310 resultados para ABDOMINIS MUSCULOCUTANEOUS FLAPS
Resumo:
QUESTIONS UNDER STUDY: With the reduction in breast cancer mortality in recent years the aesthetic outcome after treatment has gained increasing attention. The aim of this study was to assess the outcome quality of our single institution concept of free TRAM flap breast reconstruction with the aim of providing data to assist the patient's decision-making when breast reconstruction is an option. PRINCIPLES/METHODS: Thirty-two consecutive patients receiving immediate (n = 14) or delayed (n = 18) breast reconstruction with free transverse rectus abdominis musculocutaneous (TRAM) flaps were included. The selection of patients was based on their own wish and the availability of abdominal tissue, without excluding patients at risk for wound healing complications. Patient data were assessed prospectively and the aesthetic outcome was rated after the final result had been achieved. RESULTS: Ten patients sustained wound healing complications (4 of 9 smokers, 8 of 16 patients with a BMI over 25 kg/m2), 8 of them requiring revisional surgery. An average of 1.06 corrective procedures were performed per patient. The aesthetic outcome was judged to be good by 20 patients, fair by 5 and poor by 1 patient who sustained severe tissue loss. CONCLUSIONS: Our results revealed that a large measure of satisfaction is achievable from breast reconstruction with free TRAM flaps, in spite of the invasive nature of the procedure and the inclusion of patients at risk for wound healing complications. These data may be used in the decision-making process by patients eligible for breast reconstruction after mastectomy.
Resumo:
Background: Immediate breast reconstruction after mastectomy has increased over the past decade following the unequivocal demonstration of its oncological safety and the availability of reliable methods of reconstruction. Broadly, it is undertaken in the treatment of breast cancer, after prophylactic mastectomy in high-risk patients, and in the management of treatment failure after breast-conserving surgery and radiotherapy. Immediate breast reconstruction can be achieved reliably with a variety of autogenous tissue techniques or prosthetic devices. Careful discussion and evaluation remain vital in choosing the correct technique for the individual patient.
Methods: This review is based primarily on an English language Medline search with secondary references obtained from key articles.
Results and conclusion: Immediate breast reconstruction is a safe and acceptable procedure after mastectomy for cancer; there is no evidence that it has untoward oncological consequences. In the appropriate patient it can be achieved effectively with either prosthetic or autogenous tissue reconstruction. Patient selection is important in order to optimize results, minimize complications and improve quality of life, while simultaneously treating the malignancy. Close cooperation and collaboration between the oncological breast and reconstructive achieve these objectives.
Resumo:
Breast reconstruction is performed for 10-15 % of women operated on for breast cancer. A popular method is the TRAM (transverse rectus abdominis musculocutaneous) flap formed of the patient’s own abdominal tissue, a part of one of the rectus abdominis muscles and a transverse skin-subcutis area over it. The flap can be raised as a pedicled or a free flap. The pedicled TRAM flap, based on its nondominant pedicle superior epigastric artery (SEA), is rotated to the chest so that blood flow through SEA continues. The free TRAM flap, based on its dominant pedicle deep inferior epigastric artery (DIEA), is detached from the abdomen, transferred to the chest, and DIEA and vein are anastomosed to vessels on the chest. Cutaneous necrosis is seen in 5–60 % of pedicled TRAM flaps and in 0–15 % of free TRAM flaps. This study was the first one to show with blood flow measurements that the cutaneous blood flow is more generous in free than in pedicled TRAM flaps. After this study the free TRAM flap has exceeded the pedicled flap in popularity as a breast reconstruction method, although the free flap it is technically a more demanding procedure than the pedicled TRAM flap. In pedicled flaps, a decrease in cutaneous blood flow was observed when DIEA was ligated. It seems that SEA cannot provide sufficient blood flow on the first postoperative days. The postoperative cutaneous blood flow in free TRAM flaps was more stable than in pedicled flaps. Development of cutaneous necrosis of pedicled TRAM flaps could be predicted based on intraoperative laser Doppler flowmetry (LDF) measurements. The LDF value on the contralateral skin of the flap decreased to 43 ± 7 % of the initial value after ligation of the DIEA in flaps developing cutaneous necrosis during the next week. Endothelin-1 (ET-1) is a powerful vasoconstrictory peptide secreted by vascular endothelial cells. A correlation was found between plasma ET-1 concentrations and peripheral vasoconstriction developing during and after breast reconstructions with a pedicled TRAM flap. ET-1 was not associated with the development of cutaneous necrosis. Felodipine, a vasodilating calcium channel antagonist, had no effect on plasma ET-1 concentrations, peripheral vasoconstriction or development of cutaneous necrosis in free TRAM flaps. Body mass index and thickness of abdominal were not associated with cutaneous necrosis in pedicled TRAM flaps.
