13 resultados para 66000
Resumo:
Gandhisagar, the second largest reservoir of India is located in Mandsaur district of Madhya Pradesh at latitude 24°44'N and longitude 75°33'E at an altitude of 403.56m MSL in orientation from NE to SE. It has an extensive water spread area of 66000 ha at full reservoir level with a maximum and mean depth of 49.52 and 11.73 m respectively. The maximum length and width of the reservoir are 112 and 16km having a total shore line of 442km. Details of catchment area, bathymetry, standard hydrological data giving water level relation of the basin to water spread area, volume and fish production and the bottom topographical details of 11 experimental fishing stations and 6 fish landing centres are discussed.
Resumo:
The morphological defects and uniformity of 4H-SiC epilayers grown by hot wall CVD at 1500 degrees C on off-oriented (0001) Si faces are characterized by atomic force microscope, Nomarski optical microscopy, and Micro-Raman spectroscopy. Typical morphological defects including triangular defects, wavy steps, round pits, and groove defects are observed in mirror-like SiC epilayers. The preparation of the substrate surface is necessary for the growth of high-quality 4H-SiC epitaxial layers with low-surface defect density under optimized growth conditions. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
El libro muestra las ventajas de los cuentos populares para estimular la enseñanza del lenguaje y proporciona ideas prácticas de su uso para generar textos interesantes y divertidos para leer y escuchar, desarrollar el pensamiento crítico, estimular la conversación y la discusión, conseguir redacciones originales, tratar la gramática en contexto, explorar valores, diferencias y similitudes culturales, satisfacer las necesidades de clases con varios niveles y desarrollar habilidades académicas. Incluye cuarenta actividades y cuentos para todas las edades y niveles que pueden adaptarse a las necesidades y el contexto de cada grupo; muestra como crear tus propios ejercicios y facilita una guía de recursos impresos y en línea para conseguir material adicional.
Resumo:
In this thesis the solar part of a large grid-connected photovoltaic system design has been done. The main purpose was to size and optimize the system and to present figures helping to evaluate the prospective project rationality, which can potentially be constructed on a contaminated area in Falun. The methodology consisted in PV market study and component selection, site analysis and defining suitable area for solar installation; and system configuration optimization based on PVsyst simulations and Levelized Cost of Energy calculations. The procedure was mainly divided on two parts, preliminary and detailed sizing. In the first part the objective was complex, which included the investigation of the most profitable component combination and system optimization due to tilt and row distance. It was done by simulating systems with different components and orientations, which were sized for the same 100kW inverter in order to make a fair comparison. For each simulated result a simplified LCOE calculation procedure was applied. The main results of this part show that with the price of 0.43 €/Wp thin-film modules were the most cost effective solution for the case with a great advantage over crystalline type in terms of financial attractiveness. From the results of the preliminary study it was possible to select the optimal system configuration, which was used in the detailed sizing as a starting point. In this part the PVsyst simulations were run, which included full scale system design considering near shadings created by factory buildings. Additionally, more complex procedure of LCOE calculation has been used here considered insurances, maintenance, time value of money and possible cost reduction due to the system size. Two system options were proposed in final results; both cover the same area of 66000 m2. The first one represents an ordinary South faced design with 1.1 MW nominal power, which was optimized for the highest performance. According to PVsyst simulations, this system should produce 1108 MWh/year with the initial investment of 835,000 € and 0.056 €/kWh LCOE. The second option has an alternative East-West orientation, which allows to cover 80% of occupied ground and consequently have 6.6 MW PV nominal power. The system produces 5388 MWh/year costs about 4500,000 € and delivers electricity with the same price of 0.056 €/kWh. Even though the EW solution has 20% lower specific energy production, it benefits mainly from lower relative costs for inverters, mounting and annual maintenance expenses. After analyzing the performance results, among the two alternatives none of the systems showed a clear superiority so there was no optimal system proposed. Both, South and East-West solutions have own advantages and disadvantages in terms of energy production profile, configuration, installation and maintenance. Furthermore, the uncertainty due to cost figures assumptions restricted the results veracity.
Resumo:
The scope of this work was to compare two systems for vegetative propagation: conventional one (from cut stems) and in vitro micropropagation from axillary buds. Nodal segments (1 cm) of Mikania glomerata were used as explants. The experiments were evaluated in relation to number of shoots; % of rooting; number of roots and total fresh weight. Multiple shoots developed in MS containing 0.5 mg/L BAP. Rooting was induced in the presence of 1.0 mg/L IBA. Stems with five buds and one pair of leaves were the most appropriate for the production of cuttings. The time necessary for developing a protocol for the production of M. glomerata micropropagated plantlets was 6 months, whereas only half time was required to produce plantlets from stem cuttings. The greatest problem met during micropropagation was the culture contamination by endophytic bacteria and fungi.
Resumo:
"SupR 66000-A."