393 resultados para 99mTc-DTPA
Resumo:
The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99mTc-DTPA is increased in SLE patients with active disease.
Resumo:
Two radioaerosol preparations, TechneScan®-DTPA (99mTc-DTPA, 40 mCi/3 ml; IPEN-CNEN, São Paulo, SP, Brazil) and TechneScan®-DTPA/AEROSOL (99mTc-DTPA/A, 15 mCi/1.5 ml with 0.5 ml ethanol; Mallinckrodt Medical, St. Louis, MO, USA), were compared in pulmonary ventilation studies in terms of total radiocounts and clearance after inhalation. An aerosol with ethanol is supposed to better distribute the radioparticles in the lungs. Twenty normal nonsmoking volunteers (10 men and 10 women), mean age of 23.2 years (range: 20 to 35 years), were studied. Images were obtained immediately and 30, 60 and 90 min after inhalation. Total and regional counts were obtained and the clearance half-lives of both lungs were determined. There was no difference in total counts between the two types of radioaerosol at any time (mean of ~188,000 cpm for male and female subjects at time zero in both aerosols). The highest count was obtained in the middle region of both lungs (P<0.001) with both preparations. The clearance half-life did not differ between aerosols (mean of ~80-88 min for male and female subjects for both aerosols). Small nonsignificant regional differences were observed. No differences between genders or between right and left lung were observed. 99mTc-DTPA/A generated the highest output of radioaerosol. 99mTc-DTPA with alcohol costs approximately five times more than the aerosol without alcohol. The present results show that either kind of aerosol may be adopted routinely for use in pulmonary examinations without affecting diagnosis. We suggest that the amount of 740 mBq (20 mCi) of 99mTc-DTPA in 1.5 ml saline can be used for routine examinations resulting in reduction of costs in pulmonary ventilation studies without diagnostic impairment.
Resumo:
Com o objetivo de se avaliar a importância do \"clearance\" do dietilenotriamino-pentacetato marcado com Tecnécio 99m (DTPA-Tecnécio-99m) em portadores de pneumopatia por amiodarona foram estudados 40 indivíduos, em quatro grupos. Grupo I: 10 voluntários normais, assintomáticos e não fumantes (8 homens e 2 mulheres), com média de idade de 56,80 anos. Grupo II: 10 voluntários normais, assintomáticos e fumantes (6 homens e 4 mulheres ), com média de idade de 27,50 anos. Grupo III: 10 pacientes não fumantes ( 4 homens e 5 mulheres ), com média de idade de 52,90 anos. Todos faziam uso crônico de amiodarona por via oral. Grupo IV: 10 pacientes portadores de pneumopatia por amiodarona, quatro ex-fumantes, dois fumantes e quatro não fumantes ( 8 homens e 2 mulheres) com média de idade de 52,90 anos. Todos faziam uso de amiodarona por via oral e nenhum fumou nas 4 semanas que precederam o estudo. Após espirometria que constou do registro da curva volume-tempo, todos inalaram 4 ml de solução salina contendo 740 MBq de DTPA Tecnécio-99m, durante cinco minutos. Através de uma c~mara de cintilação computadorizada foram obtidas imagens pulmonares, definindo-se 9 áreas de interesse. Para cada região escolhida foi determinada uma curva de \"clearance\" extraindo-se o valor de meia-vida biológica em minu- tos ( T 1/2 ) e a taxa percentual de \" clearance\" alvéolo capilar do radioaerossol por minuto (K%/min). Observamos que, das variáveis espirométricas consideradas, a capacidade vital forçada (CVF) e o volume expiratório forçado no 1 segundo (VEF1) mostraram diferenças significantes entre os grupos I e IV. A contagem total de radioatividade de ambos os pulmões não mostrou relação com a CVF e o VEF1. O \" clearance \" pulmonar do DTPA Tecnécio-99m foi maior nos grupos 11 e IV, porém não permitindo sua diferenciação. Estes resultados permitem concluir: Os pacientes portadores de pneumonite por amiodaro- na apresentam\" clearance \" alvéolo-capilar de DTPA Tecnécio-99m significativamente maior que os indivíduos do grupo de normais não fumantes. Este fato também se verificou em relação aos pacientes em uso crônico de amiodarona mas sem evidências de pneumopatia. Não é possível diferenciar os fumantes dos portadores de pneumonite por amiodarona através da análise da integridade da barreira alvéolo-epitelial com DTPA Tecnécio-99m. Comparativamente, o estudo da integridade alvéolo-epitelial pelo \"clearance\" pulmonar de DTPA Tecnécio-99m é mais sensível que a espirometria na avaliação da pneumonite por amiodarona, permitindo diferenciar estes pacientes dos que fazem uso crônico da droga