Resumo:
Major efforts have been undertaken to reduce donor-site morbidity after abdominal flaps, which eventually culminated in the introduction of the deep inferior epigastric perforator (DIEP) flap. However, due to anatomical variations (absence of dominant perforators) and the risk of ischaemic complications, the selection of patients qualifying for a DIEP flap is limited. Furthermore, DIEP flaps can only be used as free flaps. We present our long-term experience with a dissection technique of rectus abdominis myocutaneous (RAM) flaps that was developed to circumvent these drawbacks. The dissection is characterised by preventing to sacrifice any perforators nourishing the flap and by fully preserving the anterior rectus sheath, but not the muscle. The study comprises a consecutive series of prospectively assessed patients, treated between February 2000 and April 2008. A total of 100 fascia-sparing RAM flaps were operated on 97 patients (age 22-84 years, median 64 years). Free flaps were mainly used for breast reconstruction (47 flaps/24 patients), and cranially (34) or caudally (19) pedicled flaps for soft-tissue coverage after sternectomy, urogenital tumour resection or rectum amputation. Eighty patients had a total of 213 risk factors, such as cardiovascular diseases, obesity, hyperlipidaemia, diabetes mellitus, smoking or steroid medication. Partial tissue loss (skin or fat necrosis) occurred in 13 flaps, out of which seven required surgical revision. The ischaemic complications were evenly distributed between the patient subsets. At a follow-up of 2-89 months (median 20 months), one patient showed a flap harvest-related abdominal bulge after bilateral-free transverse rectus abdominis myocutaneous (TRAM) flap. We conclude that the present dissection technique provides maximal perforator-related perfusion and minimal donor-site morbidity even in pedicled flaps and high-risk patients. In free flaps, it may, therefore, be recommended as an alternative to the DIEP flap.
Resumo:
BACKGROUND.: Microvascular free tissue transfer has become increasingly popular in the reconstruction of head and neck defects, but it also has its disadvantages. Tissue engineering allows the generation of neo-tissue for implantation, but these tissues are often avascular. We propose to combine tissue-engineering techniques together with flap prefabrication techniques to generate a prefabricated vascularized soft tissue flap. METHODS: Human dermal fibroblasts (HDFs) labeled with fluorescein diacetate were static seeded onto polylactic-co-glycolic acid-collagen (PLGA-c) mesh. Controls were plain PLGA-c mesh. The femoral artery and vein of the nude rat was ligated and used as a vascular carrier for the constructs. After 4 weeks of implantation, the constructs were assessed by gross morphology, routine histology, Masson trichrome, and cell viability determined by green fluorescence. RESULTS: All the constructs maintained their initial shape and dimensions. Angiogenesis was evident in all the constructs with neo-capillary formation within the PLGA-c mesh seen. HDFs proliferated and filled the interyarn spaces of the PLGA-c mesh, while unseeded PLGA-c mesh remained relatively acellular. Cell tracer study indicated that the seeded HDFs remained viable and closely associated to remaining PLGA-c fibers. Collagen formation was more abundant in the constructs seeded with HDFs. CONCLUSIONS: PLGA-c, enveloped by a cell sheet composed of fibroblasts, can serve as a suitable scaffold for generation of a soft tissue flap. A ligated arteriovenous pedicle can serve as a vascular carrier for the generation of a tissue engineered vascularized flap.
