, where there has been renewed interest and activity in recent years. In this paper we present a critical review focusing on recent laboratory measurements in two near-infrared window regions (centred on 4700 and 6300 cm−1) and include reference to the window centred on 2600 cm−1 where more measurements have been reported. The rather few available measurements, have used Fourier transform spectroscopy (FTS), cavity ring down spectroscopy, optical-feedback – cavity enhanced laser spectroscopy and, in very narrow regions, calorimetric interferometry. These systems have different advantages and disadvantages. Fourier Transform Spectroscopy can measure the continuum across both these and neighbouring windows; by contrast, the cavity laser techniques are limited to fewer wavenumbers, but have a much higher inherent sensitivity. The available results present a diverse view of the characteristics of continuum absorption, with differences in continuum strength exceeding a factor of 10 in the cores of these windows. In individual windows, the temperature dependence of the water vapour self-continuum differs significantly in the few sets of measurements that allow an analysis. The available data also indicate that the temperature dependence differs significantly between different near-infrared windows. These pioneering measurements provide an impetus for further measurements. Improvements and/or extensions in existing techniques would aid progress to a full characterisation of the continuum – as an example, we report pilot measurements of the water vapour self-continuum using a supercontinuum laser source coupled to an FTS. Such improvements, as well as additional measurements and analyses in other laboratories, would enable the inclusion of the water vapour continuum in future spectroscopic databases, and therefore allow for a more reliable forward modelling of the radiative properties of the atmosphere. It would also allow a more confident assessment of different theoretical descriptions of the underlying cause or causes of continuum absorption.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
BACKGROUND/OBJECTIVES: To assess the performance of a food frequency questionnaire (FFQ) for estimating omega-3, omega-6 and trans fatty acid intake during pregnancy. Moreover, we determined whether the fatty acid composition of mature breast milk represents a valuable biomarker for fatty acid intake during pregnancy. SUBJECTS/METHODS: A prospective study in 41 pregnant women, aged 18-35 years, was conducted. Food intake during pregnancy was evaluated by three 24-h recalls (24 hR), and 2 FFQ. The fatty acid composition of mature breast milk was determined by gas chromatography. The method of triads and joint classification between quartiles of intake were applied. RESULTS: The FFQ was accurate for estimating docosahexanoic (DHA), linoleic and total omega-6 fatty acids according to validity coefficients. Higher agreements (>70%) into the same or adjacent quartiles between the dietary methods were found for alpha-linolenic, total omega-3, linoleic and trans fatty acid intake. High validity coefficients for eicosapentanoic (EPA) and DHA acids of human milk were found (0.61 and 0.73, respectively), and the method was adequate for categorizing the intake of alpha-linolenic, total omega-3 and trans fatty acids compared with FFQ estimates, and for arachidonic acid and trans fatty acids compared with food recall estimates, during pregnancy. CONCLUSIONS: The FFQ was an accurate tool for categorizing alpha-linolenic, total omega-3 and trans fatty acid intake. According to the validity coefficients observed, the FFQ accurately estimated DHA, linoleic and total omega-6 fatty acids and the composition of mature breast milk was shown to be a suitable biomarker for EPA and DHA fatty acid intake during pregnancy.
Resumo:
Die elektromagnetischen Nukleon-Formfaktoren sind fundamentale Größen, welche eng mit der elektromagnetischen Struktur der Nukleonen zusammenhängen. Der Verlauf der elektrischen und magnetischen Sachs-Formfaktoren G_E und G_M gegen Q^2, das negative Quadrat des Viererimpulsübertrags im elektromagnetischen Streuprozess, steht über die Fouriertransformation in direkter Beziehung zu der räumlichen Ladungs- und Strom-Verteilung in den Nukleonen. Präzise Messungen der Formfaktoren über einen weiten Q^2-Bereich werden daher für ein quantitatives Verständnis der Nukleonstruktur benötigt.rnrnDa es keine freien Neutrontargets gibt, gestaltet sich die Messung der Neutron-Formfaktoren schwierig im Vergleich zu der Messung am Proton. Konsequenz daraus ist, dass die Genauigkeit der vorhandenen Daten von Neutron-Formfaktoren deutlich geringer ist als die von Formfaktoren des Protons; auch der vermessene Q^2-Bereich ist kleiner. Insbesondere der elektrische Sachs-Formfaktor des Neutrons G_E^n ist schwierig zu messen, da er aufgrund der verschwindenden Nettoladung des Neutrons im Verhältnis zu den übrigen Nukleon-Formfaktoren sehr klein ist. G_E^n charakterisiert die Ladungsverteilung des elektrisch neutralen Neutrons und ist damit besonders sensitiv auf die innere Struktur des Neutrons.rnrnIn der hier vorgestellten Arbeit wurde G_E^n aus Strahlhelizitätsasymmetrien in der quasielastischen Streuung vec{3He}(vec{e}, e'n)pp bei einem Impulsübertrag von Q^2 = 1.58 (GeV/c)^2 bestimmt. Die Messung fand in Mainz an der Elektronbeschleunigeranlage Mainzer Mikrotron innerhalb der A1-Kollaboration im Sommer 2008 statt. rnrnLongitudinal polarisierte Elektronen mit einer Energie von 1.508 GeV wurden an einem polarisierten ^3He-Gastarget, das als effektives, polarisiertes Neutrontarget diente, gestreut. Die gestreuten Elektronen wurden in Koinzidenz mit den herausgeschlagenen Neutronen detektiert; die Elektronen wurden in einem magnetischen Spektrometer nachgewiesen, durch den Nachweis der Neutronen in einer Matrix aus Plastikszintillatoren wurde der Beitrag der quasielastischen Streuung am Proton unterdrückt.rnrnAsymmetrien des Wirkungsquerschnitts bezüglich der Elektronhelizität sind bei Orientierung der Targetpolarisation in der Streuebene und senkrecht zum Impulsübertrag sensitiv auf G_E^n / G_M^n; mittels deren Messung kann G_E^n bestimmt werden, da der magnetische Formfaktor G_M^n mit vergleichsweise hoher Präzision bekannt ist. Zusätzliche Messungen der Asymmetrie bei einer Polarisationsorientierung parallel zum Impulsübertrag wurden genutzt, um systematische Fehler zu reduzieren.rnrnFür die Messung inklusive statistischem (stat) und systematischem (sys) Fehler ergab sich G_E^n = 0.0244 +/- 0.0057_stat +/- 0.0016_sys.