Resumo:
A cintilografia renal dinâmica possibilita o diagnóstico de complicações observadas nos tecidos transplantados, como desordens na perfusão do órgão, necrose tubular aguda e quadros de rejeição. Empregamos o 99mTc-DTPA neste estudo e correlacionamos os achados cintilográficos e clínicos visando ao diagnóstico de rejeição ou outra forma de complicação no órgão transplantado. Tanto as rejeições quanto as complicações foram avaliadas em relação ao tipo de imunossupressão utilizada. Foram analisados 55 pacientes submetidos a transplante renal entre 1989 e 1999. Todos os pacientes com nefrotoxicidade faziam uso do esquema tríplice de imunossupressão. Neste estudo houve predominância de rejeição aguda, em 40,4% dos casos. Treze dos quinze pacientes cujos doadores eram cadáveres tiveram necrose tubular aguda. Foi observado apenas um caso falso-positivo, em que o exame cintilográfico foi incompatível com a clínica. Sugerimos o uso da cintilografia renal no acompanhamento pós-operatório dos pacientes transplantados.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
Synthetic somatostatin (SST) analogues have been used in the preparation of receptor-specific radiopharmaceuticals for diagnostic and therapy of neuroendocrine tumors. This work studied the labeling conditions with (99m)Tc and biological distribution in Swiss mice of two SST analogs (HYNIC-Tyr(3)-Octreotide and HYNIC-Tyr(3)-Octreotate) and compared the biodistribution pattern with (111)In-DTPA-Octreotide. Biological distribution studies were performed after injection of radiopharmaceuticals on Swiss mice. Labeling procedures resulted on high radiochemical yield for all three preparations and the labeled products presented high in vitro stability. Biological distribution studies evidenced similar general biodistribution of (99m)Tc-labeled peptides when compared with indium-labeled peptide with fast blood clearance and elimination by urinary tract. Kidneys uptake of (99m)Tc-HYNIC-TATE are similar to (111)In-DTPA-Octreotide, and both are significantly higher than (99m)Tc-HYNIC-OCT. All labeled peptides presented similar uptake on liver, but the retention in time at intestines, particularly at large intestine, was more expressive for (111)In-labeled peptide. The %ID of (99m)Tc-HYNIC-OCT and (99m)Tc-HYNIC-TATE in organs with high density of SST receptors like pancreas and adrenals were significant and similar to obtained for (111)In-DTPA-Octreotide, confirming the affinity of these radiopharmaceuticals for the receptors.
Resumo:
Mestrado em Medicina Nuclear. Área de especialização: Radiofarmácia.
Resumo:
Introduction: The quantification of th e differential renal function in adults can be difficult due to many factors - on e of the se is the variances in kidney depth and the attenuation related with all the tissue s between the kidney and the camera. Some authors refer that t he lower attenuation i n p ediatric patients makes unnecessary the use of attenuation correction algorithms. This study will com pare the values of differential renal function obtained with and with out attenuation correction techniques . Material and Methods: Images from a group consisting of 15 individuals (aged 3 years +/ - 2) were used and two attenuation correction method s were applied – Tonnesen correction factors and the geometric mean method . The mean time of acquisition (time post 99m Tc - DMSA administration) was 3.5 hours +/ - 0.8h. Results: T he absence of any method of attenuation correction apparently seems to lead to consistent values that seem to correlate well with the ones obtained with the incorporation of methods of attenuation correction . The differences found between the values obtained with and without attenuation correction were not significant. Conclusion: T he decision of not doing any kind of attenuation correction method can apparently be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for a really accurate value of the relative kidney uptake, then an attenuation correction method should be used.
