25 resultados para 6MWD
Resumo:
Objective: To evaluate the impact that the distribution of emphysema has on clinical and functional severity in patients with COPD. Methods: The distribution of the emphysema was analyzed in COPD patients, who were classified according to a 5-point visual classification system of lung CT findings. We assessed the influence of emphysema distribution type on the clinical and functional presentation of COPD. We also evaluated hypoxemia after the six-minute walk test (6MWT) and determined the six-minute walk distance (6MWD). Results: Eighty-six patients were included. The mean age was 65.2 ± 12.2 years, 91.9% were male, and all but one were smokers (mean smoking history, 62.7 ± 38.4 pack-years). The emphysema distribution was categorized as obviously upper lung-predominant (type 1), in 36.0% of the patients; slightly upper lung-predominant (type 2), in 25.6%; homogeneous between the upper and lower lung (type 3), in 16.3%; and slightly lower lung-predominant (type 4), in 22.1%. Type 2 emphysema distribution was associated with lower FEV1 , FVC, FEV1 /FVC ratio, and DLCO. In comparison with the type 1 patients, the type 4 patients were more likely to have an FEV1 < 65% of the predicted value (OR = 6.91, 95% CI: 1.43-33.45; p = 0.016), a 6MWD < 350 m (OR = 6.36, 95% CI: 1.26-32.18; p = 0.025), and post-6MWT hypoxemia (OR = 32.66, 95% CI: 3.26-326.84; p = 0.003). The type 3 patients had a higher RV/TLC ratio, although the difference was not significant. Conclusions: The severity of COPD appears to be greater in type 4 patients, and type 3 patients tend to have greater hyperinflation. The distribution of emphysema could have a major impact on functional parameters and should be considered in the evaluation of COPD patients.
Resumo:
We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.
Resumo:
Few studies show patient outcomes over time in chronic obstructive pulmonary disease (COPD). In the present study, we monitored forced expiratory volume in the first second (FEV1) and other manifestations of the disease over 3 years in 133 COPD patients (69% males, age = 65 ± 9 years, FEV1 = 59 ± 25%) evaluated at baseline. During follow-up, 15 patients (11%) died and 23 (17%) dropped out. Measurements for 95 (72%) COPD patients alive after 3 years were analyzed. FEV1, body mass index (BMI), 6-min walking distance (6MWD), Medical Research Council scale (MRC), Saint Georges Respiratory Questionnaire (SGRQ), Charlson Comorbidity index, and BODE index were obtained at baseline and after 3 years. At baseline, 17 patients (18%) presented mild, 39% moderate, 19% severe, and 24% very severe COPD. Predicted FEV1 % and BMI did not change over the period (P > 0.05). FEV1 in liters [1.25 (0.96-1.72) vs 1.26 (0.88-1.60) L; P < 0.001], 6MWD (438 ± 86 vs 412 ± 100 m; P < 0.001), MRC [1 (1-2) vs 2 (1-3); P = 0.002], Charlson index [3 (3-4) vs4 (3-5); P = 0.009], BODE index (2.2 ± 1.8 vs 2.6 ± 2.3; P = 0.008), and total SGRQ (42 ± 19 vs 44 ± 19%; P = 0.041) worsened after 3 years compared to baseline measurements. These data show that COPD patients deteriorated during the 3-year follow-up despite the fact that they had only minor modifications in airway obstruction and body composition. They support the need for comprehensive patient assessment to better identify disease progression.