Resumo:
BACKGROUND Tissue engineering of patient-specific adipose tissue has the potential to revolutionize reconstructive surgery. Numerous models have been described for the production of adipose tissue with success in the short term, but little has been reported on the stability of this tissue-engineered fat beyond 4 months. METHODS A murine model of de novo adipogenesis producing a potentially transplantable adipose tissue flap within 4 to 6 weeks was developed in the authors' laboratory. In this study, the authors assess the ability of three-chamber (44-μl volume) configurations shown to be adipogenic in previous short-term studies (autograft, n = 8; open, n = 6; fat flap, n = 11) to maintain their tissue volume for up to 12 months in vivo, to determine the most adipogenic configuration in the long term. RESULTS Those chambers having the most contact with existing vascularized adipose tissue (open and fat flap groups) showed increased mean adipose tissue percentage (77 ± 5.6 percent and 81 ± 6.9 percent, respectively; p < 0.0007) and volume (12 ± 6.8 μl and 30 ± 14 μl, respectively; p < 0.025) when compared with short-term controls and greater adipose tissue volume than the autograft (sealed) chamber group (4.9 ± 5.8 μl; p = 0.0001) at 1 year. Inclusion of a vascularized fat flap within the chamber produced the best results, with new fat completely filling the chamber by 1 year. CONCLUSIONS These findings demonstrate that fat produced by tissue engineering is capable of maintaining its volume when the appropriate microenvironment is provided. This has important implications for the application of tissue-engineering techniques in humans.
Resumo:
Control surface effectiveness is an important parameter for any aeroplane. For a hypersonic aircraft, though the power required to operate the flaps is determined by low speed flying conditions, it is imperative to know the effect of flaps at hypersonic speeds. Hence, studies have been done on this topic by aerodynamicists for over 40 years. In spite of this, only a limited data is available in the literature on this subject. This paper discusses the experimental study of the effect of sweep on the aerodynamic characteristics of thin slab delta wings with flaps at hypersonic speeds. For the purpose of this investigation, a novel special thin six-component balance, which has a thickness of 4mm and can be housed inside wings with 8mm thickness, has been designed. The wings had a sweep of 76degrees, 70degrees and 65degrees, t/c of 0.053 and flaps with 12% of wing area and 12% of wing chord. Testing were done at Mach 8.2, Re number of 2.13 x 10(6) (based on chord), from alpha = -12degrees to 12degrees and flap angle of 20degrees, 30degrees and 40degrees. Separation lengths, measured from Schlieren pictures, clearly show that there is 'no appreciable' effect of sweep on them. Also, using a simple local flow field calculation, the separation has been identified to be transitional in nature. These features of separation reflect in the force data. Because of the small separation length, the flaps (inspite of their small size) were very effective in generating additional C-N, C-M and C-l, which increased with increase in flap angle. In general, the C-N, C-M and X-CP were unaffected by sweep for symmetric flap deflection at positive incidences and asymmetric flap case, For symmetric flap case at negative incidences, only C-N was not influenced by the sweep but C-M decreased and X-CP moved upstream as the sweep is decreased, The wing with lower sweep produces higher CA and lower (L/D)(max) for both symmetric and asymmetric flaps. The rolling moment and adverse yaw increased with decrease in sweep for asymmetric flap deflection. Newtonian theory is shown to be incapable of predicting the effect of sweep on C-l, C-n and on the incremental values of C-N, C-M and C-A. In conclusion, it can be said that a small flap is generally adequate for hypersonic aeroplanes provided they operate at altitudes where transitional and turbulent separation can be expected to occur. This would make the flaps effective and thus enable ample control authority.
Resumo:
The objective of this study is to determine an optimal trailing edge flap configuration and flap location to achieve minimum hub vibration levels and flap actuation power simultaneously. An aeroelastic analysis of a soft in-plane four-bladed rotor is performed in conjunction with optimal control. A second-order polynomial response surface based on an orthogonal array (OA) with 3-level design describes both the objectives adequately. Two new orthogonal arrays called MGB2P-OA and MGB4P-OA are proposed to generate nonlinear response surfaces with all interaction terms for two and four parameters, respectively. A multi-objective bat algorithm (MOBA) approach is used to obtain the optimal design point for the mutually conflicting objectives. MOBA is a recently developed nature-inspired metaheuristic optimization algorithm that is based on the echolocation behaviour of bats. It is found that MOBA inspired Pareto optimal trailing edge flap design reduces vibration levels by 73% and flap actuation power by 27% in comparison with the baseline design.