Resumo:
Introduction: In the XXI Century ’s Society the scientific investigation process has been growing steadily , and the field of the pharmaceutical research is one of the most enthusiastic and relevant . Here, it is very important to correlate observed functional alterations with possibly modified drug bio distribution patterns . Cancer, inflammation and inf ection are processes that induce many molecular intermediates like cytokines, chemokines and other chemical complexes that can alter the pharmacokinetics of many drugs. One cause of such changes is thought to be the modulator action of these complexes in t he P - Glyco p rotein activity, because they can act like inducers/inhibitors of MDR - 1 expression. This protein results from the expression of MDR - 1 gene, and acts as an ATP energy - dependent efflux pump, with their substrates including many drugs , like antiretrovirals, anticancers, anti - infectives, immunosuppressants, steroids or opioids . Objectives: Because of the lack of methods to provide helpful information in the investigation of in vivo molecular changes in Pgp activity during infection/infl ammation processes, and its value in the explanation of the altered drug pharmacokinetic, this paper want to evaluate the potential utility of 99m Tc - Sestamibi scintigraphy during this kind of health sciences investigation. Although the a im is indeed to create a technique to the in vivo study of Pgp activity, this preliminary Project only reaches the in vitro study phase, assumed as the first step in a n evaluation period for a new tool development. Materials and Methods: For that reason , we are performing in vitro studies of influx and efflux of 99m Tc - Sestamibi ( that is a substrate of Pgp) in hepatocytes cell line (HepG2). We are interested in clarify the cellular behavior of this radiopharmaceutical in Lipopolysaccharide(LPS) stimulated cells ( well known in vitro model of inflammation) to possibly approve this methodology. To validate the results, the Pgp expression will be finally evaluated using Western Blot technique. Results: Up to this moment , we still don’t have the final results, but we have already enough data to let us believe that LPS stimulation induce a downregulation of MDR - 1, and consequently Pgp, which could conduce to a prolonged retention of 99m Tc - Sestamibi in the inflamed cells . Conclusions: If and when this methodology demonstrate the promising results we expect, one will be able to con clude that Nuclear Medicine is an important tool to help evidence based research also on this specific field .
Resumo:
GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.
Resumo:
Introduction: Although relative uptake values aren’t the most important objective of a 99mTc-DMSA scan, they are important quantitative information. In most of the dynamic renal scintigraphies attenuation correction is essential if one wants to obtain a reliable result of the quantification process. Although in DMSA scans the absent of significant background and the lesser attenuation in pediatric patients, makes that this attenuation correction techniques are actually not applied. The geometric mean is the most common method, but that includes the acquisition of an anterior (extra) projection, which it is not acquired by a large number of NM departments. This method and the attenuation factors proposed by Tonnesen will be correlated with the absence of attenuation correction procedures. Material and Methods: Images from 20 individuals (aged 3 years +/- 2) were used and the two attenuation correction methods applied. The mean time of acquisition (time post DMSA administration) was 3.5 hours +/- 0.8h. Results: The absence of attenuation correction showed a good correlation with both attenuation methods (r=0.73 +/- 0.11) and the mean difference verified on the uptake values between the different methods were 4 +/- 3. The correlation was higher when the age was lower. The attenuation correction methods correlation was higher between them two than with the “no attenuation correction” method (r=0.82 +/- 0.8), and the mean differences of the uptake values were 2 +/- 2. Conclusion: The decision of not doing any kind of attenuation correction method can be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for an accurate value of the relative kidney uptake, then an attenuation correction method should be used. Attenuation correction factors proposed by Tonnesen can be easily implemented and so become a practical and easy to implement alternative, namely when the anterior projection - needed for the geometric mean methodology – is not acquired.