Resumo:
The 6-minute walk test (6MWT) is a simple field test that is widely used in clinical settings to assess functional exercise capacity. However, studies with healthy subjects are scarce. We hypothesized that the 6MWT might be useful to assess exercise capacity in healthy subjects. The purpose of this study was to evaluate 6MWT intensity in middle-aged and older adults, as well as to develop a simple equation to predict oxygen uptake ( V ˙ O 2 ) from the 6-min walk distance (6MWD). Eighty-six participants, 40 men and 46 women, 40-74 years of age and with a mean body mass index of 28±6 kg/m2, performed the 6MWT according to American Thoracic Society guidelines. Physiological responses were evaluated during the 6MWT using a K4b2 Cosmed telemetry gas analyzer. On a different occasion, the subjects performed ramp protocol cardiopulmonary exercise testing (CPET) on a treadmill. Peak V ˙ O 2 in the 6MWT corresponded to 78±13% of the peak V ˙ O 2 during CPET, and the maximum heart rate corresponded to 80±23% of that obtained in CPET. Peak V ˙ O 2 in CPET was adequately predicted by the 6MWD by a linear regression equation: V ˙ O 2 mL·min-1·kg-1 = -2.863 + (0.0563×6MWDm) (R2=0.76). The 6MWT represents a moderate-to-high intensity activity in middle-aged and older adults and proved to be useful for predicting cardiorespiratory fitness in the present study. Our results suggest that the 6MWT may also be useful in asymptomatic individuals, and its use in walk-based conditioning programs should be encouraged.
Resumo:
Study objectives: This study was developed to investigate the influence of thoracic and upperlimb muscle function on 6-min walk distance (6MWD) in patients with COPD.Design: A prospective, cross-sectional study.Setting: the pulmonary rehabilitation center of a university hospital.Patients: Thirty-eight patients with mild to very severe COPD were evaluated.Measurements and results: Pulmonary function and baseline dyspnea index (BDI) were assessed, handgrip strength, maximal inspiratory pressure (Pimax), and 6MWD were measured, and the one-repetition maximum (1RM) was determined for each of four exercises (bench press, lat pull down, leg extension, and leg press) performed on gymnasium equipment. Quality of life was assessed using the St. George Respiratory Questionnaire (SGRQ). We found statistically significant positive correlations between 6MWD and body weight (r = 0.32; p < 0.05), BDI (r = 0.50; p < 0.01), FEV, (r = 0.33; p < 0.05), PImax (r = 0.53; p < 0.01), and all values of 1RM. A statistically significant negative correlation was observed between 6MWD and dyspnea at the end of the 6-min walk test (r = -0.29; p < 0.05), as well as between 6MWD and the SGRQ activity domain (r = -0.45; p < 0.01) and impact domain (r = -0.34; p < 0.05) and total score (r = -0.40; p < 0.01). Multiple regression analysis selected body weight, BDI, Pimax, and lat pull down IRM as predictive factors for 6MWD (R-2 = 0.589).Conclusions: the results of this study showed the importance of the skeletal musculature of the thorax and upper limbs in submaximal exercise tolerance and could open new perspectives for training programs designed to improve functional activity in COPD patients.
Resumo:
We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Past studies have shown that mean values of Interleukin-6 (IL-6) and C-reactive protein (CRP) do not change significantly in COPD patients over a one-year period. However, longer period follow-up studies are still lacking. Thus, the aim of this study is to evaluate plasma CRP and IL-6 concentration over three years in COPD patients and to test the association between these inflammatory mediators and disease outcome markers. Methods: A cohort of 77 outpatients with stable COPD was evaluated at baseline, and 53 (mean FEV1, 56% predicted) were included in the prospective study. We evaluated Interleukin-6 (IL-6), C-reactive protein (CRP), six-minute walking distance (6MWD), and body mass index (BMI) at baseline and after three years. Plasma concentration of IL-6 was measured by high sensitivity ELISA, and CRP was obtained by high sensitivity particle-enhanced immunonephelometry. Results: IL-6 increased significantly after 3 years compared to baseline measurements [0.8 (0.5-1.3) vs 2.4 (1.3-4.4) pg/ml; p < 0.001] and was associated with worse 6MWD performance. In the Cox regression, increased IL-6 at baseline was associated with mortality [Hazard Ratio (95% CI) = 2.68 (0.13, 1.84); p = 0.02]. CRP mean values did not change [5 (1.6-7.9) vs 4.7 (1.7-10) pg/L; p = 0.84], although eleven patients (21%) presented with changes >3 mg/L in CRP after 3 years. Conclusions: The systemic inflammatory process, evaluated by IL-6, seems to be persistent, progressive and associated with mortality and worse physical performance in COPD patients. Trial registration: No.:NCT00605540. © 2013 Ferrari et al; licensee BioMed Central Ltd.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB